Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
Nat Commun ; 14(1): 8380, 2023 Dec 16.
Article in English | MEDLINE | ID: mdl-38104196

ABSTRACT

How aging affects cells of the human brain active milieu remains largely unknown. Here, we analyze astrocytes and neurons in the neocortical tissue of younger (22-50 years) and older (51-72 years) adults. Aging decreases the amount of reduced mitochondrial cytochromes in astrocytes but not neurons. The protein-to-lipid ratio decreases in astrocytes and increases in neurons. Aged astrocytes show morphological atrophy quantified by the decreased length of branches, decreased volume fraction of leaflets, and shrinkage of the anatomical domain. Atrophy correlates with the loss of gap junction coupling between astrocytes and increased input resistance. Aging is accompanied by the upregulation of glial fibrillary acidic protein (GFAP) and downregulation of membrane-cytoskeleton linker ezrin associated with leaflets. No significant changes in neuronal excitability or spontaneous inhibitory postsynaptic signaling is observed. Thus, brain aging is associated with the impaired morphological presence and mitochondrial malfunction of cortical astrocytes, but not neurons.


Subject(s)
Astrocytes , Cerebral Cortex , Humans , Aged , Astrocytes/metabolism , Cerebral Cortex/metabolism , Neurons/metabolism , Aging/metabolism , Glial Fibrillary Acidic Protein/metabolism , Atrophy/metabolism
2.
J Biophotonics ; 16(12): e202100392, 2023 12.
Article in English | MEDLINE | ID: mdl-37551154

ABSTRACT

Optical coherence tomography (OCT) is a promising tool for intraoperative tissue morphology determination. Several studies suggest that attenuation coefficient derived from the OCT images, can differentiate between tissues of different morphology, such as normal and pathological structures of the brain, skin, and other tissues. In the present study, the depth-resolved method for attenuation coefficient calculation was adopted for the real-world situation of the depth-dependent OCT sensitivity and additive imaging noise with nonzero mean. It was shown that in the case of sharp focusing (~10 µm spot full width at half maximum [FWHM] or smaller at 1.3 µm central wavelength) only the proposed method for depth-dependent sensitivity compensation does not introduce misleading artifacts into the calculated attenuation coefficient distribution. At the same time, the scanning beam focus spot with FWHM greater than 10 µm at 1.3 µm central wavelength allows one to use multiple approaches to the attenuation coefficient calculation without introducing noticeable bias. This feature may hinder the need for robust corrections for the depth-resolved attenuation coefficient estimations from the community.


Subject(s)
Skin , Tomography, Optical Coherence , Tomography, Optical Coherence/methods , Brain/diagnostic imaging , Algorithms , Carmustine
3.
Pharmaceuticals (Basel) ; 16(6)2023 May 26.
Article in English | MEDLINE | ID: mdl-37375743

ABSTRACT

Personalized strategies in glioblastoma treatment are highly necessary. One of the possible approaches is drug screening using patient-derived tumor cells. However, this requires reliable methods for assessment of the response of tumor cells to treatment. Fluorescence lifetime imaging microscopy (FLIM) is a promising instrument to detect early cellular response to chemotherapy using the autofluorescence of metabolic cofactors. Here, we explored FLIM of NAD(P)H to evaluate the sensitivity of patient-derived glioma cells to temozolomide (TMZ) in vitro. Our results demonstrate that the more-responsive cell cultures displayed the longest mean fluorescence lifetime τm after TMZ treatment due to an increase in the protein-bound NAD(P)H fraction α2 associated with a shift to oxidative phosphorylation. The cell cultures that responded poorly to TMZ had generally shorter τm, i.e., were more glycolytic, and showed no or insignificant changes after treatment. The FLIM data correlate well with standard measurements of cellular drug response-cell viability and proliferation index and clinical response in patients. Therefore, FLIM of NAD(P)H provides a highly sensitive, label-free assay of treatment response directly on patient-derived glioblastoma cells and can become an innovative platform for individual drug screening for patients.

4.
Front Oncol ; 13: 1133074, 2023.
Article in English | MEDLINE | ID: mdl-36937429

ABSTRACT

Introduction: To improve the quality of brain tumor resections, it is important to differentiate zones with myelinated fibers destruction from tumor tissue and normal white matter. Optical coherence tomography (OCT) is a promising tool for brain tissue visualization and in the present study, we demonstrate the ability of cross-polarization (CP) OCT to detect damaged white matter and differentiate it from normal and tumor tissues. Materials and methods: The study was performed on 215 samples of brain tissue obtained from 57 patients with brain tumors. The analysis of the obtained OCT data included three stages: 1) visual analysis of structural OCT images; 2) quantitative assessment based on attenuation coefficients estimation in co- and cross-polarizations; 3) building of color-coded maps with subsequent visual analysis. The defining characteristics of structural CP OCT images and color-coded maps were determined for each studied tissue type, and then two classification tests were passed by 8 blinded respondents after a training. Results: Visual assessment of structural CP OCT images allows detecting white matter areas with damaged myelinated fibers and differentiate them from normal white matter and tumor tissue. Attenuation coefficients also allow distinguishing all studied brain tissue types, while it was found that damage to myelinated fibers leads to a statistically significant decrease in the values of attenuation coefficients compared to normal white matter. Nevertheless, the use of color-coded optical maps looks more promising as it combines the objectivity of optical coefficient and clarity of the visual assessment, which leads to the increase of the diagnostic accuracy of the method compared to visual analysis of structural OCT images. Conclusions: Alteration of myelinated fibers causes changes in the scattering properties of the white matter, which gets reflected in the nature of the received CP OCT signal. Visual assessment of structural CP OCT images and color-coded maps allows differentiating studied tissue types from each other, while usage of color-coded maps demonstrates higher diagnostic accuracy values in comparison with structural images (F-score = 0.85-0.86 and 0.81, respectively). Thus, the results of the study confirm the potential of using OCT as a neuronavigation tool during resections of brain tumors.

5.
Biomed Opt Express ; 13(4): 2393-2413, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35519266

ABSTRACT

A pilot post-mortem study identifies a strong correlation between the attenuation coefficient estimated from the OCT data and some morphological features of the sample, namely the number of nuclei in the field of view of the histological image and the fiber structural parameter introduced in the study to quantify the difference in the myelinated fibers arrangements. The morphological features were identified from the histopathological images of the sample taken from the same locations as the OCT images and stained with the immunohistochemical (IHC) staining specific to the myelin. It was shown that the linear regression of the IHC quantitative characteristics allows adequate prediction of the attenuation coefficient of the sample. This discovery opens the opportunity for the usage of the OCT as a neuronavigation tool.

6.
Acta Neurochir (Wien) ; 164(10): 2559-2562, 2022 10.
Article in English | MEDLINE | ID: mdl-35348898

ABSTRACT

BACKGROUND: Cerebrospinal fluid (CSF) rhinorrhea as a complication of retrosigmoid craniotomy does not occur often today. This complication is primarily associated with the petrous bone drilling during surgery. METHOD: The management of this complication is shown by the example of the patient with a trigeminal schwannoma located in posterior cranial fossa operated through resrisigmoid craniotomy. Three steps of management and surgical stages of petrous bone plasty are shown. CONCLUSION: CSF rhinorrhea after retrosigmoid craniotomy is a preventable complication: petrous bone pneumatization should be evaluated preoperatively. If the air cells are open, primary plasty of the defect should be performed.


Subject(s)
Cerebrospinal Fluid Rhinorrhea , Neuroma, Acoustic , Cerebrospinal Fluid Rhinorrhea/diagnostic imaging , Cerebrospinal Fluid Rhinorrhea/etiology , Cerebrospinal Fluid Rhinorrhea/surgery , Craniotomy/adverse effects , Humans , Neuroma, Acoustic/complications , Neuroma, Acoustic/surgery , Petrous Bone/surgery , Postoperative Complications/etiology , Postoperative Complications/surgery , Retrospective Studies
7.
Diagnostics (Basel) ; 12(2)2022 Jan 28.
Article in English | MEDLINE | ID: mdl-35204427

ABSTRACT

Optical coherence tomography (OCT) has been recently suggested as a promising method to obtain in vivo and real-time high-resolution images of tissue structure in brain tumor surgery. This review focuses on the basics of OCT imaging, types of OCT images and currently suggested OCT scanner devices and the results of their application in neurosurgery. OCT can assist in achieving intraoperative precision identification of tumor infiltration within surrounding brain parenchyma by using qualitative or quantitative OCT image analysis of scanned tissue. OCT is able to identify tumorous tissue and blood vessels detection during stereotactic biopsy procedures. The combination of OCT with traditional imaging such as MRI, ultrasound and 5-ALA fluorescence has the potential to increase the safety and accuracy of the resection. OCT can improve the extent of resection by offering the direct visualization of tumor with cellular resolution when using microscopic OCT contact probes. The theranostic implementation of OCT as a part of intelligent optical diagnosis and automated lesion localization and ablation could achieve high precision, automation and intelligence in brain tumor surgery. We present this review for the increase of knowledge and formation of critical opinion in the field of OCT implementation in brain tumor surgery.

8.
Brain Lang ; 224: 105057, 2022 01.
Article in English | MEDLINE | ID: mdl-34883333

ABSTRACT

Unlike stroke, neurosurgical removal of left-hemisphere gliomas acts upon a reorganized language network and involves brain areas rarely damaged by stroke. We addressed whether this causes the profiles of neurosurgery- and stroke-induced language impairments to be distinct. K-means clustering of language assessment data (neurosurgery cohort: N = 88, stroke cohort: N = 95) identified similar profiles in both cohorts. But critically, a cluster of individuals with specific phonological deficits was only evident in the stroke but not in the neurosurgery cohort. Thus, phonological deficits are less clearly distinguished from other language deficits after glioma surgery compared to stroke. Furthermore, the correlations between language production and comprehension scores at different linguistic levels were more extensive in the neurosurgery than in the stroke cohort. Our findings suggest that neurosurgery-induced language impairments do not correspond to those caused by stroke, but rather manifest as a 'moderate global aphasia' - a generalized decline of language processing abilities.


Subject(s)
Aphasia , Glioma , Language Disorders , Stroke , Aphasia/etiology , Comprehension , Glioma/complications , Glioma/surgery , Humans , Language , Language Disorders/complications , Language Disorders/etiology , Magnetic Resonance Imaging , Stroke/complications
10.
Front Surg ; 8: 718725, 2021.
Article in English | MEDLINE | ID: mdl-34778354

ABSTRACT

Background: Simultaneous resection of bone tumors in the fronto-naso-orbital region is a great challenge due to the need for adequate reconstruction of the facial skeleton. Pre-operative virtual planning of resection margins and the simultaneous fabrication of the cranioplasty using computer-aided design/computer-aided manufacturing (CAD/CAM) technology could allow combining the tumor resection and cosmetic restoration steps into a single procedure. Methods: We present five consecutive cases of patients with bone tumors of the fronto-naso-orbital region. The indications for surgery included: (1) the presence of a major cosmetic defect; (2) progressive tumor growth. The histological examination revealed vascular malformation, hemangioma, and fibrous dysplasia in two cases. Tumor resection was performed with the help of a drilling template in form of a tumor. The computer-designed cranioplasty formed based on the non-involved side of the skull of the patient was manufactured. In one patient, the reconstruction was performed using two separate implants. Results: The position of the implant fits in with pre-operative planning in two cases; in those cases, the additional trimming of the implant or bone defect was required. Good cosmetic outcomes were noted in all patients, and no complications occurred. No repeat surgery was necessary. The template has proved to have high application potential. Conclusion: Simultaneous resection and CAD/CAM cranioplasty in the case of bone tumors in the fronto-orbital region is a promising technique with the aim of minimizing operation time and achieving a good esthetic outcome.

11.
Front Oncol ; 11: 666059, 2021.
Article in English | MEDLINE | ID: mdl-34109119

ABSTRACT

Advanced stage glioma is the most aggressive form of malignant brain tumors with a short survival time. Real-time pathology assisted, or image guided surgical procedures that eliminate tumors promise to improve the clinical outcome and prolong the lives of patients. Our work is focused on the development of a rapid and sensitive assay for intraoperative diagnostics of glioma and identification of optical markers essential for differentiation between tumors and healthy brain tissues. We utilized fluorescence lifetime imaging (FLIM) of endogenous fluorophores related to metabolism of the glioma from freshly excised brains tissues. Macroscopic time-resolved fluorescence images of three intracranial animal glioma models and surgical samples of patients' glioblastoma together with the white matter have been collected. Several established and new algorithms were applied to identify the imaging markers of the tumors. We found that fluorescence lifetime parameters characteristic of the glioma provided background for differentiation between the tumors and intact brain tissues. All three rat tumor models demonstrated substantial differences between the malignant and normal tissue. Similarly, tumors from patients demonstrated statistically significant differences from the peritumoral white matter without infiltration. While the data and the analysis presented in this paper are preliminary and further investigation with a larger number of samples is required, the proposed approach based on the macroscopic FLIM has a high potential for diagnostics of glioma and evaluation of the surgical margins of gliomas.

12.
Diagnostics (Basel) ; 10(12)2020 Nov 24.
Article in English | MEDLINE | ID: mdl-33255263

ABSTRACT

The possibility to assess molecular-biological and morphological features of particular breast cancer types can improve the precision of resection margin detection and enable accurate determining of the tumor aggressiveness, which is important for treatment selection. To enable reliable differentiation of breast-cancer subtypes and evaluation of resection margin, without performing conventional histological procedures, here we apply cross-polarization optical coherence tomography (CP-OCT) and compare it with a novel variant of compressional optical coherence elastography (C-OCE) in terms of the diagnostic accuracy (Ac) with histological verification. The study used 70 excised breast cancer specimens with different morphological structure and molecular status (Luminal A, Luminal B, Her2/Neo+, non-luminal and triple-negative cancer). Our first aim was to formulate convenient criteria of visual assessment of CP-OCT and C-OCE images intended (i) to differentiate tumorous and non-tumorous tissues and (ii) to enable more precise differentiation among different malignant states. We identified such criteria based on the presence of heterogeneities and characteristics of signal attenuation in CP-OCT images, as well as the presence of inclusions/mosaic structures combined with visually feasible assessment of several stiffness grades in C-OCE images. Secondly, we performed a blinded reader study of the Ac of C-OCE versus CP-OCT, for delineation of tumorous versus non-tumorous tissues followed by identification of breast cancer subtypes. For tumor detection, C-OCE showed higher specificity than CP-OCT (97.5% versus 93.3%) and higher Ac (96.0 versus 92.4%). For the first time, the Ac of C-OCE and CP-OCT were evaluated for differentiation between non-invasive and invasive breast cancer (90.4% and 82.5%, respectively). Furthermore, for invasive cancers, the difference between invasive but low-aggressive and highly-aggressive subtypes can be detected. For differentiation between non-tumorous tissue and low-aggressive breast-cancer subtypes, Ac was 95.7% for C-OCE and 88.1% for CP-OCT. For differentiation between non-tumorous tissue and highly-aggressive breast cancers, Ac was found to be 98.3% for C-OCE and 97.2% for CP-OCT. In all cases C-OCE showed better diagnostic parameters independently of the tumor type. These findings confirm the high potential of OCT-based examinations for rapid and accurate diagnostics during breast conservation surgery.

13.
Brain Lang ; 208: 104836, 2020 09.
Article in English | MEDLINE | ID: mdl-32673898

ABSTRACT

The left frontal aslant tract (FAT) has been proposed to be relevant for language, and specifically for spontaneous speech fluency. However, there is missing causal evidence that stimulation of the FAT affects spontaneous speech, and not language production in general. We present a series of 12 neurosurgical cases with awake language mapping of the cortex near the left FAT. Tasks for language mapping included the commonly used action picture naming, and sentence completion, tapping more specifically into spontaneous speech. A task dissociation was found in 10 participants: while being stimulated on specific sites, they were able to name a picture but could not complete a sentence. Overlaying of these sites on preoperative white-matter tract reconstructions revealed that in each individual case they were located on cortical terminations of the FAT. This corroborates the language functional specificity of the left FAT as a tract underlying fluent spontaneous speech.


Subject(s)
Brain Mapping/methods , Frontal Lobe/physiology , Language Tests , Linguistics , Speech/physiology , Adult , Female , Frontal Lobe/diagnostic imaging , Humans , Intraoperative Period , Language , Male , Middle Aged , Neural Pathways/physiology , Wakefulness/physiology , White Matter/diagnostic imaging , White Matter/physiology
14.
Neurophotonics ; 6(3): 035003, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31312669

ABSTRACT

The methods used for digital processing of optical coherence tomography (OCT) and crosspolarization (CP) OCT images are focused on improving the contrast ratio of native structural OCT images. Such advances are particularly important for the intraoperative detection of glioma margins where the visual assessment of OCT images can be difficult and lead to errors. The aim of the study was to investigate the application of optical coefficients obtained from CP OCT data for the differentiation of glial tumorous tissue from a normal brain. Pseudocolor en-face OCT maps based on two optical coefficients (the commonly used rate of attenuation in the cochannel, and in addition, the interchannel attenuation difference) were constructed for normal rat brain coronal cross sections and for brains with a 101.8 rat glioblastoma model. It was shown that the use of optical coefficients significantly increased the available information from the OCT data in comparison with unprocessed images. As a result, this allowed contrasting of the white matter from the gray matter and tumorous tissue ex vivo, and for this purpose, the interchannel attenuation difference worked better. The interchannel attenuation difference values of white matter were at least seven and two times higher than corresponding values of the cortex and tumorous tissue, whereas the same parameter for cochannel attenuation coefficient values of white matter are about 4 and 1.4. However, quantitative analysis shows that both coefficients are suitable for the purpose of glioblastoma detection from normal brain tissue regardless of whether a necrotic component was present (in all compared groups p < 0.001 ).

15.
Front Oncol ; 9: 201, 2019.
Article in English | MEDLINE | ID: mdl-31001471

ABSTRACT

This paper considers valuable visual assessment criteria for distinguishing between tumorous and non-tumorous tissues, intraoperatively, using cross-polarization OCT (CP OCT)-OCT with a functional extension, that enables detection of the polarization properties of the tissues in addition to their conventional light scattering. Materials and Methods: The study was performed on 176 ex vivo human specimens obtained from 30 glioma patients. To measure the degree to which the typical parameters of CP OCT images can be matched to the actual histology, 100 images of tumors and white matter were selected for visual analysis to be undertaken by three "single-blinded" investigators. An evaluation of the inter-rater reliability between the investigators was performed. Application of the identified visual CP OCT criteria for intraoperative use was performed during brain tumor resection in 17 patients. Results: The CP OCT image parameters that can typically be used for visual assessment were separated: (1) signal intensity; (2) homogeneity of intensity; (3) attenuation rate; (4) uniformity of attenuation. The degree of match between the CP OCT images and the histology of the specimens was significant for the parameters "signal intensity" in both polarizations, and "homogeneity of intensity" as well as the "uniformity of attenuation" in co-polarization. A test based on the identified criteria showed a diagnostic accuracy of 87-88%. Intraoperative in vivo CP OCT images of white matter and tumors have similar signals to ex vivo ones, whereas the cortex in vivo is characterized by indicative vertical striations arising from the "shadows" of the blood vessels; these are not seen in ex vivo images or in the case of tumor invasion. Conclusion: Visual assessment of CP OCT images enables tumorous and non-tumorous tissues to be distinguished. The most powerful aspect of CP OCT images that can be used as a criterion for differentiation between tumorous tissue and white matter is the signal intensity. In distinguishing white matter from tumors the diagnostic accuracy using the identified visual CP OCT criteria was 87-88%. As the CP OCT data is easily associated with intraoperative neurophysiological and neuronavigation findings this can provide valuable complementary information for the neurosurgeon tumor resection.

16.
Sci Rep ; 9(1): 2024, 2019 02 14.
Article in English | MEDLINE | ID: mdl-30765763

ABSTRACT

Optical coherence tomography (OCT) is a promising method for detecting cancer margins during tumor resection. This study focused on differentiating tumorous from nontumorous tissues in human brain tissues using cross-polarization OCT (CP OCT). The study was performed on fresh ex vivo human brain tissues from 30 patients with high- and low-grade gliomas. Different tissue types that neurosurgeons should clearly distinguish during surgery, such as the cortex, white matter, necrosis and tumorous tissue, were separately analyzed. Based on volumetric CP OCT data, tumorous and normal brain tissue were differentiated using two optical coefficients - attenuation and forward cross-scattering. Compared with white matter, tumorous tissue without necrotic areas had significantly lower optical attenuation and forward cross-scattering values. The presence of particular morphological patterns, such as necrosis and injured myelinated fibers, can lead to dramatic changes in coefficient values and create some difficulties in differentiating between tissues. Color-coded CP OCT maps based on optical coefficients provided a visual assessment of the tissue. This study demonstrated the high translational potential of CP OCT in differentiating tumorous tissue from white matter. The clinical use of CP OCT during surgery in patients with gliomas could increase the extent of tumor resection and improve overall and progression-free survival.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/pathology , Brain/diagnostic imaging , Tomography, Optical Coherence , Brain/cytology , Brain/pathology , Female , Glioma/diagnostic imaging , Glioma/pathology , Humans , Image Processing, Computer-Assisted , Male , ROC Curve
SELECTION OF CITATIONS
SEARCH DETAIL
...