Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Cureus ; 16(5): e60014, 2024 May.
Article in English | MEDLINE | ID: mdl-38854232

ABSTRACT

Kounis syndrome is defined as the concurrence of acute coronary syndrome and a condition related to mast cell activation, including anaphylaxis and anaphylactoid. A 58-year-old male hemodialysis patient underwent enhanced computed tomography (CT) using the radiocontrast medium, iopamidol for investigation of a kidney tumor. Two minutes after the administration of iopamidol, he developed respiratory symptoms and chest pain. Five minutes after that, disturbed consciousness and low blood pressure were observed. On the other hand, he did not demonstrate urticaria and swelling of the skin. A 12-lead electrocardiogram (ECG) and echocardiogram suggested the presence of cardiac ischemia. Therefore, he was diagnosed with Kounis syndrome caused by radiocontrast media. Eighteen minutes after this, he received an intramuscular injection of adrenaline (0.3 mg), and his vital signs stabilized and his ECG, echocardiogram, and symptoms improved. Without undergoing emergency coronary angiography (CAG), he was hospitalized and closely monitored. The next day, his symptoms had not worsened, and he underwent hemodialysis at his local hospital. The allergen radiocontrast media could be injurious and not sufficiently excreted if administrated for patients on weekly hemodialysis with radiocontrast medium-induced Kounis syndrome manifesting; hence, indication for emergency CAG in radiocontrast medium-induced Kounis syndrome should be cautiously evaluated by close observation.

2.
Resuscitation ; 168: 103-109, 2021 11.
Article in English | MEDLINE | ID: mdl-34600971

ABSTRACT

INTRODUCTION: The objective of this cohort study was to investigate whether the revised post-Cardiac Arrest Syndrome for Therapeutic hypothermia score (rCAST), which we previously developed as a prognostic score for adult patients with post-cardiac arrest syndrome (PCAS), is also applicable to pediatric patients. METHODS: Pediatric PCAS patients were included from an out-of-hospital cardiac arrest (OHCA) registry of the Japanese Association for Acute Medicine (JAAM). We validated the predictive accuracy of the rCAST for the neurological outcomes at 30 and 90 days. We also evaluated the probability of a good neurological outcome in each of the three specified severity categories based on the rCAST (low severity: ≤5.5; moderate severity: 6.0-14.0; high severity: ≥14.5). RESULTS: Among the 737 pediatric patients with OHCA, the data of 179 pediatric PCAS patients in whom return of spontaneous circulation was achieved were analyzed. The areas under the curve (AUC) of the rCAST for predicting the neurological outcomes at 30 days and 90 days were 0.95 (95% CI: 0.90-0.99) and 0.96 (0.91-1.00), respectively. The proportions of patients with a good neurological outcome at 30 days were 100% (12/12) in the low severity group, 36.1% (13/36) in the moderate severity group, and 2.3% (3/131) in the high severity group. CONCLUSIONS: The AUC of the rCAST for pediatric PCAS patients was found to be greater than 0.9 in the external validation, which corresponds to excellent predictive accuracy. There was no patient with good neurological outcome among the patients with more than 17.0 points (extremely high severity group).


Subject(s)
Cardiopulmonary Resuscitation , Out-of-Hospital Cardiac Arrest , Post-Cardiac Arrest Syndrome , Adult , Child , Cohort Studies , Humans , Intensive Care Units , Out-of-Hospital Cardiac Arrest/therapy , Prognosis , Registries
3.
PLoS One ; 16(4): e0251030, 2021.
Article in English | MEDLINE | ID: mdl-33930089

ABSTRACT

A previous study has shown that late failure (> 48 hours) of high-flow nasal cannula (HFNC) was associated with intensive care unit (ICU) mortality. The aim of this study was to investigate whether failure of non-invasive respiratory support, including HFNC and non-invasive positive pressure ventilation (NPPV), was also associated with the risk of mortality even if it occurs in the earlier phase. We retrospectively analyzed 59 intubated patients for acute respiratory failure due to lung diseases between April 2014 and June 2018. We divided the patients into 2 groups according to the time from starting non-invasive ventilatory support until their intubation: ≤ 6 hours failure and > 6 hours failure group. We evaluated the differences in the ICU mortality between these two groups. The multivariate logistic regression analysis showed the highest mortality in the > 6 hours failure group as compared to the ≤ 6 hours failure group, with a statistically significant difference (p < 0.01). It was also associated with a statistically significant increased 30-day mortality and decreased ventilator weaning rate. The ICU mortality in patients with acute respiratory failure caused by lung diseases was increased if the time until failure of HFNC and NPPV was more than 6 hours.


Subject(s)
Cannula/adverse effects , Intensive Care Units/standards , Intubation/adverse effects , Noninvasive Ventilation/adverse effects , Oxygen Inhalation Therapy/adverse effects , Positive-Pressure Respiration/adverse effects , Respiratory Distress Syndrome/mortality , Aged , Female , Humans , Intensive Care Units/statistics & numerical data , Male , Middle Aged , Respiratory Distress Syndrome/pathology , Respiratory Distress Syndrome/therapy , Retrospective Studies , Time Factors , Treatment Failure
4.
J Cardiol Cases ; 23(1): 53-56, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33437343

ABSTRACT

A 37-year-old man diagnosed with diffuse large B-cell lymphoma two weeks previously, visited our emergency department with sudden dyspnea. He had a severe respiratory failure with saturated percutaneous oxygen at 80% (room air). Chest radiography showed a large amount of left pleural effusion. After 1000 mL of the effusion was urgently drained, reexpansion pulmonary edema (RPE) occurred. Despite ventilator management, oxygenation did not improve and venovenous extracorporeal membrane oxygenation (VV-ECMO) was initiated in the intensive care unit. The next day, contrast-enhanced computed tomography showed a massive thrombus in the right pulmonary artery, at this point the presence of pulmonary thromboembolism (PTE) was revealed. Fortunately, the patient's condition gradually improved with anticoagulant therapy and VV-ECMO support. VV-ECMO was successfully discontinued on day 4, and chemotherapy was initiated on day 8. We speculated the following mechanism in this case: blood flow to the right lung significantly reduced due to acute massive PTE, and blood flow to the left lung correspondingly increased, which could have caused RPE in the left lung. Therefore, our observations suggest that drainage of pleural effusion when contralateral blood flow is impaired due to acute PTE may increase the risk of RPE. .

5.
Sensors (Basel) ; 20(24)2020 Dec 10.
Article in English | MEDLINE | ID: mdl-33321816

ABSTRACT

The FBG (Fiber Bragg grating) sensor is an optical fiber type strain sensor. When a person breathes, strain occurs in the lungs and diaphragm. This was verified using an FBG sensor to which part of the living body this respiratory strain propagates. When measured in the abdomen, the signal waveforms were significantly different between breathing and apnea. The respiratory cycle measured by the temperature sensor attached to the mask and the strain cycle measured by the FBG sensor almost matched. Respiratory strain was measured in the abdomen, chest, and shoulder, and the signal amplitude decreased with distance from the abdomen. In addition, the respiratory rate could be calculated from the measured strain signal. On the other hand, respiratory strain did not propagate to the elbows and wrists, which were off the trunk, and the respiratory time, based on the signal period, could not be calculated at these parts. Therefore, it was shown that respiratory strain propagated in the trunk from the abdomen to the shoulder, but not in the peripheral parts of the elbow and wrist.


Subject(s)
Optical Fibers , Respiratory Rate , Biosensing Techniques , Humans
6.
J Cardiol Cases ; 22(6): 260-264, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32837666

ABSTRACT

We treated two patients with COVID-19 pneumonia requiring mechanical ventilation. Case 1 was a 73-year-old Japanese man. Computed tomography (CT) revealed ground-glass opacities in both lungs. He had severe respiratory failure with a partial pressure of oxygen in arterial blood/fraction of inspiratory oxygen ratio (P/F ratio) of 203. Electrocardiogram showed a heart rate (HR) of 56 beats/min, slight ST depression in leads II, III, and aVF, and mild saddle-back type ST elevation in leads V1 and V2. High-sensitivity cardiac troponin T (cTnT) level was slightly elevated. Despite a high fever and hypoxemia, his HR remained within 50-70 beats/min. Case 2 was a 52-year-old Japanese woman. CT revealed ground-glass opacities in the lower left lung. Electrocardiogram showed a HR of only 81 beats/min, despite a body temperature of 39.2 °C, slight ST depression in leads V4, V5, V6, and a prominent U wave in multiple leads. She had an elevated cTnT and a P/F ratio of 165. Despite a high fever and hypoxemia, her HR remained within 50-70 beats/min. Both patients had a poor compensatory increase in their HR, despite their critical status. Relative bradycardia could be a cardiovascular complication and is an important clinical finding in patients with COVID-19. .

7.
A A Pract ; 14(7): e01247, 2020 May.
Article in English | MEDLINE | ID: mdl-32539281

ABSTRACT

We report weaning from mechanical ventilation with no coughing in a patient with coronavirus disease 2019 (COVID-19). Substituting the endotracheal tube for a supraglottic airway (SGA), which is less stimulating to the trachea, can reduce coughing with weaning from mechanical ventilation and extubation. Personal protective equipment is in short supply worldwide. Reducing spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is beneficial in terms of occupational health of health care workers.


Subject(s)
Airway Extubation/methods , Airway Management/instrumentation , Coronavirus Infections/therapy , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Pneumonia, Viral/therapy , Ventilator Weaning/instrumentation , Aged , Airway Management/methods , Betacoronavirus , COVID-19 , Coronavirus Infections/prevention & control , Coronavirus Infections/transmission , Cough , Humans , Intubation, Intratracheal , Male , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Pneumonia, Viral/transmission , Respiration, Artificial , SARS-CoV-2 , Ventilator Weaning/methods
8.
Crit Care Explor ; 2(2): e0082, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32211614

ABSTRACT

Abnormal secretion of catecholamines is well known to cause delirium. In particular, disturbances of catecholamine balance can cause ICU-acquired delirium. The aim of this study was to evaluate the association between the serum levels of catecholamines and the risk of occurrence of ICU-acquired delirium separately in patients who had/had not received exogenous catecholamines before ICU admission. DESIGN: A secondary analysis of the data of 81 patients enrolled in our previous randomized clinical trial. SETTING: ICU of an academic hospital. PATIENTS: ICU patients in whom the serum levels of catecholamines were measured at ICU admission. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We evaluated the association between the serum levels of catecholamines measured at ICU admission and the risk of ICU-acquired delirium separately in patients who had received exogenous catecholamines at ICU admission (Ex[+] group) and those who had not received exogenous catecholamines (Ex[-] group). The serum levels of norepinephrine measured at ICU admission were significantly associated with the risk of ICU-acquired delirium in the Ex(-) group (odds ratio, 2.58; 95% CI, 1.02-6.52; p = 0.046), but not in the Ex(+) group (odds ratio, 1.02; 95% CI, 0.88-1.18; p = 0.823). Furthermore, there was a statistically significant interaction effect between the serum levels of norepinephrine and the use/nonuse of exogenous catecholamines at ICU admission in relation to the risk of occurrence of ICU-acquired delirium (p interaction = 0.017). CONCLUSIONS: The serum levels of norepinephrine measured at admission were associated with the risk of occurrence of ICU-acquired delirium in patients who had not received exogenous catecholamines at ICU admission, whereas no such association was observed in those who had received exogenous catecholamines previously. Thus, the association between the serum levels of catecholamines measured at admission and the risk of ICU-acquired delirium differed between patients who had/had not received exogenous catecholamines at ICU admission.

9.
Indian J Urol ; 34(2): 152-154, 2018.
Article in English | MEDLINE | ID: mdl-29692511

ABSTRACT

Plasmablastic lymphoma (PBL) is a rare and aggressive subtype of B-cell lymphoma, which occurs typically in the oral cavity of human immunodeficiency virus (HIV)-positive patients. We report a case of a 44-year-old HIV-positive patient with a solitary polypoid mass of the left ureteropelvic junction, causing unilateral hydronephrosis and clinically mimicking urothelial carcinoma. A laparoscopic nephroureterectomy was performed, and pathological examinations revealed the mass as PBL. PBL can present in various forms, even as a polypoid mass of the upper urinary tract, and it should be considered in the differential diagnosis of any mass detected in the HIV-positive patients.

SELECTION OF CITATIONS
SEARCH DETAIL