1.
Radiology ; 303(3): 613-619, 2022 06.
Article in English | MEDLINE | ID: mdl-35315719

ABSTRACT

Background US-based diagnosis of thyroid nodules is subjective and influenced by radiologists' experience levels. Purpose To develop an artificial intelligence model based on American College of Radiology Thyroid Imaging Reporting and Data System characteristics for diagnosing thyroid nodules and identifying nodule characteristics (hereafter, MTI-RADS) and to compare the performance of MTI-RADS, radiologists, and a model trained on benign and malignant status based on surgical histopathologic analysis (hereafter, MDiag). Materials and Methods In this retrospective study, 1588 surgically proven nodules from 636 consecutive patients (mean age, 49 years ± 14 [SD]; 485 women) were included. MTI-RADS and MDiag were trained on US images of 1345 nodules (January 2018 to December 2019). The performance of MTI-RADS was compared with that of MDiag and radiologists with different experience levels on the test data set (243 nodules, January 2019 to December 2019) with the DeLong method and McNemar test. Results The area under the receiver operating characteristic curve (AUC) and sensitivity of MTI-RADS were 0.91 and 83% (55 of 66 nodules), respectively, which were not significantly different from those of experienced radiologists (0.93 [P = .45] and 92% [61 of 66 nodules; P = .07]) and exceeded those of junior radiologists (0.78 [P < .001] and 70% [46 of 66 nodules; P = .04]). The specificity of MTI-RADS (87% [154 of 177 nodules]) was higher than that of both experienced and junior radiologists (80% [141 of 177 nodules; P = .02] and 75% [133 of 177 nodules; P = .001], respectively). The AUC of MTI-RADS was higher than that of MDiag (0.91 vs 0.84, respectively; P = .001). In the test set of 243 nodules, the consistency rates between MTI-RADS and the experienced group were higher than those between MTI-RADS and the junior group for composition (79% [n = 193] vs 73% [n = 178], respectively; P = .02), echogenicity (75% [n = 183] vs 68% [n = 166]; P = .04), shape (93% [n = 227] vs 88% [n = 215]; P = .04), and smooth or ill-defined margin (72% [n = 174] vs 63% [n = 152]; P = .002). Conclusion The area under the receiver operating characteristic curve (AUC) of an artificial intelligence model based on the American College of Radiology Thyroid Imaging Reporting and Data System (TI-RADS) was higher than that of a model trained on benign and malignant status based on surgical histopathologic analysis. The AUC and sensitivity of the model based on TI-RADS exceeded those of junior radiologists; the specificity of the model was higher than that of both experienced and junior radiologists. © RSNA, 2022.


Subject(s)
Thyroid Nodule , Artificial Intelligence , Female , Humans , Middle Aged , Retrospective Studies , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Ultrasonography/methods
2.
Eur Radiol ; 31(10): 7936-7944, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33856523

ABSTRACT

OBJECTIVES: To evaluate the value of Demetics and to explore whether Demetics can help radiologists with varying years of experience in the differential diagnosis of benign from malignant thyroid nodules. METHODS: The clinical application value of Demetics was assessed by comparing the diagnostic accuracy of radiologists before and after applying Demetics. This retrospective analysis included 284 thyroid nodules that underwent pathological examinations. Two different combined methods were applied. Using method 1: the original TI-RADS classification was forcibly upgraded or downgraded by one level when Demetics classified the thyroid nodules as malignant or benign. Using method 2: the TI-RADS and benign or malignant classification of the thyroid nodules were flexibly adjusted after the physician learned the Demetics' results. RESULTS: Demetics exhibited a higher sensitivity than did junior radiologist 1 (pD1 = 0.029) and was similar in sensitivity to the two senior radiologists. Demetics had a higher AUC than both junior radiologists (pD1 = 0.042, pD2 = 0.038) and an AUC similar to that of the senior radiologists. The sensitivity (p = 0.035) and AUC (p = 0.031) of junior radiologist 1 and the specificity (p < 0.001) and AUC (p = 0.026) of junior radiologist 2 improved with combined method 1. The AUC of junior radiologist 2 improved with combined method 2 (p = 0.045). The factors influencing the diagnostic results of Demetics include sonographic signs (echogenicity and echogenic foci), contrast of the image, and nodule size. CONCLUSION: Demetics exhibited high sensitivity and accuracy in the differential diagnosis of benign from malignant thyroid nodules. Demetics could improve the diagnostic accuracy of junior radiologists. KEY POINTS: • Demetics exhibited a high sensitivity and accuracy in the differential diagnosis of benign from malignant thyroid nodules. • Demetics could improve the diagnostic accuracy of junior radiologists in the differential diagnosis of benign from malignant thyroid nodules. • Factors influencing the diagnostic results of Demetics include the sonographic signs (echogenicity and echogenic foci), contrast of the image, and nodule size.


Subject(s)
Thyroid Nodule , Diagnosis, Differential , Humans , Retrospective Studies , Sensitivity and Specificity , Thyroid Nodule/diagnostic imaging , Ultrasonography
3.
Ultrasound Med Biol ; 45(9): 2273-2280, 2019 09.
Article in English | MEDLINE | ID: mdl-31201020

ABSTRACT

Transvaginal 4-D hysterosalpingo-contrast sonography with SonoVue (TV 4-D HyCoSy) is the preferred imaging method for evaluating tubal patency. However, venous intravasation in 4-D HyCoSy may affect the diagnosis of tubal patency. The objective of this study was to analyze influencing factors of venous intravasation during TV 4-D HyCoSy. This study included 643 infertile patients who underwent TV 4-D HyCoSy. We analyzed the relationship between the incidence of venous intravasation and patients' basic clinical data, endometrial thickness, inspection timing (clean day of menstruation) and tubal patency. A total of 169 (26.28%) patients exhibited intravasation during TV 4-D HyCoSy. The following are risk factors for venous intravation: secondary infertility, type C + C, type B + C and type B + B in bilateral fallopian tubal patency grouping; endometrial thickness ≤5.45 mm; and taking TV 4-D HyCoSy after menstruation ≤6 d. Infertility duration, intrauterine lesions, a history of pelvic inflammatory disease and a history of pelvic surgery were uncorrelated with venous intravasation. To reduce the incidence of venous intravasation, TV 4-D HyCoSy should be performed 7-10 d after menstruation or when endometrial thickness is thicker than 5.45 mm.


Subject(s)
Contrast Media/pharmacokinetics , Fallopian Tube Patency Tests , Infertility, Female/diagnostic imaging , Phospholipids/pharmacokinetics , Sulfur Hexafluoride/pharmacokinetics , Ultrasonography/methods , Adult , Female , Humans , Imaging, Three-Dimensional , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity , Vagina
4.
Ultrasound Med Biol ; 45(3): 660-671, 2019 03.
Article in English | MEDLINE | ID: mdl-30578038

ABSTRACT

Imaging tests perform relatively well in the detection of rotator cuff tears (RCTs), exhibiting high sensitivity and specificity, mainly among larger full-thickness tears (tear width >1 cm). However, these tests are relatively less accurate in the detection of small full-thickness tears and partial-thickness tears. The purpose of this study was to determine the feasibility of percutaneous ultrasound-guided tendon lesionography (PUTL) using the SonoVue and the value of percutaneous shoulder puncture via contrast-enhanced ultrasound (CEUS)-a combination of percutaneous ultrasound-guided subacromial bursography (PUSB) and PUTL-in the detection of RCT subtypes. Conventional ultrasound (US), CEUS and magnetic resonance imaging (MRI) were performed and prospectively evaluated in 97 patients who had undergone arthroscopy because of suspected RCTs. The rates of detection of the various subtypes of RCTs using CEUS, PUSB, PUTL, US and MRI were evaluated. The RCT subtype detection rate via CEUS was significantly higher than the rates via US and MRI (96.9%, 74.2% and 76.3%, respectively), as were the detection rates for small full-thickness tears combined with partial-thickness tears (98.2%, 60.0% and 61.8%, respectively). The detection rate with PUSB was significantly higher than those with US and MRI in assessing full-thickness tears combined with bursal-side partial-thickness tears (93.9%, 65.3% and 65.3%, respectively). The detection rate with PUTL was significantly higher than those with US and MRI in assessing the corresponding subtypes (100.0%, 69.2% and 76.9%, respectively). On the basis of our findings, we consider PUTL a tolerable and feasible procedure. Percutaneous shoulder puncture using CEUS can be an effective alternative method with better diagnostic performance than US and MRI for the detection of RCT subtypes.


Subject(s)
Contrast Media , Image Enhancement/methods , Phospholipids , Rotator Cuff Injuries/diagnostic imaging , Sulfur Hexafluoride , Ultrasonography, Interventional/methods , Diagnosis, Differential , Feasibility Studies , Female , Humans , Male , Middle Aged , Prospective Studies , Punctures , Reproducibility of Results , Rotator Cuff/diagnostic imaging , Sensitivity and Specificity