Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Stud Health Technol Inform ; 245: 1291, 2017.
Article in English | MEDLINE | ID: mdl-29295376

ABSTRACT

We constructed a novel prognostic model using an innovative method of Bayesian Network (BN) to predict Non-Small Cell Lung Cancer survival status within 5 years after operation in the Asian population. The proposed BN model could present the relationship between prognostic factors and showed the highest performance among other machine learning (ML) algorithms.


Subject(s)
Bayes Theorem , Carcinoma, Non-Small-Cell Lung/mortality , Lung Neoplasms/mortality , Algorithms , Asian People , Carcinoma, Non-Small-Cell Lung/ethnology , Humans , Lung Neoplasms/ethnology , Prognosis
2.
J Pharm Biomed Anal ; 117: 413-8, 2016 Jan 05.
Article in English | MEDLINE | ID: mdl-26448609

ABSTRACT

A highly rapid, selective and sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to simultaneously determine trantinterol, its major phase-I metabolites and their primary conjugated metabolites in human plasma. Waters Oasis HLB C18 solid phase extraction cartridges were used in the sample preparation. The separation was carried out on an ACQUITY UPLC™ BEH C18 column with methanol/0.2% formic acid (30:70, v/v) as the mobile phase at a flow rate of 0.25 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in selective reaction monitoring (SRM) mode with the use of an electrospray ionization (ESI) source. The linear calibration curves for trantinterol, tert-butyl hydroxylated trantinterol (tert-OH-trantinterol) and 1-carbonyl trantinterol (trantinterol-COOH) were obtained in the concentration ranges of 0.200-250, 0.108-4.00 and 0.0840-5.02 ng/mL, respectively (r(2)≥0.99). The intra- and inter-day precision (relative standard deviation, RSD) values were less than 13%, and the accuracy (relative error, RE) was within ±9.9%, as determined from quality control (QC) samples for the analytes. The concentrations of conjugated forms of trantinterol and tert-OH- trantinterol in plasma were determined using selective enzyme hydrolysis. The method described herein was fully validated and successfully applied for the pharmacokinetic study of trantinterol in healthy volunteers after oral administration.


Subject(s)
Clenbuterol/analogs & derivatives , Tandem Mass Spectrometry/methods , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid/methods , Clenbuterol/blood , Clenbuterol/metabolism , Clenbuterol/pharmacokinetics , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...