Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Int J Mol Sci ; 23(21)2022 Nov 03.
Article in English | MEDLINE | ID: mdl-36362268

ABSTRACT

Diterpene alkaloids (DAs) are characteristic compounds in Aconitum, which are classified into four skeletal types: C18, C19, C20, and bisditerpenoid alkaloids. C20-DAs are thought to be the precursor of the other types. Their biosynthetic pathway, however, is largely unclear. Herein, we combine metabolomics and transcriptomics to unveil the methyl jasmonate (MJ) inducible biosynthesis of DAs in the sterile seedling of A. gymnandrum, the only species in the Subgenus Gymnaconitum (Stapf) Rapaics. Target metabolomics based on root and aerial portions identified 51 C19-DAs and 15 C20-DAs, with 40 inducible compounds. The highest content of C20-DA atisine was selected for further network analysis. PacBio Isoform sequencing integrated with RNA sequencing not only provided the full-length transcriptome but also their response to induction, revealing 1994 genes that exhibited up-regulated expression. Further, 38 genes involved in terpenoid biosynthesis were identified, including 7 diterpene synthases. In addition to the expected function of the four diterpene synthases, AgCPS5 was identified to be a new ent-8,13-CPP synthase in Aconitum and could also combine with AgKSL1 to form the C20-DAs precursor ent-atiserene. Combined with multiple network analyses, six CYP450 and seven 2-ODD genes predicted to be involved in the biosynthesis of atisine were also identified. This study not only sheds light on diterpene synthase evolution in Aconitum but also provides a rich dataset of full-length transcriptomes, systemic metabolomes, and gene expression profiles, setting the groundwork for further investigation of the C20-DAs biosynthesis pathway.


Subject(s)
Aconitum , Alkaloids , Diterpenes , Aconitum/genetics , Aconitum/metabolism , Transcriptome , Alkaloids/metabolism , Diterpenes/metabolism , Biosynthetic Pathways/genetics
2.
Acta Pharm Sin B ; 11(10): 3310-3321, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34729318

ABSTRACT

Aconitum carmichaelii is a high-value medicinal herb widely used across China, Japan, and other Asian countries. Aconitine-type diterpene alkaloids (DAs) are the characteristic compounds in Aconitum. Although six transcriptomes, based on short-read next generation sequencing technology, have been reported from the Aconitum species, the terpene synthase (TPS) corresponding to DAs biosynthesis remains unidentified. We apply a combination of Pacbio isoform sequencing and RNA sequencing to provide a comprehensive view of the A. carmichaelii transcriptome. Nineteen TPSs and five alternative splicing isoforms belonging to TPS-b, TPS-c, and TPS-e/f subfamilies were identified. In vitro enzyme reaction analysis functional identified two sesqui-TPSs and twelve diTPSs. Seven of the TPS-c subfamily genes reacted with GGPP to produce the intermediate ent-copalyl diphosphate. Five AcKSLs separately reacted with ent-CPP to produce ent-kaurene, ent-atiserene, and ent-13-epi-sandaracopimaradie: a new diterpene found in Aconitum. AcTPSs gene expression in conjunction DAs content analysis in different tissues validated that ent-CPP is the sole precursor to all DAs biosynthesis, with AcKSL1, AcKSL2s and AcKSL3-1 responsible for C20 atisine and napelline type DAs biosynthesis, respectively. These data clarified the molecular basis for the C20-DAs biosynthetic pathway in A. carmichaelii and pave the way for further exploration of C19-DAs biosynthesis in the Aconitum species.

3.
Sci Rep ; 11(1): 17932, 2021 09 09.
Article in English | MEDLINE | ID: mdl-34504113

ABSTRACT

Sensorineural hearing loss (SNHL) is one of the most profound public health concerns of the modern era, affecting 466 million people today, and projected to affect 900 million by the year 2050. Advances in both diagnostics and therapeutics for SNHL have been impeded by the human cochlea's inaccessibility for in vivo imaging, resulting from its extremely small size, convoluted coiled configuration, fragility, and deep encasement in dense bone. Here, we develop and demonstrate the ability of a sub-millimeter-diameter, flexible endoscopic probe interfaced with a micro-optical coherence tomography (µOCT) imaging system to enable micron-scale imaging of the inner ear's sensory epithelium in cadaveric human inner ears.


Subject(s)
Catheters , Cochlea/diagnostic imaging , Hearing Loss, Sensorineural/diagnostic imaging , Tomography, Optical Coherence/instrumentation , Tomography, Optical Coherence/methods , Animals , Cadaver , Disease Models, Animal , Hearing Loss, Sensorineural/etiology , Humans , Mice , Mice, Inbred CBA , Noise/adverse effects
4.
J Pharm Biomed Anal ; 193: 113713, 2021 Jan 30.
Article in English | MEDLINE | ID: mdl-33160222

ABSTRACT

Aconitum L., the main source of Aconitum medicinal materials, is rich in diterpenoid alkaloids. Several drugs derived from diterpenoid alkaloids are widely used to the current clinical treatment of pain, inflammation, and other symptoms. This paper aims to clarify the main metabolites and distribution of diterpenoid alkaloids in different parts of Aconitum plants. To that end, 7 species of Aconitum from three subgenera were analyzed by UHPLC-Q-TOF-MS under identical conditions. The fragmentation regularity of various types of diterpene alkaloids were determined and a total of 126 metabolites were identified by comparing the reference material and secondary mass spectrometry, with the literature. 67, 49, 17, 41, 14, 17 and 21 metabolites were identified from Aconitum carmichaeli, Aconitum stylosum, Aconitum sinomontanum, Aconitum vilmorinianum, Aconitum pendulum, Aconitum tanguticum and Aconitum gymnandrum, respectively. Meanwhile, the structure type of A. carmichaeli, A. stylosum, A. vilmorinianum, A. pendulum, A. gymnandrum were identified as C19 type, A. sinomontanum was C18 type, while A. tanguticum was C20 type. A high similarity of metabolites was found between A. stylosum and A. vilmorinianum. The quantitative analysis of 19 compounds and the relative peak area of all metabolites which obtained through internal standard berberine, highlighted compounds like karakoline, talatisamine and atisine as references for future study of metabolic pathways. Furthermore, results from metabolites distribution and relative peak area analysis suggest that the leaf of A. carmichaeli, the leaf and stem of A. stylosum and A. vilmorinianum, and the flower of A. pendulum have potential as medicinal resources and are worth further development. These results establish a foundation for the comprehensive utilization of Aconitum resources.


Subject(s)
Aconitum , Alkaloids , Diterpenes , Chromatography, High Pressure Liquid , Diterpenes/analysis , Plant Roots/chemistry
5.
Transl Vis Sci Technol ; 9(5): 6, 2020 04.
Article in English | MEDLINE | ID: mdl-32821478

ABSTRACT

Purpose: To image, track and map the nerve fiber distribution in excised rabbit corneas over the entire stromal thickness using micro-optical coherence tomography (µOCT) to develop a screening tool for early peripheral neuropathy. Methods: Excised rabbit corneas were consecutively imaged by a custom-designed µOCT prototype and a commercial laser scanning fluorescence confocal microscope. The µOCT images with a field of view of approximately 1 × 1 mm were recorded with axial and transverse resolutions of approximately 1 µm and approximately 4 µm, respectively. In the volumetric µOCT image data, network maps of hyper-reflective, branched structures traversing different stromal compartments were segmented using semiautomatic image processing algorithms. Furthermore, the same corneas received ßIII-tubulin antibody immunostaining before digital confocal microscopy, and a comparison between µOCT image data and immunohistochemistry analysis was performed to validate the nerval origin of the tracked network structures. Results: Semiautomatic tracing of the nerves with a high range of different thicknesses was possible through the whole corneal volumes, creating a skeleton of the traced nerves. There was a good conformity between the hyper-reflective structures in the µOCT data and the stained nerval structures in the immunohistochemistry data. Conclusions: This article demonstrates nerval imaging and tracking as well as a spatial correlation between µOCT and a fluorescence corneal nerve standard for larger nerves throughout the full thickness of the cornea ex vivo. Translational Relevance: Owing to its advantageous properties, µOCT may become useful as a noncontact method for assessing nerval structures in humans to screen for early peripheral neuropathy.


Subject(s)
Cornea , Tomography, Optical Coherence , Animals , Microscopy, Confocal , Nerve Fibers , Rabbits
6.
Zhongguo Zhong Yao Za Zhi ; 45(23): 5645-5649, 2020 Dec.
Article in Chinese | MEDLINE | ID: mdl-33496102

ABSTRACT

Aconitum is a kind of important medicinal plant, which has been used in China for more than 2 000 years, with both a good medicinal and ornamental value. However, due to the lack of effective breeding methods and low seed and root propagation coefficients, the comprehensive development and utilization of Aconitum were greatly restricted. Tissue culture is an important basis for seed selection, germplasm conservation and genetic engineering. Therefore, this paper summarized the research on tissue culture of Aconitum, put forward the main problems and corresponding countermeasures, and provided important references for accelerating the seedling breeding of Aconitum and conducting the basic research of molecular biology.


Subject(s)
Aconitum , Plants, Medicinal , China , Plant Breeding , Seedlings
7.
Light Sci Appl ; 8: 104, 2019.
Article in English | MEDLINE | ID: mdl-31798843

ABSTRACT

Cross-sectional visualisation of the cellular and subcellular structures of human atherosclerosis in vivo is significant, as this disease is fundamentally caused by abnormal processes that occur at this scale in a depth-dependent manner. However, due to the inherent resolution-depth of focus tradeoff of conventional focusing optics, today's highest-resolution intravascular imaging technique, namely, optical coherence tomography (OCT), is unable to provide cross-sectional images at this resolution through a coronary catheter. Here, we introduce an intravascular imaging system and catheter based on few-mode interferometry, which overcomes the depth of focus limitation of conventional high-numerical-aperture objectives and enables three-dimensional cellular-resolution intravascular imaging in vivo by a submillimetre diameter, flexible catheter. Images of diseased cadaver human coronary arteries and living rabbit arteries were acquired with this device, showing clearly resolved cellular and subcellular structures within the artery wall, such as individual crystals, smooth muscle cells, and inflammatory cells. The capability of this technology to enable cellular-resolution, cross-sectional intravascular imaging will make it possible to study and diagnose human coronary disease with much greater precision in the future.

9.
Opt Lett ; 42(4): 867-870, 2017 Feb 15.
Article in English | MEDLINE | ID: mdl-28198885

ABSTRACT

We report the design and fabrication of a flexible, longitudinally scanning high-resolution micro-optical coherence tomography (µOCT) endobronchial probe, optimized for micro-anatomical imaging in airways. The 2.4 mm diameter and flexibility of the probe allows it to be inserted into the instrument channel of a standard bronchoscope, enabling real-time video guidance of probe placement. To generate a depth-of-focus enhancing annular beam, we utilized a new fabrication method, whereby a hollow glass ferrule was angle-polished and gold-coated to produce an elongated annular reflector. We present validation data that verifies the preservation of linear scanning, despite the use of flexible materials. When utilized on excised, cultured mouse trachea, the probe acquired images of comparable quality to those obtained by a benchtop µOCT system.


Subject(s)
Bronchi/cytology , Bronchi/diagnostic imaging , Mechanical Phenomena , Signal-To-Noise Ratio , Tomography, Optical Coherence/instrumentation , Animals , Cilia/metabolism , Equipment Design , Mice , Trachea/cytology , Trachea/diagnostic imaging
10.
Optica ; 4(8): 959-965, 2017 Aug.
Article in English | MEDLINE | ID: mdl-29675447

ABSTRACT

Improving lateral resolution for cross-sectional optical coherence tomography (OCT) imaging is difficult due to the rapid divergence of light once it is focused to a small spot. To overcome this obstacle, we introduce a fiber optics system that generates a coaxially focused multimode (CAFM) beam for depth of focus (DOF) extension. We fabricated a CAFM beam OCT probe and show that the DOF is more than fivefold that of a conventional Gaussian beam, enabling cross-sectional imaging of biological tissues with clearly resolved cellular and subcellular structures over more than a 400 µm depth range. The compact and straightforward design and high-resolution extended DOF imaging capabilities of this technique suggests that it will be very useful for endoscopic cross-sectional imaging of human internal organs in vivo.

11.
Opt Express ; 24(5): 5555-5564, 2016 Mar 07.
Article in English | MEDLINE | ID: mdl-29092377

ABSTRACT

Optical coherence tomography (OCT) is an attractive medical modality due to its ability to acquire high-resolution, cross-sectional images inside the body using flexible, small-diameter, scanning fiber optic probes. Conventional, cross-sectional OCT imaging technologies have approximately 10-µm axial resolution and 30-µm lateral resolution, specifications that enable the visualization of microscopic architectural morphology. While this resolution is useful for many clinical applications, it is insufficient for resolving individual cells that characterize many diseases. To address this gap, a supercontinuum-laser-based, µm-resolution OCT (µOCT) system and a 500 µm-diameter, extended depth of focus single fiber optic probe for endoscopic and intravascular imaging were designed and fabricated. At the distal tip of the fiber optic probe, a cylindrical waveguide was used to divide the wavefront to provide multiple circular propagation modes. Once transmitted through a relatively high NA lens (NA >0.1), these modes were projected as multiple coaxial foci (~3 µm full width at half maximum (FWHM)) over a greatly extended focal depth range. The distal tip of the probe also contained a common-path reference reflectance to minimize polarization and dispersion imbalances between sample and reference arm light. Measurements showed that the probe provides a 20-fold depth of focus extension, maintaining a 3-5 µm lateral resolution (FWHM of PSF) and a 2 µm axial resolution over a depth range of approximately 1 mm. These results suggest that this new optical configuration will be useful for achieving high-resolution, cross-sectional OCT imaging in catheter/endoscope-based medical imaging devices.

12.
J Opt Soc Am A Opt Image Sci Vis ; 32(11): 2169-77, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26560931

ABSTRACT

Optical coherence tomography (OCT) is an imaging technique that constructs a depth-resolved image by measuring the optical path-length difference between broadband light backscattered from a sample and a reference surface. For many OCT sample arm optical configurations, sample illumination and backscattered light detection share a common path. When a phase mask is placed in the sample path, features in the detected signal are observed, which suggests that an analysis of a generic common path OCT imaging system is warranted. In this study, we present a Fourier optics analysis using a Fresnel diffraction approximation of an OCT system with a path-length-multiplexing element (PME) inserted in the sample arm optics. The analysis may be generalized for most phase-mask-based OCT systems. A radial-angle-diverse PME is analyzed in detail, and the point spread function, coherent transfer function, sensitivity of backscattering angular diversity detection, and signal formation in terms of sample spatial frequency are simulated and discussed. The analysis reveals important imaging features and application limitations of OCT imaging systems with a phase mask in the sample path optics.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Models, Theoretical , Tomography, Optical Coherence/instrumentation , Tomography, Optical Coherence/methods , Computer Simulation , Equipment Design , Equipment Failure Analysis , Fourier Analysis , Light , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity
13.
Biomed Opt Express ; 6(5): 1665-78, 2015 May 01.
Article in English | MEDLINE | ID: mdl-26137371

ABSTRACT

New optical imaging techniques that provide contrast to study both the anatomy and composition of atherosclerotic plaques can be utilized to better understand the formation, progression and clinical complications of human coronary artery disease. We present a dual-modality fiber-based optical imaging system for simultaneous microstructural and molecular analysis of atherosclerotic plaques that combines optical coherence tomography (OCT) and two-photon luminescence (TPL) imaging. Experimental results from ex vivo human coronary arteries show that OCT and TPL optical contrast in recorded OCT-TPL images is complimentary and in agreement with histological analysis. Molecular composition (e.g., lipid and oxidized-LDL) detected by TPL imaging can be overlaid onto plaque microstructure depicted by OCT, providing new opportunities for atherosclerotic plaque identification and characterization.

14.
Lasers Surg Med ; 47(6): 485-94, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26018531

ABSTRACT

BACKGROUND AND OBJECTIVES: Atherosclerosis and plaque rupture leads to myocardial infarction and stroke. A novel hybrid optical coherence tomography (OCT) and two-photon luminescence (TPL) fiber-based imaging system was developed to characterize tissue constituents in the context of plaque morphology. STUDY DESIGN/MATERIALS AND METHODS: Ex vivo coronary arteries (34 regions of interest) from three human hearts with atherosclerotic plaques were examined by OCT-TPL imaging. Histological sections (4 µm in thickness) were stained with Oil Red O for lipid, Von Kossa for calcium, and Verhoeff-Masson Tri-Elastic for collagen/elastin fibers and compared with imaging results. RESULTS: Biochemical components in plaques including lipid, oxidized-LDL, and calcium, as well as a non-tissue component (metal) are distinguished by multi-channel TPL images with statistical significance (P < 0.001). TPL imaging provides complementary optical contrast to OCT (two-photon absorption/emission vs scattering). Merged OCT-TPL images demonstrate the distribution of lipid deposits in registration with detailed plaque surface profile. CONCLUSIONS: Results suggest that multi-channel TPL imaging can effectively identify lipid sub-types and different plaque components. Furthermore, fiber-based hybrid OCT-TPL imaging simultaneously detects plaque structure and composition, improving the efficacy of vulnerable plaque detection and characterization.


Subject(s)
Coronary Vessels/pathology , Luminescent Measurements/methods , Multimodal Imaging/methods , Plaque, Atherosclerotic/pathology , Tomography, Optical Coherence/methods , Aged , Humans , In Vitro Techniques , Male , Middle Aged
15.
J Biomed Opt ; 19(1): 16001, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24390374

ABSTRACT

Using a fiber-based swept-source (SS) polarization-sensitive optical coherence tomography (PS-OCT) system, we investigate the degree of polarization (DOP) of light backscattered from the retinal nerve fiber layer (RNFL) in normal human subjects. Algorithms for processing data were developed to analyze the deviation in phase retardation and intensity of backscattered light in directions parallel and perpendicular to the nerve fiber axis (fast and slow axes of RNFL). Considering superior, inferior, and nasal quadrants, we observe the strongest degradation in the DOP with increasing RNFL depth in the temporal quadrant. Retinal ganglion cell axons in normal human subjects are known to have the smallest diameter in the temporal quadrant, and the greater degradation observed in the DOP suggests that higher polarimetric noise may be associated with neural structure in the temporal RNFL. The association between depth degradation in the DOP and RNFL structural properties may broaden the utility of PS-OCT as a functional imaging technique.


Subject(s)
Retinal Neurons/pathology , Tomography, Optical Coherence/methods , Adult , Aged , Algorithms , Axons/pathology , Female , Humans , Image Processing, Computer-Assisted , Light , Middle Aged , Nerve Fibers/pathology , Normal Distribution , Optic Nerve/pathology , Retinal Ganglion Cells/pathology , Scattering, Radiation , Young Adult
16.
J Glaucoma ; 23(1): e45-52, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23835671

ABSTRACT

PURPOSE: Compare performance of normalized reflectance index (NRI) and retinal nerve fiber layer thickness (RNFLT) parameters determined from optical coherence tomography (OCT) images for glaucoma and glaucoma suspect diagnosis. METHODS: Seventy-five eyes from 71 human subjects were studied: 33 controls, 24 glaucomatous, and 18 glaucoma-suspects. RNFLT and NRI maps were measured using 2 custom-built OCT systems and the commercial instrument RTVue. Using area under the receiver operating characteristic curve, RNFLT and NRI measured in 7 RNFL locations were analyzed to distinguish between control, glaucomatous, and glaucoma-suspect eyes. RESULTS: The mean NRI of the control group was significantly larger than the means of glaucomatous and glaucoma-suspect groups in most RNFL locations for all 3 OCT systems (P<0.05 for all comparisons). NRI performs significantly better than RNFLT at distinguishing between glaucoma-suspect and control eyes using RTVue OCT (P=0.008). The performances of NRI and RNFLT for classifying glaucoma-suspect versus control eyes were statistically indistinguishable for PS-OCT-EIA (P=0.101) and PS-OCT-DEC (P=0.227). The performances of NRI and RNFLT for classifying glaucomatous versus control eyes were statistically indistinguishable (PS-OCT-EIA: P=0.379; PS-OCT-DEC: P=0.338; RTVue OCT: P=0.877). CONCLUSIONS: NRI is a promising measure for distinguishing between glaucoma-suspect and control eyes and may indicate disease in the preperimetric stage. Results of this pilot clinical study warrant a larger study to confirm the diagnostic power of NRI for diagnosing preperimetric glaucoma.


Subject(s)
Glaucoma/diagnosis , Nerve Fibers/pathology , Optic Disk/pathology , Optic Nerve Diseases/diagnosis , Retinal Ganglion Cells/pathology , Adult , Aged , Aged, 80 and over , Area Under Curve , Cross-Sectional Studies , Early Diagnosis , Female , Humans , Intraocular Pressure , Male , Middle Aged , Ocular Hypertension/diagnosis , Pilot Projects , Tomography, Optical Coherence
17.
Opt Lett ; 38(21): 4374-7, 2013 Nov 01.
Article in English | MEDLINE | ID: mdl-24177097

ABSTRACT

A low-resolution path-length-multiplexed scattering angle diverse optical coherence tomography (PM-SAD-OCT) is constructed to investigate the scattering properties of the retinal nerve fiber layer (RNFL). Low-resolution PM-SAD-OCT retinal images acquired from a healthy human subject show the variation of RNFL scattering properties at retinal locations around the optic nerve head. The results are consistent with known retinal ganglion cell neural anatomy and principles of light scattering. Application of PM-SAD-OCT may provide potentially valuable diagnostic information for clinical retinal imaging.


Subject(s)
Retina/cytology , Scattering, Radiation , Tomography, Optical Coherence/methods , Animals , Humans , Phantoms, Imaging
18.
J Biomed Opt ; 18(5): 56005, 2013 May.
Article in English | MEDLINE | ID: mdl-23640076

ABSTRACT

A swept-source dual-wavelength photothermal (DWP) optical coherence tomography (OCT) system is demonstrated for quantitative imaging of microvasculature oxygen saturation. DWP-OCT is capable of recording three-dimensional images of tissue and depth-resolved phase variation in response to photothermal excitation. A 1,064-nm OCT probe and 770-nm and 800-nm photothermal excitation beams are combined in a single-mode optical fiber to measure microvasculature hemoglobin oxygen saturation (SO(2)) levels in phantom blood vessels with a range of blood flow speeds (0 to 17 mm/s). A 50-µm-diameter blood vessel phantom is imaged, and SO(2) levels are measured using DWP-OCT and compared with values provided by a commercial oximeter at various blood oxygen concentrations. The influences of blood flow speed and mechanisms of SNR phase degradation on the accuracy of SO(2) measurement are identified and investigated.


Subject(s)
Microvessels/physiology , Oximetry/methods , Oxygen/blood , Signal Processing, Computer-Assisted , Tomography, Optical Coherence/methods , Models, Cardiovascular , Oxyhemoglobins/chemistry , Phantoms, Imaging , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...