1.
Cell Rep Methods ; 2(11): 100336, 2022 11 21.
Article in English | MEDLINE | ID: mdl-36452866

ABSTRACT

We recently determined that the excitatory manipulation of Qrfp-expressing neurons in the preoptic area of the hypothalamus (quiescence-inducing neurons [Q neurons]) induced a hibernation-like hypothermic/hypometabolic state (QIH) in mice. To control the QIH with a higher time resolution, we develop an optogenetic method using modified human opsin4 (OPN4; also known as melanopsin), a G protein-coupled-receptor-type blue-light photoreceptor. C-terminally truncated OPN4 (OPN4dC) stably and reproducibly induces QIH for at least 24 h by illumination with low-power light (3 µW, 473 nm laser) with high temporal resolution. The high sensitivity of OPN4dC allows us to transcranially stimulate Q neurons with blue-light-emitting diodes and non-invasively induce the QIH. OPN4dC-mediated QIH recapitulates the kinetics of the physiological changes observed in natural hibernation, revealing that Q neurons concurrently contribute to thermoregulation and cardiovascular function. This optogenetic method may facilitate identification of the neural mechanisms underlying long-term dormancy states such as sleep, daily torpor, and hibernation.


Subject(s)
Hibernation , Opsins , Torpor , Animals , Humans , Mice , Hibernation/physiology , Hypothalamus/physiology , Optogenetics , Sleep/physiology , Torpor/physiology , Opsins/genetics
2.
Sensors (Basel) ; 19(24)2019 Dec 10.
Article in English | MEDLINE | ID: mdl-31835545

ABSTRACT

This paper reports on-line mixture quantification with FAIMS. Ternary gas mixtures composed of acetone, ethanol, and diethyl ether were used for quantification. We succeeded in an on-line quantification of ppm-level concentration and even sub-ppm-level gases using the gradient descent method. It took 10 minutes to quantify the ternary mixture. However, it was too long, because we aim to track the temporal change of each component concentration in the mixture. Then, an algorithm based on feedback control was introduced to reduce the quantification time. The feedback method successfully tracked concentrations in three cases. The simulation result shows that the proposed method can reduce the quantification time.

3.
Sensors (Basel) ; 19(13)2019 Jul 08.
Article in English | MEDLINE | ID: mdl-31288429

ABSTRACT

Gas mixture quantification is essential for the recording and reproducing odors, because an odor consists of multiple chemical compounds. Gas mixture quantification using field asymmetric ion mobility spectrometry (FAIMS) was studied. Acetone, ethanol, and diethyl ether were selected as components of a ternary gas mixture sample as representatives of the ketone, alcohol, and ether chemical classes, respectively. One hundred and twenty-five points with different concentrations were measured. The results were evaluated by error hypersurface, variance, and the coefficient of variation. The error hypersurface showed that it is possible to reach the target composition by following the error-hypersurface gradient. Successful convergence was achieved with the gradient descent method in a simulation based on the measurement data. This result verified the feasibility of the quantification of a gas mixture using FAIMS.