Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Oral Health ; 23(1): 866, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37964229

ABSTRACT

BACKGROUND: The purpose of this study was to compare the segmentation performances of the 2D, 2.5D, and 3D networks for maxillary sinuses (MSs) and lesions inside the maxillary sinus (MSL) with variations in sizes, shapes, and locations in cone beam CT (CBCT) images under the same constraint of memory capacity. METHODS: The 2D, 2.5D, and 3D networks were compared comprehensively for the segmentation of the MS and MSL in CBCT images under the same constraint of memory capacity. MSLs were obtained by subtracting the prediction of the air region of the maxillary sinus (MSA) from that of the MS. RESULTS: The 2.5D network showed the highest segmentation performances for the MS and MSA compared to the 2D and 3D networks. The performances of the Jaccard coefficient, Dice similarity coefficient, precision, and recall by the 2.5D network of U-net + + reached 0.947, 0.973, 0.974, and 0.971 for the MS, respectively, and 0.787, 0.875, 0.897, and 0.858 for the MSL, respectively. CONCLUSIONS: The 2.5D segmentation network demonstrated superior segmentation performance for various MSLs with an ensemble learning approach of combining the predictions from three orthogonal planes.


Subject(s)
Maxillary Sinus , Spiral Cone-Beam Computed Tomography , Humans , Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Maxillary Sinus/diagnostic imaging , Deep Learning , Sinus Floor Augmentation
2.
Environ Technol ; 36(5-8): 983-91, 2015.
Article in English | MEDLINE | ID: mdl-25267420

ABSTRACT

Methane in a simulated biogas converting to methanol under aerobic condition was comparatively assessed by inhibiting the activity of methanol dehydrogenase (MDH) of Methylosinus sporium using phosphate, NaCl, NH4Cl or EDTA in their varying concentrations. The highest amount of methane was indistinguishably diverted at the typical conditions regardless of the types of inhibitors: 35°C and pH 7 under a 0.4% (v/v) of biogas, specifically for <40 mM phosphate, 50 mM NaCl, 40 mM NH4Cl or 150 µM EDTA. The highest level of methanol was obtained for the addition of 40 mM phosphate, 100 mM NaCl, 40 mM NH4Cl or 50 µM EDTA. In other words, 0.71, 0.60, 0.66 and 0.66 mmol methanol was correspondingly generated by the oxidation of 1.3, 0.67, 0.74 and 1.3 mmol methane. It gave a methanol conversion rate of 54.7%, 89.9%, 89.6% and 47.8%, respectively. Among them, the maximum rate of methanol production was observed at 6.25 µmol/mg h for 100 mM NaCl. Regardless of types or concentrations of inhibitors differently used, methanol production could be nonetheless identically maximized when the MDH activity was limitedly hampered by up to 35%.


Subject(s)
Alcohol Oxidoreductases/antagonists & inhibitors , Methanol/metabolism , Methylosinus/enzymology , Ammonium Chloride/chemistry , Biofuels , Edetic Acid/chemistry , Hydrogen-Ion Concentration , Oxidation-Reduction , Sodium Chloride/chemistry , Temperature
3.
Article in English | MEDLINE | ID: mdl-22217090

ABSTRACT

1,4-Dioxane is one of the by-products from the polyester manufacturing process, which has been carelessly discharged into water bodies and is a weak human carcinogen. In this study, a laboratory-scale, up-flow biological aerated filter (UBAF), packed with tire chips, was investigated for the treatment of 1,4-dioxane. The UBAF was fed with effluent, containing an average of 31 mg/L of 1,4-dioxane, discharged from an anaerobic treatment unit at H Co. in the Gumi Industrial Complex, South Korea. In the batch, a maximum of 99.5 % 1,4-dioxane was removed from an influent containing 25.6 mg/L. In the continuous mode, the optimal empty bed contact time (EBCT) and air to liquid flow rate (A:L) were 8.5 hours and 30:1, respectively. It was also found that the removal efficiency of 1,4-dioxane increased with increasing loading rate within the range 0.04 to 0.31 kg 1,4-dioxane/m(3)·day. However, as the COD:1,4-dioxane ratio was increased within the range 3 to 46 (mg/L COD)/(mg/L 1,4-dioxane), the removal efficiency unexpectedly decreased.


Subject(s)
Bacteria, Aerobic/metabolism , Bioreactors , Dioxanes/metabolism , Waste Disposal, Fluid/methods , Water Pollutants, Chemical/metabolism , Aerobiosis , Bacteria, Aerobic/classification , Bacteria, Aerobic/genetics , Biofilms/classification , Biological Oxygen Demand Analysis , Bioreactors/microbiology , DNA, Bacterial/genetics , DNA, Ribosomal/genetics , Filtration , Industrial Waste , Microscopy, Electron, Scanning , Oxygen/analysis , Polyesters , Sewage/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...