Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Nat Commun ; 15(1): 4160, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755128

ABSTRACT

The regeneration of critical-size bone defects, especially those with irregular shapes, remains a clinical challenge. Various biomaterials have been developed to enhance bone regeneration, but the limitations on the shape-adaptive capacity, the complexity of clinical operation, and the unsatisfied osteogenic bioactivity have greatly restricted their clinical application. In this work, we construct a mechanically robust, tailorable and water-responsive shape-memory silk fibroin/magnesium (SF/MgO) composite scaffold, which is able to quickly match irregular defects by simple trimming, thus leading to good interface integration. We demonstrate that the SF/MgO scaffold exhibits excellent mechanical stability and structure retention during the degradative process with the potential for supporting ability in defective areas. This scaffold further promotes the proliferation, adhesion and migration of osteoblasts and the osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs) in vitro. With suitable MgO content, the scaffold exhibits good histocompatibility, low foreign-body reactions (FBRs), significant ectopic mineralisation and angiogenesis. Skull defect experiments on male rats demonstrate that the cell-free SF/MgO scaffold markedly enhances bone regeneration of cranial defects. Taken together, the mechanically robust, personalised and bioactive scaffold with water-responsive shape-memory may be a promising biomaterial for clinical-size and irregular bone defect regeneration.


Subject(s)
Biocompatible Materials , Bone Regeneration , Fibroins , Magnesium , Mesenchymal Stem Cells , Osteogenesis , Tissue Scaffolds , Fibroins/chemistry , Fibroins/pharmacology , Bone Regeneration/drug effects , Animals , Tissue Scaffolds/chemistry , Male , Osteogenesis/drug effects , Mesenchymal Stem Cells/drug effects , Mesenchymal Stem Cells/cytology , Rats , Magnesium/chemistry , Magnesium/pharmacology , Biocompatible Materials/chemistry , Osteoblasts/drug effects , Cell Differentiation/drug effects , Rats, Sprague-Dawley , Water/chemistry , Cell Proliferation/drug effects , Tissue Engineering/methods , Skull/drug effects , Cell Adhesion/drug effects , Bombyx
2.
Bioengineering (Basel) ; 10(7)2023 Jun 25.
Article in English | MEDLINE | ID: mdl-37508783

ABSTRACT

This study compares the accuracy and safety of pedicle screw placement using a 3D navigation template with the free-hand fluoroscopy technique in scoliotic patients. Fifteen scoliotic patients were recruited and divided into a template group (eight cases) and a free-hand group (seven cases). All patients received posterior corrective surgeries, and the pedicle screw was placed using a 3D navigation template or a free-hand technique. After surgery, the positions of the pedicle screws were evaluated using CT. A total of 264 pedicle screws were implanted in 15 patients. Both the two techniques were found to achieve satisfactory safety of screw insertion in scoliotic patients (89.9% vs. 90.5%). In the thoracic region, the 3D navigation template was able to achieve a much higher accuracy of screw than the free-hand technique (75.3% vs. 60.4%). In the two groups, the accuracy rates on the convex side were slightly higher than on the concave side, while no significance was seen. In terms of rotational vertebrae, no significant differences were seen in Grades I or II vertebrae between the two groups. In conclusion, the 3D navigation template technique significantly increased the accuracy of thoracic pedicle screw placement, which held great potential for extensively clinical application.

3.
Global Spine J ; 13(3): 724-729, 2023 Apr.
Article in English | MEDLINE | ID: mdl-33783245

ABSTRACT

STUDY DESIGN: A biomechanical study. OBJECTIVES: The purpose of this study was to investigate the effects of cruciform and square incisions of annulus fibrosus (AF) on the mechanical stability of bovine intervertebral disc (IVD) in multiple degrees of freedom. METHODS: Eight bovine caudal IVD motion segments (bone-disc-bone) were obtained from the local abattoir. Cruciform and square incisions were made at the right side of the specimen's annulus using a surgical scalpel. Biomechanical testing of three-dimensional 6 degrees of freedom was then performed on the bovine caudal motion segments using the mechanical testing and simulation (MTS) machine. Force, displacement, torque and angle were recorded synchronously by the MTS system. P value <.05 was considered statistically significant. RESULTS: Cruciform and square incisions of the AF reduced both axial compressive and torsional stiffness of the IVD and were significantly lower than those of the intact specimens (P < .01). Left-side axial torsional stiffness of the cruciform incision was significantly higher than a square incision (P < .01). Neither incision methods impacted flexional-extensional stiffness or lateral-bending stiffness. CONCLUSIONS: The cruciform and square incisions of the AF obviously reduced axial compression and axial rotation, but they did not change the flexion-extension and lateral-bending stiffness of the bovine caudal IVD. This mechanical study will be meaningful for the development of new approaches to AF repair and the rehabilitation of the patients after receiving discectomy.

4.
Brain Sci ; 12(11)2022 Nov 19.
Article in English | MEDLINE | ID: mdl-36421907

ABSTRACT

The Zero-P spacer was primarily developed aiming to reduce the morbidity associated with the traditional anterior cervical plate. During the past decade, many authors have reported the use of Zero-P spacers for anterior cervical discectomy and fusion (ACDF) of one or two segments. Nevertheless, there is still a paucity of knowledge on the safety and feasibility of using Zero-P spacers for 3-level fixation. The objective of this study was to investigate the clinical and radiological outcomes, with a focus on the sagittal alignment reconstruction of 3-level ACDF surgery using Zero-P spacers versus those using a traditional plate and cage system. From Sep 2013 to Aug 2016, a total of 44 patients who received 3-level ACDF surgery due to cervical spondylotic myelopathy were recruited. The Zero-P spacer was used in 23 patients (group ZP) and the traditional plate and cage system in 21 (group PC). Clinical outcomes were analyzed by Neck Disability Index (NDI) and Japanese Orthopedic Association (JOA) scores, and dysphagia was evaluated using the Bazaz score. Radiological outcomes, including fusion rate, adjacent segment degeneration (ASD), and especially changes in cervical sagittal alignment, were analyzed. The NDI and JOA scores did not differ significantly between the two groups postoperatively (p > 0.05); however, there was significantly less dysphagia in patients using Zero-P spacers at the 3- and 6-month follow-up (p < 0.05). At the 24-month follow-up, the fusion rate and ASD were similar between the two groups (p > 0.05). Interestingly, patients using Zero-P spacers had a significantly lower postoperative C2-7 Cobb angle and fused segment Cobb angle, compared to those using a traditional plate and cage system (p < 0.05); meanwhile, the fused segment disc wedge was also found to be significantly smaller in patients using Zero-P spacers after surgery (p < 0.05). Moreover, we further divided patients into subgroups according to their cervical lordosis. In patients with a preoperative C2-7 Cobb angle ≤ 10°, significantly less cervical and local lordosis, as well as disc wedge, were seen in group ZP after surgery (p < 0.05), while in others with a preoperative C2-7 Cobb angle > 10°, no significant difference in postoperative changes of the cervical sagittal alignment was seen between group ZP and group PC (p > 0.05). Zero-P spacers used in 3-level ACDF surgery could provide equivalent clinical outcomes and a lower rate of postoperative dysphagia, compared to the traditional plate and cage system. However, our results showed that it was inferior to the cervical plate in terms of sagittal alignment reconstruction for 3-level fixation. We recommend applying Zero-P spacers for 3-level ACDF in patients with good preoperative cervical lordosis (C2-7 Cobb angle > 10°), in order to restore and maintain physiological curvature of the cervical spine postoperatively.

5.
JOR Spine ; 5(3): e1218, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36203863

ABSTRACT

Backgrounds: Cartilaginous endplate (CEP) plays an essential role in intervertebral disc (IVD) health and disease. The aim was to compare the CEP structure of lumbar IVD and to reveal the detailed pattern of integration between the CEP and bony endplate (BEP) from different species. Methods: A total of 34 IVDs (5 human, 5 goat, 8 pig, 8 rabbit, and 8 rat IVDs) were collected, fixed and midsagittally cut; in each IVD, one-half was used for histological staining to observe the CEP morphology, and the other half was used for scanning electron microscopy (SEM) analysis to measure the diameters and distributions of collagen fibers in the central and peripheral CEP areas and to observe the pattern of CEP-BEP integration from different species. Results: The human, pig, goat, and rabbit IVDs had the typical BEP-CEP structure, but the rat CEP was directly connected with the growth plate. Human CEP was the thickest (896.95 ± 87.71 µm) among these species, followed by pig, goat, rat, and rabbit CEPs. Additionally, the mean cellular density of the rabbit CEP was the highest, which was 930 ± 202 per mm2, followed by the rat, goat, pig, and human CEPs. In all the species, the collagen fiber diameter in the peripheral area was much bigger than that in the central area. The collagen fiber diameters of CEP from the human, pig, goat, and rat were distributed between 35 nm and 65 nm. The BEP and CEP were connected by the collagen from the CEP, aggregating into bundles or cross links with each other to form a network, and anchored to BEP. Conclusions: Significant differences in the thickness, cellular density, and collagen characterization of CEPs from different species were demonstrated; the integration of BEP-CEP in humans, pigs, goats, and rabbits was mainly achieved by the collagen bundles anchoring system, while the typical BEP-CEP interface did not exist in rats.

6.
Front Oncol ; 12: 1047194, 2022.
Article in English | MEDLINE | ID: mdl-36776364

ABSTRACT

Background: Osteosarcoma (OS) is a malignant bone tumor mainly affecting children and young adolescents. Cisplatin is a first-line chemotherapy drug for OS, however, drug resistance severely limits the survival of OS. Nevertheless, cellular factors in cisplatin resistance for OS remain obscure. In this study, the function and potential mechanism of p53 in cisplatin absorption were explored in OS cells. Methods: The CRISPR-Cas9 gene editing technology was performed to obtain p53 gene knock-out U2OS cells. The p53 over-expression 143B cell line was established by lentivirus-mediated virus infection. Moreover, the functions of p53 and CTR1 in cisplatin absorption were assessed by inductively coupled plasma mass spectrometry (ICP-MS) through CTR1 over-expression and knock-down. Further, the DNA binding activity of SP1 on CTR1 gene promoter was determined by dual-luciferase assay and chromatin immunoprecipitation (ChIP) assay. The functional regulation of p53 on SP1 was studied by nucleocytoplasmic separation assay and electrophoretic mobility shift assay (EMSA). The interaction between p53 and SP1 was verified by Co-Immunoprecipitation assay. Results: Under cisplatin treatment, p53 knock-out promoted CTR1 expression and cisplatin uptake, while p53 overexpression inhibited CTR1 expression and cisplatin uptake. Moreover, p53 regulated CTR1 level not by binding to CTR1 promoter directly but by suppressing the nuclear translocation of transcription factor specificity protein 1 (SP1). It was verified that SP1 is directly bound with CTR1 promoter. SP1 overexpression stimulated CTR1 expression, and SP1 knock-down attenuated CTR1 expression. Conclusion: The p53 might function as a negative regulator in CTR1 mediated cisplatin absorption, and the p53-SP1-CTR1 axis is a target for cisplatin resistance.

7.
Spine J ; 21(2): 273-283, 2021 02.
Article in English | MEDLINE | ID: mdl-32966909

ABSTRACT

BACKGROUND CONTEXT: Anterior controllable antedisplacement and fusion (ACAF) is a novel surgical technique for the treatment of ossification of the posterior longitudinal ligament (OPLL). Its prognostic factors for decompression have not been well studied. Additionally, no detailed radiological standard has been set for hoisting the vertebrae-OPLL complex (VOC) in ACAF. PURPOSE: To identify the possible prognostic factors for decompression outcomes after ACAF for cervical OPLL, to determine the critical value of radiological parameters for predicting good outcomes, and to establish a radiological standard for hoisting the VOC in ACAF. STUDY DESIGN: This was a retrospective multicenter study. PATIENT SAMPLE: A total of 121 consecutive patients with OPLL who underwent ACAF at a point between January 2017 and June 2018 at any one of seven facilities and were monitored for at least 1 year afterward were enrolled in a multicenter study. OUTCOME MEASURES: Japanese Orthopedic Association (JOA) scores, recovery rate (RR) of neurologic function, and surgical complications were used to determine the effectiveness of ACAF. METHODS: Patients were divided into two groups according to their RR for neurologic function. Patients with an RR of ≥50% and an RR of <50% were designated as having good and poor decompression outcomes, respectively. The relationship between various possible prognostic factors and decompression outcomes was assessed by univariate and multivariate analysis. The receiver operating characteristic curve was used to determine the optimal cutoff value of the radiological parameters for prediction of good decompression outcomes. Next, the patients were redivided into three groups according to the cutoff value of the selected radiological parameter (postoperative anteroposterior canal diameter [APD] ratio). Patients with postoperative APD ratios of ≤80.7%, 80.7%-100%, and ≥100% were defined as members of the incomplete, optimal, and excessive antedisplacement groups, respectively. Differences in decompression outcomes among the three groups were compared to verify the reliability of the postoperative APD ratio and assess the necessity of excessive antedisplacement. RESULTS: Multivariate logistic regression analysis showed that patients' age at surgery (odds ratio [OR]=1.18; 95% confidence interval [CI]=1.08-1.29; p<.01) and postoperative APD ratio (OR=0.83; 95% CI=0.77-0.90; p<.01) were independently associated with decompression outcomes. The optimal cutoff point of the postoperative APD ratio was calculated at 80.7%, with 86.2% sensitivity and 73.5% specificity. There were no significant differences in the postoperative JOA scores and RRs between the excessive antedisplacement group and optimal antedisplacement group (p>.05). However, a lower incidence of cerebrospinal fluid leakage and screw slippage was observed in the optimal antedisplacement group (p<.05). CONCLUSIONS: Patients' age at surgery and their postoperative APD ratio are the two prognostic factors of decompression outcomes after ACAF. The postoperative APD ratio is also the most accurate radiological parameter for predicting good outcomes. Our findings suggest that it is essential for neurologic recovery to restore the spinal canal to more than 80.7% of its original size (postoperative APD ratio >80.7%), and restoration to less than its original size (postoperative APD ratio <100%) will help reduce the incidence of surgical complications. This may serve as a valuable reference for establishment of a radiological standard for hoisting the VOC in ACAF.


Subject(s)
Ossification of Posterior Longitudinal Ligament , Spinal Fusion , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Decompression, Surgical , Humans , Ossification of Posterior Longitudinal Ligament/diagnostic imaging , Ossification of Posterior Longitudinal Ligament/surgery , Reproducibility of Results , Retrospective Studies , Spinal Canal , Spinal Fusion/adverse effects , Treatment Outcome
8.
World J Orthop ; 11(11): 523-527, 2020 Nov 18.
Article in English | MEDLINE | ID: mdl-33269219

ABSTRACT

BACKGROUND: The correction surgery for severely multidimensional spinal deformity in neurofibromatosis type I is very difficult and it is still a very big challenge for spine surgeons. CASE SUMMARY: A 44-year-old woman presented with progressive kyphosis for more than 10 years and low back pain for 2 years. She had been diagnosed with neurofibromatosis at a local hospital many years ago. Conservative treatments had been applied, but the symptoms got worse rather than alleviated. Therefore, surgery was required. CONCLUSION: For this patient with severe deformity, the correction treatment of Ponte osteotomy followed by satellite rod technique in the region of the apical vertebra and the technique of pedicle screws and dual iliac screws had been applied, and successful clinical outcomes were achieved.

9.
Int J Biochem Cell Biol ; 122: 105719, 2020 05.
Article in English | MEDLINE | ID: mdl-32087327

ABSTRACT

Osteoporosis is a skeletal disorder, the pathogenic factors of which include the decreased ability of osteogenesis and enhanced osteolysis. Human-derived mesenchymal stem cells (hMSCs) possess the differential capacity to osteoblasts and chondrocytes, so the application of hMSCs in bone tissue is promising to be effective. A group of RNAs which lack of 5' and 3'ends called circular RNAs (circRNAs) were discovered. In this study, we described a previously found circular RNA, circ_0076906, to bind miR-1305 and regulate its target gene, Osteoglycin (OGN), thus regulate osteogenic differentiation of hMSCs and alleviate the progression of osteoporosis. Osteogenic differentiation induced in hMSCs; qRT-PCR and western blot to examine the expressions of mRNAs and proteins; Alkaline phosphatase activity and Alizarin red staining to examine bone formation; luciferase report experiments to detect the interaction between molecules; and the nuclear/cytoplasm separation of cells. 1. Circ_0076906 was induced in osteogenic differentiation; 2. Circ_0076906 silencing inhibited osteogenesis-related genes in hMSCs; 3. Circ_0076906 acted as a sponge for miR-1305; 4. MiR-1305 regulated OGN expression; 5. Circ_0076906 induced-osteogenic differentiation depended on miR-1305/ OGN pathway. Circ_0076906 relieved osteoporosis and promoted osteogenic differentiation through the miR-1305/ OGN pathway.


Subject(s)
Intercellular Signaling Peptides and Proteins/metabolism , MicroRNAs/metabolism , Osteoporosis/genetics , Osteoporosis/metabolism , RNA, Circular/metabolism , Binding Sites , Cell Differentiation/physiology , Cells, Cultured , Disease Progression , Female , Humans , Intercellular Signaling Peptides and Proteins/genetics , Male , MicroRNAs/genetics , Middle Aged , Osteoporosis/pathology , RNA, Circular/genetics
10.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 32(6): 764-768, 2018 06 15.
Article in Chinese | MEDLINE | ID: mdl-29905058

ABSTRACT

Objective: To summarize the current research progress of second sacral alar-iliac (S 2AI) screw technique for reconstruction of spinopelvic stability. Methods: The recent original literature concerning development, clinical applications, anatomy, imageology, and biomechanics of S 2AI screw technique in reconstruction of spinopelvic stability was reviewed and analyzed. Results: As a common clinical strategy for the reconstruction of spinopelvic stability, S 2AI screws achieve satisfactory effectiveness of lumbosacral fixation without complications which were found during the application of traditional iliac screws technique. S 2AI screw technique is more difficult to place screws by hand because of its narrow screw trajectory. Although the S 2AI screws trajectory pass through 3 layers of bone cortex, the biomechanical cadaveric study demonstrate that no statistical difference in stiffness was found between the traditional iliac and S 2AI screw in a spinopelvic fixation model. Conclusion: S 2AI screw technique should be a safe and feasible method for reconstruction of spinopelvic stability in place of the traditional iliac screw technique.


Subject(s)
Bone Screws , Joint Instability , Plastic Surgery Procedures , Spinal Fusion , Biomechanical Phenomena , Cadaver , Humans , Ilium/surgery , Joint Instability/surgery , Sacrum/surgery
13.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 30(12): 1512-1517, 2016 Dec 08.
Article in Chinese | MEDLINE | ID: mdl-29786344

ABSTRACT

OBJECTIVE: To investigate the bone regeneration potential of cell-tissue engineered bone constructed by human bone marrow mesenchymal stem cells (hBMSCs) expressing the transduced human bone morphogenetic protein 2 (hBMP-2) gene stably. METHODS: The full-length hBMP-2 gene was cloned from human muscle tissues by RT-PCR and connected into a vector to consturct a eukaryotic expression system. And then the gene expression system was transduced to hBMSCs with lipidosome. hBMSCs were transfected by hBMP-2 gene (experimental group) and by empty plasmid (negative control group), untransfected hBMP-2 served as blank control group. RT-PCR, dot-ELISA, immunohistochemical analysis and ALP activity were performed to compare and evaluate the situation of hBMP-2 expression and secretion after transfection. hBMSCs transfected by hBMP-2 gene were seeded on hydroxyapatite (HA) and incubated for 4 days to construct the hBMP-2 gene modified tissue engineered bone, and then the tissue engineered bone was observed by the inverted phase contrast microscope and scanning electron microscope. Then the hBMP-2 gene modified tissue engineered bone (group A, n=3), empty plasmid transfected hBMSCs seeded on HA (group B, n=3), hBMSCs suspension transfected by hBMP-2 gene (group C, n=3), and hBMP-2 plasmids and lipidosome (group D, n=3) were implanted into bilateral back muscles of nude mice. The osteogenic activity was detected by HE staining and alcian blue staining after 4 weeks. RESULTS: At 48 hours and 3 weeks after transfection, RT-PCR and dot-ELISA results indicated that the transfected hBMSCs could express and secrete active and exogenous hBMP-2 stably. The immunohistochemical staining was positive, and the ALP activity in the transfected hBMSCs was significantly higher than that in two control groups (P<0.05). The transfected hBMSCs had a good attaching and growing on the three-demension suface of HA under inverted phase contrast microscope and scanning electron microscope. In vivo study indicated that a lot of new bone formation was obviously found at 4 out of 6 sides of back muscles in group A. Some new bone formation at both sides of back muscles was observed in 1 of 3 mice in group B. No new bone formation was found in group C. A few new bone formation was observed at one side of back muscles in group D. CONCLUSIONS: The tissue engineered bone constructed by hBMP-2 gene modified hBMSCs and HA is able to express and secrete active hBMP2 stably and can promote new bone formation effectively in muscles of nude mice.


Subject(s)
Bone Morphogenetic Protein 2/genetics , Genetic Therapy , Mesenchymal Stem Cells , Tissue Engineering , Animals , Bone Marrow Cells , Bone Morphogenetic Protein 2/physiology , Cells, Cultured , Gene Expression , Humans , Mice , Mice, Nude , Osteogenesis , Transfection
14.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 30(9): 1160-1165, 2016 Sep 08.
Article in Chinese | MEDLINE | ID: mdl-29786375

ABSTRACT

OBJECTIVE: To summarize the current research progress of three-dimensional (3D) printing technique for spinal implants manufacture. METHODS: The recent original literature concerning technology, materials, process, clinical applications, and development direction of 3D printing technique in spinal implants was reviewed and analyzed. RESULTS: At present, 3D printing technologies used to manufacture spinal implants include selective laser sintering, selective laser melting, and electron beam melting. Titanium and its alloys are mainly used. 3D printing spinal implants manufactured by the above materials and technology have been successfully used in clinical. But the problems regarding safety, related complications, cost-benefit analysis, efficacy compared with traditional spinal implants, and the lack of relevant policies and regulations remain to be solved. CONCLUSIONS: 3D printing technique is able to provide individual and customized spinal implants for patients, which is helpful for the clinicians to perform operations much more accurately and safely. With the rapid development of 3D printing technology and new materials, more and more 3D printing spinal implants will be developed and used clinically.


Subject(s)
Printing, Three-Dimensional , Prostheses and Implants , Research/trends , Spine , Tissue Engineering/methods , Humans , Plastic Surgery Procedures/methods , Spinal Diseases/surgery , Titanium
15.
Article in Chinese | MEDLINE | ID: mdl-23879102

ABSTRACT

OBJECTIVE: To evaluate the biomechanical effect of a self-made iliac screw plate on the stability of lumbo-iliac fixation construct before and after fatigue loading. METHODS: Twelve fresh lumbo-pelvic specimens from donated adult cadavers with formalin embalm were used in the study. According to whether use the iliac screw plate or not, the specimens were randomly assigned into group A (with iliac screw plate, n=6) and group B (without iliac screw plate, n=6). The bone mineral density (BMD) of L(t-4) was measured using dual-energy radiograph absorptiometry. The pedicle screw and iliac screw fixation were given at L3-5, and bilateral facetectomy and diskectomy at L5, S1 level were performed to prepare the model of the intervertebral destabilization. The biomechanical testing was conducted on a material testing machine under 0-600 N compression and -7-7 N.m torsion loading modes for the initial compressive stiffness and torsional stiffness evaluation. And then 20 000 cyclic compressive loading of 40-400 N was given to the specimen, the stiffness evaluation was repeated. Then the maximum pull-out strength of screws at every level was measured and compared. Gross observation and radiological observation were performed during experiment. RESULTS: The BMD values of groups A and B were (1.15 +/-0.13) g/cm(2) and (1.12 +/-0.11) g/cm(2) respectively, showing no significant difference between 2 groups (t=0.428, P=0.678). All pedicle screws and iliac screws were inserted in good position; no loosening or breaking of screw was observed during loading. After fatigue loading, the incidence of halo ring around the iliac screws of groups A and B was 16.7% (1/6) and 50.0% (3/6), respectively. The compressive stiffness and torsional stiffness after fatigue loading were significantly lower than those in initial state in groups A and B (P < 0.05); there was no significant difference in compressive stiffness and torsional stiffness between groups A and B before fatigue loading (P > 0.05). However, group A had higher compressive stiffness than group B (t=2.664, P=0.024) after fatigue loading, and there was no significant difference in torsional stiffness between 2 groups (t=0.410, P=0.690). No significant difference was found in screw pull-out strength of pedicle screws at L3, L4, and L5 levels between groups A and B (P > 0.05); however, the pull-out strength of the iliac screws in group A was significantly higher than that in group B (t=3.398, P=0.007). In groups A and B, the pull-out strength of L3 screw was significantly lower than that of L4 and L5 screws (P < 0.05). In group A, pull-out strength of the iliac screws was significantly higher than that of L3, L4, and L5 screws (P < 0.05); in group B, the pull-out strength of iliac screws was significantly lower than that of L4 and L5 screws (P < 0.05). CONCLUSION: In the lumbo-iliac reconstruction, the use of iliac screw plate could resist iliac screw loosening, therefore, it has the potential to increase the stability oflumbo-iliac fixation construct.


Subject(s)
Bone Screws , Ilium/surgery , Lumbar Vertebrae/surgery , Sacrum/surgery , Aged , Biomechanical Phenomena , Bone Density , Bone Plates , Cadaver , Female , Humans , Ilium/diagnostic imaging , Internal Fixators , Intervertebral Disc/physiopathology , Intervertebral Disc/surgery , Joint Instability/surgery , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/physiopathology , Male , Middle Aged , Radiography , Range of Motion, Articular , Sacrum/diagnostic imaging , Stress, Mechanical
16.
J Spinal Disord Tech ; 24(6): E49-56, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21685804

ABSTRACT

STUDY DESIGN: An in vitro biomechanical cadaver study. OBJECTIVES: To evaluate the pull-out strength after 5000 cyclic loading among 4 revision techniques for the loosened iliac screw using corticocancellous bone, longer screw, traditional cement augmentation, and boring cement augmentation. SUMMARY OF BACKGROUND DATA: Iliac screw loosening is still a clinical problem for lumbo-iliac fusion. Although many revision techniques using corticocancellous bone, larger screw, and polymethylmethacrylate (PMMA) augmentation were applied in repairing pedicle screw loosening, their biomechanical effects on the loosened iliac screw remain undetermined. METHODS: Eight fresh human cadaver pelvises with the bone mineral density values ranging from 0.83 to 0.97 g/cm were adopted in this study. After testing the primary screw of 7.5 mm diameter and 70 mm length, 4 revision techniques were sequentially established and tested on the same pelvis as follows: corticocancellous bone, longer screw with 100 mm length, traditional PMMA augmentation, and boring PMMA augmentation. The difference of the boring technique from traditional PMMA augmentation is that PMMA was injected into the screw tract through 3 boring holes of outer cortical shell without removing the screw. On an MTS machine, after 5000 cyclic compressive loading of -200∼-500 N to the screw head, axial maximum pull-out strengths of the 5 screws were measured and analyzed. RESULTS: The pull-out strengths of the primary screw and 4 revised screws with corticocancellous bone, longer screw and traditional and boring PMMA augmentation were 1167 N, 361 N, 854 N, 1954 N, and 1820 N, respectively. Although longer screw method obtained significantly higher pull-out strength than corticocancellous bone (P<0.05), the revised screws using these 2 techniques exhibited notably lower pull-out strength than the primary screw and 2 PMMA-augmented screws (P<0.05). Either traditional or boring PMMA screw showed obviously higher pull-out strength than the primary screw (P<0.05); however, no significant difference of pull-out strength was detected between the 2 PMMA screws (P>0.05). CONCLUSIONS: Wadding corticocancellous bone and increasing screw length failed to provide sufficient anchoring strength for a loosened iliac screw; however, both traditional and boring PMMA-augmented techniques could effectively increase the fixation strength. On the basis of the viewpoint of minimal invasion, the boring PMMA augmentation may serve as a suitable salvage technique for iliac screw loosening.


Subject(s)
Bone Cements , Bone Screws , Ilium/surgery , Lumbar Vertebrae/surgery , Prosthesis Failure , Aged , Biomechanical Phenomena , Female , Humans , Internal Fixators , Male , Middle Aged , Reoperation
17.
Zhonghua Yi Xue Za Zhi ; 91(15): 1041-6, 2011 Apr 19.
Article in Chinese | MEDLINE | ID: mdl-21609639

ABSTRACT

OBJECTIVE: To investigate vertebral augmentation with a novel reticulate bone filling container system by polymethyl methacrylate (PMMA) injection in cadaveric simulated vertebral compressive fracture and explore the effect of reticulate bone filling container on cement distribution controlling within vertebral body and the restoration of biomechanical properties after augmentation. METHODS: A total of 28 freshly frozen human vertebrae specimens were randomly divided into 4 groups. After the measurements of bone mineral density (BMD) and vertebral height, each vertebra received an axle load by a MTS (material testing system) machine to test the initial strength and stiffness. Subsequently a simultaneous compressive fracture model was created to measure the stiffness and height of fractured vertebrae. Then the augmentation procedure was performed. Afterward the biomechanical properties and the vertebral height were similarly measured as pre-operatively. The expansion of bone filling container and the distribution of cement within vertebral body were morphologically observed by crossing the specimens in sagittal midline and also integrated with the radiographic results. RESULTS: Stiffness was significantly restored comparing with that of fractured level (P < 0.05). And the bipedicular groups had better restoration results than the unipedicular groups. The strength and height of specimens significantly increased after the augmentation procedure but without difference among groups. In axial radiographic view, the distribution of cement in vertebral body was oval or long oval-shaped in double-layer bone filling container groups while it was irregular in single-layer groups. After crossing, the double-layer version expanded well in vertebral body and could enwrap most of injected cement. There was only a little leakage near the vessel layer. But the single-layer version had a poor expansion and a large amount of cement leakage. CONCLUSION: This novel reticulate bone void filling container system with different layers may restore both the biomechanical properties and the height of fractured vertebrae. But, with the benefit of reducing cement leakage, a double-layer design can enwrap most of injected PMMA and has a brighter prospect of clinical application.


Subject(s)
Bone Substitutes , Stress, Mechanical , Vertebroplasty/instrumentation , Biomechanical Phenomena , Bone Density , Humans , Lumbar Vertebrae , Spinal Fractures/surgery , Thoracic Vertebrae , Vertebroplasty/methods
18.
Clin Biomech (Bristol, Avon) ; 26(6): 556-61, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21345556

ABSTRACT

BACKGROUND: Iliac screw loosening has been a clinical problem in the lumbo-pelvic reconstruction. Although iliac screws are commonly inserted into either upper or lower iliac column, the biomechanical effects of the two fixations and their revision techniques with bone cement remain undetermined. The purpose of this study was to compare the anchoring strengths of the upper and lower iliac screws with and without cement augmentation. METHODS: 5 pairs of formalin fixed cadaveric ilia with the bone mineral density values ranged from 0.82 to 0.97 g/cm(2) were adopted in this study. Using screws with 70-mm length and 7.5-mm diameter, 2 conventional iliac screw fixations and their revision techniques with cement augmentation were sequentially established and tested on the same ilium as follows: upper screw, upper cement screw, lower screw, and lower cement screw. Following 2000 cyclic compressive loading of -300 N to -100 N to the screw on a material testing machine, the maximum pull-out strengths were measured and analyzed. FINDINGS: The average pull-out strengths of upper, upper cement, lower, and lower cement screws were 964 N, 1462 N, 1537 N, and 1964 N, respectively. The lower screw showed significantly higher pull-out strength than the upper one (P=0.008). The cement augmentation notably increased the pull-out strengths of both upper and lower screws. The positive correlation between pull-out strength and bone mineral density value was obtained for the 4 fixations. INTERPRETATION: The lower iliac screw technique should be the preferred choice in lumbo-pelvic stabilization surgery; cement augmentation may serve as a useful salvage technique for iliac screw loosening; preoperative evaluation of bone quality is crucial for predicting fixation strength of iliac screw.


Subject(s)
Bone Cements/chemistry , Bone Screws , Aged , Biomechanical Phenomena , Bone Density , Female , Humans , Ilium/chemistry , Male , Middle Aged , Pelvic Bones/pathology , Pelvis/pathology , Stress, Mechanical
19.
Clin Biomech (Bristol, Avon) ; 25(9): 867-72, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20655639

ABSTRACT

BACKGROUND: Although both single and dual iliac screw techniques are used in spino-pelvic reconstruction following sacrectomy for treating sacral tumors, the basis for choosing between the two techniques for different instability types remains undetermined. The purpose of this study was to evaluate the effects of the extent of sacrectomy on the stability of the lumbo-iliac fixation construct using single and dual iliac screw techniques. METHODS: Nine human L2-pelvic specimens were tested for their intact condition simulated by L3-L5 pedicle screw fixation. Sequential partial sacrectomies and L3-iliac fixation using bilateral single and dual iliac screws were conducted on the same specimens as follows: under-S1 sacrectomy+single screw, under-½S1 sacrectomy+single screw, one-side sacroiliac joint resection+single screw, total sacrectomy+single screw, and total sacrectomy+dual screw. Biomechanical testing was performed on a material testing machine for evaluating the stiffness of the L3-iliac fixation construct in compression and torsion. FINDINGS: Single iliac screw technique was found to effectively restore the local stability in under-½S1 sacrectomy. However, it could not provide adequate stability for further resection of one-side sacroiliac joint in torsion and total sacrectomy in compression (P<0.05). On the other hand, dual iliac screw technique could restore the stability to the intact condition after total sacrectomy in both compression and torsion. INTERPRETATION: The single iliac screw technique for L3-iliac fixation could effectively restore the local stability for under-½S1 sacrectomy. However, for instabilities of the under-½S1 sacrectomy with one-side sacroiliac joint resection or total sacrectomy, the dual iliac screw technique should be considered.


Subject(s)
Bone Screws , Ilium/surgery , Internal Fixators , Adult , Aged , Biomechanical Phenomena , Female , Humans , Lumbar Vertebrae/surgery , Male , Middle Aged , Sacroiliac Joint/surgery , Sacrum/surgery , Spinal Fusion/methods , Stress, Mechanical
20.
Spine (Phila Pa 1976) ; 35(15): E714-20, 2010 Jul 01.
Article in English | MEDLINE | ID: mdl-20535041

ABSTRACT

STUDY DESIGN: A prospective clinical trial was conducted. OBJECTIVE: To compare the clinical and radiologic late results of monosegmental transpedicular fixation versus short-segment pedicle instrumentation (SSPI) in management of thoracolumbar burst fractures and evaluate the efficacy of monosegmental transpedicular fixation. SUMMARY OF BACKGROUND DATA: SSPI (1 level above and 1 below the fracture level) are accepted by many surgeons as an accepted technique for the treatment of thoracolumbar burst fractures. To preserve more motion segments, some authors have advocated monosegmental pedicle instrumentation (MSPI). The recent developments showed that MSPI yielded good clinical results; however, there were no report about comparison of clinical outcome between monosegmental and biosegmental transpedicular fixation in management of thoracolumbar burst fractures. METHODS: Eighty-five patients with thoracolumbar burst fractures fulfilling the inclusion criteria were included in the study. The patients were randomized by a simple method into 2 groups. Group 1 were treated with monosegmental transpedicular fixation (n = 47), and group 2 were treated with biosegmental transpedicular fixation (n = 38). Clinical (Low Back Outcome Score and Oswestry Disability Index) and radiologic (load-sharing classification index, sagittal index, and percentage of anterior body height compression) outcomes were analyzed. RESULTS: The 2 groups were similar in age, follow-up period, and severity of the deformity and fracture. The postoperative and follow-up sagittal index, local kyphosis, percentage of anterior body height compression, and average correction loss in local kyphosis in both groups were not significantly different. The failure rate between the 2 surgical approaches was also not significantly different (group 1 = 6.38% and group 2 = 5.26%). Oswestry Disability Index improved in both groups by >25 points in a similar amount (P = 0.23). The average follow-up Low Back Outcome Score was 74.9 and 60.2 for group 1 and group 2, respectively (P = 0.033). CONCLUSION: In conclusion, radiologic parameters demonstrated that both MSPI and SSPI are the effective and reliable operative techniques for selected thoracolumbar burst fractures. MSPI shortened the operative time and decreased the amount of blood loss significantly and, thus, offered better clinical results. Nevertheless, long-term studies are supposed to be performed to support the outcomes.


Subject(s)
Fracture Fixation, Internal/methods , Lumbar Vertebrae/surgery , Spinal Fractures/surgery , Thoracic Vertebrae/surgery , Adult , Bone Screws , Disability Evaluation , Female , Fracture Fixation, Internal/instrumentation , Humans , Low Back Pain/diagnosis , Low Back Pain/etiology , Lumbar Vertebrae/injuries , Male , Middle Aged , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Prospective Studies , Reproducibility of Results , Thoracic Vertebrae/injuries , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...