1.
Opt Express ; 29(17): 26713-26723, 2021 Aug 16.
Article in English | MEDLINE | ID: mdl-34615100

ABSTRACT

Snapshot microlens array microscopic hyperspectral imaging systems do not require a scanning process and obtain (x,y,λ) three-dimensional data cubes in one shot. Currently, the three-dimensional spectra image data are interleaved on a charge-coupled device detector, which increases subsequent data processing difficulty. The optical design software cannot simulate actual engineering installation and adjustment results accurately and the tracking results cannot guide precise rapid online calibration of the snapshot microlens array microscopic hyperspectral imaging system. To solve these problems, we propose an accurate spectral image reconstruction model based on optical tracing, derive spatial dispersion equations for the prisms and gratings, establish an algorithm model for the correspondence between the microlens array's surface dispersion spectral distribution and its imaging position, and propose a three-dimensional spectral image reconstruction algorithm. Experimental results show that this algorithm's actual spectral calibration error is better than 0.2 nm. This meets the image processing requirements of snapshot microlens array microscopic hyperspectral systems.

2.
Appl Opt ; 60(7): 1896-1902, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33690279

ABSTRACT

We propose a microlens array-type snapshot hyperspectral microscope system that can provide spatial spectrum sampling according to detector frame rates for the biomedical domain. The system uses a shared optical path design. One path is used to perform direct microscopic imaging with high spatial resolution, while the other is used to collect microscopic images through a microlens array; the images are then spatially cut and reimaged such that they are spaced simultaneously by the prism-grating type hyperspectral imager's dispersion. Rapid acquisition of a three-dimensional data cube measuring 28×14×180 (x×y×λ) can be performed at the detector's frame rate. The system has a spatial resolution of 2.5 µm and can achieve 180-channel sampling of a 100 nm spectrum in the 400-800 nm spectral range with spectral resolution of approximately 0.56 nm. Spectral imaging results from biological samples show that the microlens array-type snapshot hyperspectral microscope system may potentially be applied in real-time biological spectral imaging.


Subject(s)
Biomedical Research , Diagnostic Imaging/instrumentation , Microscopy/instrumentation , Equipment Design , Humans , Imaging, Three-Dimensional/methods , Spectrum Analysis , Stomach Neoplasms/pathology