Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Ophthalmol ; 15(10): 1691-1698, 2022.
Article in English | MEDLINE | ID: mdl-36262861

ABSTRACT

AIM: To investigate the behaviors of smartphone usage and parental knowledge of vision health among primary students in the rural areas of China. METHODS: In this school-based, cross-sectional study, a total of 52 606 parents of students from 30 primary schools in the Xingguo County were investigated through an online questionnaire from July 2020 to August 2020. The self-designed questionnaire contained three parts: the demographic factors of both children and parents, parental knowledge and attitude toward myopia, and the preventive treatment of myopia. RESULTS: A total of 52 485 appropriately answered questionnaires were received, showing an effective response rate of 95.1%. The average age of the primary students was 10.1±0.98y and the prevalence of myopia among the primary students was 40.3%. The age of myopia occurrence in elementary students was significantly correlated with the parents' educational level (95%CI: 0.82-0.98, P=0.013), children's gender (95%CI: 1.08-1.20, P<0.001), school location (county or countryside) (95%CI: 0.59-0.66, P<0.001), children's smartphone ownership (95%CI: 1.09-1.26, P<0.001), and the average time spent on smartphone per day (95%CI: 0.78-0.88, P<0.001). School location in the county town, high family income, and high parents' educational level significantly affected both parents' myopia awareness and children's vision-threatening behaviors (P<0.01). Left-behind children showed a higher incidence of vision-threatening habits than those who lived with their parents (P<0.01). CONCLUSION: The results reveal the current situation of myopia development among rural primary school students and their parents. This survey will serve as a guidance for designing myopic prevention policies in the rural areas of China.

2.
Neural Regen Res ; 16(2): 394-400, 2021 02.
Article in English | MEDLINE | ID: mdl-32859805

ABSTRACT

Glycogen synthase kinase-3ß (GSK-3ß) has been shown to attenuate DNA damage in nerve cells, thereby enhancing neuronal survival under pathological conditions; however, the underlying mechanism remains unclear. An in vitro serum-starvation retinal neuron model and in vivo ischemia/reperfusion retina injury rat model were established and treated with SB216763, a GSK-3ß inhibitor. SB21673 decreased the formation of γ-H2A histone family member X foci and enhanced the viability of ischemic retinal neurons. In addition, SB216763 upregulated expression of phosphorylated-CREB1, a ligase IV transcription factor, and significantly increased the transcriptional activity of ligase IV in ischemic retinal neurons. These results were confirmed in rat retinas following ischemia/reperfusion injury. Furthermore, we found that unlike lithium chlorine (a well-known direct inhibitor of GSK-3ß), SB216763 inhibited GSK-3ß activity by suppressing its phosphorylation. Taken together, our results suggest that GSK-3ß inhibition enhances repair of DNA double-strand breaks by upregulating ligase IV expression in ischemic retinal neurons. This study was approved by the Institutional Animal Care and Use Committee of Zhongshan Ophthalmic Center on February 18, 2018.

3.
Int J Ophthalmol ; 11(11): 1870-1874, 2018.
Article in English | MEDLINE | ID: mdl-30450321

ABSTRACT

This study aims to evaluate the clinical results of posterior chamber implantable collamer lens (ICL) implantation in adults with high myopic anisometropic amblyopia. Thirteen patients aged 27.04±7.24y (range 19.2 to 42.5) were studied. ICL implantation was performed in 13 amblyopic eyes. The mean myopic anisometropia was significantly dropped from -10.70±3.02 D preoperatively to +0.09±1.67 D at 1mo postoperatively. The logMAR CDVA at 3d, 1, 3 and mean 9mo postoperatively improved by a mean of 1.69, 2.50, 3.01 and 3.00 lines and gained more than 2 lines accounted for 23.08% (3 eyes), 41.67% (5 eyes), 63.63% (7 eyes) and 55.56% (5 eyes), respectively. The contrast sensitivity of amblyopic eyes was significantly increased after surgery. Four patients partially recovered near stereopsis (400″ to 100″). There was no severe complications were observed. ICL implantation alone can improve vision, contrast sensitivity, and partial restoration of binocular vision in adult patients with high myopic anisometropia.

4.
Int J Ophthalmol ; 10(11): 1678-1685, 2017.
Article in English | MEDLINE | ID: mdl-29181310

ABSTRACT

AIM: To evaluate the effects of femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE) to correct high myopic anisometropic amblyopia in juvenile patients. METHODS: From November 2013 to January 2015, 33 amblyopic patients with high myopic anisometropic amblyopia were studied. FS-LASIK (30 eyes) or SMILE (3 eyes) was performed in the amblyopic eyes. Visual acuity, refraction, contrast sensitivity, stereoacuity and complications were evaluated. Patients completed follow-up examinations at 3d, 1mo, 3mo and the last follow-up time (mean 8.17±3.23mo) after surgery. RESULTS: The mean age at surgery was 9.04±3.04y (range 6-16y). The mean spherical equivalent in the amblyopic eyes was significantly decreased from -10.00±2.39 D preoperatively to -0.06±1.06 D at 1mo, -0.19±1.33 D at 3mo and -0.60±1.43 D at approximately 8mo postoperatively (P<0.05 for all). The mean myopic anisometropia was significantly decreased from -9.45±2.33 D preoperatively to +0.37±1.48 D at 1mo, -0.46±1.47 D at 3mo and -0.09±1.83 D at approximately 8mo (P<0.05 for all). The logarithm of the minimum angle of resolution (logMAR) for uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) of the amblyopic eye improved from 1.74±0.35 and 0.98±0.63 preoperatively to 0.45±0.31 and 0.41±0.33 at approximately 8mo after surgery, respectively. The logMAR CDVA at 3d, 1, 3 and 8mo postoperatively improved by means of 1.42, 2.22, 2.96, and 4.39 lines, and a gain of more than two lines accounted for 45%, 50%, 74% and 86% of all patients, respectively. The contrast sensitivity of both amblyopic eyes and dominant eyes at 0.5, 2, 8 cycles per degree was significantly improved postoperatively (P<0.05 for all). Of the 33 pediatric patients, no patients had near stereopsis preoperatively and seven patients (21.2%) recovered near stereopsis (400″ to 60″) at approximately 8mo after surgery. No intraoperative or postoperative complications occurred in any patient. CONCLUSION: FS-LASIK or SMILE can be promising alternative methods to correct high myopic anisometropic amblyopia in juvenile patients who have failed with traditional approaches.

5.
Int J Ophthalmol ; 9(12): 1790-1797, 2016.
Article in English | MEDLINE | ID: mdl-28003981

ABSTRACT

AIM: To assess the outcomes of posterior chamber implantable collamer lens (ICL) implantation in Chinese pediatric patients with unilateral high myopic amblyopia. METHODS: Eleven eyes of 11 amblyopic patients aged 11.02±3.34y underwent ICL (model V4, Staar Surgical Inc.) implantation to treat unilateral anisometropia were studied. Visual acuity, cycloplegic refraction, contrast sensitivity, stereopsis, intraocular pressure (IOP), vaulting, corneal endothelial cell count and complications were evaluated. Patients completed follow-up at 3d, 1, 3mo and the last follow-up time (mean 8.18±2.82mo) after surgery. RESULTS: The mean myopic anisometropia was -13.70±3.25 D preoperatively and +0.69±2.63 D at 8mo postoperatively. The logMAR corrected distance visual acuity (CDVA) of the amblyopic eye was 1.51±0.72 preoperatively and 0.75±0.40 at 8mo postoperatively. The logMAR CDVA at 3d, 1, 3 and 8mo postoperatively improved by a mean of 0.64, 1.55, 1.82 and 2.64 lines and gained more than 2 lines accounted for 18%, 45%, 45%, 64%, respectively. The contrast sensitivity of 0.5, 1 and 2 cpd in amblyopic eyes was significantly increased after surgery. No patient had near stereopsis recovery. The vaulting at 3 and 8mo was significantly lower than that at 1mo postoperatively. No other intraoperative or postoperative complications were observed, except an acute pupillary block glaucoma happened in a patient at two weeks postoperatively. CONCLUSION: This short-term results indicate that ICL implantation can be a promising alternative therapy for high myopic anisometropic amblyopia in pediatric patients who have failed with conventional treatments and not suitable to corneal refraction surgery.

6.
Int J Ophthalmol ; 9(1): 58-62, 2016.
Article in English | MEDLINE | ID: mdl-26949611

ABSTRACT

AIM: To compare the agreement of anterior chamber depth (ACD) and central vault measurements obtained by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) of post surgical high myopic eyes with posterior chamber phakic intraocular lens (Visian ICL; STAAR Surgical) implantation. METHODS: Fifty-two phakic eyes of 28 high myopic patients who underwent implantable Collamer lens (ICL) surgery for the correction of high myopia were studied. The postoperative ACD, the distance between the corneal endothelium and the anterior surface of ICL (cornea-ICL) and the central vault were measured with the AS-OCT system and the UBM system. Intraclass correlation coefficient (ICC) and the Bland-Altman plot were used to evaluate the repeatability and agreement of two devices. RESULTS: The mean ACD, cornea-ICL and central vault in the 52 phakic eyes after ICL surgery was 3.19±0.28 mm, 2.47±0.28 mm, 0.50±0.19 mm by AS-OCT and 3.13±0.25 mm, 2.49±0.25 mm, 0.44±0.19 mm by UBM, respectively. Pairwise comparison of ACD and central vault measurements showed significant differences between AS-OCT and UBM (P<0.05). However, no statistically significant difference was found between these imaging techniques in cornea-ICL (P>0.05). The Pearson correlation coefficient (r) between AS-OCT and UBM measurements for ACD, cornea-ICL and vault was 0.88, 0.80 and 0.89, respectively (P<0.001). The ICC was 0.89-0.94 for the measurements of AS-OCT and UBM. Bland-Altman analysis showed the 95% limits of agreement of ACD, cornea-ICL, central vault measurements between these two devices were -0.20 to 0.32 mm, -0.36 to 0.32 mm and -0.12 to 0.24 mm, respectively. CONCLUSION: Central ACD and vault measurements using AS-OCT demonstrated a slight significantly higher value than using UBM in phakic eyes after ICL surgery. These two devices should not be used interchangeably for measurements of central ACD and vault in patients after phakic intraocular lens implantation.

7.
Eye Sci ; 27(4): 202-4, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23225843

ABSTRACT

PURPOSE: Corneal topograph-guided laser subepithelial keratomileusis (LASEK) can effectively correct decentered ablation occurring post laser in situ keratomileusis (LASIK) and to enhance our understanding and diagnosis of decentered ablation following LASIK. METHODS: Previous studies in the relevant literature are reviewed, and a case report is provided. RESULTS: A patient with high myopia undergoing LASIK in both eyes presented with distorted vision in the left eye, which interfered with the vision in the right eye and caused blurred vision in both eyes. The patient was unable to see objects with both eyes. After receiving corneal topography-guided LASEK, the signs of distorted vision in the left eye and bilateral blurred vision were significantly alleviated, and the patient could see objects with both eyes simultaneously. CONCLUSION: Clinical ophthalmologists should be aware of the occurrence of decentered ablation after LASIK. Corneal topography-guided LASEK is an efficacious tool for correcting decentered ablation.


Subject(s)
Corneal Topography/methods , Keratectomy, Subepithelial, Laser-Assisted/methods , Keratomileusis, Laser In Situ/adverse effects , Myopia/surgery , Postoperative Complications/therapy , Adult , Humans
8.
Int J Ophthalmol ; 5(1): 69-73, 2012.
Article in English | MEDLINE | ID: mdl-22553758

ABSTRACT

AIM: To assess and compare the flap morphology using anterior segment optical coherence tomography (AS-OCT) in laser in situ keratomileusis (LASIK) with Femto LDV femtosecond lasers versus Hansatome mechanical Microkeratome. METHODS: AS-OCT (Visante) was used to compare 1 month postoperatively the morphology of the flaps created with Femto LDV femtosecond lasers or Hansatome Microkeratome. The intended flap thickness was 110µm and 160µm respectively. The thickness of twenty-five points across each flap, which were 0mm, 1.5mm, 2.5mm, and 3.5mm to the corneal vertex on the horizontal, vertical, 45° and 135° meridian respectively, was evaluated. RESULTS: One month postoperative, the central flap thickness in the Femto LDV group was 107.43±4.70µm, while 125.90±17.50µm in the Hansatome group. The difference between the actual and the expected flap thickness was 5.61±3.84µm and 31.52±12.27µm, respectively. The Hansatome group had presented a statistically significant result (P<0.001). Flap morphology showed a more regular planar shape in the Femto LDV group and a meniscus shape in the Hansatome group. CONCLUSION: AS-OCT is a direct and fast procedure to assess the flap morphology. The morphology by AS-OCT showed that the flaps created with Femto LDV femtosecond laser were more accurate and regular than the flaps created with Hansatome microkeratome.

SELECTION OF CITATIONS
SEARCH DETAIL
...