Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Rev Med Pharmacol Sci ; 20(6): 1093-7, 2016.
Article in English | MEDLINE | ID: mdl-27049262

ABSTRACT

OBJECTIVE: The aim of the present study is to explore the mechanism of action of several proteins, including Epstein-Barr virus (EBV), B-cell lymphoma (Bcl)-2, p53, c-Myc and retinoblastoma (Rb), in Non-Hodgkin's lymphoma (NHL). PATIENTS AND METHODS: Between July 2010 and July 2015, samples of 142 patients with pathologically confirmed NHL which presented at our institution were included in the observation group. In addition, samples from 55 patients with hyperplastic lymphadenitis presented during the same period were enrolled as control group. The expressions of EBV (+), p53(+), Bcl-2(+), Rb(-) and c-Myc(+) were determined and compared PATIENTS AND METHODS: Between July 2010 and July 2015, samples of 142 patients with pathologically confirmed NHL which presented at our institution were included in the observation group. In addition, samples from 55 patients with hyperplastic lymphadenitis presented during the same period were enrolled as control group. The expressions of EBV (+), p53(+), Bcl-2(+), Rb(-) and c-Myc(+) were determined and compared among different subtypes and stages of NHLs of observation group. Besides, the correlation of EBV with p53, Bcl-2, Rb and c-Myc were investigated in NHLs of observation group. RESULTS: In the observation group, the expression rates of EBV(+), p53(+), Bcl-2(+), Rb(-), and c-Myc(+) were significantly higher than those, respectively, in the control group (p < 0.05). No significant correlation was observed between EBV expression and the expressions of p53, Bcl-2, Rb and c-Myc in the observation group (p > 0.05). The expression rates of p53(+) and Bcl-2(+) were significantly higher in aggressive and highly-aggressive NHLs than in indolent NHLs of the observation group (p < 0.05). The expressions of EBV(+), p53(+), Bcl-2(+), Rb(-), and c-Myc(+) were significantly higher in stage III-IV NHLs than in stage I-II NHLs (p < 0.05). CONCLUSIONS: The expressions of EBV(+), p53(+), Bcl-2(+), Rb(-), and c-Myc(+) are closely associated with NHL pathogenesis. Expressions of these proteins are higher in later stages of NHLs, and expressions of p53(+) and Bcl-2(+) are higher in more aggressive NHLs.


Subject(s)
Genes, p53/physiology , Herpesvirus 4, Human/metabolism , Lymphoma, Non-Hodgkin/metabolism , Proto-Oncogene Proteins c-bcl-2/biosynthesis , Proto-Oncogene Proteins c-myc/biosynthesis , Retinoblastoma Protein/biosynthesis , Adult , Female , Gene Expression Regulation, Neoplastic , Herpesvirus 4, Human/genetics , Humans , Lymphoma, Non-Hodgkin/diagnosis , Lymphoma, Non-Hodgkin/genetics , Male , Middle Aged , Proto-Oncogene Proteins c-bcl-2/genetics , Proto-Oncogene Proteins c-myc/genetics , Retinoblastoma Protein/genetics
2.
J Hazard Mater ; 285: 368-74, 2015 Mar 21.
Article in English | MEDLINE | ID: mdl-25528236

ABSTRACT

A surface acoustic wave (SAW) resonator with ZnO/SiO2 (ZS) composite film was used as an ammonia sensor in this study. ZS composite films were deposited on the surface of SAW devices using the sol-gel method, and were characterized using SEM, AFM, and XRD. The performance of the sensors under ammonia gas was optimized by adjusting the molar ratio of ZnO:SiO2 to 1:1, 1:2 and 1:3, and the sensor with the ratio of ZnO to SiO2 equaling to 1:2 was found to have the best performance. The response of sensor was 1.132 kHz under 10 ppm NH3, which was much higher than that of the sensor based on a pristine ZnO film. Moreover, the sensor has good selectivity, reversibility and stability at room temperature. These can be attributed to the enhanced absorption of ammonia and unique surface reaction on composite films due to the existence of silica.


Subject(s)
Ammonia/analysis , Silicon Dioxide/chemistry , Zinc Oxide/chemistry , Ammonia/chemistry , Sound
3.
Rev Sci Instrum ; 84(4): 045002, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23635225

ABSTRACT

A generic new data processing method is developed to accurately calculate the absolute optical path difference of a low-finesse Fabry-Perot cavity from its broadband interference fringes. The method combines Fast Fourier Transformation with nonlinear curve fitting of the entire spectrum. Modular functions of LabVIEW are employed for fast implementation of the data processing algorithm. The advantages of this technique are demonstrated through high performance fiber optic temperature sensors consisting of an infrared superluminescent diode and an infrared spectrometer. A high resolution of 0.01 °C is achieved over a large dynamic range from room temperature to 800 °C, limited only by the silica fiber used for the sensor.

SELECTION OF CITATIONS
SEARCH DETAIL
...