Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Am J Cardiol ; 222: 58-64, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38703883

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has emerged as an alternative treatment for patients with pure severe aortic regurgitation (PSAR) who are contraindicated for surgery or have a high surgical risk. However, the therapeutic efficacy and safety of TAVR in low Society of Thoracic Surgeons (STS) score risk patients remain to be clarified. This study aimed to explore the feasibility of TAVR treatment in different STS-risk patients and to compare the adverse events between the groups. In this study, patients with PSAR who underwent TAVR at Zhongshan Hospital, Fudan University, China, during the inclusion period were included and categorized into 3 groups based on STS scores. The baseline data, imaging results, and follow-up data of the patients were documented. Therefore, of 75 TAVR patients, 38 (50.7%) were categorized as low risk (STS <4), and 37 (49.3%) patients were categorized as intermediate and high risk (STS ≥4). Compared with patients at intermediate and high risk, those in the low-risk group were younger, had a lower body mass index, had a lower prevalence of hypertension, chronic obstructive pulmonary disease, and previous percutaneous coronary intervention, and had better cardiac function (p all <0.05). In the hospital and at the 1-month follow-up, the degree of aortic regurgitation and cardiac function were significantly improved. No significant difference was found between the 2 groups in the hospital or during the 30-day follow-up. In conclusion, TAVR for PSAR in low-STS-risk patients is safe and efficient during 30 days of follow-up compared with intermediate- and high-STS-risk groups. TAVR for PSAR should not be limited to inoperable or STS-defined high-risk patients. Long-term follow-up is needed for further investigation.

2.
Chinese Journal of Cardiology ; (12): 166-171, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-935122

ABSTRACT

Objective: To explore the short-term efficacy of fenestrated atrial septal defect (ASD) occulders in the treatment of pulmonary arterial hypertension (PAH). Methods: Thirty-six healthy dogs were divided into the balloon atrial septostomy (BAS)+fenestrated ASD occulders group (n=12), BAS group (n=12) and non-septostomy group (n=12). PAH was induced by intra-atrial injection of dehydrogenized monocrotaline (1.5 mg/kg) in all dogs. Animals in the BAS+fenestrated ASD occulders group underwent atrial septal puncture and fenestrated ASD occulders implantation. Animals in the BAS group underwent balloon atrial septostomy. The non-septostomy group received no surgical intervention. The hemodynamic indexes and blood N-terminal pro-B-type natriuretic peptide (NT-proBNP) of dogs were measured before modeling, 2 months after modeling, 1, 3, and 6 months after surgery, respectively. Echocardiography was performed to observe the patency of the shunt and atrial septostomy of the dogs in the BAS+fenestrated ASD occulders group and BAS group at 1, 3, and 6 months after surgery. Three dogs were sacrificed in each group at 1, 3, and 6 months after surgery, respectively. Atrial septal tissue and fenestrated ASD occulders were removed to observe the patency and endothelialization of the device. Lung tissues were obtained for hematoxylin-eosin (HE) staining to observe the inflammatory cells infiltration and the thickening and narrowing of the pulmonary arterials. Results: Among 36 dogs, 2 dogs died within 24 hours after modeling, and 34 dogs were assigned to BAS+fenestrated ASD occulders group (n=12), BAS group (n=11), and non-septostomy group (n=11). Compared with BAS group, the average right atrial pressure (mRAP) and NT-proBNP of dogs in the BAS+fenestrated ASD occulders group were significantly reduced at 3 months after surgery (P<0.05), and the cardiac output (CO) was significantly increased at 6 months after surgery, arterial oxygen saturation (SaO2) was also significantly reduced (P<0.05). Compared with non-septostomy group, dogs in the BAS+fenestrated ASD occulders group had significantly lower mRAP and NT-proBNP at 1, 3, and 6 months after surgery (P<0.05), and higher CO and lower SaO2 at 6 months after surgery (P<0.05). Compared with the non-septostomy group, the dogs in the BAS group had significantly lower mRAP and NT-proBNP at 1 month after surgery (P<0.05), and there was no significant difference on mRAP and NT-proBNP at 3 and 6 months after surgery (P>0.05). Echocardiography showed that there was a minimal right-to-left shunt in the atrial septum in the BAS group at 1 month after the surgery, and the ostomy was closed in all the dogs in the BAS group at 3 months after the surgery. There was still a clear right-to-left shunt in the dogs of BAS+fenestrated ASD occulders group. The shunt was well formed and satisfactory endothelialization was observed at 1, 3 and 6 months after surgery. The results of HE staining showed that the pulmonary arterials were significantly thickened, stenosis and collapse occurred in the non-septostomy group. Pulmonary microvascular stenosis and inflammatory cell infiltration in the pulmonary arterials were observed in the non-septostomy group. Pulmonary arterial histological results were comparable between BAS+fenestrated ASD occulders group and non-septostomy group at 6 months after surgery . Conclusions: The fenestrated ASD occulder has the advantage of maintaining the open fistula hole for a longer time compared with simple balloon dilation. The fenestrated ASD occulder can improve cardiac function, and it is safe and feasible to treat PAH in this animal model.


Subject(s)
Animals , Dogs , Atrial Septum/surgery , Cardiac Catheterization/methods , Familial Primary Pulmonary Hypertension , Heart Septal Defects, Atrial/surgery , Hypertension, Pulmonary , Pulmonary Arterial Hypertension
3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-695805

ABSTRACT

Objective To evaluate the long-term efficacy of percutaneous pulmonary valve implantation (PPVI) and the durability of the home-made self-expanding pulmonary valve (Venus-P).Methods From May,2013 to Nov.,2015,14 patients who underwent percutaneous pulmonary valve implantation at Zhongshan Hospital,Fudan University and received at least 1 year follow-up were enrolled,including 3 males and 11 females,with an average age of (35.8 ± 7.8) years.All patients with tetralogy of Fallot received radical resection and developed severe pulmonary regurgitation.The longterm mortality,the operation related complications,the short term and long-term effect of PPVI,as well as the durability and effect of the self-expanding pulmonary valve were evaluated in the 14 patients.Results Over an average follow-up period of (2.3 ± 0.8) years (1.0-3.5 years),only 1 patient died (6.7 %).During the follow-up,no deterioration,infective endocarditis,malignant arrhythmia and other serious complications was observed,and nobody needed reoperation.There was no valve displacement,valve stent fracture,obvious circumferential leakage and pulmonary regurgitation.After PPVI,an acute improvement in pulmonary artery diastolic pressure was observed [(4.93 ± 3.37) mmHg vs.(11.47 ± 4.61) mmHg,P<0.05].Six month postoperatively,right ventricular end diastolic volume measured by cardiac nuclear magnetic resonance was significantly reduced [(139.29± 18.21)mL/m2 vs.(83.03 ± 20.0) mL/m2,P<0.05].At 1 year follow up,the across valve pressure difference were (20.85 ± 4.45) mmHg calculated by the echocardiography,and the NYHA cardiac function (Ⅰ-Ⅲ:4 cases;Ⅰ-Ⅱ:10 cases) was improved 1-2 degree and the distance of 6-minute walk test were significantly increased [(475.00 ± 55.06) m vs.(594.23 ± 194.51) m,P<0.05].Meanwhile,the QRS duration decreased was also observed.The changes of the QRS duration have statistical significance after 1 and 3 months of the PPVI when compared with the baseline [(169.93 ± 21.34) ms vs.(159.87 ± 24.4) ms or (160.00 ± 27.0 ms,P<0.05].Conclusions PPVI using home-made self-expanding pulmonary valve (Venus-P) for chronic pulmonary regurgitation has good long-term efficacy and low complication rate,and the valve is durable.

SELECTION OF CITATIONS
SEARCH DETAIL
...