1.
Osteoporos Int ; 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39129009

ABSTRACT

This study aimed to evaluate the correlation between measuring proton-density fat fraction (PDFF) in bone marrow using multi-echo chemical shift-encoded MRI and osteoporosis, assessing its effectiveness as a biomarker for osteoporosis. A systematic review was conducted by two independent researchers using Cochrane, PubMed, EMBASE, and Web of Science databases up to December 2023. Quality assessments were evaluated using the Cochrane risk of bias tool and the Agency for Healthcare Research and Quality (AHRQ) checklist. Fourteen studies involving 1495 patients were analyzed. The meta-analysis revealed a significant difference in PDFF values between the osteoporosis/osteopenia group and the normal control group, with a mean difference of 11.04 (95% CI: 9.17 to 12.92, Z=11.52, P < 0.00001). Measuring PDFF via MRI shows potential as an osteoporosis biomarker and may serve as a risk factor for osteoporosis. This insight opens new avenues for future diagnostic and therapeutic strategies, potentially improving osteoporosis management and patient care. OBJECTIVE: This study aims to assess the correlation between measuring proton-density fat fraction (PDFF) in bone marrow using multi-echo chemical shift-encoded MRI and osteoporosis, evaluating its effectiveness as a biomarker for osteoporosis. MATERIALS AND METHODS: This systematic review was carried out by two independent researchers using Cochrane, PubMed, EMBASE, and Web of Science databases up to December 2023. Quality assessments were evaluated using the Cochrane risk of bias tool and the Agency for Healthcare Research and Quality (AHRQ) checklist. RESULTS: Fourteen studies involving 1495 patients were analyzed. The meta-analysis revealed a significant difference in PDFF values between the osteoporosis/osteopenia group and the normal control group, with a (MD = 11.04, 95% CI: 9.17 to 12.92, Z = 11.52, P < 0.00001). Subgroup analyses indicated that diagnostic methods, gender, and echo length did not significantly impact the PDFF-osteoporosis association. CONCLUSION: PDFF measurement via MRI shows potential as an osteoporosis biomarker and may serve as a risk factor for osteoporosis. This insight opens new avenues for future diagnostic and therapeutic strategies, potentially improving osteoporosis management and patient care.

2.
Med Phys ; 2024 Jul 14.
Article in English | MEDLINE | ID: mdl-39003592

ABSTRACT

BACKGROUND: Magnetoencephalography (MEG) and magnetic resonance imaging (MRI) are non-invasive imaging techniques that offer effective means for disease diagnosis. A more straightforward and optimized method is presented for designing gradient coils which are pivotal parts of the above imaging systems. PURPOSE: A novel design method based on stream function combining an optimization algorithm is proposed to obtain highly linear gradient coil. METHODS: Two-dimensional Fourier expansion of the current field on the surface where the coil is located and the equipotential line of the expansion term superposition according to the number of turns of the coil are used to represent the coil shape. Particle swarm optimization is utilized to optimize the coil shape while linearity and field uniformity are used as parameters to evaluate the coil performance. Through this method, the main parameters such as input current distribution region, coil turns, desired magnetic field strength, expansion order and iteration times can be combined in a given solution space to optimize coil design. RESULTS: Simulation results show that the maximum linearity spatial deviation of the designed bi-planar x-gradient coil compared with that of target field method is reduced from 14% to 0.54%, and that of the bi-planar z-gradient coil is reduced from 8.98% to 0.52%. Similarly, that of the cylindrical x-gradient coil is reduced from 2% to 0.1%, and that of the cylindrical z-gradient coil is reduced from 0.87% to 0.45%. The similar results are found in the index of inhomogeneity error. Moreover, it has also been verified experimentally that the result of measured magnetic field is consist with simulated result. CONCLUSIONS: The proposed method provides a straightforward way that simplifies the design process and improves the linearity of designed gradient coil, which could be beneficial to realize better magnetic field in engineering applications.

3.
J Magn Reson ; 357: 107579, 2023 12.
Article in English | MEDLINE | ID: mdl-37949007

ABSTRACT

With the incidence of breast cancer rising to the top among female malignant tumors, magnetic resonance images guided breast biopsy intervention and minimally invasive treatment have developed as a clinically practical research issue. High field studies have shown the diagnostic value of breast MRI, but the examination costs greatly exceed those of competing conventional mammography. In this case, low-field MRI cannot merely provide typical MRI contrast, but also significantly reduce the cost of diagnosis and treatment for breast cancer patients. This work describes a unilateral breast coil and prototype intervention device, which provides a customized solution for low-field MRI-guided breast intervention. Results demonstrate that the low-field MRI breast intervention device facilitates medical intervention procedures. And the designed positioning device can locate the target lesion within 2-3 mm accuracy. Phantom tests with the customized unilateral coil indicate that the open loops perform as well as the 4-channel commercial closed breast coil, presenting a relatively good SNR (signal-to-noise ratio) and uniformity characteristics. MR scanning images of the volunteer breast using the breast intervention coil also show high SNR, which lays a foundation for further implementation of image-guided breast interventional minimally invasive surgery with the low-field MRI system.


Subject(s)
Breast Neoplasms , Breast , Female , Humans , Breast/diagnostic imaging , Breast/surgery , Magnetic Resonance Imaging/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Signal-To-Noise Ratio , Phantoms, Imaging
4.
Magn Reson Med ; 88(4): 1886-1900, 2022 10.
Article in English | MEDLINE | ID: mdl-35775830

ABSTRACT

PURPOSE: To develop an MR-conditional microwave needle that generates a spherical ablation zone and clear MRI visibility for MR-guided microwave ablation. METHODS: An MR-conditional microwave needle consisting of zirconia tip and TA18 titanium alloy tube was investigated. The numerical model was created to optimize the needle's geometry and analyze its performance. A geometrically optimized needle was produced using non-magnetic materials based on the electromagnetics simulation results. The needle's mechanical properties were tested per the Chinese pharmaceutical industry standard YY0899-2013. The MRI visibility performance and ablation characteristics of the needle was tested both in vitro (phantom) and in vivo (rabbit) at 1.5T. The RF-induced heating was evaluated in ex vivo porcine liver. RESULTS: The needle's mechanical properties met the specified requirements. The needle susceptibility artifact was clearly visible both in vitro and in vivo. The needle artifact diameter (A) was small in in vivo (Ashaft: 4.96 ± 0.18 mm for T1W-FLASH, 3.13 ± 0.05 mm for T2-weighted fast spin-echo (T2W-FSE); Atip: 2.31 ± 0.09 mm for T1W-FLASH, 2.29 ± 0.08 mm for T2W-FSE; tip location error [TLE]: -0.94 ± 0.07 mm for T1W-FLASH, -1.10 ± 0.09 mm for T2W-FSE). Ablation zones generated by the needle were nearly spherical with an elliptical aspect ratio ranging from 0.79 to 0.90 at 30 W, 50 W for 3, 5, 10 min duration ex vivo ablations and 0.86 at 30 W for 10 min duration in vivo ablations. CONCLUSION: The designed MR-conditional microwave needle offers excellent mechanical properties, reliable MRI visibility, insignificant RF-induced heating, and a sufficiently spherical ablation zone. Further clinical development of MR-guided microwave ablation appears warranted.


Subject(s)
Ablation Techniques , Catheter Ablation , Ablation Techniques/methods , Animals , Artifacts , Catheter Ablation/methods , Liver/diagnostic imaging , Liver/surgery , Magnetic Resonance Imaging , Microwaves/therapeutic use , Phantoms, Imaging , Rabbits , Swine