Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 31(22): 36171-36187, 2023 Oct 23.
Article in English | MEDLINE | ID: mdl-38017772

ABSTRACT

Infrared image super-resolution technology aims to overcome the pixel size limitation of the infrared focal plane array for higher resolution images. Due to the real-world images with different resolutions having more complex degradation processes than mathematical calculation, most existing super-resolution methods using the synthetic data obtained by bicubic interpolation achieve unsatisfactory reconstruction performance in real-world scenes. To solve this, this paper innovatively proposes an infrared real-world dataset with different resolutions based on a refrigerated thermal detector and the infrared zoom lens, enabling the network to acquire more realistic details. We obtain images under different fields of view by adjusting the infrared zoom lens and then achieve the scale and luminance alignment of high and low-resolution (HR-LR) images. This dataset can be used for infrared image super-resolution, with an up-sampling scale of two. In order to learn complex features of infrared images efficiently, an asymmetric residual block structure is proposed to effectively reduce the number of parameters and improve the performance of the network. Finally, to solve the slight misalignment problem in the pre-processing stage, contextual loss and perceptual loss are introduced to improve the visual performance. Experiments show that our method achieves superior results both in reconstruction effect and practical value for single infrared image super-resolution in real scenarios.

2.
Sci Adv ; 8(1): eabl9174, 2022 Jan 07.
Article in English | MEDLINE | ID: mdl-34995111

ABSTRACT

We report analysis results of the reflectance spectra (0.48 to 3.2 µm) acquired by the Chang'E-5 lander, which provides vital context of the returned samples from the Northern Oceanus Procellarum of the Moon. We estimate up to 120 parts per million (ppm) of water (OH + H2O) in the lunar regolith, which is mostly attributed to solar wind implantation. A light-colored and surface-pitted rock (named as CE5-Rock) is evident near the lander. The reflectance spectra suggest that CE5-Rock could be transported from an older basalt unit. CE5-Rock exhibits a stronger absorption, near 2.85 µm, than the surrounding regolith, with estimation of ~180 ppm of water if the model for estimating water content of regolith is applicable to rock samples, which may suggest an additional source from the lunar interior. The low water content of the regolith may suggest the degassing of mantle reservoir beneath the Chang'E-5 landing site.

3.
Opt Express ; 27(13): 17686-17700, 2019 Jun 24.
Article in English | MEDLINE | ID: mdl-31252725

ABSTRACT

We have focused on the optical form that is low cost while maintaining high performance for airborne application. We report the optical design as well as the alignment and test results for a push-broom imaging spectrometer. The smart architecture of the prism-grating based spectrometer ensures high uniformity and image quality. Moreover, an effective method for aligning the spectrometer is also proposed. The results of laboratory-based optical tests and a flight test confirm the easy manufacture and excellent performance. Thus, the proposed system should be suitable for use as a hyperspectral instrument that can be loaded onto airborne and unmanned aerial vehicles.

4.
Sensors (Basel) ; 19(12)2019 Jun 22.
Article in English | MEDLINE | ID: mdl-31234545

ABSTRACT

The Chang'e-4 (CE-4) lunar rover, equipped with a visible and near-IR imaging spectrometer (VNIS) based on acousto-optic tunable filter spectroscopy, was launched to the far side of the moon on December 8, 2018. The detection band of the VNIS ranges from 0.45 to 2.4 µm. Because of the weak reflection of infrared radiation from the lunar surface, a static electronic phase-locked acquisition method is adopted in the infrared channel for signal amplification. In this paper, full-link simulations and modeling are conducted on the infrared channel information flow of the instrument. The signal characteristics of the VNIS are analyzed in depth, and the signal to noise ratio (SNR) prediction and laboratory verification are presented. On 4 January 2019, the VNIS started working successfully and acquired high-resolution spectrum data of the far side of the moon for the first time. Through analysis we have found that the SNR ratio is in line with our predictions, and the data obtained by VNIS in orbit are consistent with the information model proposed in this paper.

5.
Sensors (Basel) ; 19(7)2019 Apr 08.
Article in English | MEDLINE | ID: mdl-30965579

ABSTRACT

Wide Swath and High Resolution Airborne Pushbroom Hyperspectral Imager (WiSHiRaPHI) is the new-generation airborne hyperspectral imager instrument of China, aimed at acquiring accurate spectral curve of target on the ground with both high spatial resolution and high spectral resolution. The spectral sampling interval of WiSHiRaPHI is 2.4 nm and the spectral resolution is 3.5 nm (FWHM), integrating 256 channels coving from 400 nm to 1000 nm. The instrument has a 40-degree field of view (FOV), 0.125 mrad instantaneous field of view (IFOV) and can work in high spectral resolution mode, high spatial resolution mode and high sensitivity mode for different applications, which can adapt to the Velocity to Height Ratio (VHR) lower than 0.04. The integration has been finished, and several airborne flight validation experiments have been conducted. The results showed the system's excellent performance and high efficiency.

6.
Appl Opt ; 56(30): 8501-8506, 2017 Oct 20.
Article in English | MEDLINE | ID: mdl-29091631

ABSTRACT

We studied the polarization evolution of a reflective telescope designed for the quantum satellite Micius. The change in polarization extinction ratio (PER) of quantum light was derived and calculated. The PER deterioration caused by increase of incidence angle was calculated to determine the boundary conditions for the system design. The performance of the Micius prototype was evaluated both theoretically and experimentally to verify the viability of our optical design. Minimum and maximum PERs of 38 and 55 dB, respectively, were recorded, which were mostly in good agreement with the numerical calculations. Our investigations have contributed to the success of Micius, which is a significant milestone for building a global security network.

7.
Opt Express ; 25(19): 22440-22454, 2017 Sep 18.
Article in English | MEDLINE | ID: mdl-29041554

ABSTRACT

We discuss and evaluate a long wave infrared imaging spectrometer in terms of its opto-mechanical design and analysis, alignment, testing, and calibration. The instrument is a practical airborne sensor achieving high spectral resolution and sensitive noise equivalent delta temperature. The instrument operates in the 8 to 12.5 µm spectral region with 28.85 nm spectral sampling, 1 mrad instantaneous field of view, and >40° cross track field. The instrument comprises three uniform sub-modules with identical design parameters and performances. The sub-module design is based on a refractive foreoptics feeding an all-reflective spectrometer. The optical form of the spectrometer is a double-pass reflective triplet with a flat grating, which has a fast f/2 and high optical throughput. Cryogenic optics of 100 K is implemented only for the spectrometer. Assembly and thermal deformation and focusing adjustment design are particularly considered for this low temperature. All the mirrors of the spectrometer are opto-mechanical-integrated designed and manufactured by single-point diamond turning technology. We consider the center sub-module as an example, and we present its laboratory testing results and calibration; the results indicate the instrument's potential value in airborne sensing.

SELECTION OF CITATIONS
SEARCH DETAIL
...