Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Bioanal Chem ; 415(8): 1477-1485, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36680590

ABSTRACT

Hexavalent chromium is a highly toxic substance, which will pose a serious threat to human life and health and the entire ecosystem. Therefore, it is crucial to establish a simple and rapid detection method for hexavalent chromium. In this work, we fabricated bovine serum albumin-stabilized silver nanocluster (BSA-Ag13 NC) which exhibited photoresponsive oxidase-like activity, catalyzing the oxidation of colorless 3,3',5,5'-tetramethylbenzidine (TMB) to the blue oxidized state TMB (oxTMB) in a short time. Interestingly, 8-hydroxyquinoline (8-HQ) can significantly inhibit the color reaction of TMB oxidation while Cr(VI) can interact specifically with 8-HQ to restore this chromogenic reaction. Based on the above facts, a colorimetric sensing system for detecting Cr(VI) was developed. The sensing system shows a wide linear range, and good selectivity, with a low detection limit of 2.32 nM. Moreover, this sensing system could be successfully applied to the detection of Cr(VI) in lake water, tap water, and sewage with satisfactory results.


Subject(s)
Colorimetry , Silver , Humans , Colorimetry/methods , Ecosystem , Water , Limit of Detection
2.
J Colloid Interface Sci ; 631(Pt A): 86-95, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36368217

ABSTRACT

Carbon nitride (C3N4) nanosheets are known as peroxidase mimics, but the low activity hinders their further application. Embedding active metal nanoparticles onto the C3N4 nanosheets is expected to break this limitation. Herein, highly dispersed ultrasmall Ru nanoparticles are anchored onto the C3N4 through spontaneous redox reaction. The as-obtained Ru-C3N4 exhibits excellent peroxidase-like activity, which can be further regulated by adjusting the loading of Ru nanoparticles on C3N4. Using Ru-C3N4 as a mimetic peroxidase, a colorimetric sensing method for alkaline phosphatase (ALP) detection is developed based on the inhibitory effect of ascorbic acid produced by hydrolysis of ALP and l-ascorbic acid 2-phosphate (AAP) on the color development reaction of TMB catalyzed by Ru-C3N4. The sensor exhibits wide linear range and low detection limit for the ALP sensing. Finally, the assay is applied to ALP detection in human serum and satisfactory results are obtained, which provides a promising strategy for colorimetric sensing of ALP.


Subject(s)
Colorimetry , Metal Nanoparticles , Humans , Alkaline Phosphatase , Colorimetry/methods , Coloring Agents , Limit of Detection , Peroxidase , Peroxidases , Molecular Mimicry
3.
J Orthop Surg Res ; 16(1): 633, 2021 Oct 21.
Article in English | MEDLINE | ID: mdl-34674736

ABSTRACT

BACKGROUND: Which technique, gap balancing or measured resection, can obtain better femoral component alignment and soft tissue balance in total knee arthroplasty (TKA) is still controversial. This study aimed to determine whether the gap balancing technique using a modified spacer block in TKA can result in better postoperative clinical outcomes than the measured resection technique. METHODS: A total of 124 patients who underwent consecutive primary TKA between May 2016 and August 2018 were retrospectively reviewed. The gap balancing technique assisted by a modified spacer block was used in 61 patients, and the measured resection technique was used in 63 patients. The surgical, imaging and knee function outcomes of the two groups were compared. RESULTS: The thickness of the posterior medial condyle bone resection using the modified spacer block tool in gap balancing was significantly larger than that of the MR technique (P = 0.001). Compared with the measured resection group, the gap balancing group had a greater external rotation resection angle of the femur (4.06 ± 1.10° vs. 3.19 ± 0.59°, P < 0.001°). Despite these differences, the mean ROM, KSS scores, and WOMAC scores at the 6-week, 1-year, and 2-year follow-ups were not significantly different. Postoperatively, there was no significant difference between the two groups in mechanical axis measurements (P = 0.275), the number of HKA outliers (P = 0.795) or the joint line displacement (P = 0.270). CONCLUSION: The functional outcomes of the gap balancing technique based on the modified spacer are similar to those of measured resection at 3 years. Compared with the MR technique, the GB technique resulted in a greater external rotation resection angle and thicker posterior medial condylar cuts in TKA with knee varus.


Subject(s)
Arthroplasty, Replacement, Knee , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Retrospective Studies
4.
Ann Transl Med ; 7(22): 659, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31930060

ABSTRACT

BACKGROUND: This prospective study aimed to compare the efficacy of a novel, hand-held, accelerometer-based navigation system (i-JOIN knee navigation system) for distal femoral resection in total knee arthroplasty (TKA) with conventional instrument. METHODS: A multi-center, double-blinded, randomized controlled trial (RCT) was conducted. A total of 79 consecutive patients scheduled for primary TKA were enrolled and divided into navigation group (39 patients) and conventional group (40 patients). Post-operative mechanical and component position were evaluated through full-leg weight bearing X-ray. Pre-operatively and 1 week post-operatively, adverse events were recorded. Intraoperative surgical time and blood loss were also recorded. RESULTS: The mean outlier of 180° neutral mechanical axis was 1.60° (SD 1.11°) in navigation group and 2.30° (SD 2.06°) in conventional group (P=0.0917). Thirty-eight patients (97.4%) in navigation group and 35 patients (87.5%) in conventional group had an alignment which was ≤3°away from the neutral mechanical axis (P=0.2007). α angle between the navigation group and conventional group was not statistically different (89.81° vs. 89.76°, P>0.05), as well as adverse events rate post-operatively. The operative time of navigation group was significantly longer than that of control group (114.54±35.34 vs. 100.33±28.38 min, P=0.0493), whereas the intraoperative blood loss was not significantly different. CONCLUSIONS: i-JOIN knee navigation system had equivalent results for distal femoral resection in TKA compared with the conventional technique.

5.
BMC Musculoskelet Disord ; 17(1): 344, 2016 08 15.
Article in English | MEDLINE | ID: mdl-27528281

ABSTRACT

BACKGROUND: Multiple small drilling for core decompression is widely used to preserve the femoral head in patients with avascular necrosis of the femoral head (ANFH). Nevertheless, the clinical outcome remains controversial. Simvastatin has been demonstrated to promote bone formation and reduce bone adsorption. The purpose of this study was to determine whether simvastatin enhanced the effect of multiple decompressions in preventing progression of ANFH and to identify independent risk factors associated with poor results. METHODS: We retrospectively analyzed 58 hips in 36 patients, with a follow-up of 36 months. 20 patients (32 hips) underwent multiple drilling combined with simvastatin treatment (SIM group); 16 patients (26 hips) underwent multiple drilling alone (MD group). We defined clinical failure as a requirement for subsequent hip surgery or Harris Hip Score < 75. New occurrence of collapse or increased collapse > 2 mm on plain radiographs was defined as radiological failure. RESULTS: Successful clinical results were achieved in 27 of 32 hips (84 %) in the SIM group compared with 15 of 26 hips (58 %) in the MD group (OR = 0.2, CI (0.1, 0.6.), P = 0.032). Successful radiological results were achieved in 27 of 32 hips (84 %) in the SIM group and in 16 of 26 hips (61.5 %) in the MD group (P = 0.048). Body mass index, disease stage and location of lesion were independent prognostic factors for overall survival. CONCLUSIONS: We believe that simvastatin could enhance the effects of multiple decompressions in preventing progression of ANFH and reducing the risk of femoral head collapse.


Subject(s)
Decompression, Surgical/methods , Femur Head Necrosis/therapy , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Osteogenesis/drug effects , Simvastatin/therapeutic use , Adult , Body Mass Index , Combined Modality Therapy/methods , Decompression, Surgical/adverse effects , Disease Progression , Female , Femur Head/pathology , Femur Head/surgery , Follow-Up Studies , Hip , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/adverse effects , Male , Middle Aged , Prognosis , Radiography , Reoperation/statistics & numerical data , Retrospective Studies , Risk Factors , Simvastatin/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...