Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Hosp Infect ; 149: 26-35, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38705476

ABSTRACT

BACKGROUND: The environmental surveillance of air grilles in clinical areas has not been systematically analysed. METHODS: Samples were collected from frequently touched items (N = 529), air supply (N = 295) and exhaust (N = 184) grilles in six medical and 11 surgical wards for the cultures of multi-drug-resistant organisms (MDROs): meticillin-resistant Staphylococcus aureus (MRSA), carbapenem-resistant Acinetobacter baumannii (CRAB) and carbapenemase-producing Enterobacterales (CPE), and isolates were selected for whole-genome sequencing (WGS). The contamination rates were correlated with the colonization pressures of the respective MDROs. RESULTS: From 3rd October to 21st November 2023, 9.8% (99/1008) of the samples tested positive, with MRSA (24.2%, 24/99), CRAB (59.6%, 59/99) and CPE (2.0%, 2/99), being the only detected MDROs. The contamination rate in air exhaust grilles (26.6%, 49/184) was significantly higher than in air supply grilles (5.8%, 17/295; P<0.001). The contamination rate of air exhaust grilles with any MDRO in acute medical wards (73.7%, 14/19) was significantly higher than in surgical wards (12.5%, 4/32; P<0.001). However, there was no difference in the contamination rate of air exhaust grilles between those located inside and outside the cohort cubicles for MDROs (27.1%, 13/48 vs 28.8%, 30/104; P=0.823). Nevertheless, the weekly CRAB colonization pressure showed a significant correlation with the overall environmental contamination rate (r = 0.878; 95% confidence interval (CI): 0.136-0.986; P=0.004), as well as with the contamination rate in air supply grilles (r = 0.960; 95% CI: 0.375-0.999; P<0.001) and air exhaust grilles (r = 0.850; 95% CI: 0.401-0.980; P=0.008). WGS demonstrated clonal relatedness of isolates collected from patients and air exhaust grilles. CONCLUSIONS: Air grilles may serve as MDRO reservoirs. Cohort nursing in open cubicles may not completely prevent MDRO transmission through air dispersal, prompting the consideration of future hospital design.

3.
J Hosp Infect ; 123: 52-60, 2022 May.
Article in English | MEDLINE | ID: mdl-35196559

ABSTRACT

BACKGROUND: Meticillin-resistant Staphylococcus aureus (MRSA) infections are rampant in hospitals and residential care homes for the elderly (RCHEs). AIM: To analyse the prevalence of MRSA colonization among residents and staff, and degree of environmental contamination and air dispersal of MRSA in RCHEs. METHODS: Epidemiological and genetic analysis by whole-genome sequencing (WGS) in 12 RCHEs in Hong Kong. FINDINGS: During the COVID-19 pandemic (from September to October 2021), 48.7% (380/781) of RCHE residents were found to harbour MRSA at any body site, and 8.5% (8/213) of staff were nasal MRSA carriers. Among 239 environmental samples, MRSA was found in 39.0% (16/41) of randomly selected resident rooms and 31.3% (62/198) of common areas. The common areas accessible by residents had significantly higher MRSA contamination rates than those that were not accessible by residents (37.2%, 46/121 vs. 22.1%, 17/177, P=0.028). Of 124 air samples, nine (7.3%) were MRSA-positive from four RCHEs. Air dispersal of MRSA was significantly associated with operating indoor fans in RCHEs (100%, 4/4 vs. 0%, 0/8, P=0.002). WGS of MRSA isolates collected from residents, staff and environmental and air samples showed that ST 1047 (CC1) lineage 1 constituted 43.1% (66/153) of all MRSA isolates. A distinctive predominant genetic lineage of MRSA in each RCHE was observed, suggestive of intra-RCHE transmission rather than clonal acquisition from the catchment hospital. CONCLUSION: MRSA control in RCHEs is no less important than in hospitals. Air dispersal of MRSA may be an important mechanism of dissemination in RCHEs with operating indoor fans.


Subject(s)
COVID-19 , Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections , Aged , COVID-19/epidemiology , Carrier State/epidemiology , Humans , Methicillin , Methicillin-Resistant Staphylococcus aureus/genetics , Pandemics , Staphylococcal Infections/epidemiology
4.
J Hosp Infect ; 116: 78-86, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34403765

ABSTRACT

AIM: To describe the nosocomial transmission of Air, multidrug-resistant, Acinetobacter baumannii, nosocomial, COVID-19 Acinetobacter baumannii (MRAB) in an open-cubicle neurology ward with low ceiling height, where MRAB isolates collected from air, commonly shared items, non-reachable high-level surfaces and patients were analysed epidemiologically and genetically by whole-genome sequencing. This is the first study to understand the genetic relatedness of air, environmental and clinical isolates of MRAB in the outbreak setting. FINDINGS: Of 11 highly care-dependent patients with 363 MRAB colonization days during COVID-19 pandemic, 10 (90.9%) and nine (81.8%) had cutaneous and gastrointestinal colonization, respectively. Of 160 environmental and air samples, 31 (19.4%) were MRAB-positive. The proportion of MRAB-contaminated commonly shared items was significantly lower in cohort than in non-cohort patient care (0/10, 0% vs 12/18, 66.7%; P<0.001). Air dispersal of MRAB was consistently detected during but not before diaper change in the cohort cubicle by 25-min air sampling (4/4,100% vs 0/4, 0%; P=0.029). The settle plate method revealed MRAB in two samples during diaper change. The proportion of MRAB-contaminated exhaust air grills was significantly higher when the cohort cubicle was occupied by six MRAB patients than when fewer than six patients were cared for in the cubicle (5/9, 55.6% vs 0/18, 0%; P=0.002). The proportion of MRAB-contaminated non-reachable high-level surfaces was also significantly higher when there were three or more MRAB patients in the cohort cubicle (8/31, 25.8% vs 0/24, 0%; P=0.016). Whole-genome sequencing revealed clonality of air, environment, and patients' isolates, suggestive of air dispersal of MRAB. CONCLUSIONS: Our findings support the view that patient cohorting in enclosed cubicles with partitions and a closed door is preferred if single rooms are not available.


Subject(s)
Acinetobacter Infections , Acinetobacter baumannii , COVID-19 , Cross Infection , Acinetobacter Infections/drug therapy , Acinetobacter Infections/epidemiology , Acinetobacter baumannii/genetics , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Cross Infection/drug therapy , Cross Infection/epidemiology , Drug Resistance, Multiple, Bacterial , Humans , Microbial Sensitivity Tests , Pandemics , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...