ABSTRACT
An improved strategy for compound identification incorporating gas chromatography hyphenated with Fourier transform infrared spectroscopy and mass spectroscopy (GC-FTIR/MS) is reported. (Over)reliance on MS may lead either to ambiguous identity or to incorrect identification of a compound. However, the MS result is useful to provide a cohort of possible compounds. The IR result for each tentative compound match was then simulated using molecular modeling, to provide functional group and isomer differentiation information, and then compared with the experimental FTIR result, offering identification based on both MS and IR. Several basis sets were evaluated for IR simulations; Def2-TZVPP was a suitable basis set and correlated well with experimental data. The approach was applied to industrial applications, confirming the isomers of 2,3-bis(thiosulfanyl)-but-2-enedinitrile, bromination products of 1-bromo-2,3-dimethylbenzene, and autoxidative degradation of phenyl-di-tert-butylphosphine.
Subject(s)
Gas Chromatography-Mass Spectrometry , Humans , Isomerism , Mass Spectrometry , Spectrophotometry, Infrared , Spectroscopy, Fourier Transform InfraredABSTRACT
This study reports gas chromatography (GC) combined with Fourier transform infrared (FTIR) spectroscopy to investigate the elution profiles of individual oxime isomers undergoing characteristic interconversion (dynamic chromatography) in GC. The use of a light-pipe FTIR interface enables on-line acquisition of FTIR spectra, which in turn render unambiguous identification of the individual molecules. Here, acetaldehyde oxime and propionaldehyde oxime were chosen for comparison of elution behaviour under varying temperature and carrier flow velocities. The choice of selective responses (wavenumber selectivity), which were relatively stronger for each isomer, enabled display and retracing of the individual isomer over the chromatographic time scale and thus provided characteristic single isomer profiles. Chemometric data analysis using the multivariate curve resolution technique further confirmed this isomer elution profile. Simulation of the spectrum for each isomer allowed comparison with instrument-generated FTIR spectra to confirm the elution order of E and Z isomers. The effect of changing chromatographic parameters (temperature, flow) on interconversion rates and/or extents were studied and the corresponding change in FTIR spectrum intensity was noted. The GC-FID data acquired concurrently with GC-FTIR analyses ratified isomerisation chromatographic profiles.