Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 157
Filter
1.
J Appl Clin Med Phys ; : e14338, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38610118

ABSTRACT

PURPOSE: Volumetric-modulated arc therapy (VMAT) is a widely accepted treatment method for head and neck (HN) and cervical cancers; however, creating contours and plan optimization for VMAT plans is a time-consuming process. Our group has created an automated treatment planning tool, the Radiation Planning Assistant (RPA), that uses deep learning models to generate organs at risk (OARs), planning structures and automates plan optimization. This study quantitatively evaluates the quality of contours generated by the RPA tool. METHODS: For patients with HN (54) and cervical (39) cancers, we retrospectively generated autoplans using the RPA. Autoplans were generated using deep-learning and RapidPlan models developed in-house. The autoplans were, then, applied to the original, physician-drawn contours, which were used as a ground truth (GT) to compare with the autocontours (RPA). Using a "two one-sided tests" (TOST) procedure, we evaluated whether the autocontour normal tissue dose was equivalent to that of the ground truth by a margin, δ, that we determined based on clinical judgement. We also calculated the number of plans that met established clinically accepted dosimetric criteria. RESULTS: For HN plans, 91.8% and 91.7% of structures met dosimetric criteria for automatic and manual contours, respectively; for cervical plans, 95.6% and 95.7% of structures met dosimetric criteria for automatic and manual contours, respectively. Autocontours were equivalent to the ground truth for 71% and 75% of common DVH metrics for the HN and cervix, respectively. CONCLUSIONS: This study shows that dosimetrically equivalent normal tissue contours can be created for HN and cervical cancers using deep learning techniques. In general, differences between the contours did not affect the passing or failing of clinical dose tolerances.

2.
JCO Glob Oncol ; 10: e2300376, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38484191

ABSTRACT

PURPOSE: Increased automation has been identified as one approach to improving global cancer care. The Radiation Planning Assistant (RPA) is a web-based tool offering automated radiotherapy (RT) contouring and planning to low-resource clinics. In this study, the RPA workflow and clinical acceptability were assessed by physicians around the world. METHODS: The RPA output for 75 cases was reviewed by at least three physicians; 31 radiation oncologists at 16 institutions in six countries on five continents reviewed RPA contours and plans for clinical acceptability using a 5-point Likert scale. RESULTS: For cervical cancer, RPA plans using bony landmarks were scored as usable as-is in 81% (with minor edits 93%); using soft tissue contours, plans were scored as usable as-is in 79% (with minor edits 96%). For postmastectomy breast cancer, RPA plans were scored as usable as-is in 44% (with minor edits 91%). For whole-brain treatment, RPA plans were scored as usable as-is in 67% (with minor edits 99%). For head/neck cancer, the normal tissue autocontours were acceptable as-is in 89% (with minor edits 97%). The clinical target volumes (CTVs) were acceptable as-is in 40% (with minor edits 93%). The volumetric-modulated arc therapy (VMAT) plans were acceptable as-is in 87% (with minor edits 96%). For cervical cancer, the normal tissue autocontours were acceptable as-is in 92% (with minor edits 99%). The CTVs for cervical cancer were scored as acceptable as-is in 83% (with minor edits 92%). The VMAT plans for cervical cancer were acceptable as-is in 99% (with minor edits 100%). CONCLUSION: The RPA, a web-based tool designed to improve access to high-quality RT in low-resource settings, has high rates of clinical acceptability by practicing clinicians around the world. It has significant potential for successful implementation in low-resource clinics.


Subject(s)
Breast Neoplasms , Uterine Cervical Neoplasms , Female , Humans , Breast Neoplasms/surgery , Artificial Intelligence , Uterine Cervical Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Mastectomy
3.
Physiol Behav ; 279: 114523, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38492912

ABSTRACT

Melatonin is a neurohormone synthesized by the pineal gland to regulate the circadian rhythms and has proven to be effective in treating drug addiction and dependence. However, the effects of melatonin to modulate the drug-seeking behavior of fentanyl and its underlying molecular mechanism is elusive. This study was designed to investigate the effects of melatonin on fentanyl - induced behavioral sensitization and circadian rhythm disorders in mice. The accompanying changes in the expression of Brain and Muscle Arnt-Like (BMAL1), tyrosine hydroxylase (TH), and monoamine oxidase A (MAO-A) in relevant brain regions including the suprachiasmatic nucleus (SCN), nucleus accumbens (NAc), prefrontal cortex (PFC), and hippocampus (Hip) were investigated by western blot assays to dissect the mechanism by which melatonin modulates fentanyl - induced behavioral sensitization and circadian rhythm disorders. The present study suggest that fentanyl (0.05, 0.1 and 0.2 mg/kg) could induce behavioral sensitization and melatonin (30.0 mg/kg) could attenuate the behavioral sensitization and circadian rhythm disorders in mice. Fentanyl treatment reduced the expression of BMAL1 and MAO-A and increased that of TH in relevant brain regions. Furthermore, melatonin treatment could reverse the expression levels of BMAL1, MAO-A, and TH. In conclusion, our study demonstrate for the first time that melatonin has therapeutic potential for fentanyl addiction.


Subject(s)
Chronobiology Disorders , Melatonin , Mice , Animals , Melatonin/pharmacology , Melatonin/therapeutic use , Melatonin/metabolism , ARNTL Transcription Factors , Fentanyl/pharmacology , Fentanyl/therapeutic use , Fentanyl/metabolism , Suprachiasmatic Nucleus/metabolism , Circadian Rhythm/physiology , Chronobiology Disorders/metabolism , Monoamine Oxidase/metabolism , Monoamine Oxidase/pharmacology
4.
J Appl Clin Med Phys ; 25(4): e14259, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38317597

ABSTRACT

BACKGROUND: The treatment planning process from segmentation to producing a deliverable plan is time-consuming and labor-intensive. Existing solutions automate the segmentation and planning processes individually. The feasibility of combining auto-segmentation and auto-planning for volumetric modulated arc therapy (VMAT) for rectal cancers in an end-to-end process is not clear. PURPOSE: To create and clinically evaluate a complete end-to-end process for auto-segmentation and auto-planning of VMAT for rectal cancer requiring only the gross tumor volume contour and a CT scan as inputs. METHODS: Patient scans and data were retrospectively selected from our institutional records for patients treated for malignant neoplasm of the rectum. We trained, validated, and tested deep learning auto-segmentation models using nnU-Net architecture for clinical target volume (CTV), bowel bag, large bowel, small bowel, total bowel, femurs, bladder, bone marrow, and female and male genitalia. For the CTV, we identified 174 patients with clinically drawn CTVs. We used data for 18 patients for all structures other than the CTV. The structures were contoured under the guidance of and reviewed by a gastrointestinal (GI) radiation oncologist. The predicted results for CTV in 35 patients and organs at risk (OAR) in six patients were scored by the GI radiation oncologist using a five-point Likert scale. For auto-planning, a RapidPlan knowledge-based planning solution was modeled for VMAT delivery with a prescription of 25 Gy in five fractions. The model was trained and tested on 20 and 34 patients, respectively. The resulting plans were scored by two GI radiation oncologists using a five-point Likert scale. Finally, the end-to-end pipeline was evaluated on 16 patients, and the resulting plans were scored by two GI radiation oncologists. RESULTS: In 31 of 35 patients, CTV contours were clinically acceptable without necessary modifications. The CTV achieved a Dice similarity coefficient of 0.85 (±0.05) and 95% Hausdorff distance of 15.25 (±5.59) mm. All OAR contours were clinically acceptable without edits, except for large and small bowel which were challenging to differentiate. However, contours for total, large, and small bowel were clinically acceptable. The two physicians accepted 100% and 91% of the auto-plans. For the end-to-end pipeline, the two physicians accepted 88% and 62% of the auto-plans. CONCLUSIONS: This study demonstrated that the VMAT treatment planning technique for rectal cancer can be automated to generate clinically acceptable and safe plans with minimal human interventions.


Subject(s)
Radiotherapy, Intensity-Modulated , Rectal Neoplasms , Humans , Male , Female , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies , Radiotherapy Dosage , Rectal Neoplasms/radiotherapy , Rectum , Organs at Risk , Radiotherapy Planning, Computer-Assisted/methods
5.
Environ Pollut ; 344: 123346, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38215867

ABSTRACT

Tree bark is a useful bioindicator of atmospheric pollution. It is specially suitable for airborne perfluoroalkyl and polyfluoroalkyl substances (PFASs) investigation due to persistence of ionic PFASs. The present work firstly systematically studied tree barks as a bioindicator of airborne PFASs. Comparison with the regular active and passive samplers found barks could produce long-term measurement of airborne PFASs, and could record the historical emission of PFASs with retrospective time frame as long as decades. Factors, e.g. tree type, trunk diameter, and sampling depth, can affect PFAS accumulation in barks, and these factors should be kept consistent during sampling. In a study area spatial distribution of airborne PFASs can be obtained by interpolation of bark results, and the concerned region can be located. Properties of the emission sources can be characterized, and the potential sources can be tracked based on the bark results. Their contributions can be further estimated by the source appointment strategies. In the economically and industrially developed study area of the present study, eight cities of southern Jiangsu Province of China, total ionic PFAS concentration of camphor bark samples collected in 34 sites was 0.44-359 ng/g dw (dry weight), dominated by perfluoroalkyl carboxylic acids (PFCAs). Two types of possible sources were characterized as with long-chained PFCAs and PFOA (perfluorooctanoic acid) as the main components respectively. The sources were appointed as fluoropolymer manufacturing and textile industries, the important PFAS application fields, and their relative contribution was estimated as 32.5% and 67.5% respectively. The present study can provide useful advice to the method framework of using barks for long-term occurrence investigation, concerned region location, and emission source appointment of airborne PFASs in a study area. Based on the bark results, effective strategies can be further made for PFAS pollution elimination and risk control.


Subject(s)
Alkanesulfonic Acids , Fluorocarbons , Water Pollutants, Chemical , Plant Bark/chemistry , Environmental Biomarkers , Retrospective Studies , Environmental Monitoring , Fluorocarbons/analysis , China , Carboxylic Acids , Water Pollutants, Chemical/analysis , Alkanesulfonic Acids/analysis
6.
Asian J Surg ; 47(2): 993-994, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37914650

ABSTRACT

TECHNIQUE: (1) A four-pointed star-shaped incision was made to separate the skin around the stoma intestine. (2) The stoma intestine was resected, and side-to-side or end-to-side anastomosis was performed to restore the continuity of the intestine. (3) The peritoneum and rectus sheath should be closed using continuous full-thickness sutures. (4) The subcutaneous fat layer and dermis layer should be sutured using purse-string sutures. Two holes should be made in the center of the sutured area. (5) The cross should be sutured intermittently on all four sides using 1-2 stitches. (6) A rubber strip should be placed in the center of the small hole. RESULTS: The presence of a small hole in the center of the incision and the use of a rubber strip for drainage facilitate early fluid drainage. The design of a cross-stitched skin incision helps reduce local tension. CONCLUSION: The modified cross-suture technique may reduce postoperative incision infections and associated pain, which is a suitable incision treatment method for loop stoma reversal.


Subject(s)
Abdominal Wall , Surgical Stomas , Humans , Rubber , Suture Techniques , Surgical Wound Infection , Sutures
7.
J Vis Exp ; (200)2023 10 06.
Article in English | MEDLINE | ID: mdl-37870317

ABSTRACT

Access to radiotherapy worldwide is limited. The Radiation Planning Assistant (RPA) is a fully automated, web-based tool that is being developed to offer fully automated radiotherapy treatment planning tools to clinics with limited resources. The goal is to help clinical teams scale their efforts, thus reaching more patients with cancer. The user connects to the RPA via a webpage, completes a Service Request (prescription and information about the radiotherapy targets), and uploads the patient's CT image set. The RPA offers two approaches to automated planning. In one-step planning, the system uses the Service Request and CT scan to automatically generate the necessary contours and treatment plan. In two-step planning, the user reviews and edits the automatically generated contours before the RPA continues to generate a volume-modulated arc therapy plan. The final plan is downloaded from the RPA website and imported into the user's local treatment planning system, where the dose is recalculated for the locally commissioned linac; if necessary, the plan is edited prior to approval for clinical use.


Subject(s)
Neoplasms , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Radiotherapy Dosage , Internet
8.
J Appl Clin Med Phys ; 24(12): e14131, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37670488

ABSTRACT

PURPOSE: Two-dimensional radiotherapy is often used to treat cervical cancer in low- and middle-income countries, but treatment planning can be challenging and time-consuming. Neural networks offer the potential to greatly decrease planning time through automation, but the impact of the wide range of hyperparameters to be set during training on model accuracy has not been exhaustively investigated. In the current study, we evaluated the effect of several convolutional neural network architectures and hyperparameters on 2D radiotherapy treatment field delineation. METHODS: Six commonly used deep learning architectures were trained to delineate four-field box apertures on digitally reconstructed radiographs for cervical cancer radiotherapy. A comprehensive search of optimal hyperparameters for all models was conducted by varying the initial learning rate, image normalization methods, and (when appropriate) convolutional kernel size, the number of learnable parameters via network depth and the number of feature maps per convolution, and nonlinear activation functions. This yielded over 1700 unique models, which were all trained until performance converged and then tested on a separate dataset. RESULTS: Of all hyperparameters, the choice of initial learning rate was most consistently significant for improved performance on the test set, with all top-performing models using learning rates of 0.0001. The optimal image normalization was not consistent across architectures. High overlap (mean Dice similarity coefficient = 0.98) and surface distance agreement (mean surface distance < 2 mm) were achieved between the treatment field apertures for all architectures using the identified best hyperparameters. Overlap Dice similarity coefficient (DSC) and distance metrics (mean surface distance and Hausdorff distance) indicated that DeepLabv3+ and D-LinkNet architectures were least sensitive to initial hyperparameter selection. CONCLUSION: DeepLabv3+ and D-LinkNet are most robust to initial hyperparameter selection. Learning rate, nonlinear activation function, and kernel size are also important hyperparameters for improving performance.


Subject(s)
Deep Learning , Uterine Cervical Neoplasms , Female , Humans , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy , Neural Networks, Computer , Algorithms , Tomography, X-Ray Computed , Image Processing, Computer-Assisted/methods
9.
Int J Antimicrob Agents ; 62(5): 106961, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37666436

ABSTRACT

OBJECTIVES: The emergence of pathogens that are resistant to both tigecycline and carbapenem poses a threat to public health globally. Continuous emergence of novel tet(X) variants accelerates the tigecycline resistance crisis. This study aimed to characterise the novel tigecycline resistance gene tet(X22) and its coexistence with carbapenem resistance gene blaNDM-1 in Pseudomonas caeni. METHODS: This P. caeni isolate co-harbouring tet(X22) and blaNDM-1 was systematically investigated using antimicrobial susceptibility testing, conjugation assays, genome sequencing, bioinformatic analyses, cloning of tet(X22) and functional analysis, and protein structure prediction. RESULTS: The carbapenem-resistant and tigecycline-resistant P. caeni isolate CE14 was obtained from chicken faeces in 2022. CE14 carried multiple antibiotic resistance genes, including the novel tet(X22) and blaNDM-1. Tet(X22) exhibited 64.72-90.48% amino acid identity with other variants [Tet(X) to Tet(X21)]. Cloning of the gene tet(X22) and protein structure prediction revealed that Tet(X22) confers resistance to tetracyclines, including tigecycline. tet(X22) and blaNDM-1 were located in two multidrug-resistant regions of the chromosome. CONCLUSIONS: The occurrence of the novel ISCR2-flanked tet(X22) in P. caeni suggests that the tet(X) variant has adapted to new hosts and may widely spread to further expand the host range. The future global spread of such pathogens co-harbouring tet(X) and blaNDM variants needs to be continuously monitored according to the One Health approach.


Subject(s)
Anti-Bacterial Agents , Carbapenems , Tigecycline/pharmacology , Anti-Bacterial Agents/pharmacology , Carbapenems/pharmacology , Microbial Sensitivity Tests , Plasmids
10.
Ecotoxicol Environ Saf ; 263: 115245, 2023 Sep 15.
Article in English | MEDLINE | ID: mdl-37451097

ABSTRACT

Polybrominated diphenyl ether (PBDE) contamination is common in aquatic environments and can severely damage aquatic organisms. However, there is a lack of information on the response and self-adaptation mechanisms of these organisms. Chlorella pyrenoidosa was treated with 2,2',4,4'-tetrabromodiphenyl ether (BDE47), causing significant growth inhibition, pigment reduction, oxidative stress, and chloroplast atrophy. Photosynthetic damage contributed to inhibition, as indicated by Fv/Fm, Chl a fluorescence induction, photosynthetic oxygen evolution activity, and photosystem subunit stoichiometry. Here, Chl a fluorescence induction and quinone electron acceptor (QA-) reoxidation kinetics showed that the PSII donor and acceptor sides were insensitive to BDE47. Quantitative analyses of D1 and PsaD proteins illustrated that PSII and PSI complexes were the main primary targets of photosynthesis inhibition by BDE47. Significant modulation of PSII complex might have been caused by the potential binding of BDE47 on D1 protein, and molecular docking was performed to investigate this. Increased activation of antioxidant defense systems and photosystem repair as a function of exposure time indicated a positive resistance to BDE47. After a 5-day exposure, 23 % of BDE47 was metabolized. Our findings suggest that C. pyrenoidosa has potential as a bioremediator for wastewater-borne PBDEs and can improve our understanding of ecological risks to microalgae.


Subject(s)
Chlorella , Halogenated Diphenyl Ethers , Halogenated Diphenyl Ethers/toxicity , Halogenated Diphenyl Ethers/metabolism , Chlorella/metabolism , Molecular Docking Simulation , Photosynthesis , Electron Transport , Photosystem II Protein Complex/metabolism
11.
JCO Glob Oncol ; 9: e2200431, 2023 07.
Article in English | MEDLINE | ID: mdl-37471671

ABSTRACT

PURPOSE: Automation, including the use of artificial intelligence, has been identified as a possible opportunity to help reduce the gap in access and quality for radiotherapy and other aspects of cancer care. The Radiation Planning Assistant (RPA) project was conceived in 2015 (and funded in 2016) to use automated contouring and treatment planning algorithms to support the efforts of oncologists in low- and middle-income countries, allowing them to scale their efforts and treat more patients safely and efficiently (to increase access). DESIGN: In this review, we discuss the development of the RPA, with a particular focus on clinical acceptability and safety/risk across jurisdictions as these are important indicators for the successful future deployment of the RPA to increase radiotherapy availability and ameliorate global disparities in access to radiation oncology. RESULTS: RPA tools will be offered through a webpage, where users can upload computed tomography data sets and download automatically generated contours and treatment plans. All interfaces have been designed to maximize ease of use and minimize risk. The current version of the RPA includes automated contouring and planning for head and neck cancer, cervical cancer, breast cancer, and metastases to the brain. CONCLUSION: The RPA has been designed to bring high-quality treatment planning to more patients across the world, and it may encourage greater investment in treatment devices and other aspects of cancer treatment.


Subject(s)
Breast Neoplasms , Radiation Oncology , Humans , Female , Radiotherapy Planning, Computer-Assisted/methods , Artificial Intelligence , Breast Neoplasms/pathology , Automation
12.
Med Phys ; 50(7): 4466-4479, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37086040

ABSTRACT

PURPOSE: A novel compensator-based system has been proposed which delivers intensity-modulated radiation therapy (IMRT) with cobalt-60 beams. This could improve access to advanced radiotherapy in low- and middle-income countries. For this system to be clinically viable and to be adapted into the Radiation Planning Assistant (RPA), being developed to offer automated planning services in low- and middle-income countries, it is necessary to commission and validate it in a commercial treatment planning system (TPS). METHODS: The novel treatment device considered here employs a cobalt-60 source and nine compensators. Each compensator is produced by 3-D printing a thin plastic mold which is then filled on-demand within the machine with reusable 2-mm-diameter spherical tungsten balls. This system was commissioned in the Eclipse TPS and validation tests were conducted with Monte Carlo using Geant4 Application for Tomographic Emission for percentage depth dose, in-plane profiles, penumbra, and IMRT dose validation. And the American Association of Physicists in Medicine Task Group 119 benchmarking testing was performed. Additionally, compensator-based cobalt-60 IMRT plans were created for 46 head-and-neck cancer cases and compared to the linac-based volumetric modulated arc therapy (VMAT) plans used clinically, then dosimetric parameters were evaluated. Beam-on time for each field was calculated. In addition, the measurement was also performed in a limited environment and compared with the Monte Carlo simulations. RESULTS: The differences in percent depth doses and in-plane profiles between the Eclipse and Monte Carlo simulations were 0.65% ± 0.41% and 1.02% ± 0.99%, respectively, and the 80%-20% penumbra agreed within 0.46 ± 0.27 mm. For the Task Group 119 validation plans, all treatment planning goals were met and gamma passing rates were >95% (3%/3 mm criteria). In 46 clinical head-and-neck cases, the cobalt-60 compensator-based IMRT plans had planning target volume (PTV) coverages similar to linac-based VMAT plans: all dosimetric values for PTV were within 1.5%. The organs at risk dose parameters were somewhat higher in cobalt-60 compensator-based IMRT plans versus linac-based VMAT plans. The mean dose differences for the spinal cord, brain, and brainstem were 4.43 ± 1.92, 3.39 ± 4.67, and 2.40 ± 3.71 Gy, while those for the rest of the organs were <1 Gy. The average beam-on time per field was 0.42 ± 0.10 min for the 6 MV multi-leaf-collimator plans while those for the cobalt-60 compensator plans were 0.17 ± 0.01 and 0.31 ± 0.01 min at the dose rates of 350 and 175 cGy/min. There was a good agreement between in-plane profiles from measurements and Monte Carlo simulations, which differences are 1.34 ± 1.90% and 0.13 ± 2.16% for two different fields. CONCLUSIONS: A novel compensator-based IMRT system using cobalt-60 beams was commissioned and validated in a commercial TPS. Plan quality with this system was comparable to that of linac-based plans in all test cases with shorter estimated beam-on times. This system enables reliable, high-quality plans with reduced cost and complexity and may have benefits for underserved regions of the world. This system is being integrated into the RPA, a web-based platform for auto-contouring and auto-planning.


Subject(s)
Radiotherapy, Intensity-Modulated , Radiotherapy, Intensity-Modulated/methods , Cobalt Radioisotopes/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage
13.
Article in English | MEDLINE | ID: mdl-36982014

ABSTRACT

A systematic investigation was conducted on the emission of hexachlorobutadiene (HCBD) from two tetrachloroethylene factories that used the acetylene method (F1) and the tetrachloride transformation method (F2). The levels of HCBD in the air for F1 were found to be in the range of 1.46-1170 µg/m3, whereas F2 had levels in the range of 1.96-5530 µg/m3. Similarly, the levels of HCBD in the soil for F1 were found to be in the range from 42.2 to 140 µg/kg, whereas F2 had levels in the range from 4.13 to 2180 µg/kg. Samples obtained from the air, soil, and sludge in the reaction area of the tetrachloroethylene factories in China showed high levels of HCBD. The F1 method unintentionally produced more HCBD than the F2 method during tetrachloroethylene production, leading to greater harm. The results of the risk assessment suggested the presence of harmful health effects on workers in the workplace. The investigation findings highlight the need for improved management systems to ensure the safe production of tetrachloroethylene.


Subject(s)
Soil Pollutants , Tetrachloroethylene , Humans , Butadienes/toxicity , Soil , Soil Pollutants/analysis
14.
Natl Sci Rev ; 10(1): nwac207, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36654916

ABSTRACT

Methane (CH4) is a critical but overlooked component in the study of the deep carbon cycle. Abiotic CH4 produced by serpentinization of ultramafic rocks has received extensive attention, but its formation and flux in mafic rocks during subduction remain poorly understood. Here, we report massive CH4-rich fluid inclusions in well-zoned garnet from eclogites in Western Tianshan, China. Petrological characteristics and carbon-hydrogen isotopic compositions confirm the abiotic origin of this CH4. Reconstructed P-T-fO2-fluid trajectories and Deep Earth Water modeling imply that massive abiotic CH4 was generated during cold subduction at depths of 50-120 km, whereas CO2 was produced during exhumation. The massive production of abiotic CH4 in eclogites may result from multiple mechanisms during prograde high pressure-ultrahigh pressure metamorphism. Our flux calculation proposes that abiotic CH4 that has been formed in HP-UHP eclogites in cold subduction zones may represent one of the largest, yet overlooked, sources of abiotic CH4 on Earth.

15.
J Appl Clin Med Phys ; 24(3): e13839, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36412092

ABSTRACT

PURPOSE: To develop and evaluate an automated whole-brain radiotherapy (WBRT) treatment planning pipeline with a deep learning-based auto-contouring and customizable landmark-based field aperture design. METHODS: The pipeline consisted of the following steps: (1) Auto-contour normal structures on computed tomography scans and digitally reconstructed radiographs using deep learning techniques, (2) locate the landmark structures using the beam's-eye-view, (3) generate field apertures based on eight different landmark rules addressing different clinical purposes and physician preferences. Two parallel approaches for generating field apertures were developed for quality control. The performance of the generated field shapes and dose distributions were compared with the original clinical plans. The clinical acceptability of the plans was assessed by five radiation oncologists from four hospitals. RESULTS: The performance of the generated field apertures was evaluated by the Hausdorff distance (HD) and mean surface distance (MSD) from 182 patients' field apertures used in the clinic. The average HD and MSD for the generated field apertures were 16 ± 7 and 7 ± 3 mm for the first approach, respectively, and 17 ± 7 and 7 ± 3 mm, respectively, for the second approach. The differences regarding HD and MSD between the first and the second approaches were 1 ± 2 and 1 ± 3 mm, respectively. A clinical review of the field aperture design, conducted using 30 patients, achieved a 100% acceptance rate for both the first and second approaches, and the plan review achieved a 100% acceptance rate for the first approach and a 93% acceptance rate for the second approach. The average acceptance rate for meeting lens dosimetric recommendations was 80% (left lens) and 77% (right lens) for the first approach, and 70% (both left and right lenses) for the second approach, compared with 50% (left lens) and 53% (right lens) for the clinical plans. CONCLUSION: This study provided an automated pipeline with two field aperture generation approaches to automatically generate WBRT treatment plans. Both quantitative and qualitative evaluations demonstrated that our novel pipeline was comparable with the original clinical plans.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Radiometry , Tomography, X-Ray Computed , Brain , Radiotherapy, Intensity-Modulated/methods
16.
Ir J Med Sci ; 192(3): 1033-1040, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35819743

ABSTRACT

BACKGROUND: Apatinib, a small molecule targeting VEGFR2, is commonly used for advanced gastric cancer treatment. This prospective cohort study further investigated the efficacy and safety of neoadjuvant apatinib plus chemotherapy in locally advanced gastric carcinoma patients. METHODS: Ninety-six locally advanced gastric carcinoma patients were divided into the apatinib plus chemotherapy group (N = 45) and chemotherapy group (N = 51) according to their chosen treatment. Apatinib was administered (375 mg/day), and S-1 plus oxaliplatin (SOX) or oxaliplatin plus capecitabine (CapOx) was given as chemotherapy, for 3 cycles with 3 weeks a cycle before surgery. RESULTS: The objective response rate (62.2% vs. 37.3%, P = 0.015) and pathological response grade (P = 0.011) were better; meanwhile, the tumor-resection rate (95.6% vs. 84.3%, P = 0.143) and pathological complete response rate (23.3% vs. 9.3%, P = 0.080) exhibited increasing trends (without statistical significance) in the apatinib plus chemotherapy group compared with the chemotherapy group. Additionally, the apatinib plus chemotherapy group achieved prolonged disease-free survival (DFS) (P = 0.019) and overall survival (OS) (P = 0.047) compared with the chemotherapy group. After adjusted by multivariate Cox's regression analysis, neoadjuvant apatinib plus chemotherapy was still superior to chemotherapy regarding DFS (hazard ratio (HR): 0.277, P = 0.014) and OS (HR: 0.316, P = 0.038). Notably, the incidences of adverse events between the two groups were not different (P > 0.050). Moreover, the most common adverse events of neoadjuvant apatinib plus chemotherapy were leukopenia (42.2%), fatigue (37.8%), hypertension (37.8%), and anemia (31.1%). CONCLUSION: Neoadjuvant apatinib plus chemotherapy realizes better clinical response, pathological response, survival profile, and non-inferior safety profile compared to chemotherapy in locally advanced gastric carcinoma.


Subject(s)
Carcinoma , Stomach Neoplasms , Humans , Stomach Neoplasms/pathology , Neoadjuvant Therapy , Prospective Studies , Cohort Studies , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Carcinoma/drug therapy
17.
Antibiotics (Basel) ; 11(10)2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36290080

ABSTRACT

Bacteria with carbapenem or tigecycline resistance have been spreading widely among humans, animals and the environment globally, being great threats to public health. However, bacteria co-carrying drug resistance genes of carbapenem and tigecycline in Shewanella and Acinetobacter species remain to be investigated. Here, we detected nine blaNDM-1-carrying Shewanella spp. isolates as well as three A. portensis isolates co-harboring tet(X3) and blaNDM-1 from seventy-two samples collected from a dairy farm in China. To explore their genomic characteristic and transmission mechanism, we utilized various methods, including PCR, antimicrobial susceptibility testing, conjugation experiment, whole-genome sequencing, circular intermediate identification and bioinformatics analysis. Clonal dissemination was found among three A. portensis, of which tet(X3) and blaNDM-1 were located on a novel non-conjugative plasmid pJNE5-X3_NDM-1 (333,311 bp), and the circular intermediate ΔISCR2-tet(X3)-blaNDM-1 was identified. Moreover, there was another copy of tet(X3) on the chromosome of A. portensis. It was verified that blaNDM-1 could be transferred to Escherichia coli C600 from Shewanella spp. by conjugation, and self-transmissible IncA/C2 plasmids mediated the transmission of blaNDM-1 in Shewanella spp. strains. Stringent surveillance was warranted to curb the transmission of such vital resistance genes.

18.
J Appl Clin Med Phys ; 23(9): e13694, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35775105

ABSTRACT

PURPOSE: To develop a checklist that improves the rate of error detection during the plan review of automatically generated radiotherapy plans. METHODS: A custom checklist was developed using guidance from American Association of Physicists in Medicine task groups 275 and 315 and the results of a failure modes and effects analysis of the Radiation Planning Assistant (RPA), an automated contouring and treatment planning tool. The preliminary checklist contained 90 review items for each automatically generated plan. In the first study, eight physicists were recruited from our institution who were familiar with the RPA. Each physicist reviewed 10 artificial intelligence-generated resident treatment plans from the RPA for safety and plan quality, five of which contained errors. Physicists performed plan checks, recorded errors, and rated each plan's clinical acceptability. Following a 2-week break, physicists reviewed 10 additional plans with a similar distribution of errors using our customized checklist. Participants then provided feedback on the usability of the checklist and it was modified accordingly. In a second study, this process was repeated with 14 senior medical physics residents who were randomly assigned to checklist or no checklist for their reviews. Each reviewed 10 plans, five of which contained errors, and completed the corresponding survey. RESULTS: In the first study, the checklist significantly improved the rate of error detection from 3.4 ± 1.1 to 4.4 ± 0.74 errors per participant without and with the checklist, respectively (p = 0.02). Error detection increased by 20% when the custom checklist was utilized. In the second study, 2.9 ± 0.84 and 3.5 ± 0.84 errors per participant were detected without and with the revised checklist, respectively (p = 0.08). Despite the lack of statistical significance for this cohort, error detection increased by 18% when the checklist was utilized. CONCLUSION: Our results indicate that the use of a customized checklist when reviewing automated treatment plans will result in improved patient safety.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Artificial Intelligence , Checklist , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
19.
J Appl Clin Med Phys ; 23(8): e13704, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35791594

ABSTRACT

PURPOSE: Knowledge-based planning (KBP) has been shown to be an effective tool in quality control for intensity-modulated radiation therapy treatment planning and generating high-quality plans. Previous studies have evaluated its ability to create consistent plans across institutions and between planners within the same institution as well as its use as teaching tool for inexperienced planners. This study evaluates whether planning quality is consistent when using a KBP model to plan across different treatment machines. MATERIALS AND METHODS: This study used a RapidPlan model (Varian Medical Systems) provided by the vendor, to which we added additional planning objectives, maximum dose limits, and planning structures, such that a clinically acceptable plan is achieved in a single optimization. This model was used to generate and optimize volumetric-modulated arc therapy plans for a cohort of 50 patients treated for head-neck cancer. Plans were generated using the following treatment machines: Varian 2100, Elekta Versa HD, and Varian Halcyon. A noninferiority testing methodology was used to evaluate the hypothesis that normal and target metrics in our autoplans were no worse than a set of clinically-acceptable baseline plans by a margin of 1.8 Gy or 3% dose-volume. The quality of these plans were also compared through the use of common clinical dose-volume histogram criteria. RESULTS: The Versa HD met our noninferiority criteria for 23 of 34 normal and target metrics; while the Halcyon and Varian 2100 machines met our criteria for 24 of 34 and 26 of 34 metrics, respectively. The experimental plans tended to have less volume coverage for prescription dose planning target volume and larger hotspot volumes. However, comparable plans were generated across different treatment machines. CONCLUSIONS: These results support the use of a head-neck RapidPlan models in centralized planning workflows that support clinics with different linac models/vendors, although some fine-tuning for targets may be necessary.


Subject(s)
Head and Neck Neoplasms , Radiotherapy, Intensity-Modulated , Head and Neck Neoplasms/radiotherapy , Humans , Knowledge Bases , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
20.
J Appl Clin Med Phys ; 23(9): e13712, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35808871

ABSTRACT

PURPOSE: To develop an automated workflow for rectal cancer three-dimensional conformal radiotherapy (3DCRT) treatment planning that combines deep learning (DL) aperture predictions and forward-planning algorithms. METHODS: We designed an algorithm to automate the clinical workflow for 3DCRT planning with field aperture creations and field-in-field (FIF) planning. DL models (DeepLabV3+ architecture) were trained, validated, and tested on 555 patients to automatically generate aperture shapes for primary (posterior-anterior [PA] and opposed laterals) and boost fields. Network inputs were digitally reconstructed radiographs, gross tumor volume (GTV), and nodal GTV. A physician scored each aperture for 20 patients on a 5-point scale (>3 is acceptable). A planning algorithm was then developed to create a homogeneous dose using a combination of wedges and subfields. The algorithm iteratively identifies a hotspot volume, creates a subfield, calculates dose, and optimizes beam weight all without user intervention. The algorithm was tested on 20 patients using clinical apertures with varying wedge angles and definitions of hotspots, and the resulting plans were scored by a physician. The end-to-end workflow was tested and scored by a physician on another 39 patients. RESULTS: The predicted apertures had Dice scores of 0.95, 0.94, and 0.90 for PA, laterals, and boost fields, respectively. Overall, 100%, 95%, and 87.5% of the PA, laterals, and boost apertures were scored as clinically acceptable, respectively. At least one auto-plan was clinically acceptable for all patients. Wedged and non-wedged plans were clinically acceptable for 85% and 50% of patients, respectively. The hotspot dose percentage was reduced from 121% (σ = 14%) to 109% (σ = 5%) of prescription dose for all plans. The integrated end-to-end workflow of automatically generated apertures and optimized FIF planning gave clinically acceptable plans for 38/39 (97%) of patients. CONCLUSION: We have successfully automated the clinical workflow for generating radiotherapy plans for rectal cancer for our institution.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Rectal Neoplasms , Automation , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Rectal Neoplasms/radiotherapy
SELECTION OF CITATIONS
SEARCH DETAIL
...