Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Infect Dis Health ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38702235

ABSTRACT

BACKGROUND: Filtering Facepiece Respirators (FFRs) are an important and readily scalable infection control measure; however their effectiveness is ultimately determined by compliance. We aimed to examine staff compliance and satisfaction with wearing the N95/P2 FFRs assigned to them via the standardised fit testing protocol implemented in a single large healthcare network in Victoria, Australia. METHODS: In this cross-sectional survey, employees from five hospital campuses who participated in the health networks N95/P2 FFR fit testing process were invited in person to participate in the study. Data were analysed descriptively, after which chi-squared analysis was performed to determine differences between respirator types, gender, and age groups. RESULTS: Amongst the 258 staff members surveyed, 28% had either never or only sometimes worn an FFR to which they had been successfully fit tested, and 11% had experienced facial changes that potentially rendered their most recent fit test invalid. More than half (53%) of those surveyed had experienced side effects, the most common being skin irritation and pressure sores. A majority (87%) of staff felt that wearing an FFR had some impact on their ability to perform their duties. Pooled mean self-reported satisfaction ratings were highest for three-panel flat-fold and duckbill models. CONCLUSION: 28% of HCWs surveyed described not wearing N-95/P2 FFRs for which they had successfully been fit tested. Reasons for non-compliance remain unclear, but rates of side effects and interference with duties were high. Further research is required to determine and address potential causative factors and ascertain ongoing optimal organisation-level fit test strategies.

2.
Article in English | MEDLINE | ID: mdl-38156215

ABSTRACT

Objective: To provide fit rates for specific P2/N95 respirators and compare these results by age, sex, clean-shaven status, and fit tester experience. Design: Exploratory audit involving secondary analysis of existing quantitative fit testing data. Setting: In response to the COVID-19 pandemic, healthcare services across Australia implemented respiratory protection protocols. This study details healthcare workers' (HCWs) fit testing results from a large Victorian public health service. Participants: Fit-tested employees of a large tertiary public health network. Methods: Fit rates for ten individual P2/N95 respirators were calculated, and the effect of age, sex, clean-shaven status, and fit tester experience was examined via logistic regression. Results: 4593 employees were included, with 97.98% successfully fitting at least one respirator. Males were found to have significantly increased odds of achieving fit success compared to females (OR 11.61 95%CI 1.60-84.10). Fit rates dropped by 4% with each 1-year age increase (OR 0.96 95%CI 0.94-0.98). Clean-shaven individuals were also more likely to achieve a fit compared to non-clean-shaved individuals (OR 79.23 95%CI 10.21-614.62). More experienced fit testers also yielded significantly higher fit rates (OR 3.95, 95%CI 2.34-6.67). Conclusions: 98% of staff achieved a successful fitting of at least one respirator, with three-panel flat fold models (Industree Trident, 3M Aura 9320A+, and 3M Aura 1870+) performing the most consistently. An individual's ability to achieve a successful fit was associated with; male sex, younger age, clean-shaven status, and fit tester experience.

SELECTION OF CITATIONS
SEARCH DETAIL
...