Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Pak J Med Sci ; 39(1): 248-252, 2023.
Article in English | MEDLINE | ID: mdl-36694744

ABSTRACT

Objective: To evaluate the clinical efficacy and immune function of Daratumumab combined with chemotherapy in patients with relapsed/refractory multiple myeloma (RRMM). Methods: Eighty patients with RRMM treated in Xingtai People's Hospital from January, 2020 to December, 2021 were randomly divided into two groups. Patients in the study group were treated with Daratumumab combined with PAD regimen, while patients in the control group were provided with PAD regimen alone. Further comparison was performed on the therapeutic effects, adverse drug reactions, the levels of T lymphocyte subsets CD3+, CD4+, CD8+ and CD4+/CD8+, the positive expression rate of CD38 and the expression level of Notch-1 on the membrane of plasma cells between the two groups. Results: The overall response rate in the study group (67.50%) was significantly better than that in the control group (45.00%). There was no significant difference in the incidence of adverse reactions between the two groups. After treatment, the reviewed levels of CD3+, CD4+ and CD4+/CD8+ were obviously higher in the study group than those in the control group, while the positive expression rate of CD38 and the expression level of Notch one on the membrane of plasma cells were both lower than those in the control group (p<0.05). Conclusion: Daratumumab combined with a PAD regimen is a safe and effective approach that has a definite curative effect on patients with RRMM, which can improve immune function significantly and result in no significant increase in adverse reactions.

2.
Anal Chem ; 90(5): 3149-3155, 2018 03 06.
Article in English | MEDLINE | ID: mdl-29397683

ABSTRACT

A simple, noncovalent modification strategy was proposed to synthesize poly-l-lysine-black phosphorus (pLL-BP) hybrid. BP nanoflakes were prepared with a water-phase exfoliation method. pLL can adhere to the surface of BP via hydrophobic interaction between butyl chains of pLL and the BP surface as well as the electrostatic interaction between the protonated amino groups on pLL and the negative charge on deprotonated PxOy groups remaining on BP. The as-synthesized pLL-BP hybrid turns out to be an ideal matrix for hemoglobin immobilization and direct electron transfer. Good conductivity and biocompatibility of BP maintain the native structure and the bioactivity of hemoglobin (Hb), facilitating the direct electron transfer between the electroactive center of Hb and electrode. The rate constant ( kET) for direct electron transfer of Hb@pLL-BP is calculated to be 11.24 s-1. The constructed Hb-pLL-BP based enzymatic electrochemical biosensor displays excellent catalytic activity toward the reduction of oxygen and hydrogen peroxide. The electrochemical response toward H2O2 exhibits a linear dependence on hydrogen peroxide concentration ranging between 10 µM and 700 µM. The results demonstrate that the pLL-BP hybrid can act as a biocompatible building block for the construction of novel biofuel cells, bioelectronics, and biosensors.


Subject(s)
Nanostructures/chemistry , Phosphorus/chemistry , Polylysine/chemistry , Animals , Biosensing Techniques/methods , Cattle , Electrochemical Techniques/methods , Hemoglobins/chemistry , Hydrogen Peroxide/analysis , Hydrogen Peroxide/chemistry , Hydrophobic and Hydrophilic Interactions , Immobilized Proteins/chemistry , Polylysine/chemical synthesis
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(4): 967-71, 2016 Apr.
Article in Chinese | MEDLINE | ID: mdl-30048091

ABSTRACT

In the process of practical production, it is important to accurately analyze the proportion of mixed samples with high speed, which plays a great role for quality control and formulation design in food and agricultural processing. Traditional solution is to build statistical model with a large number of representative samples, which is both labor-intensive and time-consuming. In this paper, the proportion of alcohol and acids mixed samples, and their dilute solution mixed samples(used carbon tetrachloride (CCl4) which has no near-infrared absorption characteristics as the solvent medium),as well as sheet tobacco leaf mixed samples are respectively analyzed by using near infrared spectroscopy, SG smooth and non-negative coefficients regression, which verifies the feasibility of analyzing the proportion of the mixed samples. The results show that, the analytic proportion of transmission spectra of alcohol and acids according to non-negative coefficients regression is closer to actual molar proportion with result error less than 4%. The result of the dilute solution is much better with error less than 4%. The analytic proportion of diffuse reflectance spectra of sheet tobacco leaf according to non-negative coefficients regression is highly accurate with error less than 10%. In the meantime, it has a highly consistency between actual spectra and analytic spectra of mixed samples; and the result of F-test and T-test shows that there is no significant difference between them and the confidence level is 0.01. It has the reliability of analytical proportion in theory. With the spectral data of several pure samples, the proportion of mixed samples can be thus analyzed, which has a good application prospect for quality control and formulation design in food and agricultural processing.

SELECTION OF CITATIONS
SEARCH DETAIL
...