Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Chin J Dent Res ; 24(4): 231-234, 2021 12 23.
Article in English | MEDLINE | ID: mdl-35029094

ABSTRACT

The irradiance of powered polymerisation activators for chairside use affects composite resin adhesive curing during the restorative process, whereas radiant accumulated temperature rise relates to clinical safety. Irradiance reduction and high radiant accumulated temperature will compromise the treatment results as there is a lack of curing output efficacy and safety awareness for powered polymerisation activators. Insufficient attention has been paid to the activator's quality control, irradiance attenuation and radiant accumulated temperature excessive temperature rise during its lifetime. The present manuscript has been drafted by the Society of Dental Equipment, Chinese Stomatological Association to fill the quality control gap and guide the quality control process, following tested steps, using a metered radiometer and a thermometer to record the irradiance and radiant accumulated temperature separately. The testing result may indicate the equipment's situation in service and provide information about the irradiance values and performance of the powered polymerisation activator for its usage and maintenance.


Subject(s)
Composite Resins , Curing Lights, Dental , Materials Testing , Polymerization , Quality Control
2.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 44(5): 262-5, 2009 May.
Article in Chinese | MEDLINE | ID: mdl-19575980

ABSTRACT

OBJECTIVE: To evaluate the shaping ability of hand-used ProTaper on curved canals using Endodontic Cube. METHODS: Fifty-four curved root canals in vitro were selected and divided into three groups according to the curved degree (alpha), group A: 0 degrees < or = alpha < 25 degrees , group B: 25 degrees < or = alpha < 40 degrees , group C: 40 degrees < or = alpha < 55 degrees . Endodontic Cube was assembled, and each sample was sectioned perpendicular to the axis of the tooth into four sections with Isomer-Buhler in low speed. Then the root canals were prepared with hand-used ProTaper. Before and after shaping, photograph of all the sections were taken under a stereomicroscope. Statistical analyses were performed. RESULTS: The dentin cutting quantity of the whole canal prepared with ProTaper in group B and C was larger than that of group A. The deviation distance of the whole canal prepared by ProTaper in group C was significantly larger than that in group A, and the deviation distance in middle portion larger than that in group B. The maintaining ability in the middle portion of group C by ProTaper was worse than that of group A and B. CONCLUSIONS: The curvature of root canal may increase the cutting quantity of the -dentin and reduce the ability of remaining original canal shape prepared by ProTaper.


Subject(s)
Root Canal Therapy/instrumentation , Root Canal Therapy/methods , Dental Instruments
SELECTION OF CITATIONS
SEARCH DETAIL
...