Molecules ; 26(13)2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34279368

ABSTRACT

The purpose of this study was to identify new metal-based anticancer drugs; to this end, we synthesized two new copper(II) complexes, namely [Cu(ncba)4(phen)] (1) and [Cu(ncba)4(bpy)] (2), comprised 4-chloro-3-nitrobenzoic acid as the main ligand. The single-crystal XRD approach was employed to determine the copper(II) complex structures. Binding between these complexes and calf thymus DNA (CT-DNA) and human serum albumin (HSA) was explored by electronic absorption, fluorescence spectroscopy, and viscometry. Both complexes intercalatively bound CT-DNA and statically and spontaneously quenched DNA/HSA fluorescence. A CCK-8 assay revealed that complex 1 and complex 2 had substantial antiproliferative influences against human cancer cell lines. Moreover, complex 1 had greater antitumor efficacy than the positive control cisplatin. Flow cytometry assessment of the cell cycle demonstrated that these complexes arrested the HepG2 cell cycle and caused the accumulation of G0/G1-phase cells. The mechanism of cell death was elucidated by flow cytometry-based apoptosis assays. Western blotting revealed that both copper(II) complexes induced apoptosis by regulating the expression of the Bcl-2(Bcl-2, B cell lymphoma 2) protein family.


Subject(s)
Antineoplastic Agents/chemical synthesis , Chlorobenzoates/chemistry , Coordination Complexes/chemical synthesis , Copper/chemistry , Serum Albumin, Human/chemistry , Antineoplastic Agents/pharmacology , Apoptosis/drug effects , Cell Proliferation/drug effects , Coordination Complexes/pharmacology , DNA/chemistry , Hep G2 Cells , Humans
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(8): 2660-3, 2016 Aug.
Article in Chinese | MEDLINE | ID: mdl-30074725

ABSTRACT

In order to quickly and accurately obtain the transient temperature field information of the barrel when the gun is firing, the transient temperature measurement system was designed with apodized-chirped fiber Bragg grating (FBG) probe. In the system, chirped fiber grating was used to modulate the bandwidth of echo light. The bandwidth of echo light had been greatly improved. So the number of apodized-chirped FBGs in one fiber could be greatly increased, and the energy of echo light was increased too. The performances of five common apodization functions were analyzed, and the super-Gaussian function was used to process the echo signals in the system. This function effectively suppressed sidelobe increases and spectral dispersion caused by chirp modulation, which indicated that it could meet the design requirements of the transient temperature measurement. 50 apodized-chirped FBGs, which evenly wound on the barrel, were used in the experiments, and they modulation range was from 1 532.0 to 1 548.0 nm. Transient temperature of a certain type of gun barrel was tested when it fired, and test data from the system were compared to WRP-130S high-speed temperature detector. Experimental results show that the two methods are similar ones with average error of less than 2%, and better than 1% in the region of temperature steady drop. 1 ℃ can cause 0.041 3 nm wavelength shift in temperature-wavelength data. Transient temperatures of 50 independent positions can be obtained in an acquisition, so the efficiency of the barrel temperature field reconstruction is greatly improving.

SELECTION OF CITATIONS
SEARCH DETAIL
...