Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Publication year range
1.
Se Pu ; 42(5): 452-457, 2024 Apr 08.
Article in Chinese | MEDLINE | ID: mdl-38736388

ABSTRACT

The applications of organic-amine desulfurization have steadily increased owing to its high efficiency, low cost, and low energy consumption. Different proportions of organic amines exert different effects on sulfur dioxide removal. Therefore, the accurate determination of different organic amines in the desulfurization solution is of great importance. The ion-chromatographic method for the detection of organic amines does not require a derivatization step, has simple pretreatment procedures, and allows for the simultaneous determination of many types of organic amines. In this study, a method based on ion chromatography was developed for the simultaneous determination of ethanolamine (MEA), diethylethanolamine (DEEA), n-methyldiethanolamine (MDEA), 2-amino-2-methyl-1-propanol (AMP), hydroxyethylethylenediamine (AEEA), piperazine (PZ), n-hydroxyethylpiperazine (HEPZ), and diethylenetriamine (DETA). The separation efficiency of the eight organic amines in different types of columns, leaching solutions, and column temperatures were compared. The determination was performed using an IonPac CS17 column with column temperature of 35 ℃ and gradient leaching with methyl sulfonic acid (MSA) solution via the inhibition conductance method. Samples of the desulfurization solution were analyzed using ultrapure water filtered through a 0.22 µm nylon microporous filter membrane and an OnGuard Ⅱ RP column; thus, the pretreatment steps are simple. The eight organic amines showed a good linear relationship within a certain concentration range, and the coefficient of determinations (R2) were greater than 0.998. The limits of detection (LODs) and quantification (LOQs) were determined from the mass concentrations of the organic amines corresponding to signal-to-noise ratios (S/N) of 3 and 10, respectively. LODs of 0.02-0.08 mg/L and LOQs of 0.07-0.27 mg/L were determined from a 1.0 µL sample injection. The actual recoveries ranged from 93.0% to 111%, and the relative standard deviations (RSDs, n=5) ranged from 0.31% to 1.2%. The results indicated that the proposed method has good accuracy and precision; thus, it is suitable for the determination of various organic amines in desulfurization solution.

2.
Sci Total Environ ; 939: 173636, 2024 Aug 20.
Article in English | MEDLINE | ID: mdl-38821278

ABSTRACT

Low-molecular-weight (LMW) organic acids are among the most abundant water-soluble organic compounds, but their gas-particle partitioning mechanism remains unclear. In the present study, LMW organic acids were measured using a URG 9000D Ambient Ion Monitor in suburban Shanghai. The average concentrations of formic acid, acetic acid, oxalic acid, and methanesulfonic acid (MSA) in PM2.5 were 405 ± 116, 413 ± 11, 475 ± 266, and 161 ± 54 ng m-3, respectively. The particle fraction exceeded 30 % for formic acid and acetic acid. Model predictions underestimated the particle-phase monocarboxylic acids (MCAs) from the factor of 102 at the highest RH to 107 at the lowest RH. The average measured intrinsic Henry's law constants (Hmea) for formic acid, acetic acid, oxalic acid, and MSA were 3.8 × 107, 4.5 × 107, 8.7 × 108, and 3.4 × 107 mol L-1 atm-1, respectively, approximately four orders of magnitude higher than their literature-based intrinsic Henry's law constants (Hlit) for MCAs and approximately four orders of magnitude lower than Hlit, MSA. The ratio of Hmea /Hlit for MCAs ranged over three orders of magnitude, depending on relative humidity. The strong deviations at low RHs are attributed to the dominance of absorption by the organic phase. The discrepancy at the highest RH possibly relates to surfactant effects and dimer formation. We used Hmea as a model input for the first time to estimate the phase partitioning of particulate MCAs, finding that >80 % of MCAs resided in the organic phase under dry conditions. We propose parameterizing Hmea as model input to predict the multiphase partitioning of MCAs.

3.
Se Pu ; 41(12): 1121-1126, 2023 Dec.
Article in Chinese | MEDLINE | ID: mdl-38093542

ABSTRACT

Boron and silicon are widely distributed in nature; in water, these compounds typically present in the forms of boric acid and silicic acid, respectively. The maximum allowable levels of silicic acid and boric acid in water are stipulated in relevant national and industry standards, such as GB 8538-2022. Quality changes in water, which are of great significance in water-quality evaluations, can be understood in terms of its silicic acid and boric acid contents. Boric acid content is usually determined by ion exclusion chromatography, whereas silicic acid content is usually determined by postcolumn derivatization. Therefore, traditional methods cannot achieve the simultaneous determination of silicic acid and boric acid contents in water. Modern ion chromatography has been widely used in the detection of ionic compounds, such as anions, cations, organic acids, organic amines, amino acids, and sugars. Boric (pKa=9.24) and silicic (pKa=9.77) acids are weak acids that dissociate into ionic states under alkaline conditions. Although these compounds cannot be tested using suppressed ion chromatography, they can be retained on ion chromatography columns. In this study, a method based on nonsuppressed conductance detection was established for the simultaneous determination of boric acid and silicic acid in water. The contents of boric acid and silicic acid were detected by nonsuppressed ion chromatography using a Dionex IonPacTM AS20 analytical column. The chromatographic conditions were as follows: flow rate, 1.0 mL/min; column temperature, 30 ℃; eluent, 6 mmol/L sodium hydroxide solution and 60 mmol/L mannitol; and sample injection volume, 50 µL. The effective separation of silicic acid and boric acid was achieved within 8 min. SiO32- and boric acid demonstrated good linear relationships in the concentration ranges of 0.25-100 and 0.5-100 mg/L (correlation coefficients, 0.9999), respectively. The method detection (MDL) and quantification (MQL) limits were 0.078 and 0.26 mg/L for SiO32-, and the MDL and MQL limits were 0.18 and 0.60 mg/L for boric acid. The average recoveries of boric acid and SiO32- (n=6) were 97.3%-105.3%. Moreover, the relative standard deviations were less than 0.9% for boric acid at four spiked levels and less than 0.30% for SiO32- at three spiked levels. Thus, the method meets detection requirements. The pretreatment method is very simple, and the sample can be directly injected through a 0.22 µm water filtration membrane and into the column. The boric acid and silicic acid contents in nine mineral drinking water samples were determined under the optimized analytical conditions. Boric acid was not detected in these nine samples, but silicic acid was detected in six samples. The silicic acid contents detected were between 18.70 and 62.08 mg/L, which was consistent with the concentration ranges marked on the manufacturers' packaging. The proposed method can be used for the determination of boric acid and silicic acid in mineral drinking water and laboratory water, and provides a reference for the simultaneous detection of boric acid and silicic acid in ultrapure water used in the semiconductor industry.

4.
J Agric Food Chem ; 71(42): 15855-15862, 2023 Oct 25.
Article in English | MEDLINE | ID: mdl-37831971

ABSTRACT

In this paper, a high-performance ion exclusion chromatographic (ICE) method was developed and applied for monitoring maleic hydrazide (MH) translocation in complex potato plant tissue and tuber matrices. After middle leaf uptake, most MH was trapped and dissipated in the middle leaf, and the rest was transported to other parts mainly through the phloem. Soil absorption significantly reduced the uptake efficiency of the root system, in which MH was partitioned to dissipate in root protoplasts or transfer through the xylem and persisted in the plant. Tuber uptake enabled MH to remain in the flesh and maintain stable levels under storage conditions, but during germination, MH was translocated from the flesh to the growing buds, where it dissipated through the short-day photoperiodic regime. The results demonstrated successful application of the ICE method and provided necessary insights for real-time monitoring of MH translocation behavior to effectively improve potato edible safety.


Subject(s)
Maleic Hydrazide , Solanum tuberosum , Maleic Hydrazide/analysis , Plant Tubers/chemistry , Plants , Chromatography, Gel
5.
Se Pu ; 41(6): 497-503, 2023 Jun 08.
Article in Chinese | MEDLINE | ID: mdl-37259874

ABSTRACT

Fluoroacetic acid is a highly polar poison used for rodent control. When ingested by the human body, it seriously damages nerve cells and heart tissues and even causes death by cardiac arrest or respiratory failure. Common detection methods for fluoroacetic acid include gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry, both of which require complex pretreatment methods, such as derivatization. In this study, a method to determine fluoroacetic acid in human blood and urine based on accelerated solvent extraction-ion chromatography-mass spectrometry (ASE-IC-MS) was established. Two pretreatment methods, namely, acetonitrile precipitation and accelerated solvent extraction, were compared. Furthermore, the effects of different extraction conditions, such as the extraction time, extraction temperature, and number of cycles, were investigated. The most suitable chromatographic separation conditions, such as the chromatographic column, column temperature, and elution procedure, were determined, and the MS conditions, such as the collision energy (CE) and declustering potential (DP) of the ion pairs of the target compound, were investigated. Based on the experimental results, the optimal pretreatment methods and detection conditions were obtained, and reliable data were collected. Deionized water was used as the extraction solvent, and blood and urine samples were processed by accelerated solvent extractor. The supernatant was sequentially collected via centrifugal ultrafiltration and 0.22 µm membrane filtration, diluted 50 times, and then injected into the chromatographic column for detection. An Ion Pac AS20 IC column was used for isocratic elution with 15.0 mmol/L KOH solution as the eluent. The effluent was passed through a suppressor and into a triple quadrupole mass spectrometer, which was used to perform MS/MS (ESI-) in multiple reaction monitoring (MRM) mode. The quantitative ion was m/z 77.0>57.0 when the CE and DP were -15.0 eV and -20.0 V, respectively. An external standard method was used for quantitative analysis. The results showed a good linear relationship for fluoroacetic acid in the range of 0.5-500.0 µg/L (r>0.999), with limits of detection (LOD) and quantification (LOQ) of 0.14 and 0.47 µg/L, respectively. The recoveries of fluoroacetic acid in blood and urine were 93.4%-95.8% and 96.2%-98.4%, respectively. The intra-day RSDs for blood and urine were 0.8%-1.6% and 0.2%-1.0%, respectively, while the inter-day RSDs were 2.3%-3.8% and 3.9%-6.9%, respectively. Further investigation revealed that the matrix effects of this method in blood and urine, at -7.4% and -3.0%, respectively, were fairly weak. The established method was successfully applied to detect fluoroacetic acid in human blood and urine obtained from a poisoning case, and the results obtained provided crucial clues that led to swift case resolution. The efficiency of the method was significantly higher than that of conventional detection methods. In conclusion, the developed method has high sensitivity and good repeatability and is suitable for the rapid detection of fluoroacetic acid in human blood and urine. Moreover, because this method does not require derivatization, it is simple and efficient.


Subject(s)
Fluoroacetates , Tandem Mass Spectrometry , Humans , Spectrum Analysis , Gas Chromatography-Mass Spectrometry , Chromatography, High Pressure Liquid
6.
Chem Commun (Camb) ; 55(21): 3152-3155, 2019 Mar 07.
Article in English | MEDLINE | ID: mdl-30801101

ABSTRACT

NH3 is an important chemical with a wide range of applications, but its synthesis mainly relies upon the harsh Haber-Bosch process with huge CO2 emission. Electrochemical N2 reduction offers a carbon-neutral process to convert N2 to NH3 under ambient conditions, but it requires efficient and stable catalysts to drive the N2 reduction reaction. Herein, we report that a sulfur dots-graphene nanohybrid acts as a metal-free electrocatalyst for ambient N2-to-NH3 conversion with excellent selectivity. When operated in 0.5 M LiClO4, this electrocatalyst achieves a large NH3 yield of 28.56 µg h-1 mgcat.-1 and a high Faradaic efficiency of 7.07% at -0.85 V vs. reversible hydrogen electrode. Notably, it also shows good electrochemical stability.

7.
Inorg Chem ; 58(4): 2257-2260, 2019 Feb 18.
Article in English | MEDLINE | ID: mdl-30688065

ABSTRACT

Electrochemical reduction is an eco-friendly alternative for energy-saving artificial N2 fixation. The development of this process requires efficient N2 reduction reaction (NRR) electrocatalysts to overcome the challenge with N2 activation. We show that a Cr2O3 nanoparticle-reduced graphene oxide hybrid (Cr2O3-rGO) is as an outstanding catalyst for electrochemical N2-to-NH3 conversion under ambient conditions. In 0.1 M HCl, Cr2O3-rGO achieves a high NH3 yield of 33.3 µg h-1 mg-1cat. at -0.7 V vs RHE and a high Faradaic efficiency of 7.33% at -0.6 V vs RHE, with excellent selectivity for NH3 synthesis and stability. Density functional theory calculations were executed to gain further insight into the mechanisms.

8.
Nanoscale ; 11(4): 1555-1562, 2019 Jan 23.
Article in English | MEDLINE | ID: mdl-30637419

ABSTRACT

Artificial N2 fixation via the Haber-Bosch process requires high temperature and high pressure at the expense of CO2 release. Electrochemical NH3 synthesis is emerging as an environmentally friendly alternative that operates under ambient conditions, calling for electrocatalysts with efficient N2 reduction reaction (NRR) performance. In this paper, we experimentally and theoretically prove that defective TiO2 on Ti mesh (d-TiO2/TM) acts as an electrocatalyst for the NRR. In 0.1 M HCl, d-TiO2/TM achieves a much higher NH3 yield of 1.24 × 10-10 mol s-1 cm-2 and FE of 9.17% at -0.15 V (versus reversible hydrogen electrode) than pristine TiO2 (NH3 yield: 0.17 × 10-10 mol s-1 cm-2; FE: 0.95%). Notably, d-TiO2/TM also shows great electrochemical stability and durability. Theoretical investigation further reveals the possible catalytic mechanism involved.

9.
Wei Sheng Yan Jiu ; 41(4): 658-61, 2012 Jul.
Article in Chinese | MEDLINE | ID: mdl-23057335

ABSTRACT

OBJECTIVE: A method for determination of nitrate (NO3(-)) and sulfate (SO4(2-)) in air of residential areas by ion-chromatography (IC) was established. METHODS: The anions in aerosol samples collected with filter member were extracted by ultrasonic leaching and separated on IonPac AS11-HC analytical column and IonPac AG11-HC guard column with 20.0 mmol/L potassium hydroxide eluted at 1.00 ml/min, and then detected by DS6 suppressed conductivity detector, with the satisfactory determination of atmospheric nitrate and sulfate. RESULTS: The correlation coefficient of nitrate and sulfate were greater than 0.9999. The quantification limit of NO3(-) and SO4(2-) was 0.011 microg/m3 and 0.024 microg/m3 respectively. The sampling filter members were divided into four parts equally and spiked, and the recoveries of nitrate and sulfate were 99.6% - 105.6%. The relative standard deviation (RSD) of nitrate and sulfate were less than 3%. CONCLUSION: The method was simple, rapid, reproductive and sensitive for determination of nitrate and sulfate in air of residential areas.


Subject(s)
Air Pollutants/analysis , Chromatography, Ion Exchange , Nitrates/analysis , Sulfates/analysis , Aerosols , Anions , Chromatography
SELECTION OF CITATIONS
SEARCH DETAIL