Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
World J Clin Cases ; 10(22): 7728-7737, 2022 Aug 06.
Article in English | MEDLINE | ID: mdl-36158510

ABSTRACT

BACKGROUND: Radiation therapy, especially the development of linear accelerators, plays a key role in cancer management. The fast-rotating coplanar O-ring Halcyon Linac has demonstrated many advantages. The previous literature has mainly focused on the machine parameters and plan quality of Halcyon, with a lack of relevant research on its clinical application. AIM: To evaluate the clinical performance of the O-ring Halcyon treatment system in a real-world application setting. METHODS: Data from sixty-one patients who were treated with the Halcyon system throughout the entire radiotherapy process in Peking Union Medical College Hospital between August 2019 and September 2020 were retrospectively reviewed. We evaluated the target tumour response to radiotherapy and irradiation toxicity from 1 to 3 mo after treatment. Dosimetric verification of Halcyon plans was performed using a quality assurance procedure, including portal dosimetry, ArcCHECK and point dose measurements for verification of the system delivery accuracy. RESULTS: Of the 61 patients in the five groups, 16, 12, 7 and 26 patients had complete response, partial response, progressive disease and stable disease, respectively. No increase in the irradiated target tumour volume was observed when separately evaluating the local response. Regarding irradiation toxicity, no radiation-induced deaths were observed. Thirty-eight percent (23/61 patients) had no radiation toxicity after radiotherapy, 56% (34/61 patients) experienced radiation toxicity that resolved after treatment, and 6% (4/61 patients) had irreversible adverse reactions. The average gamma passing rates with a 2% dose difference and 2-mm distance to agreement for IMRT/VMAT/SRT plans were ArcCHECK at 96.4% and portal dosimetry at 96.7%, respectively. All of the validated clinical plans were within 3% for point dose measurements, and Halcyon's ArcCHECK demonstrated a high pass rate of 99.1% ± 1.1% for clinical gamma passing criteria of 3%/3 mm. CONCLUSION: The O-ring Halcyon Linac could achieve a better therapeutic effect on the target volume by providing accurate treatment delivery plans with tolerable irradiation toxicity.

2.
Adv Mater ; 30(23): e1707334, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29707827

ABSTRACT

Recently, a new class of 2D materials, i.e., transition metal carbides, nitrides, and carbonitrides known as MXenes, is unveiled with more than 20 types reported one after another. Since they are flexible and conductive, MXenes are expected to compete with graphene and other 2D materials in many applications. Here, a general route is reported to simple self-assembly of transition metal oxide (TMO) nanostructures, including TiO2 nanorods and SnO2 nanowires, on MXene (Ti3 C2 ) nanosheets through van der Waals interactions. The MXene nanosheets, acting as the underlying substrate, not only enable reversible electron and ion transport at the interface but also prevent the TMO nanostructures from aggregation during lithiation/delithiation. The TMO nanostructures, in turn, serve as the spacer to prevent the MXene nanosheets from restacking, thus preserving the active areas from being lost. More importantly, they can contribute extraordinary electrochemical properties, offering short lithium diffusion pathways and additional active sites. The resulting TiO2 /MXene and SnO2 /MXene heterostructures exhibit superior high-rate performance, making them promising high-power and high-energy anode materials for lithium-ion batteries.

SELECTION OF CITATIONS
SEARCH DETAIL