Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Drug Test Anal ; 4(2): 129-35, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21381219

ABSTRACT

The catalytic effect of iodide on the oxidation of four dyes: viz. variamine blue (VB), methylene blue (MB), rhodamine B (RB), and malachite green (MG) with different oxidizing agents was investigated for the kinetic spectrophotometric determination of iodide. The above catalyzed reactions were monitored spectrophotometrically by following the change in dye absorbances at 544, 558, 660, or 617 nm for the VB, RB, MB, or MG catalyzed reactions, respectively. Under optimum conditions, iodide can be determined within the concentration levels 0.064-1.27 µg mL(-1) for VB method, 3.20-9.54 µg mL(-1) for RB method, 5.00-19.00 µg mL(-1) for the MB method, and 6.4-19.0 µg mL(-1) for the MG one, with detection limit reaching 0.004 µg mL(-1) iodide. The reported methods were highly sensitive, selective, and free from most interference. Applying the proposed procedures, trace amounts of iodide in pharmaceutical and edible salt samples were successfully determined without separation or pretreatment steps.


Subject(s)
Iodides/analysis , Pharmaceutical Preparations/chemistry , Sodium Chloride, Dietary/analysis , Spectrophotometry/methods , Catalysis , Coloring Agents/chemistry , Food Analysis/methods , Limit of Detection , Oxidation-Reduction
2.
Talanta ; 83(5): 1538-43, 2011 Feb 15.
Article in English | MEDLINE | ID: mdl-21238749

ABSTRACT

Four sensitive catalytic potentiometric methods have been developed for trace levels determination of iodide based on its catalytic effects on the oxidation of four dyes: viz. variamine blue (VB), rhodamine B (RB), methylene blue (MB) and malachite green (MG), with H(2)O(2) in H(3)PO(4) medium at 25±0.5°C. The catalyzed reaction rates were estimated potentiometrically by monitoring the potential of the corresponding dye-PVC ion selective electrodes. To select the optimized reaction conditions offering the highest sensitivity of the method, parallel studies were carried out on each dye catalyzed reaction including: the effect of reactant concentration, reaction medium and temperature. The working calibration curves were linear over the concentration range from 0.32 to 2.54 mg L(-1) iodide for VB method and from 3.2 to 12.7 mg L(-1) for other ones. The tolerance limits of more than 20 interfering species were listed indicating the high selectivity of the method. Trace iodide in edible salt and pharmaceutical samples was determined without the need for separation or preconcentration procedures.


Subject(s)
Coloring Agents/chemistry , Hydrogen Peroxide/chemistry , Iodides/chemistry , Polyvinyl Chloride/chemistry , Povidone-Iodine/chemistry , Thyroxine/chemistry , Catalysis , Clinical Chemistry Tests/methods , Electrochemistry/methods , Electrodes , Kinetics , Methylene Blue/chemistry , Oxidation-Reduction , Pharmaceutical Preparations/chemistry , Povidone-Iodine/analysis , Thyroxine/analysis
SELECTION OF CITATIONS
SEARCH DETAIL