Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
Add more filters










Publication year range
1.
Methods Mol Biol ; 2625: 347-351, 2023.
Article in English | MEDLINE | ID: mdl-36653656

ABSTRACT

Treatment of lipids endogenous to the aqueous humor of the eye could serve as a potential therapy to slow the progression of glaucoma. Herein, we describe the method to treat trabecular meshwork samples in vitro with lipids and characterize changes in the samples' stiffness.


Subject(s)
Glaucoma , Trabecular Meshwork , Humans , Aqueous Humor , Lipids
2.
PLoS One ; 18(1): e0280616, 2023.
Article in English | MEDLINE | ID: mdl-36662701

ABSTRACT

The meniscus is a fibrocartilaginous tissue that plays an essential role in load transmission, lubrication, and stabilization of the knee. Loss of meniscus function, through degeneration or trauma, can lead to osteoarthritis in the underlying articular cartilage. To perform its crucial function, the meniscus extracellular matrix has a particular organization, including collagen fiber bundles running circumferentially, allowing the tissue to withstand tensile hoop stresses developed during axial loading. Given its critical role in preserving the health of the knee, better understanding structure-function relations of the biomechanical properties of the meniscus is critical. The main objective of this study was to measure the compressive modulus of porcine meniscus using Atomic Force Microscopy (AFM); the effects of three key factors were investigated: direction (axial, circumferential), compartment (medial, lateral) and region (inner, outer). Porcine menisci were prepared in 8 groups (= 2 directions x 2 compartments x 2 regions) with n = 9 per group. A custom AFM was used to obtain force-indentation curves, which were then curve-fit with the Hertz model to determine the tissue's compressive modulus. The compressive modulus ranged from 0.75 to 4.00 MPa across the 8 groups, with an averaged value of 2.04±0.86MPa. Only direction had a significant effect on meniscus compressive modulus (circumferential > axial, p = 0.024), in agreement with earlier studies demonstrating that mechanical properties in the tissue are anisotropic. This behavior is likely the result of the particular collagen fiber arrangement in the tissue and plays a key role in load transmission capability. This study provides important information on the micromechanical properties of the meniscus, which is crucial for understanding tissue pathophysiology, as well as for developing novel treatments for tissue repair.


Subject(s)
Menisci, Tibial , Meniscus , Animals , Swine , Menisci, Tibial/physiology , Anisotropy , Microscopy, Atomic Force , Collagen , Biomechanical Phenomena/physiology
3.
Front Bioeng Biotechnol ; 10: 886483, 2022.
Article in English | MEDLINE | ID: mdl-35651551

ABSTRACT

Pancreatic islet transplantation improves metabolic control and prevents complications in patients with brittle type 1 diabetes (T1D). However, chronic immunosuppression is required to prevent allograft rejection and recurrence of autoimmunity. Islet encapsulation may eliminate the need for immunosuppression. Here, we analyzed in parallel two microencapsulation platforms that provided long-term diabetes reversal in preclinical T1D models, alginate single and double capsules versus polyethylene glycol conformal coating, to identify benefits and weaknesses that could inform the design of future clinical trials with microencapsulated islets. We performed in vitro and in vivo functionality assays with human islets and analyzed the explanted grafts by immunofluorescence. We quantified the size of islets and capsules, measured capsule permeability, and used these data for in silico simulations of islet functionality in COMSOL Multiphysics. We demonstrated that insulin response to glucose stimulation is dependent on capsule size, and the presence of permselective materials augments delays in insulin secretion. Non-coated and conformally coated islets could be transplanted into the fat pad of diabetic mice, resulting in comparable functionality and metabolic control. Mac-2+ cells were found in conformally coated grafts, indicating possible host reactivity. Due to their larger volume, alginate capsules were transplanted in the peritoneal cavity. Despite achieving diabetes reversal, changes in islet composition were found in retrieved capsules, and recipient mice experienced hypoglycemia indicative of hyperinsulinemia induced by glucose retention in large capsules as the in silico model predicted. We concluded that minimal capsule size is critical for physiological insulin secretion, and anti-inflammatory modulation may be beneficial for small conformal capsules.

4.
Sci Adv ; 8(26): eabm3145, 2022 07.
Article in English | MEDLINE | ID: mdl-35767620

ABSTRACT

Polyethylene glycol (PEG)-based conformal coating (CC) encapsulation of transplanted islets is a promising ß cell replacement therapy for the treatment of type 1 diabetes without chronic immunosuppression because it minimizes capsule thickness, graft volume, and insulin secretion delay. However, we show here that our original CC method, the direct method, requiring exposure of islets to low pH levels and inclusion of viscosity enhancers during coating, severely affected the viability, scalability, and biocompatibility of CC islets in nonhuman primate preclinical models of type 1 diabetes. We therefore developed and validated in vitro and in vivo, in several small- and large-animal models of type 1 diabetes, an augmented CC method-emulsion method-that achieves hydrogel CCs around islets at physiological pH for improved cytocompatibility, with PEG hydrogels for increased biocompatibility and with fivefold increase in encapsulation throughput for enhanced scalability.


Subject(s)
Diabetes Mellitus, Type 1 , Islets of Langerhans Transplantation , Islets of Langerhans , Animals , Diabetes Mellitus, Type 1/metabolism , Diabetes Mellitus, Type 1/therapy , Emulsions , Islets of Langerhans/metabolism , Islets of Langerhans Transplantation/methods , Primates , Rodentia
5.
Adv Funct Mater ; 30(25)2020 Jun 18.
Article in English | MEDLINE | ID: mdl-32982626

ABSTRACT

Scaffolds made from biocompatible polymers provide physical cues to direct the extension of neurites and to encourage repair of damaged nerves. The inclusion of neurotrophic payloads in these scaffolds can substantially enhance regrowth and repair processes. However, many promising neurotrophic candidates are excluded from this approach due to incompatibilities with the polymer or with the polymer processing conditions. This work provides one solution to this problem by incorporating porous silicon nanoparticles (pSiNPs) that are pre-loaded with the therapeutic into a polymer scaffold during fabrication. The nanoparticle-drug-polymer hybrids are prepared in the form of oriented poly(lactic-co-glycolic acid) nanofiber scaffolds. We test three different therapeutic payloads: bpV(HOpic), a small molecule inhibitor of phosphatase and tensin homolog (PTEN); an RNA aptamer specific to tropomyosin-related kinase receptor type B (TrkB); and the protein nerve growth factor (NGF). Each therapeutic is loaded using a loading chemistry that is optimized to slow the rate of release of these water-soluble payloads. The drug-loaded pSiNP-nanofiber hybrids release approximately half of their TrkB aptamer, bpV(HOpic), or NGF payload in 2, 10, and >40 days, respectively. The nanofiber hybrids increase neurite extension relative to drug-free control nanofibers in a dorsal root ganglion explant assay.

6.
Invest Ophthalmol Vis Sci ; 61(5): 61, 2020 05 11.
Article in English | MEDLINE | ID: mdl-32462201

ABSTRACT

Purpose: The aim of this study was to determine the roles of collagen XII in the regulation of stromal hierarchical organization, keratocyte organization, and corneal mechanics. Methods: The temporal and spatial expression of collagen XII at postnatal days 4, 10, 30, 90, and 150 were evaluated in wild-type (WT) mice. The role of collagen XII in hierarchical organization was analyzed by measuring fibril diameter and density, as well as stromal lamellar structure, within ultrastructural micrographs obtained from WT and collagen XII-deficient mice (Col12a1-/-). Keratocyte morphology and networks were assessed using actin staining with phalloidin and in vivo confocal microscopy. The effects of collagen XII on corneal biomechanics were evaluated with atomic force microscopy. Results: Collagen XII was localized homogeneously in the stroma from postnatal day 4 to day 150, and protein accumulation was shown to increase during this period using semiquantitative immunoblots. Higher fibril density (P < 0.001) and disruption of lamellar organization were found in the collagen XII null mice stroma when compared to WT mice. Keratocyte networks and organization were altered in the absence of collagen XII, as demonstrated using fluorescent microscopy after phalloidin staining and in vivo confocal microscopy. Corneal stiffness was increased in the absence of collagen XII. Young's modulus was 16.2 ± 5.6 kPa in WT and 32.8 ± 6.4 kPa in Col12a1-/- corneas. The difference between these two groups was significant (P < 0.001, t-test). Conclusions: Collagen XII plays a major role in establishing and maintaining stromal structure and function. In the absence of collagen XII, the corneal stroma showed significant abnormalities, including decreased interfibrillar space, disrupted lamellar organization, abnormal keratocyte organization, and increased corneal stiffness.


Subject(s)
Collagen Type XII/physiology , Corneal Stroma/anatomy & histology , Corneal Stroma/physiology , Age Factors , Animals , Animals, Newborn , Collagen Type XII/biosynthesis , Corneal Keratocytes/physiology , Male , Mice
7.
Mol Vis ; 25: 593-xxx, 2019.
Article in English | MEDLINE | ID: mdl-31741652

ABSTRACT

Purpose: To quantify the partition coefficient and the diffusion coefficient of metal-carrier proteins in the human lens capsule as a function of age. Methods: Whole lenses from human donors were incubated overnight in a solution of fluorescently labeled transferrin, albumin, or ceruloplasmin. In the central plane of the capsule thickness, fluorescence recovery after photobleaching (FRAP) experiments were conducted to measure the diffusion of the protein within the lens capsule. The anterior portion of the lens was recorded before the FRAP experiments to locate the boundaries of the anterior lens capsule and to measure the partition coefficient of the labeled proteins. The partition coefficient (P), the time to half maximum recovery of the fluorescent intensity (τ1/2), and the diffusion coefficient (D) for each protein were analyzed as a function of donor age. Results: There was no statistically significant relationship between the half maximum recovery time or the diffusion coefficient and age for transferrin (molecular weight [MW]=79.5 kDa, τ1/2=17.26±4.840 s, D=0.17±0.05 µm2/s), serum albumin (MW=66.5 kDa, τ1/2=18.45±6.110 s, D=0.17±0.06 µm2/s), or ceruloplasmin (MW=120 kDa, τ1/2=36.57±5.660 s, D=0.08±0.01 µm2/s). As expected, the larger protein (ceruloplasmin) took longer to recover fluorescent intensity due to its slower movement within the lens capsule. The partition coefficient statistically significantly increased with age for each protein (Palbumin: 0.09-0.71, Pceruloplasmin: 0.42-0.95, Ptransferrin: 0.19-1.17). Conclusions: The diffusion of heavy-metal protein carriers within the anterior lens capsule is not dependent on age, but it is dependent on the size of the protein. The permeability of the lens capsule to these heavy-metal protein carriers increases with age, suggesting that there will be a higher concentration of heavy metals in the older lens. This behavior may favor the formation of cataract, because heavy metals enhance protein oxidation through the Fenton reaction.


Subject(s)
Aging/physiology , Fluorescence Recovery After Photobleaching , Lens Capsule, Crystalline/diagnostic imaging , Adult , Aged , Albumins/metabolism , Ceruloplasmin/metabolism , Diffusion , Humans , Lens Capsule, Crystalline/metabolism , Middle Aged , Transferrin/metabolism , Young Adult
8.
Macromol Mater Eng ; 304(4)2019 Apr.
Article in English | MEDLINE | ID: mdl-31929732

ABSTRACT

Islet transplantation within mechanically stable microcapsules offers the promise of long-term diabetes reversal without chronic immunosuppression. Reinforcing the ionically gelled network of alginate (ALG) hydrogels with covalently linked polyethylene glycol (PEG) may create hybrid structures with desirable mechanical properties. This report describes the fabrication of hybrid PEG-ALG interpenetrating polymer networks and the investigation of microcapsule swelling, surface modulus, rheology, compression, and permeability. It is demonstrated that hybrid networks are more resistant to bulk swelling and compressive deformation and display improved shape recovery and long-term resilience. Interestingly, it is shown that PEG-ALG networks behave like ALG during microscale surface deformation and small amplitude shear while exhibiting similar permeability properties. The results from this report's in vitro characterization are interpreted according to viscoelastic polymer theory and provide new insight into hybrid hydrogel mechanical behavior. This new understanding of PEG-ALG mechanical performance is then linked to previous work that demonstrated the success of hybrid polymer immunoisolation devices in vivo.

9.
Mol Vis ; 24: 902-912, 2018.
Article in English | MEDLINE | ID: mdl-30713427

ABSTRACT

PURPOSE: This study aimed to quantify the three-dimensional micromorphology of the surface of the human lens capsule as a function of age. METHODS: Imaging experiments were conducted on whole human lenses received from eight human cadavers (donor age range: 30-88 years). Imaging was performed with an atomic force microscope (AFM) in contact mode in fluid. The porosity and surface roughness were quantified from the height images obtained. A novel approach, based on stereometric and fractal analysis of three-dimensional surfaces developed for use in conjunction with AFM data, was also used to analyze the surface microtexture as a function of age. RESULTS: The AFM images obtained depict a highly ordered fibrous structure at the surface of the lens capsule, although the overall structure visually changes with age. Porosity and roughness were quantified for each image and analyzed as a function of donor age. The interfibrillar spacing revealed an increasing trend with age, although this result was not significant (p = 0.110). The root mean square (RMS) deviation and average deviation significantly decreased with increasing age (p<0.001 for both). The fractal analysis provided quantitative values for 29 amplitude, hybrid, functional, and spatial parameters. All the hybrid parameters decreased with age, although not significantly. Of the functional parameters, the surface bearing index increased significantly with age (p = 0.017) and the summit height exhibited a decreasing trend with age (p = 0.298). Of the spatial parameters, the dominant radial wavelength trend moved toward an increase with age (p = 0.103) and the cross-hatch angle tended toward a decrease with age (p = 0.213). CONCLUSIONS: Significant changes in the three-dimensional surface microtexture of the human lens capsule were found with age, although more experiments on a larger dataset are needed to conclude this with certainty. The analyzed AFM images demonstrate a fractal nature of the surface, which is not considered in classical surface statistical parameters. The surface fractal dimension may be useful in ophthalmology for quantifying human lens architectural changes associated with different disease states to further our understanding of disease evolution.


Subject(s)
Imaging, Three-Dimensional/methods , Lens Capsule, Crystalline/ultrastructure , Adult , Age Factors , Aged , Aged, 80 and over , Cadaver , Female , Fractals , Humans , Imaging, Three-Dimensional/instrumentation , Lens Capsule, Crystalline/anatomy & histology , Lens Capsule, Crystalline/diagnostic imaging , Male , Microscopy, Atomic Force/methods , Middle Aged
10.
Exp Eye Res ; 153: 51-55, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27725199

ABSTRACT

The purpose of this study was to assess anterior and mid corneal stromal elasticity after high intensity (HI) corneal cross linking (CXL), with and without oxygen (O2) enrichment, and compare these results to conventional CXL. Experiments were performed on 25 pairs of human cadaver eyes, divided into four different groups. Group 1 included corneas that did not receive treatment and served as controls; Group 2 included corneas that received conventional CXL treatment (Dresden Protocol: corneal epithelial debridement, 30 min of riboflavin pretreatment followed by 30 min of exposure to 3 mW/cm2 of ultraviolet light); Group 3 included corneas that received HI CXL treatment (corneal epithelial debridement, 30 min of riboflavin pretreatment followed by 3 min of exposure to 30mW/cm2 of ultraviolet light); and Group 4 included corneas that received the same treatment as Group 3, except that they were enriched with oxygen (4 L per minute pure O2 gas stream) during ultraviolet irradiation. In each group, corneas were subdivided to assess anterior stromal elasticity and mid stromal elasticity. Corneal stromal elasticity was quantified using Atomic Force Microscopy (AFM) through micro-indentation. Young's modulus for the anterior corneal stroma was 14.5 ± 6.0 kPa, 80.7 ± 44.6 kPa, 36.6 ± 10.5 kPa, and 30.6 ± 9.2 kPa, for groups 1, 2, 3 and 4 respectively. Young's modulus for the mid corneal stroma was 5.8 ± 2.0 kPa, 20.7 ± 4.3 kPa, 12.1 ± 4.9 kPa, and 11.7 ± 3.7 kPa, for groups 1, 2, 3 and 4, respectively. In the anterior stromal region, conventional CXL demonstrated a significantly different result from the control, whereas the two HI CXL protocols were not significantly different from the control. There were no statistical differences between the two HI CXL protocols, although only the HI CXL protocol with O2 enrichment was significantly different from the conventional CXL group. In the mid stromal region, once again only conventional CXL demonstrated a significantly different result from the control. There were no statistical differences between the two HI CXL protocols, and both HI CXL protocols were significantly different from the conventional CXL group. Oxygen enriched HI CXL seems to offer similar changes in corneal elasticity when compared to HI CXL without the presence O2. Conventional CXL increases corneal stiffness more than HI CXL both with and without O2 enrichment.


Subject(s)
Cornea/physiology , Cross-Linking Reagents/pharmacology , Microscopy, Atomic Force/methods , Oxygen/metabolism , Adult , Aged , Cadaver , Cornea/drug effects , Cornea/radiation effects , Elasticity , Female , Humans , Male , Middle Aged , Ultraviolet Rays , Young Adult
11.
J Vasc Access ; 17(3): 279-83, 2016 May 07.
Article in English | MEDLINE | ID: mdl-27032456

ABSTRACT

PURPOSE: This study presents a method to quantify micro-stiffness variations in experimental arteriovenous fistulae (AVF). METHODS: AVF created by anastomosing the superficial epigastric vein to the femoral artery in Sprague-Dawley rats were allowed to remodel for 21 days before being harvested and preserved in culture medium. A custom atomic force microscope was used to measure microvascular stiffness (Young's modulus) in three areas of the AVF: the inflow artery, the juxta-anastomotic area, and the outflow vein. Morphometric measurements and collagen and elastin contents were also determined. RESULTS: Atomic force microscopy indentation revealed an increased stiffness in the juxta-anastomotic area of the AVF compared to the outflow vein and inflow artery. The juxta-anastomotic area was also significantly stiffer than the contralateral vein. The lack of elasticity (higher Young's modulus) of the juxta-anastomotic region was associated with a thicker vascular wall that was rich in collagen but poor in elastin. CONCLUSIONS: This study demonstrates for the first time the feasibility of using atomic force microscopy to measure local stiffness variations in experimental AVF. This technique could be instrumental in advancing our understanding of how micro-spatial organization of the AVF wall determines the overall biomechanical performance of this type of vascular access.


Subject(s)
Arteriovenous Shunt, Surgical , Femoral Artery/surgery , Microscopy, Atomic Force , Vascular Stiffness , Veins/surgery , Animals , Biomechanical Phenomena , Collagen/metabolism , Elastic Modulus , Elastin/metabolism , Femoral Artery/metabolism , Femoral Artery/physiopathology , Male , Models, Animal , Rats, Sprague-Dawley , Regional Blood Flow , Time Factors , Vascular Remodeling , Veins/metabolism , Veins/physiopathology
12.
Invest Ophthalmol Vis Sci ; 56(6): 4053-60, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26098472

ABSTRACT

PURPOSE: To investigate the depth-dependent mechanical anisotropy of the human corneal stroma at the tissue (stroma) and molecular (collagen) level by using atomic force microscopy (AFM). METHODS: Eleven human donor corneas were dissected at different stromal depths by using a microkeratome. Mechanical measurements were performed in 15% dextran on the surface of the exposed stroma of each sample by using a custom-built AFM in force spectroscopy mode using both microspherical (38-µm diameter) and nanoconical (10-nm radius of curvature) indenters at 2-µm/s and 15-µm/s indentation rates. Young's modulus was determined by fitting force curve data using the Hertz and Hertz-Sneddon models for a spherical and a conical indenter, respectively. The depth-dependent anisotropy of stromal elasticity was correlated with images of the corneal stroma acquired by two-photon microscopy. RESULTS: The force curves were obtained at stromal depths ranging from 59 to 218 µm. At the tissue level, Young's modulus (ES) showed a steep decrease at approximately 140-µm stromal depth (from 0.8 MPa to 0.3 MPa; P = 0.03) and then was stable in the posterior stroma. At the molecular level, Young's modulus (EC) was significantly greater than at the tissue level; EC decreased nonlinearly with increasing stromal depth from 3.9 to 2.6 MPa (P = 0.04). The variation of microstructure through the thickness correlated highly with a nonconstant profile of the mechanical properties in the stroma. CONCLUSIONS: The corneal stroma exhibits unique anisotropic elastic behavior at the tissue and molecular levels. This knowledge may benefit modeling of corneal behavior and help in the development of biomimetic materials.


Subject(s)
Corneal Stroma/physiology , Elasticity/physiology , Adult , Aged , Aged, 80 and over , Anisotropy , Collagen/physiology , Elastic Modulus , Elasticity Imaging Techniques , Female , Humans , Male , Microscopy, Atomic Force/methods , Middle Aged , Models, Theoretical , Young Adult
13.
Exp Eye Res ; 138: 1-5, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26093276

ABSTRACT

The purpose of this study was to evaluate elasticity and viscoelasticity in the anterior and deeper stromal regions of the cornea after cross linking with three different protocols using atomic force microscopy (AFM) through indentation. A total of 40 porcine corneas were used in this study and were divided into 4 groups (10 corneas per group): control (no treatment), Dresden (corneal epithelial debridement, riboflavin pretreatment for 30 min and a 3mw/cm(2) for 30 min UVA irradiation), accelerated (corneal epithelial debridement, riboflavin pretreatment for 30 min and a 30mw/cm(2) for 3 min UVA irradiation), and genipin (corneal epithelial debridement and submersion of anterior surface in a 1% genipin solution for 4 h). Elasticity and viscoelasticity were quantified using AFM through indentation for all corneas, for the anterior stroma and at a depth of 200 µm. For the control, Dresden, accelerated, and genipin groups, respectively, the average Young's modulus for the anterior stromal region was 0.60 ± 0.58 MPa, 1.58 ± 1.04 MPa, 0.86 ± 0.46 MPa, and 1.71 ± 0.51 MPa; the average for the 200 µm stromal depth was 0.08 ± 0.06 MPa, 0.08 ± 0.04 MPa, 0.08 ± 0.04 MPa, and 0.06 ± 0.01 MPa. Corneas crosslinked with the Dresden protocol and genipin were significantly stiffer than controls (p < 0.05) in the anterior region only. For the control, Dresden, Accelerated, and genipin groups, respectively, the average calculated apparent viscosity for the anterior stroma was 88.2 ± 43.7 kPa-s, 8.3 ± 7.1 kPa-s, 8.1 ± 2.3 kPa-s, and 9.5 ± 3.8 kPa-s; the average for the 200 µm stromal depth was 35.0 ± 3.7 kPa-s, 49.6 ± 35.1 kPa-s, 42.4 ± 17.6 kPa-s, and 41.8 ± 37.6 kPa-s. All crosslinking protocols resulted in a decrease in viscosity in the anterior region only (p < 0.05). The effects of cross-linking seem to be limited to the anterior corneal stroma and do not extend to the deeper stromal region. Additionally, the Dresden and genipin protocols seem to produce a stiffer anterior corneal stroma when compared to the accelerated protocol.


Subject(s)
Corneal Stroma/physiology , Cross-Linking Reagents/pharmacology , Elasticity Imaging Techniques/methods , Elasticity/physiology , Microscopy, Atomic Force/methods , Photochemotherapy/methods , Photosensitizing Agents/pharmacology , Animals , Collagen/metabolism , Corneal Pachymetry , Corneal Stroma/drug effects , Riboflavin/pharmacology , Swine , Ultraviolet Rays , Viscosity
14.
Mol Vis ; 21: 316-23, 2015.
Article in English | MEDLINE | ID: mdl-25814829

ABSTRACT

PURPOSE: To image the ultrastructure of the anterior lens capsule at the nanoscale level using atomic force microscopy (AFM). METHODS: Experiments were performed on anterior lens capsules maintained in their in situ location surrounding the lens from six human cadavers (donor age range: 44-88 years), four cynomolgus monkeys (Macaca fascicularis age range: 4.83-8.92 years), and seven pigs (<6 months). Hydration of all samples was maintained using Dulbecco's Modified Eagle Medium (DMEM). Whole lenses were removed from the eye and placed anterior side up in agarose gel before gel hardening where only the posterior half of the lens was contained within the gel. After the gel hardened, the Petri dish was filled with DMEM until the point where the intact lens was fully submerged. AFM was used to image the anterior lens surface in contact mode. An integrated analysis program was used to calculate the interfibrillar spacing, fiber diameter, and surface roughness of the samples. RESULTS: The AFM images depict a highly ordered fibrous structure at the surface of the lens capsule in all three species. The interfibrillar spacing for the porcine, cynomolgus monkey, and human lens capsules was 0.68±0.25, 1.80±0.39, and 1.08±0.25 µm, respectively. In the primate, interfibrillar spacing significantly decreased linearly as a function of age. The fiber diameters ranged from 50 to 950 nm. Comparison of the root mean square (RMS) and average deviation demonstrate that the surface of the porcine lens capsule is the smoothest, and that the human and cynomolgus monkey capsules are significantly rougher. CONCLUSIONS: AFM was successful in providing high-resolution images of the nanostructure of the lens capsule samples. Species-dependent differences were observed in the overall structure and surface roughness.


Subject(s)
Lens Capsule, Crystalline/ultrastructure , Adult , Aged , Aged, 80 and over , Animals , Humans , Macaca fascicularis , Microscopy, Atomic Force , Middle Aged , Species Specificity , Surface Properties , Swine
15.
Eye Contact Lens ; 41(5): 281-6, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25603443

ABSTRACT

OBJECTIVES: To determine the effect of hydration media on ex vivo corneal elasticity. METHODS: Experiments were conducted on 40 porcine eyes retrieved from an abattoir (10 eyes each for phosphate-buffered saline (PBS), balanced salt solution, Optisol, 15% dextran). The epithelium was removed, and the cornea was excised with an intact scleral rim and placed in 20% dextran overnight to restore its physiological thickness. For each hydration media, corneas were evenly divided into two groups: one with an intact scleral rim and the other without. Corneas were mounted onto a custom chamber and immersed in a hydration medium for elasticity testing. Although in each medium, corneal elasticity measurements were performed for 2 hr: at 5-min intervals for the first 30 min and then 15-min intervals for the remaining 90 min. Elasticity testing was performed using nanoindentation with spherical indenters, and Young modulus was calculated using the Hertz model. Thickness measurements were taken before and after elasticity testing. RESULTS: The percentage change in corneal thickness and elasticity was calculated for each hydration media group. Balanced salt solution, PBS, and Optisol showed an increase in thickness and Young moduli for corneas with and without an intact scleral rim. Fifteen percent dextran exhibited a dehydrating effect on corneal thickness and provided stable maintenance of corneal elasticity for both groups. CONCLUSIONS: Hydration media affects the stability of corneal thickness and elasticity measurements over time. Fifteen percent dextran was most effective in maintaining corneal hydration and elasticity, followed by Optisol.


Subject(s)
Chondroitin Sulfates/pharmacology , Cornea/drug effects , Dextrans/pharmacology , Elasticity/physiology , Gentamicins/pharmacology , Ophthalmic Solutions/pharmacology , Animals , Complex Mixtures/pharmacology , Cornea/anatomy & histology , Cornea/physiology , Elastic Modulus/physiology , Swine
16.
J Refract Surg ; 30(6): 388-93, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24972405

ABSTRACT

PURPOSE: To assess the cut quality of the anterior and posterior surfaces of intrastromal refractive lenticules removed during small incision lenticule extraction (SMILE). METHODS: The VisuMax femtosecond laser (500 kHz; Carl Zeiss Meditec, Dublin, CA) was used to perform SMILE on 8 eyes of 5 individuals to correct only myopia (no cylinder). The cut energy index was 26 (equivalent to an energy of 130 nJ) with a 2.5 × 2.5 µm spot/track separation. The lenticule diameter was 6.5 mm with a minimum edge thickness of 15 µm and the cap diameter was 7.3 mm with an intended thickness of 120 µm. After laser treatment, the lenticule was loosened with a spatula and removed with forceps. The extracted lenticules were placed in 2% formalin and sent for imaging with an environmental scanning electron microscope. Images of the anterior and posterior surfaces of the lenticules were obtained at multiple magnifications (100×, 250×, and 500×). Surface quality was evaluated by an investigator who specializes in electron microscopy using three criteria: overall surface regularity, percent of surface irregularity, and position of irregular area. RESULTS: Both the anterior and posterior surfaces of the extracted lenticules were smooth and absent of surface irregularities. The cut edges also appeared uniform. Jagged edges were seen in several images, but were clearly caused by the forceps during extraction. CONCLUSIONS: Using the VisuMax laser to perform SMILE produces smooth cuts absent of surface irregularities.


Subject(s)
Corneal Stroma/ultrastructure , Corneal Surgery, Laser/methods , Lasers, Excimer/therapeutic use , Microscopy, Electron, Scanning , Myopia/surgery , Humans , Surface Properties , Surgical Flaps
17.
Aging (Albany NY) ; 6(12): 1049-63, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25567453

ABSTRACT

Vascular disease is one of the leading causes of death worldwide. Vascular repair, essential for tissue maintenance, is critically reduced during vascular disease and aging. Efficient vascular repair requires functional adult stem cells unimpaired by aging or mutation. One protein candidate for reducing stem cell?mediated vascular repair is progerin, an alternative splice variant of lamin A. Progerin results from erroneous activation of cryptic splice sites within the LMNA gene, and significantly increases during aging. Mutations triggering progerin overexpression cause the premature aging disorder Hutchinson-Gilford Progeria Syndrome (HGPS), in which patients die at approximately 13-years of age due to atherosclerosis-induced disease. Progerin expression affects tissues rich in cells that can be derived from marrow stromal cells (MSCs. Studies using various MSC subpopulations and models have led to discrepant results. Using a well-defined, immature subpopulation of MSCs, Marrow Isolated Adult Multilineage Inducible (MIAMI) cells, we find progerin significantly disrupts expression and localization of self-renewal markers, proliferation, migration, and membrane elasticity. One potential treatment, farnesyltransferase inhibitor, ameliorates some of these effects. Our results confirm proposed progerin-induced mechanisms and suggest novel ways in which progerin disturbs critical stem cell functions collectively required for proper tissue repair, offering promising treatment targets for future therapies.


Subject(s)
Adult Stem Cells/metabolism , Mesenchymal Stem Cells/metabolism , Nuclear Proteins/metabolism , Protein Precursors/metabolism , Regeneration , Adolescent , Adult , Adult Stem Cells/drug effects , Adult Stem Cells/enzymology , Adult Stem Cells/pathology , Aged , Cell Membrane/metabolism , Cell Membrane/pathology , Cell Movement , Cell Proliferation , Child , Enzyme Inhibitors/pharmacology , Farnesyltranstransferase/antagonists & inhibitors , Farnesyltranstransferase/metabolism , Gene Expression Regulation , HEK293 Cells , Humans , Lamin Type A , Male , Membrane Fluidity , Mesenchymal Stem Cells/drug effects , Mesenchymal Stem Cells/enzymology , Mesenchymal Stem Cells/pathology , Middle Aged , Nuclear Proteins/genetics , Protein Precursors/genetics , RNA, Messenger/metabolism , Regeneration/drug effects , Signal Transduction , Time Factors , Transfection , Young Adult
18.
Exp Eye Res ; 116: 58-62, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23933527

ABSTRACT

The purpose of this project was to assess anterior and posterior corneal stromal elasticity after corneal collagen cross linking (CXL) treatment in human cadaver eyes using Atomic Force Microscopy (AFM) through indentation. Twenty four human cadaver eyes (12 pairs) were included in this study and divided into 2 groups (6 pairs per group). In both groups, the left eye (OS) served as a control (no riboflavin or CXL treatment was performed) and the right eye (OD) underwent CXL treatment (30 min of riboflavin pretreatment followed by 30 min of exposure to 3 mW/cm(2) of ultraviolet light). In group 1, the anterior stroma was exposed by manual delamination of approximately 50 µm of the corneal stroma including Bowman's membrane. In group 2, the posterior stroma was exposed by delamination of the anterior 50% of the corneal stroma including Bowman's membrane. Delamination was performed after crosslinking treatment in the case of the treated eyes. In all eyes, the stromal elasticity was quantified using AFM through indentation. Young's modulus of elasticity for the anterior cornea (group 1) was 245.9 ± 209.1 kPa (range: 82.3-530.8 kPa) for the untreated control eyes, and 467.8 ± 373.2 kPa (range: 157.4-1126 kPa) for the CXL treated eyes. Young's modulus for the posterior cornea (group 2) was 100.2 ± 61.9 kPa (range: 28.1-162.6 kPa) for the untreated control eyes and 66.0 ± 31.8 kPa (range: 31.3-101.7 kPa) for the CXL treated eyes. Young's modulus of the anterior stroma significantly increased after CXL treatment (p = 0.024), whereas the posterior stroma did not demonstrate a significant difference in Young's modulus after CXL treatment (p = 0.170). The anterior stroma was stiffer than the posterior stroma for both the control and CXL treatment groups (p = 0.077 and p = 0.023, respectively). Our findings demonstrate that stiffness of the anterior corneal stroma after CXL treatment seems to increase significantly, while the posterior stroma does not seem to be affected by CXL.


Subject(s)
Collagen/pharmacology , Corneal Stroma/physiology , Cross-Linking Reagents , Adult , Aged , Aged, 80 and over , Cadaver , Corneal Stroma/drug effects , Elasticity , Elasticity Imaging Techniques , Humans , Middle Aged
19.
Exp Eye Res ; 115: 41-6, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23800511

ABSTRACT

Corneal biomechanics is an essential parameter for developing diagnostic and treatment methods of corneal-related diseases. It is widely accepted that corneal mechanical strength stems from the stroma's collagenous composition. However, more comprehensive insight into the mechanical properties within the stroma is needed to improve current corneal diagnostic and treatment techniques. The purpose of this study was to perform elasticity characterization of anterior and posterior stromal regions of human corneas using atomic force microscopy (AFM). Nine pairs of human whole globes were placed in 20% Dextran solution, cornea side down, to restore the corneal thickness to physiological levels (400-600 µm). The epithelium and Bowman's membrane were removed from all eyes. Anterior stromal AFM elasticity testing was then performed on left (OS) eyes. Additional stroma was removed from right (OD) eyes to allow posterior stromal measurements at a depth of 50% of the original thickness. All experiments were performed with corneas submerged in 15% Dextran to maintain corneal hydration. The results of the study showed that the Young's modulus of elasticity of the anterior stroma (average: 281 ± 214 kPa; range: 59-764 kPa) was significantly higher than that of the posterior stroma (average: 89.5 ± 46.1 kPa; range: 29-179 kPa) (p = 0.014). In addition, a linear relationship was found between the posterior stromal elasticity and anterior stromal elasticity (p = 0.0428). On average, the elasticity of the posterior stroma is 39.3% of the anterior stroma. In summary, there appears to be an elasticity gradient within the corneal stroma, which should be considered in the design and development of corneal diagnostic and treatment methods to enhance efficacy.


Subject(s)
Corneal Stroma/physiology , Elasticity/physiology , Aged , Aged, 80 and over , Biomechanical Phenomena , Cornea/physiology , Elastic Modulus , Elasticity Imaging Techniques , Humans , Microscopy, Atomic Force , Middle Aged
20.
J Cataract Refract Surg ; 39(1): 110-117, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23141078

ABSTRACT

PURPOSE: To quantify the cut quality of lamellar dissections made with the femtosecond laser using atomic force microscopy (AFM). SETTING: Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA. DESIGN: Experimental study. METHODS: Experiments were performed on 3 pairs of human cadaver eyes. The cornea was thinned to physiologic levels by placing the globe, cornea side down, in 25% dextran for 24 hours. The eyes were reinflated to normal pressures by injecting a balanced salt solution into the vitreous cavity. The eyes were placed in a holder, the epithelium was removed, and the eyes were cut with a Visumax femtosecond laser. The energy level was 180 nJ for the right eye and 340 nJ for the left eye of each pair. The cut depths were 200 µm, 300 µm, and 400 µm, with the cut depth maintained for both eyes of each pair. A 12.0 mm trephination was then performed. The anterior portion of the lamellar surface was placed in a balanced salt solution and imaged with AFM. As a control, the posterior surface was placed in 2% formalin and imaged with environmental scanning electron microscopy (SEM). Four quantitative parameters (root-mean-square deviation, average deviation, skewness, kurtosis) were calculated from the AFM images. RESULTS: From AFM, the 300 µm low-energy cuts were the smoothest. Similar results were seen qualitatively in the environmental SEM images. CONCLUSION: Atomic force microscopy provided quantitative information on the quality of lamellar dissections made using a femtosecond laser, which is useful in optimizing patient outcomes in refractive and lamellar keratoplasty surgeries.


Subject(s)
Corneal Stroma/surgery , Corneal Stroma/ultrastructure , Dissection/methods , Laser Therapy/methods , Microscopy, Atomic Force , Aged , Aged, 80 and over , Cadaver , Corneal Transplantation , Humans , Microscopy, Electron, Scanning , Pilot Projects , Tissue Donors
SELECTION OF CITATIONS
SEARCH DETAIL
...