1.
Article in German | MEDLINE | ID: mdl-38238487

ABSTRACT

BACKGROUND: The digital transformation in medicine, particularly in technology-orientated areas such as rhythmology, is leading to a rapid change in diagnostic and therapeutic options. Digital skills are helpful and need to keep up with this pace of change. RESEARCH QUESTION: Which digital technologies and resources with rhythmological relevance play a role today and in the future? METHODS: Review of the various digital technologies for rhythm detection and monitoring, as well as current digital resources for training and education. RESULTS: Rhythm detection and monitoring can be optimized with smart devices and telemedicine, while digital platforms such as social media and virtual reality offer new perspectives in the training of rhythmology specialists. CONCLUSION: Acquiring digital skills will be the basis for future work in rhythmology.

2.
J Arrhythm ; 39(3): 341-351, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37324756

ABSTRACT

Background: Cryoballoon ablation is a first-line therapy for atrial fibrillation. We compared the efficacy and safety of two ablation systems and addressed the influence of pulmonary vein (PV) anatomy on performance and outcome. Methods: We consecutively enrolled 122 patients who were planned for first-time cryoballoon ablation. Patients were assigned 1:1 for ablation with the POLARx or the Arctic Front Advance Pro (AFAP) system and followed-up for 12 months. Procedural parameters were recorded during the ablation. Before the procedure, a magnetic resonance angiography (MRA) of the PVs was generated and diameter, area, and shape of each PV ostium were assessed. We applied an evaluated PV anatomical scoring system on our MRA measurement data ranging from 0 (best anatomical combination) to 5. Results: Procedures performed with POLARx were associated with shorter time to balloon temperature -30°C (p < .001), lower balloon nadir temperature (p < .001), and longer thawing time till 0°C (p < .001) in all PVs, however, time to isolation was similar. We observed a decreasing performance with each increase in the score for the AFAP, whereas the POLARx performed constant regardless of the score. At 1 year, AF recurred in 14 of 44 patients treated with AFAP (31.8%) and in 10 of 45 patients treated with POLARx (22.2%) (hazard ratio, 0.61; 95% CI 0.28 to 1.37; p = .225). There was no significant correlation between PV anatomy and clinical outcome. Conclusion: We found significant differences in cooling kinetics, especially when anatomical conditions are difficult. However, both systems have a comparable outcome and safety profile.

3.
Front Cardiovasc Med ; 10: 1056134, 2023.
Article in English | MEDLINE | ID: mdl-36873400

ABSTRACT

Background: Atrial fibrosis represents a major hallmark in disease progression of atrial fibrillation (AF). We have previously shown that circulating microRNA-21 (miR-21) correlates with the extent of left atrial fibrosis in patients undergoing catheter ablation for AF and can serve as a biomarker to predict ablation success. In this study, we aimed to validate the role of miR-21-5p as a biomarker in a large cohort of AF patients and to investigate its pathophysiological role in atrial remodeling. Methods: For the validation cohort, we included 175 patients undergoing catheter ablation for AF. Bipolar voltage maps were obtained, circulating miR-21-5p was measured, and patients were followed-up for 12 months including ECG holter monitoring. AF was simulated by tachyarrhythmic pacing of cultured cardiomyocytes, the culture medium was transferred to fibroblast, and fibrosis pathways were analysed. Results: 73.3% of patients with no/minor LVAs, 51.4% of patients with moderate LVAs and only 18.2% of patients with extensive LVAs were in stable sinus rhythm (SR) 12 months after ablation (p < 0.01). Circulating miR-21-5p levels significantly correlated with the extent of LVAs and event-free survival. In-vitro tachyarrhythmic pacing of HL-1 cardiomyocytes resulted in an increased miR-21-5p expression. Transfer of the culture medium to fibroblasts induced fibrosis pathways and collagen production. The HDAC1 inhibitor mocetinostat was found to inhibit atrial fibrosis development. Conclusion: We validated miR-21-5p as a biomarker that reflects the extent of left atrial fibrosis in AF patients. Furthermore, we found that miR-21-5p is released in-vitro from cardiomyocytes under tachyarrhythmic conditions and stimulates fibroblasts in a paracrine mode to induce collagen production.

4.
J Clin Med ; 12(3)2023 Jan 28.
Article in English | MEDLINE | ID: mdl-36769640

ABSTRACT

A noninvasive tool for cardiovascular risk stratification has not yet been established in the clinical routine analysis. Previous studies suggest a prolonged Tpeak-Tend interval (the interval from the peak to the end of the T-wave) to be predictive of death. This meta-analysis was designed to systematically evaluate the association of the Tpeak-Tend interval with mortality outcomes. Medline (via PubMed), Embase and the Cochrane Library were searched from 1 January 2008 to 21 July 2020 for articles reporting the ascertainment of the Tpeak-Tend interval and observation of all-cause-mortality. The search yielded 1920 citations, of which 133 full-texts were retrieved and 29 observational studies involving 23,114 patients met the final criteria. All-cause deaths had longer Tpeak-Tend intervals compared to survivors by a standardized mean difference of 0.41 (95% CI 0.23-0.58) and patients with a long Tpeak-Tend interval had a higher risk of all-cause death compared to patients with a short Tpeak-Tend interval by an overall odds ratio of 2.33 (95% CI 1.57-3.45). Heart rate correction, electrocardiographic (ECG) measurement methods and the selection of ECG leads were major sources of heterogeneity. Subgroup analyses revealed that heart rate correction did not affect the association of the Tpeak-Tend interval with mortality outcomes, whereas this finding was not evident in all measurement methods. The Tpeak-Tend interval was found to be significantly associated with all-cause mortality. Further studies are warranted to confirm the prognostic value of the Tpeak-Tend interval.

5.
Front Physiol ; 13: 779826, 2022.
Article in English | MEDLINE | ID: mdl-35309059

ABSTRACT

Background: The standard 12-lead ECG has been shown to be of value in characterizing atrial conduction properties. The added value of extended ECG recordings (longer recordings from more sites) has not been systematically explored yet. Objective: The aim of this study is to employ an extended ECG to identify characteristics of atrial electrical activity related to paroxysmal vs. persistent atrial fibrillation (AF). Methods: In 247 participants scheduled for AF ablation, an extended ECG was recorded (12 standard plus 3 additional leads, 5 min recording, no filtering). For patients presenting in sinus rhythm (SR), the signal-averaged P-wave and the spatiotemporal P-wave variability was analyzed. For patients presenting in AF, f-wave properties in the QRST (the amplitude complex of the ventricular electrical activity: Q-, R-, S-, and T-wave)-canceled ECG were determined. Results: Significant differences between paroxysmal (N = 152) and persistent patients with AF (N = 95) were found in several P-wave and f-wave parameters, including parameters that can only be calculated from an extended ECG. Furthermore, a moderate, but significant correlation was found between echocardiographic parameters and P-wave and f-wave parameters. There was a moderate correlation of left atrial (LA) diameter with P-wave energy duration (r = 0.317, p < 0.001) and f-wave amplitude in lead A3 (r = -0.389, p = 0.002). The AF-type classification performance significantly improved when parameters calculated from the extended ECG were taken into account [area under the curve (AUC) = 0.58, interquartile range (IQR) 0.50-0.64 for standard ECG parameters only vs. AUC = 0.76, IQR 0.70-0.80 for extended ECG parameters, p < 0.001]. Conclusion: The P- and f-wave analysis of extended ECG configurations identified specific ECG features allowing improved classification of paroxysmal vs. persistent AF. The extended ECG significantly improved AF-type classification in our analyzed data as compared to a standard 10-s 12-lead ECG. Whether this can result in a better clinical AF type classification warrants further prospective study.

7.
Herzschrittmacherther Elektrophysiol ; 31(3): 246-253, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32785743

ABSTRACT

Atrial fibrillation (AF) is the most common arrhythmia and is highly associated with increased morbidity and mortality. Since many AF episodes remain subclinical, screening for AF is considered a desirable approach for timely diagnosis, prevention of sequelae and effective treatment. Recently, devices for AF detection-stand-alone or integrated in mobile health technology-have become available and show promising preliminary results in the detection and monitoring of arrhythmia. This review describes the technical aspects of a single-lead ECG stick and summarizes the current literature, experience in large-scale screening for AF in pharmacies and potential fields of application.


Subject(s)
Atrial Fibrillation , Electrocardiography , Humans , Mass Screening , Treatment Outcome
8.
Europace ; 22(9): 1337-1344, 2020 09 01.
Article in English | MEDLINE | ID: mdl-32725107

ABSTRACT

AIMS: Freedom from atrial fibrillation (AF) at 1 year can be achieved in 50-70% of patients undergoing catheter ablation. Recurrent AF early after ablation most commonly terminates spontaneously without further interventional treatment but is associated with later recurrent AF. The aim of this investigation is to identify clinical and procedural factors associated with recurrence of AF early after ablation. METHODS AND RESULTS: We retrospectively analysed data for recurrence of AF within the first 3 months after catheter ablation from the randomized controlled AXAFA-AFNET 5 trial, which demonstrated that continuous anticoagulation with apixaban is as safe and as effective compared to vitamin K antagonists in 678 patients undergoing first AF ablation. The primary outcome of first recurrent AF within 90 days was observed in 163 (28%) patients, in which 78 (48%) patients experienced an event within the first 14 days post-ablation. After multivariable adjustment, a history of stroke/transient ischaemic attack [hazard ratio (HR) 1.54, 95% confidence interval (CI) 0.93-2.6; P = 0.11], coronary artery disease (HR 1.85, 95% CI 1.20-2.86; P = 0.005), cardioversion during ablation (HR 1.78, 95% CI 1.26-2.49; P = 0.001), and an age:sex interaction for older women (HR 1.01, 95% CI 1.00-1.01; P = 0.04) were associated with recurrent AF. The P-wave duration at follow-up was significantly longer for patients with AF recurrence (129 ± 31 ms vs. 122 ± 22 ms in patients without AF, P = 0.03). CONCLUSION: Half of all early AF recurrences within the first 3 months post-ablation occurred within the first 14 days post-ablation. Vascular disease and cardioversion during the procedure are strong predictors of recurrent AF. P-wave duration at follow-up was longer in patients with recurrent AF. TRIAL REGISTRATION: Clinicaltrials.gov identifier NCT02227550.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Female , Humans , Recurrence , Retrospective Studies , Risk Factors , Treatment Outcome
9.
Sci Rep ; 10(1): 3577, 2020 02 27.
Article in English | MEDLINE | ID: mdl-32109235

ABSTRACT

Bioelectrical impedance spectroscopy (BIS) measures body composition, including fluid status. Acute decompensated heart failure (ADHF) is associated with fluid overload in different body compartments. This investigation aimed to evaluate the feasibility of measuring and monitoring fluid accumulation in patients with ADHF using BIS. The extracellular impedance as a surrogate marker for fluid accumulation was measured in 67 participants (25 healthy reference volunteers and 42 patients admitted with ADHF) using BIS in the "transthoracic", "foot-to-foot", "whole-body" and "hand-to-hand" segments. At baseline, BIS showed significantly lower extracellular resistance values for the "whole-body" (P < 0.001), "foot-to-foot" (P = 0.03), "hand-to-hand" (P < 0.001) and "transthoracic" (P = 0.014) segments in patients with ADHF than the reference cohort, revealing a specific pattern for peripheral, central and general fluid accumulation. The "foot-to-foot" (AUC = 0.8, P < 0.001) and "hand-to-hand" (AUC = 0.74, P = 0.04) segments indicated compartments of fluid accumulation with good prediction. During cardiac recompensation, BIS values changed significantly and were in line with routine parameters for monitoring ADHF. Mean bodyweight change per day correlated moderately to good with BIS values in the "whole-body" (r = -0.4), "foot-to-foot" (r = -0.8) and "transthoracic" (r = -0.4) segments. Based on our analysis, we conclude that measuring and monitoring fluid accumulation in ADHF using segmental BIS is feasible and correlates with clinical parameters during recompensation.


Subject(s)
Body Fluids/chemistry , Heart Failure/metabolism , Spectrum Analysis/methods , Aged , Aged, 80 and over , Body Fluids/metabolism , Cohort Studies , Electric Impedance , Female , Hospitalization , Humans , Male , Middle Aged
10.
J Electrocardiol ; 57: 31-34, 2019.
Article in English | MEDLINE | ID: mdl-31473477

ABSTRACT

BACKGROUND: Pacemaker induced Cardiomyopathy (PICM) is an easily overlooked cause of heart failure with reduced ejection fraction. Data regarding this complication are sparse. Therefore, the aim of this study was to identify the incidence and predictors of PICM. METHODS: Between 2011 and 2017, 857 consecutive patients undergoing pacemaker (PM) implantation, were reviewed, and according to our inclusion criteria 173 individuals were enrolled in this retrospective single center study. All patients included had normal left ventricular ejection fraction (LVEF) before implantation, underwent single-chamber ventricular or dual-chamber PM implantation, had RV pacing burden ≥20%, and repeated echocardiogram was available ≥1 year after implantation. PICM was defined as deterioration LVEF ≥10%, resulting in LVEF <50%, which cannot be explained by other causes. RESULTS: During a mean follow-up of 39.9 ±â€¯21.0 months, PICM occurred in 26 patients (16%). RV pacing percentage did not differ significantly between the both groups (76.5 vs 76.2%, p = 0.65). The PICM group patients were likely to be men (p = 0.002) and had a lower rate of arterial hypertension (p = 0.01). Multivariate analysis revealed male sex (HR 6.45, 0.95 CI 1.90-21.86, p = 0.003) and wider paced QRS complex (HR 1.04, 95% CI 1.02-1.07, p < 0.001) as predictors of PICM. CONCLUSIONS: In patients with frequent RV pacing, the prevalence of PICM is not uncommon. Male sex and wider paced QRS complex are independent predictors of PICM and these patients may require closer follow-up.


Subject(s)
Cardiomyopathies , Pacemaker, Artificial , Cardiac Pacing, Artificial , Cardiomyopathies/epidemiology , Electrocardiography , Humans , Incidence , Male , Pacemaker, Artificial/adverse effects , Retrospective Studies , Stroke Volume , Ventricular Function, Left
11.
Herzschrittmacherther Elektrophysiol ; 29(1): 57-61, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29313142

ABSTRACT

Atrial fibrillation (AF) is a common arrhythmia and is highly associated with stroke and cardiovascular morbidity. As many AF episodes remain subclinical (SCAF), large-scale AF screening is considered a desirable approach for the treatment and prevention of cardioembolic stroke. Newly available single-lead ECG devices have provided promising results in the diagnosis of SCAF and treatment by nonvitamin K antagonist drugs appears to be safe and effective. Nevertheless, a further gain in knowledge is needed to clarify the different types of AF. This may help to define how or if a patient should be treated in the context of outcome and cost effectiveness. This review summarizes the results of recent research in this field and focuses on single-lead, discontinuous single time-point, community-based comprehensive-screening-based AF management. We want to conclude that progress in ECG diagnosis and anticoagulation therapy has prepared the ground to establish large-scale AF screening. The remaining question, however, is which patients should be screened and what therapy should be initiated in case of AF.


Subject(s)
Electrocardiography/instrumentation , Mass Screening/organization & administration , Anticoagulants/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/prevention & control , Cross-Sectional Studies , Humans , Intracranial Embolism/prevention & control
12.
Sci Rep ; 7(1): 13175, 2017 10 13.
Article in English | MEDLINE | ID: mdl-29030566

ABSTRACT

Sleep disordered breathing (SDB) is known for fluctuating heart rates and an increased risk of developing arrhythmias. The current reference for heartbeat analysis is an electrocardiogram (ECG). As an unobtrusive alternative, we tested a sensor foil for mechanical vibrations to perform a ballistocardiography (BCG) and applied a novel algorithm for beat-to-beat cycle length detection. The aim of this study was to assess the correlation between beat-to-beat cycle length detection by the BCG algorithm and simultaneously recorded ECG. In 21 patients suspected for SDB undergoing polysomnography, we compared ECG to simultaneously recorded BCG data analysed by our algorithm. We analysed 362.040 heartbeats during a total of 93 hours of recording. The baseline beat-to-beat cycle length correlation between BCG and ECG was r s = 0.77 (n = 362040) with a mean absolute difference of 15 ± 162 ms (mean cycle length: ECG 923 ± 220 ms; BCG 908 ± 203 ms). After filtering artefacts and improving signal quality by our algorithm, the correlation increased to r s = 0.95 (n = 235367) with a mean absolute difference in cycle length of 4 ± 72 ms (ECG 920 ± 196 ms; BCG 916 ± 194 ms). We conclude that our algorithm, coupled with a BCG sensor foil provides good correlation of beat-to-beat cycle length detection with simultaneously recorded ECG.


Subject(s)
Sleep Apnea Syndromes/physiopathology , Adult , Algorithms , Ballistocardiography , Electrocardiography , Female , Heart Rate/physiology , Humans , Male , Middle Aged
14.
Europace ; 19(2): 319-328, 2017 02 01.
Article in English | MEDLINE | ID: mdl-28173083

ABSTRACT

Aims: Electromagnetic interferences (EMIs) with cardiovascular implantable electronic devices (CIEDs) are associated with potential risk for patients. Studies imply that CIED sensitivity setting and lead's tip-to-ring spacing determine the susceptibility of CIEDs with bipolar leads to electric and magnetic fields (EMFs); however, little is known about additional decisive parameters affecting EMI of CIEDs. We therefore investigated the influence of different patient-, device-, and lead-depending variables on EMIs in 160 patients. Methods and Results: We ran numerical simulations with human models to determine lead-depending variables on the risk of EMI by calculating the voltage induced in bipolar leads from 50/60 Hz EMF. We then used the simulation results and analysed 26 different patient-, device-, and lead-depending variables with respect to the EMI threshold of 160 CIED patients. Our analyses revealed that a horizontal orientation and a medial position of the bipolar lead's distal end (lead-tip) are most beneficial for CIED patients to reduce the risk of EMI. In addition, the effect of CIED sensitivity setting and lead's tip-to-ring spacing was confirmed. Conclusion: Our data suggest that in addition to the established influencing factors, a medial position of the lead-tip for the right ventricular lead as achievable at the interventricular septum and a horizontal orientation of the lead-tip can reduce the risk of EMI. In the right atrium, a horizontal orientation of the lead-tip should generally be striven independent of the chosen position. Still important to consider remains a good intrinsic sensing amplitude during implant procedure.


Subject(s)
Cardiac Resynchronization Therapy Devices , Defibrillators, Implantable , Electrodes, Implanted , Electromagnetic Fields , Adult , Aged , Female , Humans , Male , Middle Aged , Proportional Hazards Models , Young Adult
15.
Biomed Res Int ; 2015: 840356, 2015.
Article in English | MEDLINE | ID: mdl-26229965

ABSTRACT

BACKGROUND: Heart rate monitoring is especially interesting in patients with atrial fibrillation (AF) and is routinely performed by ECG. A ballistocardiography (BCG) foil is an unobtrusive sensor for mechanical vibrations. We tested the correlation of heartbeat cycle length detection by a novel algorithm for a BCG foil to an ECG in AF and sinus rhythm (SR). METHODS: In 22 patients we obtained BCG and synchronized ECG recordings before and after cardioversion and examined the correlation between heartbeat characteristics. RESULTS: We analyzed a total of 4317 heartbeats during AF and 2445 during SR with a correlation between ECG and BCG during AF of r = 0.70 (95% CI 0.68-0.71, P < 0.0001) and r = 0.75 (95% CI 0.73-0.77, P < 0.0001) during SR. By adding a quality index, artifacts could be reduced and the correlation increased for AF to 0.76 (95% CI 0.74-0.77, P < 0.0001, n = 3468) and for SR to 0.85 (95% CI 0.83-0.86, P < 0.0001, n = 2176). CONCLUSION: Heartbeat cycle length measurement by our novel algorithm for BCG foil is feasible during SR and AF, offering new possibilities of unobtrusive heart rate monitoring. This trial is registered with IRB registration number EK205/11. This trial is registered with clinical trials registration number NCT01779674.


Subject(s)
Algorithms , Atrial Fibrillation/physiopathology , Ballistocardiography/methods , Heart Rate , Aged , Atrial Fibrillation/therapy , Electric Countershock , Electrocardiography , Female , Humans , Male
16.
Biomed Res Int ; 2015: 810797, 2015.
Article in English | MEDLINE | ID: mdl-25861647

ABSTRACT

BACKGROUND: Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. METHODS: 45 participants (21 with pleural effusion and 24 healthy subjects) were included. Bioelectrical impedance was analyzed for "Transthoracic," "Foot to Foot," "Foot to Hand," and "Hand to Hand" vectors in low and high frequency domain before and after thoracentesis. Healthy subjects were measured at a single time point. RESULTS: The mean volume of removed pleural effusion was 1169 ± 513 mL. The "Foot to Foot," "Hand to Hand," and "Foot to Hand" vector indicated a trend for increased bioelectrical impedance after thoracentesis. Values for the low frequency domain in the "Transthoracic" vector increased significantly (P < 0.001). A moderate correlation was observed between the amount of removed fluid and impedance change in the low frequency domain using the "Foot to Hand" vector (r = -0.7). CONCLUSION: Bioelectrical impedance changes in correlation with the thoracic fluid level. It was feasible to monitor significant fluid shifts and loss after thoracentesis in the "Transthoracic" vector by means of bioelectrical impedance spectroscopy. The trial is registered with Registration Numbers IRB EK206/11 and NCT01778270.


Subject(s)
Body Composition/physiology , Body Fluids/physiology , Foot/physiology , Hand/physiology , Pleural Effusion/physiopathology , Adult , Aged , Case-Control Studies , Electric Impedance , Female , Humans , Male , Spectrum Analysis/methods , Thoracentesis/methods
17.
Physiol Meas ; 35(6): 917-30, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24846392

ABSTRACT

Episodes of hospitalization for heart failure patients are frequent and are often accompanied by fluid accumulations. The change of the body impedance, measured by bioimpendace spectroscopy, is an indicator of the water content. The hypothesis was that it is possible to detect edema from the impedance data. First, a finite integration technique was applied to test the feasibility and allowed a theoretical analysis of current flows through the body. Based on the results of the simulations, a clinical study was designed and conducted. The segmental impedances of 25 patients suffering from heart failure were monitored over their recompensation process. The mean age of the patients was 73.8 and their mean body mass index was 28.6. From these raw data the model parameters from the Cole model were deduced by an automatic fitting algorithm. These model data were used to classify the edema status of the patient. The baseline values of the regression lines of the extra- and intracellular resistance from the transthoracic measurement and the baseline value of the regression line of the extracellular resistance from the foot-to-foot measurement were identified as important parameters for the detection of peripheral edema. The rate of change of the imaginary impedance at the characteristic frequency and the mean intracellular resistance from the foot-to-foot measurement were identified as important parameters for the detection of pulmonary edema. To classify the data, two decision trees were considered: One should detect pulmonary edema (n(pulmonary) = 13, n(none) = 12) and the other peripheral edema (n(peripheral) = 12, n(none) = 13). Peripheral edema could be detected with a sensitivity of 100% and a specificity of 90%. The detection of pulmonary edema showed a sensitivity of 92.31% and a specificity of 100%. The leave-one-out cross-validation-error for the peripheral edema detection was 12% and 8% for the detection of pulmonary edema. This enables the application of BIS as an early warning system for cardiac decompensation with the potential to optimize patient care.


Subject(s)
Body Fluids/metabolism , Dielectric Spectroscopy/methods , Heart Failure/physiopathology , Aged , Body Weight , Computer Simulation , Decision Trees , Electric Impedance , Electrodes , Female , Humans , Male , Natriuretic Peptide, Brain/metabolism , Peptide Fragments/metabolism , Pulmonary Edema/diagnosis