Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 28(Pt 6): 1811-1819, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34738934

ABSTRACT

X-ray absorption fine-structure (XAFS) spectroscopy can assess the chemical speciation of the elements providing their coordination and oxidation state, information generally hidden to other techniques. In the case of trace elements, achieving a good quality XAFS signal poses several challenges, as it requires high photon flux, counting statistics and detector linearity. Here, a new multi-element X-ray fluorescence detector is presented, specifically designed to probe the chemical speciation of trace 3d elements down to the p.p.m. range. The potentialities of the detector are presented through a case study: the speciation of ultra-diluted elements (Fe, Mn and Cr) in geological rocks from a calcareous formation related to the dispersal processes from Ontong (Java) volcanism (mid-Cretaceous). Trace-elements speciation is crucial in evaluating the impact of geogenic and anthropogenic harmful metals on the environment, and to evaluate the risks to human health and ecosystems. These results show that the new detector is suitable for collecting spectra of 3d elements in trace amounts in a calcareous matrix. The data quality is high enough that quantitative data analysis could be performed to determine their chemical speciation.


Subject(s)
Trace Elements , Ecosystem , Exercise Test , Humans , Metals , Trace Elements/analysis , X-Ray Absorption Spectroscopy
2.
Sensors (Basel) ; 19(2)2019 Jan 14.
Article in English | MEDLINE | ID: mdl-30646553

ABSTRACT

Different applications require different customizations of silicon photomultiplier (SiPM) technology. We present a review on the latest SiPM technologies developed at Fondazione Bruno Kessler (FBK, Trento), characterized by a peak detection efficiency in the near-UV and customized according to the needs of different applications. Original near-UV sensitive, high-density SiPMs (NUV-HD), optimized for Positron Emission Tomography (PET) application, feature peak photon detection efficiency (PDE) of 63% at 420 nm with a 35 um cell size and a dark count rate (DCR) of 100 kHz/mm². Correlated noise probability is around 25% at a PDE of 50% at 420 nm. It provides a coincidence resolving time (CRT) of 100 ps FWHM (full width at half maximum) in the detection of 511 keV photons, when used for the readout of LYSO(Ce) scintillator (Cerium-doped lutetium-yttrium oxyorthosilicate) and down to 75 ps FWHM with LSO(Ce:Ca) scintillator (Cerium and Calcium-doped lutetium oxyorthosilicate). Starting from this technology, we developed three variants, optimized according to different sets of specifications. NUV-HD⁻LowCT features a 60% reduction of direct crosstalk probability, for applications such as Cherenkov telescope array (CTA). NUV-HD⁻Cryo was optimized for cryogenic operation and for large photosensitive areas. The reference application, in this case, is the readout of liquid, noble-gases scintillators, such as liquid Argon. Measurements at 77 K showed a remarkably low value of the DCR of a few mHz/mm². Finally, vacuum-UV (VUV)-HD features an increased sensitivity to VUV light, aiming at direct detection of photons below 200 nm. PDE in excess of 20% at 175 nm was measured in liquid Xenon. In the paper, we discuss the specifications on the SiPM related to different types of applications, the SiPM design challenges and process optimizations, and the results from the experimental characterization of the different, NUV-sensitive technologies developed at FBK.

4.
Phys Med Biol ; 59(13): 3615-35, 2014 Jul 07.
Article in English | MEDLINE | ID: mdl-24922188

ABSTRACT

For a given photon detection efficiency (PDE), the primary, Poisson distributed, dark count rate of the detector (DCR0) is one of the most limiting factors affecting the timing resolution of a silicon photomultiplier (SiPM) in the scintillation light readout. If the effects of DCR0 are removed through a suitable baseline compensation algorithm or by cooling, it is possible to clearly observe another phenomenon that limits the PDE, and thus the timing resolution of the detector. It is caused by the optical crosstalk of the SiPM, which is significantly increased by the presence of the scintillator. In this paper, we describe this phenomenon, which is also easily observed from the reverse I-V curve of the device, and we relate it to the measured coincidence resolving time in 511 keV γ-ray measurements. We discuss its consequences on the SiPM design and, in particular, we observe that there is an optimal cell size, dependent on both SiPM and crystal parameters, that maximizes the PDE in presence of optical crosstalk. Finally, we report on a crosstalk simulator developed to study the phenomenon and we compare the simulation results obtained for different SiPM technologies, featuring different approaches to the reduction of the crosstalk.


Subject(s)
Luminescence , Optical Phenomena , Positron-Emission Tomography/instrumentation , Silicon , Time Factors
5.
Phys Med Biol ; 59(4): 869-80, 2014 Feb 21.
Article in English | MEDLINE | ID: mdl-24487651

ABSTRACT

This paper presents the performance, in terms of energy and timing resolution, of high-density silicon photomultipliers (SiPMs) produced at Fondazione Bruno Kessler for time-of-flight positron emission tomography application. The new SiPM technology allows us to produce devices with a small cell size maintaining a high fill factor (FF). The sensors considered in this paper are composed by 30 × 30 µm(2) cells with a FF exceeding 70% to cover a total area of 4 × 4 mm(2). The SiPM performance was evaluated using two types of scintillators (Ce:LYSO and Ce:GaGG) both with a short height (5 mm) in order to minimize the time jitter caused by light propagation in the crystal. With Ce:LYSO, an energy resolution of 9.0% FWHM at 511 keV and a coincidence resolving time (CRT) of 125 ps FWHM were obtained at -20 °C. With Ce:GaGG, an energy resolution of 6.4% FWHM and a CRT of 260 ps FWHM were achieved at the same temperature. The novel SiPM technology, combining a high PDE with a low correlated noise (i.e., crosstalk and afterpulse), allows us to improve the state-of-the-art of energy and timing resolution with both the tested crystals.


Subject(s)
Positron-Emission Tomography/methods , Scintillation Counting/methods , Silicon , Light , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...