Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Front Oncol ; 13: 1270498, 2023.
Article in English | MEDLINE | ID: mdl-38023175

ABSTRACT

Simple summary: Stereotactic body radiotherapy (SBRT) of 35-36.25 Gy in five fractions with the CyberKnife System yields excellent control with low toxicity in low-intermediate-risk prostate cancer patients. We found no differences in biochemical control and overall survival in relation to dose. There were no significant differences in toxicity or quality of life between the two groups. Aims: Stereotactic body radiotherapy (SBRT) is an emerging therapeutic approach for low- and intermediate-risk prostate cancer. We present retrospective data on biochemical control, toxicity, and quality of life of CyPro Trial. Materials and methods: A total of 122 patients with low- and intermediate-risk prostate cancer were treated with the CyberKnife System at a dose of 35 Gy or 36.25 Gy in five fractions. Biochemical failure (BF)/biochemical disease-free survival (bDFS) was defined using the Phoenix method (nadir + 2 ng/ml). Acute/late rectal and urinary toxicities were assessed by the Radiation Therapy Oncology Group (RTOG) toxicity scale. Quality of life (QoL) was assessed by the European Organisation for Research and Treatment of Cancer (EORTC) QLQ C30 and PR25. International Erectile Function Index-5 (IIEF5) and International Prostate Symptom Score (IPSS) questionnaires were administered at baseline, every 3 months after treatment during the first years, and then at 24 months and 36 months. Results: The 1-, 2-, and 5-year DFS rates were 92.9%, 92.9%, and 92.3%, respectively, while the 1-, 2-, and 5-year bDFS rates were 100%, 100%, and 95.7%, respectively. With regard to risk groups or doses, no statistically significant differences were found in terms of DFS or bDFS. Grade 2 urinary toxicity was acute in 10% and delayed in 2% of patients. No Grade 3 acute and late urinary toxicity was observed. Grade 2 rectal toxicity was acute in 8% and late in 1% of patients. No Grade 3-4 acute and late rectal toxicity was observed. Grade 2 acute toxicity appeared higher in the high-dose group (20% in the 36.25-Gy group versus 3% in the 35-Gy group) but was not statistically significant. Conclusion: Our study confirms that SBRT of 35-36.25 Gy in five fractions with the CyberKnife System produces excellent control with low toxicity in patients with low-intermediate-risk prostate cancer. We found no dose-related differences in biochemical control and overall survival. Further confirmation of these results is awaited through the prospective phase of this study, which is still ongoing.

2.
Cancers (Basel) ; 14(13)2022 Jun 29.
Article in English | MEDLINE | ID: mdl-35804958

ABSTRACT

The management of prostate cancer recurrence following external beam radiotherapy is not defined yet. Stereotaxic body reirradiation therapy showed encouraging results for local and biochemical control. From April 2017 to December 2020, 29 patients with prostate cancer recurrence were collected, joining the retrospective studies CyPro (prot. 46/19 OSS) and CLARO (Prot. 19/20 OSS) trials. Patients received Cyberknife® treatment (17 pts) or alternatively VMAT (Volumetric Modulated Arc Technique) therapy by IGRT (Image-Guided Radiation Therapy)/Clarity® (12 pts). By comparing the reirradiation of two groups, urinary (GU), rectal (GI) toxicities, and biochemical control were investigated. Further, the two techniques were dosimetrically compared by rival plans. The VMAT-IGRT Clarity® treatments were replanned with an optimized template developed for prostate VMAT-SBRT in FFF mode keeping the same dose and fractionation scheduled for Cyberknife Group (30 Gy in 5 fx, at 80% isodose). In the CK group, 23% of patients experienced grade 2 acute GU, while 6% grade 2 acute GI. In the VMAT-Clarity® group, acute GU toxicity was recorded in 17%, while for 8% grade 2 late toxicity was recorded. The dosimetric analysis shows that the VMAT-FFF allows to deliver a biological equivalent dose to CK, with the advantage of reducing the likelihood of toxicities arising.

3.
Life (Basel) ; 12(5)2022 May 10.
Article in English | MEDLINE | ID: mdl-35629378

ABSTRACT

In recent years, stereotactic body radiation therapy (SBRT) has gained popularity among clinical methods for the treatment of medium and low risk prostate cancer (PCa), mainly as an alternative to surgery. The hypo-fractionated regimen allows the administration of high doses of radiation in a small number of fractions; such a fractionation is possible by exploiting the different intrinsic prostate radiosensitivity compared with the surrounding healthy tissues. In addition, SBRT treatment guaranteed a better quality of life compared with surgery, avoiding risks, aftermaths, and possible complications. At present, most stereotactic prostate treatments are performed with the CyberKnife (CK) system, which is an accelerator exclusively dedicated for stereotaxis and it is not widely spread in every radiotherapy centre like a classic linear accelerator (LINAC). To be fair, a stereotactic treatment is achievable also by using a LINAC through Volumetric Modulated Arc Therapy (VMAT), but some precautions must be taken. The aim of this work is to carry out a dosimetric comparison between these two methodologies. In order to pursue such a goal, two groups of patients were selected at Instituto Nazionale Tumori-IRCCS Fondazione G. Pascale: the first group consisting of ten patients previously treated with a SBRT performed with CK; the second one was composed of ten patients who received a hypo-fractionated VMAT treatment and replanned in VMAT-SBRT flattening filter free mode (FFF). The two SBRT techniques were rescaled at the same target coverage and compared by normal tissue sparing, dose distribution parameters and delivery time. All organs at risk (OAR) constraints were achieved by both platforms. CK exhibits higher performances in terms of dose delivery; nevertheless, the general satisfying dosimetric results and the significantly shorter delivery time make VMAT-FFF an attractive and reasonable alternative SBRT technique for the treatment of localized prostate cancer.

4.
Phys Med ; 32(1): 277-83, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26498378

ABSTRACT

PURPOSE: To compare five liver metastasis stereotactic ablative radiotherapy (SABR) plans optimised in fourteen centres with 3D-Conformal-RT, IMRT, VMAT, CyberKnife and Tomotherapy and identify possible dosimetric differences. METHODS: Dose prescription was 75 Gy in 3 fractions, normalised at 67%-95% isodose. RESULTS: Excluding few cases, all institutions achieved the planning objectives. Differences up to 40% and 25% in mean dose to liver and PTV were found. No significant correlations between technological factors and DVH for target and OARs were observed; the optimisation strategies selected by the planners played a key role in the planning procedure. CONCLUSIONS: The human factor and the constraints imposed to the target volume have a greater dosimetric impact than treatment planning and radiation delivery technology in stereotactic treatment of liver metastases. Significant differences found both in terms of dosimetric target coverage and OAR sparing should be taken into consideration before starting a multi-institutional SARB clinical trial.


Subject(s)
Liver Neoplasms/radiotherapy , Liver Neoplasms/surgery , Radiosurgery/methods , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods , Computer Simulation , Databases, Factual , Four-Dimensional Computed Tomography/methods , Humans , Italy , Neoplasm Metastasis , Organs at Risk , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Reproducibility of Results , Treatment Outcome
5.
Free Radic Biol Med ; 46(1): 110-6, 2009 Jan 01.
Article in English | MEDLINE | ID: mdl-18996183

ABSTRACT

Organisms exposed to ionizing radiation are mainly damaged by free radicals, which are generated by the radiolysis of water contained in the cells. Recently a significant reduction of tissue injury from irradiation damage was demonstrated by using MnSOD-plasmid/liposome treatments in the protection of murine lung. In this study we show that a new active recombinant human MnSOD (rMnSOD), easily administered in vivo, not only exerts the same radioprotective effect on normal cells and organisms as any MnSOD, but it is also radiosensitizing for tumor cells. In addition, we show how healthy animals, exposed to lethal doses of ionizing radiation and daily injections with rMnSOD, were protected from radiodamage and were still alive 30 days after the irradiation, while animals treated with only PBS solution, in the absence of rMnSOD, died after 7-8 days from the radiotreatments. The molecular analysis of all irradiated tissues revealed that the antiapoptotic AVEN gene appeared activated only in the animals treated in the presence of rMnSOD. The data suggest that rMnSOD deserves to be considered as a pharmaceutical tool for making radiotherapy more selective on cancer cells and to prevent and/or cure the accidental damage derived from exposure to ionizing radiation.


Subject(s)
Adaptor Proteins, Signal Transducing/biosynthesis , Apoptosis Regulatory Proteins/metabolism , Fibroblasts/drug effects , Free Radical Scavengers/administration & dosage , Membrane Proteins/biosynthesis , Recombinant Proteins/administration & dosage , Superoxide Dismutase/administration & dosage , Animals , Apoptosis/drug effects , Apoptosis/radiation effects , Apoptosis Regulatory Proteins/biosynthesis , Apoptosis Regulatory Proteins/genetics , Apoptosis Regulatory Proteins/radiation effects , Cell Line, Tumor , Female , Fibroblasts/pathology , Fibroblasts/radiation effects , Free Radical Scavengers/pharmacology , Free Radicals/toxicity , Gene Expression/drug effects , Gene Expression/radiation effects , Humans , Lethal Dose 50 , Mice , Mice, Inbred C57BL , Neoplasms/drug therapy , Neoplasms/radiotherapy , Radiation Injuries/prevention & control , Radiation Tolerance/drug effects , Radiation, Ionizing , Radiation-Sensitizing Agents/therapeutic use , Recombinant Proteins/pharmacology , Superoxide Dismutase/pharmacology
6.
Int J Radiat Oncol Biol Phys ; 57(3): 732-8, 2003 Nov 01.
Article in English | MEDLINE | ID: mdl-14529778

ABSTRACT

PURPOSE: To measure chromosomal aberrations in blood lymphocytes from breast cancer patients treated with radiotherapy after quadrantectomy or tumorectomy. METHODS AND MATERIALS: Twenty-two breast cancer patients treated with breast-conserving surgery and radiation were evaluated. Adjuvant chemotherapy was also given to 9 patients. Blood samples were obtained before radiotherapy, after about one-half of the fractions, and at the end of the treatment of the whole breast (50 Gy). Chromosome aberrations in peripheral blood lymphocytes were measured using chemical-induced premature chromosome condensation combined with fluorescence in situ hybridization. RESULTS: Radiation treatment produced a significant increase in the yield of chromosomal aberrations. A large interindividual variability was observed. The variability was not related to field size, previous chemotherapy, or treatment morbidity. Chromosome aberrations in lymphocytes at the end of the treatment were significantly higher in the group of patients with no lymph nodes surgically removed before the treatment than in the group of patients with more than 10 lymph nodes removed. CONCLUSION: The number of lymph nodes within the radiation field is an important factor affecting the yield of radiation-induced chromosomal aberrations in breast cancer patients.


Subject(s)
Breast Neoplasms/radiotherapy , Chromosome Aberrations , Lymph Nodes/radiation effects , Lymphocytes/radiation effects , Antineoplastic Combined Chemotherapy Protocols/administration & dosage , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Breast Neoplasms/drug therapy , Breast Neoplasms/genetics , Breast Neoplasms/surgery , Chemotherapy, Adjuvant , Cisplatin/administration & dosage , Female , Fluorouracil/administration & dosage , Humans , Lymph Node Excision , Mastectomy, Segmental , Methotrexate/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL