Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Viruses ; 16(7)2024 Jun 25.
Article in English | MEDLINE | ID: mdl-39066185

ABSTRACT

Pulmonary function examinations are critical to assess respiratory disease severity in patients. In preclinical rodent models of viral respiratory infections, however, disease is frequently evaluated based on virological, pathological and/or surrogate clinical parameters, which are not directly associated with lung function. To bridge the gap between preclinical and clinical readouts, we aimed to apply unrestrained whole-body plethysmography (WBP) measurements in a SARS-CoV-2 Syrian hamster challenge model. While WBP measurements are frequently used for preclinical research in mice and rats, results from studies in hamsters are still limited. During unrestrained WBP measurements, we obtained highly variable breathing frequency values outside of the normal physiological range for hamsters. Importantly, we observed that animal movements were recorded as breaths during WBP measurements. By limiting animal movement through either mechanical or chemical restraint, we improved the reliability of the lung function readout and obtained breathing frequencies that correlated with clinical signs when comparing two different variants of SARS-CoV-2 post-inoculation. Simultaneously, however, new sources of experimental variation were introduced by the method of restraint, which demands further optimalization of WBP measurements in Syrian hamsters. We concluded that WBP measurements are a valuable refinement either in combination with video recordings or if average values of measurements lasting several hours are analyzed.


Subject(s)
COVID-19 , Disease Models, Animal , Lung , Mesocricetus , SARS-CoV-2 , Animals , COVID-19/virology , COVID-19/diagnosis , COVID-19/physiopathology , Lung/virology , Lung/physiopathology , Cricetinae , Plethysmography, Whole Body/methods , Respiratory Function Tests/methods , Male , Female , Reproducibility of Results
2.
Animals (Basel) ; 14(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38998020

ABSTRACT

Sensor technologies are increasingly used to monitor laboratory animal behaviour. The aim of this study was to investigate the added value of using accelerometers and video to monitor the activity and drinking behaviour of three rams from 5 days before to 22 days after inoculation with Toxoplasma gondii. We computed the activity from accelerometer data as the vectorial dynamic body acceleration (VDBA). In addition, we assessed individual drinking behaviour from video, using frame differencing above the drinker to identify drinking bouts, and Aruco markers for individual identification. Four days after inoculation, rams developed fever and activity decreased. The daytime VDBA from days 4 to 10 was 60-80% of that before inoculation. Animal caretakers scored rams as lethargic on days 5 and 6 and, for one ram, also on the morning of day 7. Video analysis showed that each ram decreased its number of visits to the drinker, as well as its time spent at the drinker, by up to 50%. The fever and corresponding sickness behaviours lasted until day 10. Overall, while we recognize the limited conclusiveness due to the small number of animals, the sensor technologies provided continuous, individual, detailed, and objective data and offered additional insights as compared to routine observations. We recommend the wider implementation of such technologies in animal disease trials to refine experiments and guarantee the quality of experimental results.

SELECTION OF CITATIONS
SEARCH DETAIL