Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
Phys Med Biol ; 69(4)2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38232395

ABSTRACT

Objective. The bowel is an important organ at risk for toxicity during pelvic and abdominal radiotherapy. Identifying regions of high and low bowel motion with MRI during radiotherapy may help to understand the development of bowel toxicity, but the acquisition time of MRI is rather long. The aim of this study is to retrospectively evaluate the precision of bowel motion quantification and to estimate the minimum MRI acquisition time.Approach. We included 22 gynaecologic cancer patients receiving definitive radiotherapy with curative intent. The 10 min pre-treatment 3D cine-MRI scan consisted of 160 dynamics with an acquisition time of 3.7 s per volume. Deformable registration of consecutive images generated 159 deformation vector fields (DVFs). We defined two motion metrics, the 50th percentile vector lengths (VL50) of the complete set of DVFs was used to measure median bowel motion. The 95th percentile vector lengths (VL95) was used to quantify high motion of the bowel. The precision of these metrics was assessed by calculating their variation (interquartile range) in three different time frames, defined as subsets of 40, 80, and 120 consecutive images, corresponding to acquisition times of 2.5, 5.0, and 7.5 min, respectively.Main results. For the full 10 min scan, the minimum motion per frame of 50% of the bowel volume (M50%) ranged from 0.6-3.5 mm for the VL50 motion metric and 2.3-9.0 mm for the VL95 motion metric, across all patients. At 7.5 min scan time, the variation in M50% was less than 0.5 mm in 100% (VL50) and 95% (VL95) of the subsets. A scan time of 5.0 and 2.5 min achieved a variation within 0.5 mm in 95.2%/81% and 85.7%/57.1% of the subsets, respectively.Significance. Our 3D cine-MRI technique quantifies bowel loop motion with 95%-100% confidence with a precision of 0.5 mm variation or less, using a 7.5 min scan time.


Subject(s)
Magnetic Resonance Imaging, Cine , Radiotherapy, Image-Guided , Humans , Retrospective Studies , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging/methods , Motion , Radiotherapy, Image-Guided/methods
2.
Eur Radiol Exp ; 5(1): 8, 2021 02 10.
Article in English | MEDLINE | ID: mdl-33565002

ABSTRACT

BACKGROUND: Colonic manometry is the current reference standard for assessing colonic neuromuscular function in children with intractable functional constipation (FC). Recently, cine magnetic resonance imaging (cine-MRI) has been proposed as a non-invasive alternative. We compared colonic motility patterns on cine-MRI with those obtained by manometry in children, by stimulating high-amplitude propagating contractions (HAPCs) with bisacodyl under manometric control while simultaneously acquiring cine-MRI. METHODS: After Institutional Review Board approval, adolescents with FC scheduled to undergo colonic manometry were included. A water-perfused 8-lumen catheter was used for colonic manometry recordings. After an intraluminal bisacodyl infusion, cine-MRI sequences of the descending colon were acquired for about 30 min simultaneously with colonic manometry. Manometry recordings were analysed for HAPCs. MRI images were processed with spatiotemporal motility MRI techniques. The anonymised motility results of both techniques were visually compared for the identification of HAPCs in the descending colon. RESULTS: Data regarding six patients (three males) were analysed (median age 14 years, range 12-17). After bisacodyl infusion, three patients showed a total of eleven HAPCs with colonic manometry. Corresponding cine-MRI recorded high colonic activity during two of these HAPCs, minimal activity during seven HAPCs, while two HAPCs were not recorded. In two of three patients with absent HAPCs on manometry, colonic activity was recorded with cine-MRI. CONCLUSIONS: Simultaneous acquisition of colonic cine-MRI and manometry in children with FC is feasible. Their motility results did not completely overlap in the identification of HAPCs. Research is needed to unravel the role of cine-MRI in this setting.


Subject(s)
Gastrointestinal Motility , Magnetic Resonance Imaging, Cine , Adolescent , Child , Colon/diagnostic imaging , Constipation/diagnostic imaging , Feasibility Studies , Humans , Male , Manometry
3.
Eur Radiol Exp ; 3(1): 7, 2019 Feb 06.
Article in English | MEDLINE | ID: mdl-30725241

ABSTRACT

BACKGROUND: To investigate the feasibility of compressed sensing and parallel imaging (CS-PI)-accelerated bowel motility magnetic resonance imaging (MRI) and to compare its image quality and diagnostic quality to conventional sensitivity encoding (SENSE) accelerated scans. METHODS: Bowel MRI was performed in six volunteers using a three-dimensional balanced fast field-echo sequence. Static scans were performed after the administration of a spasmolytic agent to prevent bowel motion artefacts. Fully sampled reference scans and multiple prospectively 3× to 7× undersampled CS-PI and SENSE scans were acquired. Additionally, fully sampled CS-PI and SENSE scans were retrospectively undersampled and reconstructed. Dynamic scans were performed using 5× to 7× accelerated scans in the presence of bowel motion. Retrospectively, undersampled scans were compared to fully sampled scans using structural similarity indices. All reconstructions were visually assessed for image quality and diagnostic quality by two radiologists. RESULTS: For static imaging, the performance of CS-PI was lower than that of fully sampled and SENSE scans: the diagnostic quality was assessed as adequate or good for 100% of fully sampled scans, 95% of SENSE, but only for 55% of CS-PI scans. For dynamic imaging, CS-PI image quality was scored similar to SENSE at high acceleration. Diagnostic quality of all scans was scored as adequate or good; 55% of CS-PI and 83% of SENSE scans were scored as good. CONCLUSION: Compared to SENSE, current implementation of CS-PI performed less or equally good in terms of image quality and diagnostic quality. CS-PI did not show advantages over SENSE for three-dimensional bowel motility imaging.

4.
Article in English | MEDLINE | ID: mdl-29265641

ABSTRACT

Dynamic magnetic resonance imaging (MRI) of gastrointestinal motility has developed rapidly over the past few years. The non-invasive and non-ionizing character of MRI is an important advantage together with the fact that it is fast and can visualize the entire gastrointestinal tract. Advances in imaging and quantification techniques have facilitated assessment of gastric, small intestinal, and colonic motility in a clinical setting. Automated quantitative motility assessment using dynamic MRI meets the need for non-invasive techniques. Recently, studies have begun to examine this technique in patients, including those with IBD, pseudo-obstruction and functional bowel disorders. Remaining challenges for clinical implementation are processing the large amount of data, standardization and validation of the numerous MRI metrics and subsequently assessment of the potential role of dynamic MRI. This review examines the methods, advances, and remaining challenges of evaluation of gastrointestinal motility with MRI. It accompanies an article by Khalaf et al. in this journal that describes a new protocol for assessment of pan-intestinal motility in fasted and fed state in a single MRI session.


Subject(s)
Gastrointestinal Diseases/diagnostic imaging , Gastrointestinal Motility , Gastrointestinal Tract/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Crohn Disease/diagnostic imaging , Humans , Intestinal Pseudo-Obstruction/diagnostic imaging , Irritable Bowel Syndrome/diagnostic imaging , Magnetic Resonance Imaging, Cine/trends
5.
Skin Res Technol ; 21(3): 340-5, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25534374

ABSTRACT

BACKGROUND: Vascular modifications represent a key feature in psoriatic plaques. Previous research with Laser Doppler Perfusion Imaging (LDPI) revealed a remarkable heterogeneity in the cutaneous perfusion within homogenous-appearing psoriatic lesions. Insights in the relation between perfusion during treatment and related biological changes are lacking. OBJECTIVES: To study the effect of calcipotriol-betamethasone dipropionate ointment on the microcirculation and the expression levels of immunohistochemical markers in psoriatic lesions compared to the distant uninvolved skin. METHODS: Psoriatic lesions of fourteen patients were treated once a day during 8 weeks. Clinical SUM scores and the perfusion intensity by means of LDPI were assessed every 2 weeks. After 8 weeks, a biopsy from the target lesion and one from the distant uninvolved skin were taken and stained for psoriasis-related markers, like IL-17 and CD31. RESULTS: After 8 weeks, seven patients reached a SUM score of 0 or 1, and were classified as good-responders. The other patients were classified moderate-responders. The perfusion intensity decreased in all lesions during therapy. In the good-responders, all investigated psoriasis-related proteins within the treated lesions reached the expression level found within the distant uninvolved skin. The expression of CD31, however, was significantly higher in the treated lesions as compared to the distant uninvolved skin (p = 0.0156). In the moderate responders, almost all expression levels remained significantly elevated compared to the uninvolved skin. CONCLUSIONS: In the skin of good-responders the expression of dermal CD31(+) endothelium remains significantly elevated within the treated lesions compared with the distant uninvolved skin, whereas a marked reduction in the perfusion intensity and SUM score was found. This indicates that clinical improvement might outrun endothelial changes.


Subject(s)
Blood Flow Velocity , Laser-Doppler Flowmetry/methods , NK Cell Lectin-Like Receptor Subfamily K/immunology , Psoriasis/drug therapy , Psoriasis/physiopathology , Skin/physiopathology , Administration, Topical , Adult , Aged , Betamethasone/administration & dosage , Biomarkers , Calcitriol/administration & dosage , Calcitriol/analogs & derivatives , Cytokines/immunology , Dermatologic Agents/administration & dosage , Drug Combinations , Female , Humans , Male , Middle Aged , Ointments/administration & dosage , Perfusion Imaging/methods , Psoriasis/diagnosis , Reproducibility of Results , Sensitivity and Specificity , Skin/drug effects , Up-Regulation/immunology
SELECTION OF CITATIONS
SEARCH DETAIL