ABSTRACT
IMPORTANCE: Animal and observational human studies report that delivery of excessive tidal volume (VT) at birth is associated with lung and brain injury. Using a respiratory function monitor (RFM) to guide VT delivery might reduce injury and improve outcomes. OBJECTIVE: To determine whether use of an RFM in addition to clinical assessment versus clinical assessment alone during mask ventilation in the delivery room reduces in-hospital mortality and morbidity of infants <37 weeks' gestation. STUDY SELECTION: Randomised controlled trials (RCTs) comparing RFM in addition to clinical assessment versus clinical assessment alone during mask ventilation in the delivery room of infants born <37 weeks' gestation. DATA ANALYSIS: Risk of bias was assessed using Covidence Collaboration tool and pooled into a meta-analysis using a random-effects model. The primary outcome was death prior to discharge. MAIN OUTCOME: Death before hospital discharge. RESULTS: Three RCTs enrolling 443 infants were combined in a meta-analysis. The pooled analysis showed no difference in rates of death before discharge with an RFM versus no RFM, relative risk (RR) 95% (CI) 0.98 (0.64 to 1.48). The pooled analysis suggested a significant reduction for brain injury (a combination of intraventricular haemorrhage and periventricular leucomalacia) (RR 0.65 (0.48 to 0.89), p=0.006) and for intraventricular haemorrhage (RR 0.69 (0.50 to 0.96), p=0.03) in infants receiving positive pressure ventilation with an RFM versus no RFM. CONCLUSION: In infants <37 weeks, an RFM in addition to clinical assessment compared with clinical assessment during mask ventilation resulted in similar in-hospital mortality, significant reduction for any brain injury and intraventricular haemorrhage. Further trials are required to determine whether RFMs should be routinely available for neonatal resuscitation.