Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Clin Chem Lab Med ; 62(5): 830-834, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-37852014

ABSTRACT

The indirect immunofluorescence assay on HEp-2 cells (HEp-2 IFA) is still considered the reference method to detect anti-nuclear antibodies (ANA) because of its high sensitivity and represents a relevant tool for the diagnosis of autoimmune rheumatic diseases. During the last decade, the International Consensus on ANA Patterns (ICAP) initiative promoted harmonization and understanding of HEp-2 IFA staining pattern nomenclature, as well as promoting their use in patient care by providing interpretation for HEp-2 IFA test results. In conjunction with a nationwide survey on the evolution of autoantibody diagnostics in autoimmune rheumatic diseases, we focused on the adherence of the Italian laboratories to the ICAP nomenclature analyzing its lights and shadows. The recent ICAP-oriented report, largely used today among Italian laboratories, also represents a further step in harmonizing and improving communication with the clinicians, adding value to laboratory findings and helping with critical clinical decisions.


Subject(s)
Autoimmune Diseases , Rheumatic Diseases , Humans , Laboratories, Clinical , Consensus , Antibodies, Antinuclear , Autoimmune Diseases/diagnosis , Fluorescent Antibody Technique, Indirect/methods , Italy
2.
Clin Chem Lab Med ; 61(7): 1199-1208, 2023 06 27.
Article in English | MEDLINE | ID: mdl-36989428

ABSTRACT

OBJECTIVES: Detection of antinuclear antibodies (ANA) by indirect immunofluorescence assay using HEp-2 cells (HEp-2 IFA) is used to screen for various autoimmune diseases. HEp-2 IFA suffers from variability, which hampers harmonization. METHODS: A questionnaire was developed to collect information on HEp-2 IFA methodology, computer-assisted diagnosis (CAD) systems, training, inter-observer variability, quality assessment, reagent lot change control, and method verification. The questionnaire was distributed to laboratories by Sciensano (Belgium), national EASI groups (Italy, Croatia, Portugal, Estonia, Greece) and ICAP (worldwide). Answers were obtained by 414 laboratories. The results were analysed in the framework of the recent EFLM/EASI/ICAP ANA recommendations (companion paper). RESULTS: Laboratories used either HEp-2, HEp-2000, or HEp-20-10 cells and most laboratories (80%) applied the same screening dilution for children and adults. The conjugate used varied between laboratories [IgG-specific (in 57% of laboratories) vs. polyvalent]. Sixty-nine percent of CAD users reviewed the automatic nuclear pattern and 53% of CAD users did not fully exploit the fluorescence intensity for quality assurance. Internal quality control was performed by 96% of the laboratories, in 52% of the laboratories only with strongly positive samples. Interobserver variation was controlled by 79% of the laboratories. Limited lot-to-lot evaluation was performed by 68% of the laboratories. Method verification was done by 80% of the respondents. CONCLUSIONS: Even though many laboratories embrace high-quality HEp-2 IFA, substantial differences in how HEp-2 IFA is performed and controlled remain. Acting according to the EFLM/EASI/ICAP ANA recommendations can improve the global performance and quality of HEp-2 IFA and nurture harmonization.


Subject(s)
Antibodies, Antinuclear , Autoimmune Diseases , Adult , Child , Humans , Antibodies, Antinuclear/analysis , Fluorescent Antibody Technique, Indirect/methods , Autoimmune Diseases/diagnosis , Immunologic Tests , Observer Variation
3.
J Appl Lab Med ; 7(1): 322-330, 2022 01 05.
Article in English | MEDLINE | ID: mdl-34996073

ABSTRACT

The establishment of the International Consensus on ANA Patterns (ICAP) in 2014-2015 was welcomed by members of the medical community as a significant improvement in guiding harmonization of ANA test interpretation and reporting. In the subsequent years, several itinerant meetings and continuous interaction with the community contributed to disseminate the ICAP harmonization on the immunofluorescence patterns observed in the indirect immunofluorescence assay on HEp-2 cells (HEp-2 IFA) and to promote progressive improvement in the classification of HEp-2 IFA patterns. The 6th ICAP Workshop was held in person on September 6, 2021 as a satellite meeting of the 15th Dresden Symposium on Autoantibodies. This article summarizes the major discussions at the meeting as well as outlining the current plans for the ICAP committee.


Subject(s)
Antibodies, Antinuclear , Autoimmune Diseases , Autoantibodies , Consensus , Fluorescent Antibody Technique, Indirect , Humans
4.
Immunol Res ; 69(6): 594-608, 2021 12.
Article in English | MEDLINE | ID: mdl-34625914

ABSTRACT

Results of the anti-nuclear antibodies-indirect immunofluorescence assay (anti-cell antibodies test) on HEp-2 cell substrates should be communicated to clinicians in a standardized way, adding value to laboratory findings and helping with critical clinical decisions. This paper proposes a test report based on the practices informed by 118 laboratories in 68 countries, with recommendations from the International Consensus on ANA Patterns (ICAP) group. Major focus is placed on the report format containing endpoint titers, immunofluorescence patterns together with anti-cell (AC) nomenclature, remarks on follow-up or reflex testing, and possible other autoantibody associations. ISO 15,189 directives were integrated into the test report. Special situations addressed include serum screening dilutions and endpoint titers, relevance of immunofluorescence patterns with special attention to cytoplasmic patterns, mixed and compound patterns, and how to report different titers corresponding to multiple patterns or autoantibodies in the same sample. This paper suggests a subtitle for the HEp-2-IIFA, namely anti-cell antibodies test, which could gradually substitute the original outdated ANA nomenclature. This ICAP pro forma report represents a further step in harmonizing the way relevant clinical information could be provided by laboratories.


Subject(s)
Antibodies, Antinuclear/immunology , Autoimmune Diseases/immunology , Cell Line , Consensus , Fluorescent Antibody Technique, Indirect , Humans , Practice Guidelines as Topic
5.
Adv Rheumatol ; 61(1): 32, 2021 06 09.
Article in English | MEDLINE | ID: mdl-34108043

ABSTRACT

OBJECTIVE: To evaluate the perception of rheumatologists regarding the recommendations of the Brazilian Consensus for detection of Autoantibodies (BCA) on HEp-2 Cells by Indirect Immunofluorescence assay (IFA) and how BCA recommendations help in clinical practice. METHODOLOGY: A structured questionnaire regarding the BCA recommendations for detection and interpretations of autoantibodies in HEp-2 cells was applied to randomly selected rheumatologists. The results were tabulated using the Microsoft® Excel program, expressed as a simple percentage and the dichotomous data were analyzed using the Chi-square test and the Epi Info® program. RESULTS: Four hundred fuorteen rheumatologists participated in the study: 70% of them considered their knowledge of the HEp-2 IFA test satisfactory or excellent, and 43% said they knew the BCA recommendations in general, without distinguishing the edition of the BCA to which they refer. The Revista Brasileira de Rheumatologia/Advances in Rheumatology was the means of dissemination most consulted by specialists (50%). According to the rheumatologists' opinion, the most relevant pattern was the homogeneous nuclear (78%) and 65% stated they were satisfied with the BCA recommendations at a level of satisfaction greater than or equal to 80%. There was no significant difference in the perception of rheumatologists from the several Brazilian geographic regions. CONCLUSION: Brazilian rheumatologists are aware of the BCA guidelines and most are satisfied with the content published, considering that the BCA recommendations assist positively in the clinical practice. Most rheumatologists recognize the patterns associated with rheumatic autoimmune diseases and have used BCA recommendations to interpret the results of the HEp-2 IFA test.


Subject(s)
Rheumatic Diseases , Autoantibodies , Autoimmune Diseases , Consensus , Fluorescent Antibody Technique, Indirect , Humans , Rheumatic Diseases/diagnosis , Rheumatologists
6.
Auto Immun Highlights ; 11(1): 17, 2020 Nov 23.
Article in English | MEDLINE | ID: mdl-33228811

ABSTRACT

BACKGROUND: The International Consensus on Antinuclear Antibody (ANA) Patterns (ICAP) has recently proposed nomenclature in order to harmonize ANA indirect immunofluorescence (IIF) pattern reporting. ICAP distinguishes competent-level from expert-level patterns. A survey was organized to evaluate reporting, familiarity, and considered clinical value of ANA IIF patterns. METHODS: Two surveys were distributed by European Autoimmunity Standardization Initiative (EASI) working groups, the International Consensus on ANA Patterns (ICAP) and UK NEQAS to laboratory professionals and clinicians. RESULTS: 438 laboratory professionals and 248 clinicians from 67 countries responded. Except for dense fine speckled (DFS), the nuclear competent patterns were reported by > 85% of the laboratories. Except for rods and rings, the cytoplasmic competent patterns were reported by > 72% of laboratories. Cytoplasmic IIF staining was considered ANA positive by 55% of clinicians and 62% of laboratory professionals, with geographical and expertise-related differences. Quantification of fluorescence intensity was considered clinically relevant for nuclear patterns, but less so for cytoplasmic and mitotic patterns. Combining IIF with specific extractable nuclear antigens (ENA)/dsDNA antibody testing was considered most informative. Of the nuclear competent patterns, the centromere and homogeneous pattern obtained the highest scores for clinical relevance and the DFS pattern the lowest. Of the cytoplasmic patterns, the reticular/mitochondria-like pattern obtained the highest scores for clinical relevance and the polar/Golgi-like and rods and rings patterns the lowest. CONCLUSION: This survey confirms that the major nuclear and cytoplasmic ANA IIF patterns are considered clinically important. There is no unanimity on classifying DFS, rods and rings and polar/Golgi-like as a competent pattern and on reporting cytoplasmic patterns as ANA IIF positive.

10.
Rev Bras Reumatol Engl Ed ; 56(1): 28-36, 2016.
Article in English, Portuguese | MEDLINE | ID: mdl-27267331

ABSTRACT

INTRODUCTION/OBJECTIVE: Recent evidence suggests that abnormalities involving Th17 lymphocytes are associated with the pathophysiology of systemic lupus erythematosus (SLE). In addition, multifunctional T cells (MFT), i.e., those producing multiple cytokines simultaneously, are present in the inflammatory milieu and may be implicated in the autoimmune process observed in SLE. In the present study, we aimed to characterize the functional status of CD4(+) T cells in SLE by simultaneously determining the concentration of IL-2, IFN-γ and IL-17 in lymphocyte cultures under exogenous and self-antigenic stimuli. PATIENTS AND METHODS: Eighteen patients with active disease, 18 with inactive disease, and 14 healthy controls had functional status of CD4(+) T cells analyzed. RESULTS: We found that SLE patients presented a decreased number of total CD4(+) cells, an increased number of activated T cells, and an increased frequency of Th17 cells compared to healthy controls (HC). MFT cells had increased frequency in SLE patients and there was an increased frequency of tri-functional MFT in patients with active SLE compared with those with inactive SLE. Interestingly, MTF cells produced larger amounts of IFNγ than mono-functional T cells in patients and controls. CONCLUSION: Taken together these data indicate the participation of recently activated Th17 cells and MTF cells in the SLE pathophysiology.


Subject(s)
CD4-Positive T-Lymphocytes/immunology , Lupus Erythematosus, Systemic/immunology , Lupus Erythematosus, Systemic/physiopathology , Th17 Cells/immunology , CD4 Lymphocyte Count , Cytokines , Flow Cytometry , Humans , Lymphocyte Activation
11.
Auto Immun Highlights ; 7(1): 1, 2016 Dec.
Article in English | MEDLINE | ID: mdl-26831867

ABSTRACT

The International Consensus on ANA Patterns (ICAP) was initiated as a workshop aiming to thoroughly discuss and achieve consensus regarding the morphological patterns observed in the indirect immunofluorescence assay on HEp-2 cells. One of the topics discussed at the second ICAP workshop, and addressed in this paper, was the harmonization of reporting ANA test results. This discussion centered on the issue if cytoplasmic and mitotic patterns should be reported as positive or negative. This report outlines the issues that impact on two major different reporting methods. Although it was appreciated by all participants that cytoplasmic and mitotic patterns are clinically relevant, implications for existing diagnostic/classification criteria for ANA-associated diseases in particular hampered a final consensus on this topic. Evidently, a more concerted action of all relevant stakeholders is required. Future ICAP workshops may help to facilitate this action.

12.
Front Immunol ; 6: 412, 2015.
Article in English | MEDLINE | ID: mdl-26347739

ABSTRACT

During the 12th International Workshop on Autoantibodies and Autoimmunity held in Sao Paulo, Brazil, on August 28, 2014, a full day session was devoted to establishing a consensus on the nomenclature of staining patterns observed in the antinuclear antibody (ANA) indirect immunofluorescence test on HEp-2 cells. The current report summarizes the collective agreements with input from the host Brazilian and international communities that represented research, clinical, and diagnostic service laboratories. Patterns are categorized in three major groups (nuclear, cytoplasmic, and mitotic patterns) and each pattern has been defined and described in detail. The consensus nomenclature and representative patterns are made available online at the international consensus on antinuclear antibody pattern (ICAP) website (www.ANApatterns.org). To facilitate continuous improvement and input, specific comments on ICAP are encouraged and these will be discussed in subsequent ICAP meetings. The ultimate goal with the establishment of the ICAP is to promote harmonization and understanding of autoantibody test nomenclature, as well as interpretation guidelines for ANA testing, thereby optimizing usage in patient care.