Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurol Neurosurg Psychiatry ; 94(2): 151, 2023 02.
Article in English | MEDLINE | ID: mdl-36261286

ABSTRACT

INTRODUCTION: Diagnosing ocular myasthenia gravis (MG) can be challenging because serum antibodies are often not detected. We aimed to explore whether determining extraocular muscle (EOM) weakness using orthoptic measures, including an adapted Hess chart examination, can aid in diagnosing MG. METHODS: We conducted a prospective study among patients with acetylcholine receptor antibody positive MG (20 recently diagnosed, 19 chronic) and 14 seronegative MG patients. We compared orthoptic measures to 19 healthy and 18 disease controls with Graves orbitopathy, chronic progressive external ophthalmoplegia or oculopharyngeal muscular dystrophy. Maximal eye duction angles were measured using a synoptophore. Gaze deviations between eyes were measured using standard Hess chart examination with addition of 1 min persistent gaze to assess MG-associated fatiguability. Receiver operating characteristics curve analysis was performed. RESULTS: For duction angles, the area under the curve (AUC) was 0.73 comparing MG to healthy, and 0.69 comparing to patient controls. For the outer field of the Hess chart, the AUC was 0.89 comparing to healthy and 0.54 to patient controls. For drift, the AUC was 0.93 comparing to healthy and 0.93 to patient controls. The sensitivity and specificity of the presence of drift was 81% and 100%. DISCUSSION: Orthoptic measurements can be used to diagnose MG by quantifying EOM weakness and fatiguability. Drift during persistent gaze on a Hess chart is specific for MG and could be used for diagnostic purposes. The Hess chart examination is widely available, inexpensive and fast. Moreover, orthoptic measurements may be a clinically relevant outcome measure for clinical trials.


Subject(s)
Graves Ophthalmopathy , Myasthenia Gravis , Ocular Motility Disorders , Humans , Oculomotor Muscles , Orthoptics , Graves Ophthalmopathy/complications , Prospective Studies , Myasthenia Gravis/diagnosis , Ocular Motility Disorders/diagnosis
2.
J AAPOS ; 14(6): 478-83, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21168070

ABSTRACT

PURPOSE: To evaluate the performance of the autorefractor Retinomax K-plus2 and the photoscreener plusoptiX S08 in measuring refractive errors by comparing them with cycloplegic retinoscopy (CR) and to assess limitations associated with their use. METHODS: Cross-sectional study to compare data from CR, performed by an orthoptist, to data from Retinomax K-plus2 and plusoptiX S08 performed by a lay screener. Sensitivity and specificity for the detection of significant refractive errors were determined according to American Academy of Pediatric Ophthalmology and Strabismus criteria. RESULTS: Two hundred children were included, with a mean age of 5.2 ± 2.6 years (3 months to 11 years). Compared to CR, the plusoptiX S08 showed a mean difference of -1.13 ± 1.25 D (95% limits of agreement [LOA], -3.59 to +1.32) for spherical equivalent (SE) and -0.23 ± 0.53 D (LOA, -1.28 to +0.81) for the cylinder. Mean difference for the Retinomax K-plus2 before cycloplegia was -0.08 ± 0.58 D (LOA, -1.23 to +1.06) for SE and 0.03 ± 0.38 D (LOA, -0.72 to +0.78) for the cylinder; after cycloplegia -2.11 ± 1.64 D (LOA, -5.33 to +1.10) for SE and -0.06 ± 0.47 D (LOA, -0.98 to +0.86) for the cylinder. Sensitivity for detecting hyperopia >3.5 D with the plusoptiX S08 was 33.3%, the Retinomax before cycloplegia 31.0% and after cycloplegia 84.6% and high for detecting myopia, astigmatism, and anisometropia. CONCLUSIONS: Retinomax K-plus2 and plusoptiX S08 have high sensitivity for the detection of myopia, astigmatism, and anisometropia compared to cycloplegic retinoscopy; however, when used without cycloplegia, hyperopia is underestimated.


Subject(s)
Ophthalmology/standards , Orthoptics/standards , Refractive Errors/diagnosis , Retinoscopy/methods , Vision Screening , Anisometropia/diagnosis , Astigmatism/diagnosis , Child , Child, Preschool , Cross-Sectional Studies , Humans , Hyperopia/diagnosis , Infant , Mydriatics , Myopia/diagnosis , Reproducibility of Results , Sensitivity and Specificity , Vision Screening/instrumentation , Vision Screening/methods , Vision Screening/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...