Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Heart Rhythm ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38336193

ABSTRACT

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

2.
J Am Heart Assoc ; : e031418, 2023 Nov 10.
Article in English | MEDLINE | ID: mdl-37947117

ABSTRACT

Background Medication nonadherence contributes to poor health outcomes but remains challenging to identify. This study assessed the association between self-rated adherence and systolic blood pressure, low-density lipoprotein cholesterol levels, cardiovascular events, and all-cause mortality in SPRINT (Systolic Blood Pressure Intervention Trial). Methods and Results A total of 9361 patients randomized to 2 systolic blood pressure target groups, <120 mm Hg (intensive) and <140 mm Hg (standard), self-rated their medication adherence at each visit by marking a scale, ranging from 0% to 100%. Lower and high adherence were defined as scores ≤80% and >80%, respectively. Linear mixed effect regression models and Cox proportional hazard models were used to evaluate the association between self-rated adherence and systolic blood pressure and low-density lipoprotein cholesterol and cardiovascular events and all-cause mortality, respectively. A total of 9278 participants (mean age 68±9.4 years, 35.6% female) had repeated self-rated adherence measurements available, with a mean of 15±4 measurements per participant over 3.8 years follow-up. Of these, 2694 participants (29.0%) had ≥1 adherence measurements ≤80%. Compared with high-adherent patients, patients with lower adherence had significantly higher estimated on-treatment systolic blood pressure at 2-year follow-up: 128.7 (95% CI, 127.6-129.9) versus 120.0 (95% CI, 119.7-120.2) mm Hg in the intensive arm; and 139.8 (95% CI 138.4-141.1) versus 135.0 (95% CI 134.7-135.2) in the standard arm. Moreover, lower adherence was associated with an estimated 11 mg/dL higher low-density lipoprotein cholesterol level, more cardiovascular events (hazard ratio [HR], 1.69 [95% CI, 1.20-2.39]), and higher all-cause mortality (HR, 1.63 [95% CI, 1.16-2.31]). Conclusions Self-rated adherence allows identification of lower medication adherence and correlates with blood pressure control, low-density lipoprotein cholesterol levels, and adverse outcomes.

3.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Article in English | MEDLINE | ID: mdl-36030464

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Humans , Treatment Outcome , Defibrillators, Implantable/adverse effects
4.
Circulation ; 145(5): 321-329, 2022 02.
Article in English | MEDLINE | ID: mdl-34779221

ABSTRACT

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/standards , Aged , Arrhythmias, Cardiac/diagnosis , Female , Humans , Male , Middle Aged , Prospective Studies , Treatment Outcome
5.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Article in English | MEDLINE | ID: mdl-32757521

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/adverse effects , Aged , Cardiomyopathies/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Electrodes, Implanted/adverse effects , Equipment Failure , Female , Follow-Up Studies , Heart Diseases/therapy , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Prosthesis Design
6.
Sci Transl Med ; 9(421)2017 Dec 20.
Article in English | MEDLINE | ID: mdl-29263233

ABSTRACT

Patients with depression often suffer from cognitive impairments that contribute to disease burden. We used social defeat-induced persistent stress (SDPS) to induce a depressive-like state in rats and then studied long-lasting memory deficits in the absence of acute stressors in these animals. The SDPS rat model showed reduced short-term object location memory and maintenance of long-term potentiation (LTP) in CA1 pyramidal neurons of the dorsal hippocampus. SDPS animals displayed increased expression of synaptic chondroitin sulfate proteoglycans in the dorsal hippocampus. These effects were abrogated by a 3-week treatment with the antidepressant imipramine starting 8 weeks after the last defeat encounter. Next, we observed an increase in the number of perineuronal nets (PNNs) surrounding parvalbumin-expressing interneurons and a decrease in the frequency of inhibitory postsynaptic currents (IPSCs) in the hippocampal CA1 region in SDPS animals. In vivo breakdown of the hippocampus CA1 extracellular matrix by the enzyme chondroitinase ABC administered intracranially restored the number of PNNs, LTP maintenance, hippocampal inhibitory tone, and memory performance on the object place recognition test. Our data reveal a causal link between increased hippocampal extracellular matrix and the cognitive deficits associated with a chronic depressive-like state in rats exposed to SDPS.


Subject(s)
Cognitive Dysfunction/pathology , Depression/pathology , Extracellular Matrix/metabolism , Hippocampus/pathology , Animals , CA1 Region, Hippocampal/drug effects , CA1 Region, Hippocampal/pathology , CA1 Region, Hippocampal/physiopathology , Chondroitin ABC Lyase/metabolism , Chondroitin Sulfate Proteoglycans/metabolism , Chronic Disease , Cognitive Dysfunction/complications , Cognitive Dysfunction/drug therapy , Cognitive Dysfunction/physiopathology , Depression/complications , Depression/drug therapy , Depression/physiopathology , Hippocampus/drug effects , Hippocampus/physiopathology , Imipramine/pharmacology , Imipramine/therapeutic use , Interneurons/drug effects , Interneurons/pathology , Male , Memory/drug effects , Neural Inhibition/drug effects , Rats, Wistar , Social Behavior , Stress, Psychological/drug therapy , Stress, Psychological/etiology , Stress, Psychological/physiopathology , Synapses/drug effects , Synapses/metabolism
7.
Anim Cogn ; 18(4): 867-74, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25771964

ABSTRACT

When learning a language, it is crucial to know which syllables of a continuous sound string belong together as words. Human infants achieve this by attending to pauses between words or to the co-occurrence of syllables. It is not only humans that can segment a continuous string. Songbirds learning their song tend to copy 'chunks' from one or more tutors' songs and combine these into their own song. In the tutor songs, these chunks are often separated by pauses and a high co-occurrence of elements, suggesting that these features affect chunking and song learning. We examined experimentally whether the presence of pauses and element co-occurrence affect the ability of adult zebra finches to discriminate strings of song elements. Using a go/no-go design, two groups of birds were trained to discriminate between two strings. In one group (Pause-group), pauses were inserted between co-occurring element triplets in the strings, and in the other group (No-pause group), both strings were continuous. After making a correct discrimination, an individual proceeded to a reversal training using string segments. Segments were element triplets consistent in co-occurrence, triplets that were partly consistent in composition and triplets consisting of elements that did not co-occur in the strings. The Pause-group was faster in discriminating between the two strings. This group also responded differently to consistent triplets in the reversal training, compared to inconsistent triplets. The No-pause group did not differentiate among the triplet types. These results indicate that pauses in strings of song elements aid song discrimination and memorization of co-occurring element groups.


Subject(s)
Auditory Perception , Finches/physiology , Vocalization, Animal , Animals , Behavior, Animal , Conditioning, Operant , Discrimination Learning , Female , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...