Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Afr J Emerg Med ; 12(3): 172-176, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35611145

ABSTRACT

Background: Severe Coronavirus Disease 2019 (COVID-19) can develop pneumonia with severe complications. The Oxygen Efficient Respiratory Aid (OxEraTM) device has been granted SAPHRA approval for emergency COVID-19 pandemic use. The device has the potential to be used widely in the healthcare sector due to its efficient oxygen supply and adjustable wall positive expiratory pressure (PEP). Objectives: We assessed whether the OxEraTM device was safe to use in a healthy adult volunteer population. Our primary objective was to ensure there was no asphyxiation, as assessed by changes observed from baseline End Tidal Carbon Dioxide (ETCO2) exceeding 6.3 mmHg and above the 45 mmHg threshold. We also monitored changes in vital organ signs and assessed the pain and comfort of the participant at various intervals with changes in PEPs. Methods: This was an experimental safety study of the OxEraTM Device on 30 healthy participants at the ICU training centre of Chris Hani Baragwanath Academic Hospital, Johannesburg, South Africa. Each participant had basic vital-signs, ETCO2, and Oxygen saturation percentages (SpO2%) taken at baseline until the end of 2 h. In the first 20 min, the PEP was increased by 5 cmH20 until 20 min, then continued for the rest of the time on a PEP of 5 cmH20. At each interval, vital signs, subjective comfort, pain, and visual scores were measured. Results: Thirty healthy participants were enrolled. There was no significant difference in ETCO2 from baseline until 2 h. No participant experienced an increase in measured ETCO2 greater than 45 mmHg and no increase in ETCO2 from baseline was greater than 6.3 mmHg. The median increase in ETCO2 over the study period was 2 mmHg. There were no significant changes in respiratory rate and blood pressure. The heart rate decreased significantly (73-68 bpm). The VAS and comfort score had a significant increase over the 2 h from baseline of 0-2 at maximum; however, the PAS scores showed no significant increase. Conclusion: Overall the OxEraTM device achieved the safety endpoints set out. There was no sign of asphyxiation and there were appropriate physiological responses to changes in PEP once applied. The comfort of the mask did worsen over the 2 h; however, the scores were minimally worse on PEP application but improved once-off PEP. No adverse event was recorded at all.

2.
Crit Care Res Pract ; 2021: 3935098, 2021.
Article in English | MEDLINE | ID: mdl-34956676

ABSTRACT

INTRODUCTION: The coagulation abnormalities resulting from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been attributed to inflammation and subsequent cytokine storm. Thromboelastography (TEG) is a point-of-care test used to assess clot formation and degradation in whole blood and is an indicator of the overall real-time coagulopathic state of the patient. METHODS: A single-centre, prospective, observational cohort study was conducted in South Africa, analysing the coagulation patterns of 41 patients with hypoxia related to SARS-CoV-2 using serial thromboelastography (TEG) on admission, after 48 hours, and at resolution of hypoxia/day 10. Results: Two-thirds (n = 26) were women. The median age was 61 (IQR 50-67), and the majority (88%) were Black patients. Almost half (22) of the patients were critically ill and ventilated, with median SOFA and SAPS2 scores of 3 and 22 (IQR2-4 and 18-30), respectively. The prevalence of hypercoagulability was 0.54 (95% CI 0.46-0.62), whilst 29/41 (0.71, CI 0.64-0.78)) met the definition of hypofibrinolysis. Differences between the hypercoagulable (HC) and non-hypercoagulable groups remained apparent at 48 hours after anticoagulation. At this time point, the K time was significantly lower (p ˂ 0,01), and the α-angle (p ˂ 0,01) and maximum amplitude (MA) (p ˂ 0,01) were significantly higher in the HC cohort. At resolution of hypoxia, or day 10, only MA was significantly higher in the hypercoagulable group compared to the non-hypercoagulable group (p = 0.01). The initial impairment in fibrinolysis (Ly30), α angle, and MA were significantly associated with mortality, with p values of 0.006, 0.031, and 0.04, respectively. CONCLUSIONS: In this South African population, hypercoagulability was a highly prevalent phenomenon in COVID-19 disease. It was typified by hypofibrinolysis and a persistently elevated MA, despite anticoagulation therapy.

3.
Clin Case Rep ; 2(3): 88-92, 2014 Jun.
Article in English | MEDLINE | ID: mdl-25356257

ABSTRACT

KEY CLINICAL MESSAGE: Intracranial Hodgkin lymphoma (HL) is considered so atypical that an intracranial space-occupying lesion in a patient with known HL should be thoroughly investigated to rule out a second disease process.

SELECTION OF CITATIONS
SEARCH DETAIL