Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 92(21): 14509-14516, 2020 11 03.
Article in English | MEDLINE | ID: mdl-33054153

ABSTRACT

Real-time label-free techniques are used to profile G protein-coupled receptor (GPCR) signaling pathways in living cells. However, interpreting the label-free signal responses is challenging, and previously reported methods do not reliably separate pathways from each other. In this study, a continuous angular-scanning surface plasmon resonance (SPR) technique is utilized for measuring label-free GPCR signal profiles. We show how the continuous angular-scanning ability, measuring up to nine real-time label-free parameters simultaneously, results in more information-rich label-free signal profiles for different GPCR pathways, providing a more accurate pathway separation. For this, we measured real-time full-angular SPR response curves for Gs, Gq, and Gi signaling pathways in living cells. By selecting two of the most prominent label-free parameters: the full SPR curve angular and intensity shifts, we present how this analysis approach can separate each of the three signaling pathways in a straightforward single-step analysis setup, without concurrent use of signal inhibitors or other response modulating compounds.


Subject(s)
Receptors, G-Protein-Coupled/metabolism , Signal Transduction , Surface Plasmon Resonance/methods , Animals , CHO Cells , Cricetulus , Humans
2.
SLAS Technol ; 24(6): 543-555, 2019 12.
Article in English | MEDLINE | ID: mdl-31096846

ABSTRACT

We describe the development of a high-resolution, noncontact fraction collector for liquid chromatography (LC) separations, allowing high-resolution fractionation in high-density well plates. The device is based on a low-dead-volume solenoid valve operated at 1-30 Hz for accurate collection of fractions of equal volume. The solenoid valve was implemented in a modified autosampler resulting in the so-called FractioMate fractionator. The influence of the solenoid supply voltage on solvent release was determined and the effect of the frequency, flow rate, and mobile phase composition was studied. For this purpose, droplet release was visually assessed for a wide range of frequencies and flow rates, followed by quantitative evaluation of a selection of promising settings for highly accurate, repeatable, and stable fraction collection. The potential of the new fraction collector for LC-based bioactivity screening was demonstrated by fractionating the LC eluent of a mixture of estrogenic and androgenic compounds, and a surface water sample (blank and spiked with bioactives) combining mass spectrometric detection and two reporter gene assays for bioactivity detection of the fractions. Additionally, a mixture of two compounds was repeatedly LC separated and fractionated to assess the feasibility of the system for analyte isolation followed by nuclear magnetic resonance analysis.


Subject(s)
Chemical Fractionation/instrumentation , Chromatography, Liquid/instrumentation , Biological Assay , Chromatography, High Pressure Liquid , Genes, Reporter , Humans , MCF-7 Cells , Magnetic Resonance Spectroscopy , Mass Spectrometry , Solvents
3.
Anal Chem ; 83(1): 125-32, 2011 Jan 01.
Article in English | MEDLINE | ID: mdl-21117623

ABSTRACT

The development of a contactless postcolumn spotter technology capable of rapidly and accurately depositing LC eluent onto another platform (e.g., 1536-well microtiter plates) is described. Many detection methodologies are suitable for online analysis, such as mass spectrometry, UV-vis, and fluorescence. In some cases, when online analysis is less suitable, off-line postcolumn analysis is the methodology of choice and usually relies on LC-based fractionation prior to detection (e.g., MALDI-MS, Raman spectrsocopy, biochemical assays). As fractionation generally involves loss in resolution, the technology described here allows high-resolution contactless fractionation by tailoring the fractionation frequency to the chromatographic peaks and mixing in of postcolumn reagents. Droplet ejection at frequencies of at least 6 Hz could be performed in the nanoliter to low microliter range with repeatabilities of ∼6%. Furthermore, multiple droplets can be ejected at the same position thereby allowing adjustment of fractionation volume and speed. The technology was evaluated, optimized, and validated prior to two proof-of-principle demonstrations comprising off-line chemical detection of injected fluorescein and off-line postcolumn biochemical detection of acetylcholine-binding protein ligands, both based on 1536-well plate reader analysis.


Subject(s)
Chemical Fractionation/methods , Chromatography, Liquid/methods , Nanotechnology/methods , Animals , Carrier Proteins/isolation & purification , Carrier Proteins/metabolism , Cell Line , Chemical Fractionation/instrumentation , Fluorescein/chemistry , Indicators and Reagents/chemistry , Mass Spectrometry , Nanotechnology/instrumentation , Reproducibility of Results , Time Factors
4.
Anal Bioanal Chem ; 398(7-8): 3023-32, 2010 Dec.
Article in English | MEDLINE | ID: mdl-20872136

ABSTRACT

One way to profile complex mixtures for receptor affinity is to couple liquid chromatography (LC) on-line to biochemical detection (BCD). A drawback of this hyphenated screening approach is the relatively high consumption of sample, receptor protein and (fluorescently labeled) tracer ligand. Here, we worked toward minimization of sample and reagent consumption, by coupling nano-LC on-line to a light-emitting diode (LED) based capillary confocal fluorescence detection system capable of on-line BCD with low-flow rates. In this fluorescence detection system, a capillary with an extended light path (bubble cell) was used as a detection cell in order to enhance sensitivity. The technology was applied to a fluorescent enhancement bioassay for the acetylcholine binding protein, a structural analog of the extracellular ligand-binding domain of neuronal nicotinic acetylcholine receptors. In the miniaturized setup, the sensitive and low void volume LED-induced confocal fluorescence detection system operated in flow injection analysis mode allowing the measurement of IC(50) values, which were comparable with those measured by a conventional plate reader bioassay. The current setup uses 50 nL as injection volume with a carrier flow rate of 400 nL/min. Finally, coupling of the detection system to gradient reversed-phase nano-LC allowed analysis of mixtures in order to identify the bioactive compounds present by injecting 10 nL of each mixture.


Subject(s)
Biological Assay/methods , Chromatography, Liquid/methods , Flow Injection Analysis/methods , Microfluidics/methods , Microscopy, Fluorescence/methods , Biological Assay/instrumentation , Carrier Proteins/analysis , Microfluidics/instrumentation
5.
J Biomol Screen ; 12(8): 1074-83, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18087072

ABSTRACT

A flow-through fluorescence polarization (FP) detection system that makes use of a novel high-performance liquid chromatography (HPLC) fluorescence detector modified with polarization filters was developed. This flow-through FP detection system was evaluated by using a novel and very cost-effective bioassay for cyclic adenosine monophosphate (cAMP). The bioassay was first evaluated and optimized in an FP plate reader format and subsequently in a flow-through bioassay setup. The principle of the bioassay is based on the competition of cAMP and a fluorescent cAMP derivative for the cAMP binding domain of protein kinase A. cAMP could accurately be determined over a range of 0.8 to 30 pmol/well in the plate reader FP assay and over a range of 0.3 to 50 pmol/well in the flow-through FP assay setup. High Z' factors (i.e., 0.89 for the plate reader and 0.93 for the flow-through FP cAMP assay, respectively) indicated robust assays. Finally, functional cAMP signaling of the human histamine H(3) G-protein-coupled receptor (GPCR) in cell cultures was measured with both assay formats with good sensitivities and assay windows. The pEC(50) values obtained in both assay formats were in accordance with those obtained with standard methods. The flow-through FP detection system could thus be used as a cost-effective alternative to FP plate reader assays. Moreover, the novel flow-through FP detection system for cAMP constitutes a good analytical tool to be used in the GPCR research field as an alternative to the use of FP plate readers or radioactive laboratories nowadays used for cAMP measurements.


Subject(s)
Cyclic AMP/biosynthesis , Fluorescence Polarization/methods , Receptors, G-Protein-Coupled/metabolism , Animals , CHO Cells , Cattle , Cricetinae , Cricetulus , Dose-Response Relationship, Drug , Humans , Nucleotides/metabolism , Receptors, G-Protein-Coupled/agonists , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...