Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
Add more filters










Publication year range
1.
Nano Converg ; 10(1): 45, 2023 Sep 16.
Article in English | MEDLINE | ID: mdl-37715925

ABSTRACT

The current standard method of diagnosing coronavirus disease 2019 (COVID-19) involves uncomfortable and invasive nasopharyngeal (NP) sampling using cotton swabs (CS), which can be unsuitable for self-testing. Although mid-turbinate sampling is an alternative, it has a lower diagnostic yield than NP sampling. Nasal wash (NW) has a similar diagnostic yield to NP sampling, but is cumbersome to perform. In this study, we introduce a 3D printed fluidic swab (3DPFS) that enables easy NW sampling for COVID-19 testing with improved diagnostic yield. The 3DPFS comprises a swab head, microchannel, and socket that can be connected to a syringe containing 250 µL of NW solution. The 3DPFS efficiently collects nasal fluid from the surface of the nasal cavity, resulting in higher sensitivity than CS for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This was confirmed by both reverse transcription-quantitative polymerase chain reaction (RT-qPCR) and lateral flow assays (LFA) in virus-spiked nasal samples and clinical samples. Additionally, users reported greater comfort when using the 3DPFS compared to CS. These findings suggest that the 3DPFS can improve the performance of COVID-19 testing by facilitating efficient and less painful nasal sample collection.

2.
J Nanobiotechnology ; 20(1): 30, 2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35012567

ABSTRACT

BACKGROUND: Most high-throughput screening (HTS) systems studying the cytotoxic effect of chimeric antigen receptor (CAR) T cells on tumor cells rely on two-dimensional cell culture that does not recapitulate the tumor microenvironment (TME). Tumor spheroids, however, can recapitulate the TME and have been used for cytotoxicity assays of CAR T cells. But a major obstacle to the use of tumor spheroids for cytotoxicity assays is the difficulty in separating unbound CAR T and dead tumor cells from spheroids. Here, we present a three-dimensional hanging spheroid plate (3DHSP), which facilitates the formation of spheroids and the separation of unbound and dead cells from spheroids during cytotoxicity assays. RESULTS: The 3DHSP is a 24-well plate, with each well composed of a hanging dripper, spheroid wells, and waste wells. In the dripper, a tumor spheroid was formed and mixed with CAR T cells. In the 3DHSP, droplets containing the spheroids were deposited into the spheroid separation well, where unbound and dead T and tumor cells were separated from the spheroid through a gap into the waste well by tilting the 3DHSP by more than 20°. Human epidermal growth factor receptor 2 (HER2)-positive tumor cells (BT474 and SKOV3) formed spheroids of approximately 300-350 µm in diameter after 2 days in the 3DHSP. The cytotoxic effects of T cells engineered to express CAR recognizing HER2 (HER2-CAR T cells) on these spheroids were directly measured by optical imaging, without the use of live/dead fluorescent staining of the cells. Our results suggest that the 3DHSP could be incorporated into a HTS system to screen for CARs that enable T cells to kill spheroids formed from a specific tumor type with high efficacy or for spheroids consisting of tumor types that can be killed efficiently by T cells bearing a specific CAR. CONCLUSIONS: The results suggest that the 3DHSP could be incorporated into a HTS system for the cytotoxic effects of CAR T cells on tumor spheroids.


Subject(s)
Cell Survival/physiology , High-Throughput Screening Assays/methods , Receptors, Chimeric Antigen/genetics , Spheroids, Cellular , Tumor Microenvironment , Cell Culture Techniques, Three Dimensional , Cell Line, Tumor , Humans , Immunotherapy, Adoptive , Spheroids, Cellular/chemistry , Spheroids, Cellular/cytology , Spheroids, Cellular/metabolism , Tumor Microenvironment/genetics , Tumor Microenvironment/physiology
3.
Int J Mol Sci ; 22(24)2021 Dec 16.
Article in English | MEDLINE | ID: mdl-34948310

ABSTRACT

Extracellular vesicles (EVs) are a group of membrane vesicles that play important roles in cell-to-cell and interspecies/interkingdom communications by modulating the pathophysiological conditions of recipient cells. Recent evidence has implied their potential roles in the gut-brain axis (GBA), which is a complex bidirectional communication system between the gut environment and brain pathophysiology. Despite the evidence, the roles of EVs in the gut microenvironment in the GBA are less highlighted. Moreover, there are critical challenges in the current GBA models and analyzing techniques for EVs, which may hinder the research. Currently, advances in organ-on-a-chip (OOC) technologies have provided a promising solution. Here, we review the potential effects of EVs occurring in the gut environment on brain physiology and behavior and discuss how to apply OOCs to research the GBA mediated by EVs in the gut microenvironment.


Subject(s)
Brain-Gut Axis/physiology , Brain/physiology , Cellular Microenvironment/physiology , Extracellular Vesicles/physiology , Gastrointestinal Tract/physiology , Animals , Digestive System , Humans , Lab-On-A-Chip Devices
4.
Micromachines (Basel) ; 12(10)2021 Oct 14.
Article in English | MEDLINE | ID: mdl-34683295

ABSTRACT

Malaria affects 228 million people worldwide each year, causing severe disease and worsening the conditions of already vulnerable populations. In this review, we explore how malaria has been detected in the past and how it can be detected in the future. Our primary focus is on finding new directions for low-cost diagnostic methods that unspecialized personnel can apply in situ. Through this review, we show that microfluidic devices can help pre-concentrate samples of blood infected with malaria to facilitate the diagnosis. Importantly, these devices can be made cheaply and be readily deployed in remote locations.

5.
Sensors (Basel) ; 20(4)2020 Feb 21.
Article in English | MEDLINE | ID: mdl-32098268

ABSTRACT

Molecular diagnostics for sepsis is still a challenge due to the presence of compounds that interfere with gene amplification and bacteria at concentrations lower than the limit of detection (LOD). Here, we report on the development of a 3D printed modular microfluidic device (3DpmµFD) that preconcentrates bacteria of interest in whole blood and purifies their genomic DNA (gDNA). It is composed of a W-shaped microchannel and a conical microchamber. Bacteria of interest are magnetically captured from blood in the device with antibody conjugated magnetic nanoparticles (Ab-MNPs) at 5 mL/min in the W-shaped microchannel, while purified gDNA of the preconcentrated bacteria is obtained with magnetic silica beads (MSBs) at 2 mL/min in the conical microchamber. The conical microchamber was designed to be connected to the microchannel after the capturing process using a 3D-printed rotary valve to minimize the exposure of the MSBs to interfering compounds in blood. The pretreatment process of spiked blood (2.5 mL) can be effectively completed within about 50 min. With the 3DpmµFD, the LOD for the target microorganism Escherichia coli O157:H7 measured by both polymerase chain reaction (PCR) with electrophoresis and quantitative PCR was 10 colony forming unit (CFU) per mL of whole blood. The results suggest that our method lowers the LOD of molecular diagnostics for pathogens in blood by providing bacterial gDNA at high purity and concentration.


Subject(s)
Bacteria/metabolism , DNA, Bacterial/metabolism , Lab-On-A-Chip Devices , Pathology, Molecular/methods , Bacteria/genetics , Escherichia coli/genetics , Escherichia coli/metabolism , Polymerase Chain Reaction
6.
Micromachines (Basel) ; 11(2)2020 Feb 16.
Article in English | MEDLINE | ID: mdl-32079062

ABSTRACT

Influenza A viruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (µFPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the µFPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device.

7.
Anal Chem ; 91(22): 14214-14219, 2019 11 19.
Article in English | MEDLINE | ID: mdl-31631648

ABSTRACT

Pipetting techniques play a crucial role in obtaining reproducible and reliable results, especially when seeding cells on small target areas, such as on microarrays, biochips or microfabricated cell culture systems. For very rare cells, such as human primary skeletal muscle cells (skMCs), manual (freehand) cell seeding techniques invariably result in nonuniform cell spreading and heterogeneous cell densities, giving rise to undesirable variations in myogenesis and differentiation. To prevent such technique-dependent variation, we have designed and fabricated a simple, low-cost pipet guidance device (PGD), and holder that works with hand-held pipettes. This work validates the accuracy and reproducibility of the PGD platform and compares its effectiveness with manual and robotic seeding techniques. The PGD system ensures reproducibility of cell seeding, comparable to that of more expensive robotic dispensing systems, resulting in a high degree of cell uniformity and homogeneous cell densities, while also enabling cell community studies. As compared to freehand pipetting, PGD-assisted seeding of C2C12 mouse myoblasts showed 5.3 times more myotube formation and likewise myotubes derived from PGD-seeded human primary skMCs were 3.6 times thicker and 2.2 times longer. These results show that this novel, yet simple PGD-assisted pipetting technique provides precise cell seeding on small targets, ensuring reproducible and reliable high-throughput cell assays.


Subject(s)
Cell Culture Techniques/instrumentation , Muscle, Skeletal/cytology , Tissue Array Analysis/instrumentation , Cell Count , Cell Differentiation , Cell Proliferation , Cells, Cultured , Equipment Design , Humans , Microarray Analysis
8.
PLoS One ; 14(10): e0223193, 2019.
Article in English | MEDLINE | ID: mdl-31647823

ABSTRACT

Microchips are widely used to separate circulating tumor cells (CTCs) from whole blood by virtues of sophisticated manipulation for microparticles. Here, we present a chip with an 8 µm high and 27.9 mm wide slit to capture cancer cells bound to 3 µm beads. Apart from a higher purity and recovery rate, the slit design allows for simplified fabrication, easy cell imaging, less clogging, lower chamber pressure and, therefore, higher throughput. The beads were conjugated with anti-epithelial cell adhesion molecules (anti-EpCAM) to selectively bind to breast cancer cells (MCF-7) used to spike the whole blood. The diameter of the cell-bead construct was in average 23.1 µm, making them separable from other cells in the blood. As a result, the cancer cells were separated from 5 mL of whole blood with a purity of 52.0% and a recovery rate of 91.1%, and also we confirmed that the device can be applicable to clinical samples of human breast cancer patients. The simple design with microslit, by eliminating any high-aspect ratio features, is expected to reduce possible defects on the chip and, therefore, more suitable for mass production without false separation outputs.


Subject(s)
Antigens, Neoplasm/blood , Breast Neoplasms/blood , Microfluidic Analytical Techniques , Neoplastic Cells, Circulating , Breast Neoplasms/genetics , Female , Humans , MCF-7 Cells , Microspheres , Precancerous Conditions/blood , Precancerous Conditions/genetics
9.
Micromachines (Basel) ; 10(8)2019 Aug 05.
Article in English | MEDLINE | ID: mdl-31387332

ABSTRACT

It is my great pleasure to present to you this first volume of 13 papers on the subject of Microfluidics for Cells and other Organisms [...].

10.
Anal Chem ; 90(21): 12909-12916, 2018 11 06.
Article in English | MEDLINE | ID: mdl-30285432

ABSTRACT

Cells were separated with the aid of a multistep spiral fractionation device, utilizing hydrodynamic forces in a spiral tubing. The spiral was fabricated using "off-the-shelf" microbore tubing, allowing for cheap and fast prototyping to achieve optimal cell separation. As a first step, a model system with 20 and 40 µm beads was used to demonstrate the effectiveness of the multistep separation device. With an initial purity of 5%, a separation purity of 83% was achieved after a two-step separation with the addition of 0.1% polyethylene glycol (PEG)-8000. Next, doxorubicin-resistant polyploid giant breast cancer cells (MDA-MB-231) were separated from doxorubicin-sensitive monoploid small breast cancer cells in the same fashion as the beads, resulting in a purity of around 40%, while maintaining a cell viability of more than 90%. Combined with basic cell analytical methods, the hydrodynamic separation principle of the device could be envisaged to be useful for a variety of cell fractionation needs in cell biology and in clinical applications.

11.
Bioengineering (Basel) ; 5(2)2018 Apr 08.
Article in English | MEDLINE | ID: mdl-29642502

ABSTRACT

We have developed a microfluidic-based culture chip to simulate cancer cell migration and invasion across the basement membrane. In this microfluidic chip, a 3D microenvironment is engineered to culture metastatic breast cancer cells (MX1) in a 3D tumor model. A chemo-attractant was incorporated to stimulate motility across the membrane. We validated the usefulness of the chip by tracking the motilities of the cancer cells in the system, showing them to be migrating or invading (akin to metastasis). It is shown that our system can monitor cell migration in real time, as compare to Boyden chambers, for example. Thus, the chip will be of interest to the drug-screening community as it can potentially be used to monitor the behavior of cancer cell motility, and, therefore, metastasis, in the presence of anti-cancer drugs.

12.
Regen Med ; 13(2): 233-248, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29557299

ABSTRACT

Microfabrication and microfluidics contribute to the research of cellular functions of cells and their interaction with their environment. Previously, it has been shown that microfluidics can contribute to the isolation, selection, characterization and migration of cells. This review aims to provide stem cell researchers with a toolkit of microtechnology (mT) instruments for elucidating complex stem cells functions which are challenging to decipher with traditional assays and animal models. These microdevices are able to investigate about the differentiation and niche interaction, stem cells transcriptomics, therapeutic functions and the capture of their secreted microvesicles. In conclusion, microtechnology will allow a more realistic assessment of stem cells properties, driving and accelerating the translation of regenerative medicine approaches to the clinic.

13.
Anal Chem ; 90(4): 2534-2541, 2018 02 20.
Article in English | MEDLINE | ID: mdl-29365265

ABSTRACT

As paper-based diagnostics has become predominantly driven by more advanced microfluidic technology, many of the research efforts are still focused on developing reliable and versatile fluidic control devices, apart from improving sensitivity and reproducibility. In this work, we introduce a novel and robust paper fluidic control system enabling versatile fluidic control. The system comprises a linear push-pull solenoid and an Arduino Uno microcontroller. The precisely controlled pressure exerted on the paper stops the flow. We first determined the stroke distance of the solenoid to obtain a constant pressure while examining the fluidic time delay as a function of the pressure. Results showed that strips of grade 1 chromatography paper had superior reproducibility in fluid transport. Next, we characterized the reproducibility of the fluidic velocity which depends on the type and grade of paper used. As such, we were able to control the flow velocity on the paper and also achieve a complete stop of flow with a pressure over 2.0 MPa. Notably, after the actuation of the pressure driven valve (PDV), the previously pressed area regained its original flow properties. This means that, even on a previously pressed area, multiple valve operations can be successfully conducted. To the best of our knowledge, this is the first demonstration of an active and repetitive valve operation in paper microfluidics. As a proof of concept, we have chosen to perform a multistep detection system in the form of an enzyme-linked immunosorbent assay with mouse IgG as the target analyte.

14.
Biofabrication ; 9(2): 025023, 2017 May 26.
Article in English | MEDLINE | ID: mdl-28485301

ABSTRACT

Mechatronic design is an engineering methodology for conceiving, configuring and optimising the design of a technical device or product to the needs and requirements of the final user. In this article, we show how the basic principles of this methodology can be exploited for in vitro cell cultures-often referred to as organ-on-a-chip devices. Due to the key role of the biological cells, we have introduced the term bio-mechatronic design, to highlight the complexity of designing a system that should integrate biology, mechanics and electronics in the same device structure. The strength of the mechatronic design is to match the needs of the potential users to a systematic evaluation of overall functional design alternative. It may be especially attractive for organs-on-chips where biological constituents such as cells and tissues in 3D settings and in a fluidic environment should be compared, screened and selected. Through this approach, design solutions ranked to customer needs are generated according to specified criteria, thereby defining the key constraints of the fabrication. As an example, the bio-mechatronic methodology is applied to a liver-on-a-chip based on information extrapolated from previous theoretical and experimental knowledge. It is concluded that the methodology can generate new fabrication solutions for devices, as well as efficient guidelines for refining the design and fabrication of many of today's organ-on-a-chip devices.


Subject(s)
Biomimetics/methods , Lab-On-A-Chip Devices , Animals , Cell Culture Techniques , Equipment Design , Humans , Liver/physiology , Microfluidics
15.
Biofabrication ; 9(1): 015021, 2017 Feb 21.
Article in English | MEDLINE | ID: mdl-28222044

ABSTRACT

The endocrine system is a collection of glands producing hormones which, among others, regulates metabolism, growth and development. One important group of endocrine diseases is diabetes, which is caused by a deficiency or diminished effectiveness of endogenous insulin. By using a microfluidic perfused 3D cell-culture chip, we developed an 'endocrine system on chip' to potentially be able to screen drugs for the treatment of diabetes by measuring insulin release over time. Insulin-secreting ß-cells are located in the pancreas, while L-cells, located in the small intestines, stimulate insulin secretion. Thus, we constructed a co-culture of intestinal-pancreatic cells to measure the effect of glucose on the production of glucagon-like peptide-1 (GLP-1) from the L-cell line (GLUTag) and insulin from the pancreatic ß-cell line (INS-1). After three days of culture, both cell lines formed aggregates, exhibited 3D cell morphology, and showed good viability (>95%). We separately measured the dynamic profile of GLP-1 and insulin release at glucose concentrations of 0.5 and 20 mM, as well as the combined effect of GLP-1 on insulin production at these glucose concentrations. In response to glucose stimuli, GLUTag and INS-1 cells produced higher amounts of GLP-1 and insulin, respectively, compared to a static 2D cell culture. INS-1 combined with GLUTag cells exhibited an even higher insulin production in response to glucose stimulation. At higher glucose concentrations, the diabetes model on chip showed faster saturation of the insulin level. Our results suggest that the endocrine system developed in this study is a useful tool for observing dynamical changes in endocrine hormones (GLP-1 and insulin) in a glucose-dependent environment. Moreover, it can potentially be used to screen GLP-1 analogues and natural insulin and GLP-1 stimulants for diabetes treatment.


Subject(s)
Glucagon-Like Peptide 1/metabolism , Insulin/metabolism , Lab-On-A-Chip Devices , Models, Biological , Actins/metabolism , Animals , Cell Culture Techniques , Cell Line , Coculture Techniques , Diabetes Mellitus, Experimental/metabolism , Diabetes Mellitus, Experimental/pathology , Glucose/pharmacology , Insulin Secretion , Insulin-Secreting Cells/cytology , Insulin-Secreting Cells/drug effects , Insulin-Secreting Cells/metabolism , Microscopy, Confocal , Rats
16.
Nano Lett ; 14(8): 4257-62, 2014 Aug 13.
Article in English | MEDLINE | ID: mdl-24998447

ABSTRACT

The combination of micropillar array technology to measure cellular traction forces with super-resolution imaging allowed us to obtain cellular traction force maps and simultaneously zoom in on individual focal adhesions with single-molecule accuracy. We achieved a force detection precision of 500 pN simultaneously with a mean single-molecule localization precision of 30 nm. Key to the achievement was a two-step etching process that provided an integrated spacer next to the micropillar array that permitted stable and reproducible observation of cells on micropillars within the short working distance of a high-magnification, high numerical aperture objective. In turn, we used the technology to characterize the super-resolved structure of focal adhesions during force exertion. Live-cell imaging on MCF-7 cells demonstrated the applicability of the inverted configuration of the micropillar arrays to dynamics measurements. Forces emanated from a molecular base that was localized on top of the micropillars. What appeared as a single adhesion in conventional microscopy were in fact multiple elongated adhesions emanating from only a small fraction of the adhesion on the micropillar surface. Focal adhesions were elongated in the direction of local cellular force exertion with structural features of 100-280 nm in 3T3 Fibroblasts and MCF-7 cells. The combined measure of nanoscale architecture and force exerted shows a high level of stress accumulation at a single site of adhesion.

17.
Biosens Bioelectron ; 57: 1-9, 2014 Jul 15.
Article in English | MEDLINE | ID: mdl-24534574

ABSTRACT

Protein kinases control cellular functions by regulating protein phosphorylation. Monitoring protein kinase activity is essential for medical diagnosis and drug screening. Here, we present a novel microfluidic device for performing simple and versatile protein kinase assays, which utilizes a microbead-based chemosensor. An automatic mix-and-measure technique was achieved using integrated pneumatic valves. After mixing each reagent for the kinase assay, the mixture was transferred to the sensing chamber. Then, phosphorylated and fluorescence-labeled peptides were captured and detected by the chemosensor. A fluorescence signal was observed depending on the presence of the kinase. Furthermore, activities of various kinases in the cell lysate and the inhibitory effect of specific chemicals on the kinases were monitored. These results indicate that chemosensor-based microfluidic chips can be developed as a versatile kinase assay system.


Subject(s)
Biosensing Techniques/instrumentation , Microfluidic Analytical Techniques/instrumentation , Protein Kinases/metabolism , Enzyme Assays/instrumentation , Equipment Design , HeLa Cells , Humans , Peptides/metabolism , Phosphorylation
18.
Sci Rep ; 3: 3247, 2013 Nov 27.
Article in English | MEDLINE | ID: mdl-24284409

ABSTRACT

We probe C. elegans mechanosensation using a microfabricated platform where worms encounter a linear array of asymmetric funnel-like barriers. We found that sensing of and moving along barriers require different sets of neurons located at different parts of the animal. Wild-type worms sense and move along the barrier walls, leading to their accumulation in one side of the barriers due to the barriers' asymmetric shape. However, mec-4 and mec-10 mutants deficient in touch sensory neurons in the body exhibited reversal movements at the walls, leading to no accumulation in either side of the barriers. In contrast, osm-9 mutants deficient in touch sensory neurons in the nose, moved along the barrier walls. Thus, touch sensory neurons ALM and AVM in the body are required for C. elegans to sense and move along obstacles, whereas the ASH and FLP neurons in the nose are required only for sensing of but not moving along obstacles.


Subject(s)
Caenorhabditis elegans/physiology , Sensory Receptor Cells/metabolism , Animals , Animals, Genetically Modified/physiology , Behavior, Animal/physiology , Caenorhabditis elegans Proteins/genetics , Caenorhabditis elegans Proteins/metabolism , Membrane Proteins/genetics , Membrane Proteins/metabolism , Mutation , Nerve Tissue Proteins/genetics , Nerve Tissue Proteins/metabolism , TRPV Cation Channels/genetics , TRPV Cation Channels/metabolism
19.
Biotechnol Bioeng ; 110(6): 1663-73, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23280535

ABSTRACT

In vitro drug testing requires long-term maintenance of hepatocyte liver specific functions. Hepatocytes cultured at a higher seeding density in a sandwich configuration exhibit an increased level of liver specific functions when compared to low density cultures due to the better cell to cell contacts that promote long term maintenance of polarity and liver specific functions. However, culturing hepatocytes at high seeding densities in a standard 24-well plate poses problems in terms of the mass transport of nutrients and oxygen to the cells. In view of this drawback, we have developed a polydimethylsiloxane (PDMS) bioreactor that was able to maintain the long-term liver specific functions of a hepatocyte sandwich culture at a high seeding density. The bioreactor was fabricated with PDMS, an oxygen permeable material, which allowed direct oxygenation and perfusion to take place simultaneously. The mass transport of oxygen and the level of shear stress acting on the cells were analyzed by computational fluid dynamics (CFD). The combination of both direct oxygenation and perfusion has a synergistic effect on the liver specific function of a high density hepatocyte sandwich culture over a period of 9 days.


Subject(s)
Cell Culture Techniques/instrumentation , Cell Culture Techniques/methods , Dimethylpolysiloxanes/chemistry , Hepatocytes/cytology , Albumins/analysis , Albumins/metabolism , Analysis of Variance , Animals , Bioreactors , Diffusion , Equipment Design , Male , Microfluidics , Oxygen/metabolism , Rats , Rats, Wistar , Toxicity Tests
20.
Lab Chip ; 12(10): 1841-8, 2012 Apr 24.
Article in English | MEDLINE | ID: mdl-22441410

ABSTRACT

Biomolecules inside a microfluidic system can be used to solve computational problems, such as theorem proving, which is an important class of logical reasoning problems. In this article, the Boolean variables (literals) were represented using single-stranded DNA molecules, and theorem proving was performed by the hybridization and ligation of these variables into a double-stranded "solution" DNA. Then, a novel sequential reaction mixing method in a microfluidic chip was designed to solve a theorem proving problem, where a reaction loop and three additional chambers were integrated and controlled by pneumatic valves. DNA hybridization, ligation, toehold-mediated DNA strand displacement, exonuclease I digestion, and fluorescence detection of the double-stranded DNA were sequentially performed using this platform. Depending on the computational result, detection of the correct answer was demonstrated based on the presence of a fluorescence signal. This result is the first demonstration that microfluidics can be used to facilitate DNA-based logical inference.


Subject(s)
Computers, Molecular , DNA, Single-Stranded/chemistry , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Models, Chemical , Carbocyanines/chemistry , Equipment Design , Fluorescent Dyes/chemistry , Logic , Spectrometry, Fluorescence/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...