Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Eur Heart J Digit Health ; 5(2): 183-191, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38505481

ABSTRACT

Aims: Many portable electrocardiogram (ECG) devices have been developed to monitor patients at home, but the majority of these devices are single lead and only intended for rhythm disorders. We developed the miniECG, a smartphone-sized portable device with four dry electrodes capable of recording a high-quality multi-lead ECG by placing the device on the chest. The aim of our study was to investigate the ability of the miniECG to detect occlusive myocardial infarction (OMI) in patients with chest pain. Methods and results: Patients presenting with acute chest pain at the emergency department of the University Medical Center Utrecht or Meander Medical Center, between May 2021 and February 2022, were included in the study. The clinical 12-lead ECG and the miniECG before coronary intervention were recorded. The recordings were evaluated by cardiologists and compared the outcome of the coronary angiography, if performed. A total of 369 patients were measured with the miniECG, 46 of whom had OMI. The miniECG detected OMI with a sensitivity and specificity of 65 and 92%, compared with 83 and 90% for the 12-lead ECG. Sensitivity of the miniECG was similar for different culprit vessels. Conclusion: The miniECG can record a multi-lead ECG and rule-in ST-segment deviation in patients with occluded or near-occluded coronary arteries from different culprit vessels without many false alarms. Further research is required to add automated analysis to the recordings and to show feasibility to use the miniECG by patients at home.

2.
Heart Rhythm ; 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38403235

ABSTRACT

BACKGROUND: Phospholamban (PLN) p.(Arg14del) variant carriers are at risk for development of malignant ventricular arrhythmia (MVA). Accurate risk stratification allows timely implantation of intracardiac defibrillators and is currently performed with a multimodality prediction model. OBJECTIVE: This study aimed to investigate whether an explainable deep learning-based approach allows risk prediction with only electrocardiogram (ECG) data. METHODS: A total of 679 PLN p.(Arg14del) carriers without MVA at baseline were identified. A deep learning-based variational auto-encoder, trained on 1.1 million ECGs, was used to convert the 12-lead baseline ECG into its FactorECG, a compressed version of the ECG that summarizes it into 32 explainable factors. Prediction models were developed by Cox regression. RESULTS: The deep learning-based ECG-only approach was able to predict MVA with a C statistic of 0.79 (95% CI, 0.76-0.83), comparable to the current prediction model (C statistic, 0.83 [95% CI, 0.79-0.88]; P = .054) and outperforming a model based on conventional ECG parameters (low-voltage ECG and negative T waves; C statistic, 0.65 [95% CI, 0.58-0.73]; P < .001). Clinical simulations showed that a 2-step approach, with ECG-only screening followed by a full workup, resulted in 60% less additional diagnostics while outperforming the multimodal prediction model in all patients. A visualization tool was created to provide interactive visualizations (https://pln.ecgx.ai). CONCLUSION: Our deep learning-based algorithm based on ECG data only accurately predicts the occurrence of MVA in PLN p.(Arg14del) carriers, enabling more efficient stratification of patients who need additional diagnostic testing and follow-up.

3.
Eur Heart J Digit Health ; 5(1): 89-96, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38264701

ABSTRACT

Aims: Expert knowledge to correctly interpret electrocardiograms (ECGs) is not always readily available. An artificial intelligence (AI)-based triage algorithm (DELTAnet), able to support physicians in ECG prioritization, could help reduce current logistic burden of overreading ECGs and improve time to treatment for acute and life-threatening disorders. However, the effect of clinical implementation of such AI algorithms is rarely investigated. Methods and results: Adult patients at non-cardiology departments who underwent ECG testing as a part of routine clinical care were included in this prospective cohort study. DELTAnet was used to classify 12-lead ECGs into one of the following triage classes: normal, abnormal not acute, subacute, and acute. Performance was compared with triage classes based on the final clinical diagnosis. Moreover, the associations between predicted classes and clinical outcomes were investigated. A total of 1061 patients and ECGs were included. Performance was good with a mean concordance statistic of 0.96 (95% confidence interval 0.95-0.97) when comparing DELTAnet with the clinical triage classes. Moreover, zero ECGs that required a change in policy or referral to the cardiologist were missed and there was a limited number of cases predicted as acute that did not require follow-up (2.6%). Conclusion: This study is the first to prospectively investigate the impact of clinical implementation of an ECG-based AI triage algorithm. It shows that DELTAnet is efficacious and safe to be used in clinical practice for triage of 12-lead ECGs in non-cardiology hospital departments.

4.
Int J Cardiovasc Imaging ; 39(11): 2149-2161, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37566298

ABSTRACT

Echocardiographic deformation curves provide detailed information on myocardial function. Deep neural networks (DNNs) may enable automated detection of disease features in deformation curves, and improve the clinical assessment of these curves. We aimed to investigate whether an explainable DNN-based pipeline can be used to detect and visualize disease features in echocardiographic deformation curves of phospholamban (PLN) p.Arg14del variant carriers. A DNN was trained to discriminate PLN variant carriers (n = 278) from control subjects (n = 621) using raw deformation curves obtained by 2D-speckle tracking in the longitudinal axis. A visualization technique was used to identify the parts of these curves that were used by the DNN for classification. The PLN variant carriers were clustered according to the output of the visualization technique. The DNN showed excellent discriminatory performance (C-statistic 0.93 [95% CI 0.87-0.97]). We identified four clusters with PLN-associated disease features in the deformation curves. Two clusters showed previously described features: apical post-systolic shortening and reduced systolic strain. The two other clusters revealed novel features, both reflecting delayed relaxation. Additionally, a fifth cluster was identified containing variant carriers without disease features in the deformation curves, who were classified as controls by the DNN. This latter cluster had a very benign disease course regarding development of ventricular arrhythmias. Applying an explainable DNN-based pipeline to myocardial deformation curves enables automated detection and visualization of disease features. In PLN variant carriers, we discovered novel disease features which may improve individual risk stratification. Applying this approach to other diseases will further expand our knowledge on disease-specific deformation patterns. Overview of the deep neural network-based pipeline for feature detection in myocardial deformation curves. Firstly, phospholamban (PLN) p.Arg14del variant carriers and controls were selected and a deep neural network (DNN) was trained to detect the PLN variant carriers. Subsequently, a clustering-based approach was performed on the attention maps of the DNN, which revealed 4 distinct phenotypes of PLN variant carriers with different prognoses. Moreover, a cluster without features and a benign prognosis was detected.


Subject(s)
Calcium-Binding Proteins , Myocardium , Humans , Predictive Value of Tests , Myocardium/pathology , Calcium-Binding Proteins/genetics , Neural Networks, Computer
5.
JMIR Cardio ; 7: e44003, 2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37418308

ABSTRACT

BACKGROUND: Electrocardiograms (ECGs) are used by physicians to record, monitor, and diagnose the electrical activity of the heart. Recent technological advances have allowed ECG devices to move out of the clinic and into the home environment. There is a great variety of mobile ECG devices with the capabilities to be used in home environments. OBJECTIVE: This scoping review aimed to provide a comprehensive overview of the current landscape of mobile ECG devices, including the technology used, intended clinical use, and available clinical evidence. METHODS: We conducted a scoping review to identify studies concerning mobile ECG devices in the electronic database PubMed. Secondarily, an internet search was performed to identify other ECG devices available in the market. We summarized the devices' technical information and usability characteristics based on manufacturer data such as datasheets and user manuals. For each device, we searched for clinical evidence on the capabilities to record heart disorders by performing individual searches in PubMed and ClinicalTrials.gov, as well as the Food and Drug Administration (FDA) 510(k) Premarket Notification and De Novo databases. RESULTS: From the PubMed database and internet search, we identified 58 ECG devices with available manufacturer information. Technical characteristics such as shape, number of electrodes, and signal processing influence the capabilities of the devices to record cardiac disorders. Of the 58 devices, only 26 (45%) had clinical evidence available regarding their ability to detect heart disorders such as rhythm disorders, more specifically atrial fibrillation. CONCLUSIONS: ECG devices available in the market are mainly intended to be used for the detection of arrhythmias. No devices are intended to be used for the detection of other cardiac disorders. Technical and design characteristics influence the intended use of the devices and use environments. For mobile ECG devices to be intended to detect other cardiac disorders, challenges regarding signal processing and sensor characteristics should be solved to increase their detection capabilities. Devices recently released include the use of other sensors on ECG devices to increase their detection capabilities.

6.
Eur J Neurol ; 30(9): 2611-2619, 2023 09.
Article in English | MEDLINE | ID: mdl-37254942

ABSTRACT

BACKGROUND AND PURPOSE: A heart age biomarker has been developed using deep neural networks applied to electrocardiograms. Whether this biomarker is associated with cognitive function was investigated. METHODS: Using 12-lead electrocardiograms, heart age was estimated for a population-based sample (N = 7779, age 40-85 years, 45.3% men). Associations between heart delta age (HDA) and cognitive test scores were studied adjusted for cardiovascular risk factors. In addition, the relationship between HDA, brain delta age (BDA) and cognitive test scores was investigated in mediation analysis. RESULTS: Significant associations between HDA and the Word test, Digit Symbol Coding Test and tapping test scores were found. HDA was correlated with BDA (Pearson's r = 0.12, p = 0.0001). Moreover, 13% (95% confidence interval 3-36) of the HDA effect on the tapping test score was mediated through BDA. DISCUSSION: Heart delta age, representing the cumulative effects of life-long exposures, was associated with brain age. HDA was associated with cognitive function that was minimally explained through BDA.


Subject(s)
Brain , Cognition Disorders , Male , Humans , Adult , Middle Aged , Aged , Aged, 80 and over , Female , Cognition , Heart , Cognition Disorders/psychology , Electrocardiography , Neuropsychological Tests
7.
Eur Heart J ; 44(8): 680-692, 2023 02 21.
Article in English | MEDLINE | ID: mdl-36342291

ABSTRACT

AIMS: This study aims to identify and visualize electrocardiogram (ECG) features using an explainable deep learning-based algorithm to predict cardiac resynchronization therapy (CRT) outcome. Its performance is compared with current guideline ECG criteria and QRSAREA. METHODS AND RESULTS: A deep learning algorithm, trained on 1.1 million ECGs from 251 473 patients, was used to compress the median beat ECG, thereby summarizing most ECG features into only 21 explainable factors (FactorECG). Pre-implantation ECGs of 1306 CRT patients from three academic centres were converted into their respective FactorECG. FactorECG predicted the combined clinical endpoint of death, left ventricular assist device, or heart transplantation [c-statistic 0.69, 95% confidence interval (CI) 0.66-0.72], significantly outperforming QRSAREA and guideline ECG criteria [c-statistic 0.61 (95% CI 0.58-0.64) and 0.57 (95% CI 0.54-0.60), P < 0.001 for both]. The addition of 13 clinical variables was of limited added value for the FactorECG model when compared with QRSAREA (Δ c-statistic 0.03 vs. 0.10). FactorECG identified inferolateral T-wave inversion, smaller right precordial S- and T-wave amplitude, ventricular rate, and increased PR interval and P-wave duration to be important predictors for poor outcome. An online visualization tool was created to provide interactive visualizations (https://crt.ecgx.ai). CONCLUSION: Requiring only a standard 12-lead ECG, FactorECG held superior discriminative ability for the prediction of clinical outcome when compared with guideline criteria and QRSAREA, without requiring additional clinical variables. End-to-end automated visualization of ECG features allows for an explainable algorithm, which may facilitate rapid uptake of this personalized decision-making tool in CRT.


Subject(s)
Cardiac Resynchronization Therapy , Deep Learning , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Treatment Outcome , Electrocardiography , Arrhythmias, Cardiac/therapy
8.
J Am Heart Assoc ; 11(14): e025473, 2022 07 19.
Article in English | MEDLINE | ID: mdl-35861818

ABSTRACT

Background Interatrial block (IAB) has been associated with supraventricular arrhythmias and stroke, and even with sudden cardiac death in the general population. Whether IAB is associated with life-threatening arrhythmias (LTA) and sudden cardiac death in dilated cardiomyopathy (DCM) remains unknown. This study aimed to determine the association between IAB and LTA in ambulant patients with DCM. Methods and Results A derivation cohort (Maastricht Dilated Cardiomyopathy Registry; N=469) and an external validation cohort (Utrecht Cardiomyopathy Cohort; N=321) were used for this study. The presence of IAB (P-wave duration>120 milliseconds) or atrial fibrillation (AF) was determined using digital calipers by physicians blinded to the study data. In the derivation cohort, IAB and AF were present in 291 (62%) and 70 (15%) patients with DCM, respectively. LTA (defined as sudden cardiac death, justified shock from implantable cardioverter-defibrillator or anti-tachypacing, or hemodynamic unstable ventricular fibrillation/tachycardia) occurred in 49 patients (3 with no IAB, 35 with IAB, and 11 patients with AF, respectively; median follow-up, 4.4 years [2.1; 7.4]). The LTA-free survival distribution significantly differed between IAB or AF versus no IAB (both P<0.01), but not between IAB versus AF (P=0.999). This association remained statistically significant in the multivariable model (IAB: HR, 4.8 (1.4-16.1), P=0.013; AF: HR, 6.4 (1.7-24.0), P=0.007). In the external validation cohort, the survival distribution was also significantly worse for IAB or AF versus no IAB (P=0.037; P=0.005), but not for IAB versus AF (P=0.836). Conclusions IAB is an easy to assess, widely applicable marker associated with LTA in DCM. IAB and AF seem to confer similar risk of LTA. Further research on IAB in DCM, and on the management of IAB in DCM is warranted.


Subject(s)
Atrial Fibrillation , Cardiomyopathy, Dilated , Atrial Fibrillation/epidemiology , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/diagnosis , Cardiomyopathy, Dilated/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Electrocardiography/methods , Humans , Interatrial Block/complications , Interatrial Block/diagnosis
9.
Europace ; 24(10): 1645-1654, 2022 10 13.
Article in English | MEDLINE | ID: mdl-35762524

ABSTRACT

AIMS: While electrocardiogram (ECG) characteristics have been associated with life-threatening ventricular arrhythmias (LTVA) in dilated cardiomyopathy (DCM), they typically rely on human-derived parameters. Deep neural networks (DNNs) can discover complex ECG patterns, but the interpretation is hampered by their 'black-box' characteristics. We aimed to detect DCM patients at risk of LTVA using an inherently explainable DNN. METHODS AND RESULTS: In this two-phase study, we first developed a variational autoencoder DNN on more than 1 million 12-lead median beat ECGs, compressing the ECG into 21 different factors (F): FactorECG. Next, we used two cohorts with a combined total of 695 DCM patients and entered these factors in a Cox regression for the composite LTVA outcome, which was defined as sudden cardiac arrest, spontaneous sustained ventricular tachycardia, or implantable cardioverter-defibrillator treated ventricular arrhythmia. Most patients were male (n = 442, 64%) with a median age of 54 years [interquartile range (IQR) 44-62], and median left ventricular ejection fraction of 30% (IQR 23-39). A total of 115 patients (16.5%) reached the study outcome. Factors F8 (prolonged PR-interval and P-wave duration, P < 0.005), F15 (reduced P-wave height, P = 0.04), F25 (increased right bundle branch delay, P = 0.02), F27 (P-wave axis P < 0.005), and F32 (reduced QRS-T voltages P = 0.03) were significantly associated with LTVA. CONCLUSION: Inherently explainable DNNs can detect patients at risk of LTVA which is mainly driven by P-wave abnormalities.


Subject(s)
Cardiomyopathy, Dilated , Defibrillators, Implantable , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/diagnosis , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electrocardiography/methods , Female , Humans , Male , Middle Aged , Neural Networks, Computer , Risk Factors , Stroke Volume , Ventricular Function, Left/physiology
11.
Eur Heart J Digit Health ; 3(3): 390-404, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36712164

ABSTRACT

Aims: Deep neural networks (DNNs) perform excellently in interpreting electrocardiograms (ECGs), both for conventional ECG interpretation and for novel applications such as detection of reduced ejection fraction (EF). Despite these promising developments, implementation is hampered by the lack of trustworthy techniques to explain the algorithms to clinicians. Especially, currently employed heatmap-based methods have shown to be inaccurate. Methods and results: We present a novel pipeline consisting of a variational auto-encoder (VAE) to learn the underlying factors of variation of the median beat ECG morphology (the FactorECG), which are subsequently used in common and interpretable prediction models. As the ECG factors can be made explainable by generating and visualizing ECGs on both the model and individual level, the pipeline provides improved explainability over heatmap-based methods. By training on a database with 1.1 million ECGs, the VAE can compress the ECG into 21 generative ECG factors, most of which are associated with physiologically valid underlying processes. Performance of the explainable pipeline was similar to 'black box' DNNs in conventional ECG interpretation [area under the receiver operating curve (AUROC) 0.94 vs. 0.96], detection of reduced EF (AUROC 0.90 vs. 0.91), and prediction of 1-year mortality (AUROC 0.76 vs. 0.75). Contrary to the 'black box' DNNs, our pipeline provided explainability on which morphological ECG changes were important for prediction. Results were confirmed in a population-based external validation dataset. Conclusions: Future studies on DNNs for ECGs should employ pipelines that are explainable to facilitate clinical implementation by gaining confidence in artificial intelligence and making it possible to identify biased models.

12.
Eur Heart J Digit Health ; 3(2): 245-254, 2022 Jun.
Article in English | MEDLINE | ID: mdl-36713005

ABSTRACT

Aims: Incorporation of sex in study design can lead to discoveries in medical research. Deep neural networks (DNNs) accurately predict sex based on the electrocardiogram (ECG) and we hypothesized that misclassification of sex is an important predictor for mortality. Therefore, we first developed and validated a DNN that classified sex based on the ECG and investigated the outcome. Second, we studied ECG drivers of DNN-classified sex and mortality. Methods and results: A DNN was trained to classify sex based on 131 673 normal ECGs. The algorithm was validated on internal (68 500 ECGs) and external data sets (3303 and 4457 ECGs). The survival of sex (mis)classified groups was investigated using time-to-event analysis and sex-stratified mediation analysis of ECG features. The DNN successfully distinguished female from male ECGs {internal validation: area under the curve (AUC) 0.96 [95% confidence interval (CI): 0.96, 0.97]; external validations: AUC 0.89 (95% CI: 0.88, 0.90), 0.94 (95% CI: 0.93, 0.94)}. Sex-misclassified individuals (11%) had a 1.4 times higher mortality risk compared with correctly classified peers. The ventricular rate was the strongest mediating ECG variable (41%, 95% CI: 31%, 56%) in males, while the maximum amplitude of the ST segment was strongest in females (18%, 95% CI: 11%, 39%). Short QRS duration was associated with higher mortality risk. Conclusion: Deep neural networks accurately classify sex based on ECGs. While the proportion of ECG-based sex misclassifications is low, it is an interesting biomarker. Investigation of the causal pathway between misclassification and mortality uncovered new ECG features that might be associated with mortality. Increased emphasis on sex as a biological variable in artificial intelligence is warranted.

14.
Circ Arrhythm Electrophysiol ; 14(2): e009056, 2021 02.
Article in English | MEDLINE | ID: mdl-33401921

ABSTRACT

BACKGROUND: ECG interpretation requires expertise and is mostly based on physician recognition of specific patterns, which may be challenging in rare cardiac diseases. Deep neural networks (DNNs) can discover complex features in ECGs and may facilitate the detection of novel features which possibly play a pathophysiological role in relatively unknown diseases. Using a cohort of PLN (phospholamban) p.Arg14del mutation carriers, we aimed to investigate whether a novel DNN-based approach can identify established ECG features, but moreover, we aimed to expand our knowledge on novel ECG features in these patients. METHODS: A DNN was developed on 12-lead median beat ECGs of 69 patients and 1380 matched controls and independently evaluated on 17 patients and 340 controls. Differentiating features were visualized using Guided Gradient Class Activation Mapping++. Novel ECG features were tested for their diagnostic value by adding them to a logistic regression model including established ECG features. RESULTS: The DNN showed excellent discriminatory performance with a c-statistic of 0.95 (95% CI, 0.91-0.99) and sensitivity and specificity of 0.82 and 0.93, respectively. Visualizations revealed established ECG features (low QRS voltages and T-wave inversions), specified these features (eg, R- and T-wave attenuation in V2/V3) and identified novel PLN-specific ECG features (eg, increased PR-duration). The logistic regression baseline model improved significantly when augmented with the identified features (P<0.001). CONCLUSIONS: A DNN-based feature detection approach was able to discover and visualize disease-specific ECG features in PLN mutation carriers and revealed yet unidentified features. This novel approach may help advance diagnostic capabilities in daily practice.


Subject(s)
Calcium-Binding Proteins/genetics , DNA/genetics , Deep Learning , Electrocardiography , Heart Diseases/genetics , Mutation , Adult , Calcium-Binding Proteins/metabolism , DNA Mutational Analysis , Female , Heart Diseases/diagnosis , Heart Diseases/physiopathology , Humans , Male , Retrospective Studies
15.
Eur Heart J Digit Health ; 2(3): 401-415, 2021 Sep.
Article in English | MEDLINE | ID: mdl-36713602

ABSTRACT

Aims: Automated interpretation of electrocardiograms (ECGs) using deep neural networks (DNNs) has gained much attention recently. While the initial results have been encouraging, limited attention has been paid to whether such results can be trusted, which is paramount for their clinical implementation. This study aims to systematically investigate uncertainty estimation techniques for automated classification of ECGs using DNNs and to gain insight into its utility through a clinical simulation. Methods and results: On a total of 526 656 ECGs from three different datasets, six different methods for estimation of aleatoric and epistemic uncertainty were systematically investigated. The methods were evaluated based on ranking, calibration, and robustness against out-of-distribution data. Furthermore, a clinical simulation was performed where increasing uncertainty thresholds were applied to achieve a clinically acceptable performance. Finally, the correspondence between the uncertainty of ECGs and the lack of interpretational agreement between cardiologists was estimated. Results demonstrated the largest benefit when modelling both epistemic and aleatoric uncertainty. Notably, the combination of variational inference with Bayesian decomposition and ensemble with auxiliary output outperformed the other methods. The clinical simulation showed that the accuracy of the algorithm increased as uncertain predictions were referred to the physician. Moreover, high uncertainty in DNN-based ECG classification strongly corresponded with a lower diagnostic agreement in cardiologist's interpretation (P < 0.001). Conclusion: Uncertainty estimation is warranted in automated DNN-based ECG classification and its accurate estimation enables intermediate quality control in the clinical implementation of deep learning. This is an important step towards the clinical applicability of automated ECG diagnosis using DNNs.

16.
Arrhythm Electrophysiol Rev ; 9(3): 146-154, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33240510

ABSTRACT

The combination of big data and artificial intelligence (AI) is having an increasing impact on the field of electrophysiology. Algorithms are created to improve the automated diagnosis of clinical ECGs or ambulatory rhythm devices. Furthermore, the use of AI during invasive electrophysiological studies or combining several diagnostic modalities into AI algorithms to aid diagnostics are being investigated. However, the clinical performance and applicability of created algorithms are yet unknown. In this narrative review, opportunities and threats of AI in the field of electrophysiology are described, mainly focusing on ECGs. Current opportunities are discussed with their potential clinical benefits as well as the challenges. Challenges in data acquisition, model performance, (external) validity, clinical implementation, algorithm interpretation as well as the ethical aspects of AI research are discussed. This article aims to guide clinicians in the evaluation of new AI applications for electrophysiology before their clinical implementation.

17.
J Am Heart Assoc ; 9(10): e015138, 2020 05 18.
Article in English | MEDLINE | ID: mdl-32406296

ABSTRACT

BACKGROUND The correct interpretation of the ECG is pivotal for the accurate diagnosis of many cardiac abnormalities, and conventional computerized interpretation has not been able to reach physician-level accuracy in detecting (acute) cardiac abnormalities. This study aims to develop and validate a deep neural network for comprehensive automated ECG triage in daily practice. METHODS AND RESULTS We developed a 37-layer convolutional residual deep neural network on a data set of free-text physician-annotated 12-lead ECGs. The deep neural network was trained on a data set with 336.835 recordings from 142.040 patients and validated on an independent validation data set (n=984), annotated by a panel of 5 cardiologists electrophysiologists. The 12-lead ECGs were acquired in all noncardiology departments of the University Medical Center Utrecht. The algorithm learned to classify these ECGs into the following 4 triage categories: normal, abnormal not acute, subacute, and acute. Discriminative performance is presented with overall and category-specific concordance statistics, polytomous discrimination indexes, sensitivities, specificities, and positive and negative predictive values. The patients in the validation data set had a mean age of 60.4 years and 54.3% were men. The deep neural network showed excellent overall discrimination with an overall concordance statistic of 0.93 (95% CI, 0.92-0.95) and a polytomous discriminatory index of 0.83 (95% CI, 0.79-0.87). CONCLUSIONS This study demonstrates that an end-to-end deep neural network can be accurately trained on unstructured free-text physician annotations and used to consistently triage 12-lead ECGs. When further fine-tuned with other clinical outcomes and externally validated in clinical practice, the demonstrated deep learning-based ECG interpretation can potentially improve time to treatment and decrease healthcare burden.


Subject(s)
Deep Learning , Electrocardiography , Heart Diseases/diagnosis , Signal Processing, Computer-Assisted , Triage , Adolescent , Adult , Aged , Aged, 80 and over , Automation , Clinical Decision-Making , Female , Heart Diseases/physiopathology , Heart Diseases/therapy , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Young Adult
18.
BMC Med Res Methodol ; 19(1): 199, 2019 10 26.
Article in English | MEDLINE | ID: mdl-31655567

ABSTRACT

BACKGROUND: The incorporation of repeated measurements into multivariable prediction research may greatly enhance predictive performance. However, the methodological possibilities vary widely and a structured overview of the possible and utilized approaches lacks. Therefore, we [1] propose a structured framework for these approaches, [2] determine what methods are currently used to incorporate repeated measurements in prediction research in the critical care setting and, where possible, [3] assess the added discriminative value of incorporating repeated measurements. METHODS: The proposed framework consists of three domains: the observation window (static or dynamic), the processing of the raw data (raw data modelling, feature extraction and reduction) and the type of modelling. A systematic review was performed to identify studies which incorporate repeated measurements to predict (e.g. mortality) in the critical care setting. The within-study difference in c-statistics between models with versus without repeated measurements were obtained and pooled in a meta-analysis. RESULTS: From the 2618 studies found, 29 studies incorporated multiple repeated measurements. The annual number of studies with repeated measurements increased from 2.8/year (2000-2005) to 16.0/year (2016-2018). The majority of studies that incorporated repeated measurements for prediction research used a dynamic observation window, and extracted features directly from the data. Differences in c statistics ranged from - 0.048 to 0.217 in favour of models that utilize repeated measurements. CONCLUSIONS: Repeated measurements are increasingly common to predict events in the critical care domain, but their incorporation is lagging. A framework of possible approaches could aid researchers to optimize future prediction models.


Subject(s)
Critical Care/statistics & numerical data , Forecasting/methods , Data Collection , Data Mining , Humans , Research Design
SELECTION OF CITATIONS
SEARCH DETAIL
...