Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Cochrane Database Syst Rev ; 5: CD014715, 2024 05 09.
Article in English | MEDLINE | ID: mdl-38721874

ABSTRACT

BACKGROUND: Prenatal ultrasound is widely used to screen for structural anomalies before birth. While this is traditionally done in the second trimester, there is an increasing use of first-trimester ultrasound for early detection of lethal and certain severe structural anomalies. OBJECTIVES: To evaluate the diagnostic accuracy of ultrasound in detecting fetal structural anomalies before 14 and 24 weeks' gestation in low-risk and unselected pregnant women and to compare the current two main prenatal screening approaches: a single second-trimester scan (single-stage screening) and a first- and second-trimester scan combined (two-stage screening) in terms of anomaly detection before 24 weeks' gestation. SEARCH METHODS: We searched MEDLINE, EMBASE, Science Citation Index Expanded (Web of Science), Social Sciences Citation Index (Web of Science), Arts & Humanities Citation Index and Emerging Sources Citation Index (Web of Science) from 1 January 1997 to 22 July 2022. We limited our search to studies published after 1997 and excluded animal studies, reviews and case reports. No further restrictions were applied. We also screened reference lists and citing articles of each of the included studies. SELECTION CRITERIA: Studies were eligible if they included low-risk or unselected pregnant women undergoing a first- and/or second-trimester fetal anomaly scan, conducted at 11 to 14 or 18 to 24 weeks' gestation, respectively. The reference standard was detection of anomalies at birth or postmortem. DATA COLLECTION AND ANALYSIS: Two review authors independently undertook study selection, quality assessment (QUADAS-2), data extraction and evaluation of the certainty of evidence (GRADE approach). We used univariate random-effects logistic regression models for the meta-analysis of sensitivity and specificity. MAIN RESULTS: Eighty-seven studies covering 7,057,859 fetuses (including 25,202 with structural anomalies) were included. No study was deemed low risk across all QUADAS-2 domains. Main methodological concerns included risk of bias in the reference standard domain and risk of partial verification. Applicability concerns were common in studies evaluating first-trimester scans and two-stage screening in terms of patient selection due to frequent recruitment from single tertiary centres without exclusion of referrals. We reported ultrasound accuracy for fetal structural anomalies overall, by severity, affected organ system and for 46 specific anomalies. Detection rates varied widely across categories, with the highest estimates of sensitivity for thoracic and abdominal wall anomalies and the lowest for gastrointestinal anomalies across all tests. The summary sensitivity of a first-trimester scan was 37.5% for detection of structural anomalies overall (95% confidence interval (CI) 31.1 to 44.3; low-certainty evidence) and 91.3% for lethal anomalies (95% CI 83.9 to 95.5; moderate-certainty evidence), with an overall specificity of 99.9% (95% CI 99.9 to 100; low-certainty evidence). Two-stage screening had a combined sensitivity of 83.8% (95% CI 74.7 to 90.1; low-certainty evidence), while single-stage screening had a sensitivity of 50.5% (95% CI 38.5 to 62.4; very low-certainty evidence). The specificity of two-stage screening was 99.9% (95% CI 99.7 to 100; low-certainty evidence) and for single-stage screening, it was 99.8% (95% CI 99.2 to 100; moderate-certainty evidence). Indirect comparisons suggested superiority of two-stage screening across all analyses regarding sensitivity, with no significant difference in specificity. However, the certainty of the evidence is very low due to the absence of direct comparisons. AUTHORS' CONCLUSIONS: A first-trimester scan has the potential to detect lethal and certain severe anomalies with high accuracy before 14 weeks' gestation, despite its limited overall sensitivity. Conversely, two-stage screening shows high accuracy in detecting most fetal structural anomalies before 24 weeks' gestation with high sensitivity and specificity. In a hypothetical cohort of 100,000 fetuses, the first-trimester scan is expected to correctly identify 113 out of 124 fetuses with lethal anomalies (91.3%) and 665 out of 1776 fetuses with any anomaly (37.5%). However, 79 false-positive diagnoses are anticipated among 98,224 fetuses (0.08%). Two-stage screening is expected to correctly identify 1448 out of 1776 cases of structural anomalies overall (83.8%), with 118 false positives (0.1%). In contrast, single-stage screening is expected to correctly identify 896 out of 1776 cases before 24 weeks' gestation (50.5%), with 205 false-positive diagnoses (0.2%). This represents a difference of 592 fewer correct identifications and 88 more false positives compared to two-stage screening. However, it is crucial to acknowledge the uncertainty surrounding the additional benefits of two-stage versus single-stage screening, as there are no studies directly comparing them. Moreover, the evidence supporting the accuracy of first-trimester ultrasound and two-stage screening approaches primarily originates from studies conducted in single tertiary care facilities, which restricts the generalisability of the results of this meta-analysis to the broader population.


Subject(s)
Pregnancy Trimester, First , Pregnancy Trimester, Second , Ultrasonography, Prenatal , Female , Humans , Pregnancy , Bias , Congenital Abnormalities/diagnostic imaging , Sensitivity and Specificity , Ultrasonography, Prenatal/statistics & numerical data
2.
Br J Radiol ; 96(1145): 20220744, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-36802835

ABSTRACT

OBJECTIVES: Adult spleens show extensive morphological variation, with a reported prevalence of 40-98% clefts (also called notches or fissures) on the splenic surface and 10-30% accessory spleens at autopsy. It is hypothesised that both anatomical variants result from a complete or partial failure of multiple splenic primordia to fuse to the main body. According to this hypothesis, fusion of the spleen primordia is completed after birth and spleen morphological variations are often explained as stagnation of spleen development at the foetal stage. We tested this hypothesis by studying early spleen development in embryos, and compared foetal and adult spleen morphology. METHODS AND MATERIALS: We assessed 22 embryonic, 17 foetal and 90 adult spleens on the presence of clefts using histology, micro-CT and conventional post-mortem CT-scans, respectively. RESULTS: The spleen primordium was observed as a single mesenchymal condensation in all embryonic specimens. The number of clefts varied from 0 to 6 in foetuses, compared to 0-5 in adults. We found no correlation between foetal age and number of clefts (R2 = 0.004). The independent samples Kolmogorov-Smirnov test showed no significant difference in the total number of clefts between adult and foetal spleens (p = 0.068). CONCLUSION: We found no morphological evidence for a multifocal origin or a lobulated developmental stage of the human spleen. ADVANCES IN KNOWLEDGE: Our findings show that splenic morphology is highly variable, independent of developmental stage and age. We suggest to abandon the term "persistent foetal lobulation" and to regard splenic clefts, regardless of their number or location, as normal variants.


Subject(s)
Anatomic Variation , Spleen , Adult , Humans , Spleen/diagnostic imaging , Spleen/pathology , Autopsy , Gestational Age , X-Ray Microtomography
3.
J Clin Invest ; 131(5)2021 03 01.
Article in English | MEDLINE | ID: mdl-33645542

ABSTRACT

Congenital heart disease is the most common type of birth defect, accounting for one-third of all congenital anomalies. Using whole-exome sequencing of 2718 patients with congenital heart disease and a search in GeneMatcher, we identified 30 patients from 21 unrelated families of different ancestries with biallelic phospholipase D1 (PLD1) variants who presented predominantly with congenital cardiac valve defects. We also associated recessive PLD1 variants with isolated neonatal cardiomyopathy. Furthermore, we established that p.I668F is a founder variant among Ashkenazi Jews (allele frequency of ~2%) and describe the phenotypic spectrum of PLD1-associated congenital heart defects. PLD1 missense variants were overrepresented in regions of the protein critical for catalytic activity, and, correspondingly, we observed a strong reduction in enzymatic activity for most of the mutant proteins in an enzymatic assay. Finally, we demonstrate that PLD1 inhibition decreased endothelial-mesenchymal transition, an established pivotal early step in valvulogenesis. In conclusion, our study provides a more detailed understanding of disease mechanisms and phenotypic expression associated with PLD1 loss of function.


Subject(s)
Alleles , Heart Defects, Congenital , Heart Valve Diseases , Loss of Function Mutation , Phospholipase D , Female , Heart Defects, Congenital/enzymology , Heart Defects, Congenital/genetics , Heart Valve Diseases/enzymology , Heart Valve Diseases/genetics , Humans , Male , Phospholipase D/genetics , Phospholipase D/metabolism
4.
Biomol Detect Quantif ; 14: 7-18, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29255685

ABSTRACT

Quantitative PCR allows the precise measurement of DNA concentrations and is generally considered to be straightforward and trouble free. However, a survey with 93 validated assays for genes in the Wnt-pathway showed that the amplification of nonspecific products occurs frequently and is unrelated to Cq or PCR efficiency values. Titration experiments showed that the occurrence of low and high melting temperature artifacts was shown to be determined by annealing temperature, primer concentration and cDNA input. To explore the range of input variations that occur in the normal use of the Cre assay these conditions were mimicked in a complete two-way design of template -plasmid DNA- and non-template -mouse cDNA- concentrations. These experiments showed that the frequency of the amplification of the correct product and the artifact, as well as the valid quantification of the correct product, depended on the concentration of the non-template cDNA. This finding questions the interpretation of dilution series in which template as well as non-template concentrations are simultaneously decreasing. Repetition of this cDNA concentration experiment with other templates revealed that exact reproduction qPCR experiments was affected by the time it takes to complete the pipetting of a qPCR plate. Long bench times were observed to lead to significantly more artifacts. However, the measurement of artifact-associated fluorescence can be avoided by inclusion of a small heating step after the elongation phase in the amplification protocol. Taken together, this trouble-shooting journey showed that reliability and reproducibility of qPCR experiments not only depends on standardization and reporting of the biochemistry and technical aspects but also on hitherto neglected factors as sample dilution and waiting times in the laboratory work flow.

SELECTION OF CITATIONS
SEARCH DETAIL
...