Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 67
Filter
Add more filters










Publication year range
2.
J Nucl Med ; 65(3): 481-484, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38124121

ABSTRACT

To elucidate potential benefits of the Auger-electron-emitting radionuclide 161Tb, we compared the preclinical performance of the gastrin-releasing peptide receptor antagonists RM2 (DOTA-Pip5-d-Phe6-Gln7-Trp8-Ala9-Val10-Gly11-His12-Sta13-Leu14-NH2) and AMTG (α-Me-Trp8-RM2), each labeled with both 177Lu and 161Tb. Methods: 161Tb/177Lu labeling (90°C, 5 min) and cell-based experiments (PC-3 cells) were performed. In vivo stability (30 min after injection) and biodistribution studies (1-72 h after injection) were performed on PC-3 tumor-bearing CB17-SCID mice. Results: Gastrin-releasing peptide receptor affinity was high for all compounds (half-maximal inhibitory concentration [nM]: [161Tb]Tb-RM2, 2.46 ± 0.16; [161Tb]Tb-AMTG, 2.16 ± 0.09; [177Lu]Lu-RM2, 3.45 ± 0.18; [177Lu]Lu-AMTG, 3.04 ± 0.08), and 75%-84% of cell-associated activity was receptor-bound. In vivo, both AMTG analogs displayed distinctly higher stability (30 min after injection) and noticeably higher tumor retention than their RM2 counterparts. Conclusion: On the basis of preclinical results, [161Tb]Tb-/[177Lu]Lu-AMTG might reveal a higher therapeutic efficacy than [161Tb]Tb-/[177Lu]Lu-RM2, particularly [161Tb]Tb-AMTG because of additional Auger-electron emissions at the cell membrane level.


Subject(s)
Electrons , Receptors, Bombesin , Mice , Animals , Mice, SCID , Tissue Distribution , Cell Membrane
3.
Front Chem ; 11: 1288588, 2023.
Article in English | MEDLINE | ID: mdl-37927558

ABSTRACT

Introduction: Targeted Radionuclide Therapy is used for the treatment of tumors in nuclear medicine, while sparing healthy tissues. Its application to cancer treatment is expanding. In particular, Auger-electron emitters potentially exhibit high efficacy in treating either small metastases or single tumor cells due to their short range in tissue. The aim of this paper is to study the feasibility of a large-scale production of thulium-167, an Auger-electron emitter radionuclide, in view of eventual systematic preclinical studies. Methods: Proton-irradiated enriched erbium-167 and erbium-168 oxides were used to measure the production cross sections of thulium-165, thulium-166, thulium-167, and thulium-168 utilizing an 18-MeV medical cyclotron equipped with a Beam Transport Line (BTL) at the Bern medical cyclotron laboratory. The comparison between the experimental and the TENDL 2021 theoretical cross-section results were in good agreement. Additional experiments were performed to assess the production yields of thulium radioisotopes in the BTL. Thulium-167 production yield was also measured irradiating five different target materials (167 Er 2 O 3, 168 Er 2 O 3, nat Tm 2 O 3, nat Yb 2 O 3, 171 Yb 2 O 3) with proton beams up to 63 MeV at the Injector II cyclotron of Paul Scherrer Institute. Results and Discussion: Our experiments showed that an 8-h irradiation of enriched ytterbium-171 oxide produced about 420 MBq of thulium-167 with a radionuclidic purity of 99.95% after 5 days of cooling time with a proton beam of about 53 MeV. Larger activities of thulium-167 can be achieved using enriched erbium-168 oxide with a 23-MeV proton beam, obtaining about 1 GBq after 8-h irradiation with a radionuclidic purity of <99.5% 5 days post end of bombardment.

4.
Pharmaceutics ; 15(11)2023 Nov 15.
Article in English | MEDLINE | ID: mdl-38004604

ABSTRACT

The first-in-class ruthenium-based chemotherapeutic agent BOLD-100 (formerly IT-139, NKP-1339, KP1339) is currently the subject of clinical evaluation for the treatment of gastric, pancreatic, colorectal and bile duct cancer. A radiolabeled version of the compound could present a helpful diagnostic tool. Thus, this study investigated the pharmacokinetics of BOLD-100 in more detail to facilitate the stratification of patients for the therapy. The synthesis of [103Ru]BOLD-100, radiolabeled with carrier added (c.a.) ruthenium-103, was established and the product was characterized by HPLC and UV/Vis spectroscopy. In order to compare the radiolabeled and non-radioactive versions of BOLD-100, both complexes were fully evaluated in vitro and in vivo. The cytotoxicity of the compounds was determined in two colon carcinoma cell lines (HCT116 and CT26) and biodistribution studies were performed in Balb/c mice bearing CT26 allografts over a time period of 72 h post injection (p.i.). We report herein preclinical cytotoxicity and pharmacokinetic data for BOLD-100, which were found to be identical to those of its radiolabeled analog [103Ru]BOLD-100.

5.
Appl Radiat Isot ; 200: 110954, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37527621

ABSTRACT

165Er is a pure Auger-electron emitter with promising characteristics for therapeutic applications in nuclear medicine. The short penetration path and high Linear Energy Transfer (LET) of the emitted Auger electrons make 165Er particularly suitable for treating small tumor metastases. Several production methods based on the irradiation with charged particles of Er and Ho targets can be found in the literature. In this paper, we report on the study of 165Er indirect production performed via the 166Er(p,2n)165Tm →165Er reaction at the 18 MeV Bern medical cyclotron. Despite the use of highly enriched 166Er2O3 targets, several Tm radioisotopes are produced during the irradiation, making the knowledge of the cross sections involved crucial. For this reason, a precise investigation of the cross sections of the relevant nuclear reactions in the energy range of interest was performed by irradiating Er2O3 targets with different isotopic enrichment levels and using a method based on the inversion of a linear system of equations. For the reactions 164Er(p, γ)165Tm, 166Er(p,n)166Tm, 166Er(p, γ)167Tm, 167Er(p,3n)165Tm, 167Er(p, γ)168Tm, 168Er(p,2n)167Tm and 170Er(p,3n)168Tm, the nuclear cross section was measured for the first time. From the results obtained, the production yield and purity of the parent radioisotope 165Tm were calculated to assess the optimal irradiation conditions. Several production tests with solid targets were performed to confirm these findings.

6.
J Nucl Med ; 64(10): 1625-1631, 2023 10.
Article in English | MEDLINE | ID: mdl-37442604

ABSTRACT

The favorable decay characteristics of 161Tb attracted the interest of clinicians in using this novel radionuclide for radioligand therapy (RLT). 161Tb decays with a similar half-life to 177Lu, but beyond the emission of ß--particles and γ-rays, 161Tb also emits conversion and Auger electrons, which may be particularly effective to eliminate micrometastases. The aim of this study was to compare the dosimetry and therapeutic efficacy of 161Tb and 177Lu in tumor-bearing mice using SibuDAB and PSMA-I&T, which differ in their blood residence time and tumor uptake. Methods: [161Tb]Tb-SibuDAB and [161Tb]Tb-PSMA-I&T were evaluated in vitro and investigated in biodistribution, imaging, and therapy studies using PC-3 PIP tumor-bearing mice. The 177Lu-labeled counterparts served for dose calculations and comparison of therapeutic efficacy. The tolerability of RLT in mice was monitored on the basis of body mass, blood plasma parameters, blood cell counts, and the histology of relevant organs and tissues. Results: The prostate-specific membrane antigen (PSMA)-targeting radioligands, irrespective of whether labeled with 161Tb or 177Lu, showed similar in vitro data and comparable tissue distribution profiles. As a result of the albumin-binding properties, [161Tb]Tb/[177Lu]Lu-SibuDAB had an enhanced blood residence time and higher tumor uptake (62%-69% injected activity per gram at 24 h after injection) than [161Tb]Tb/[177Lu]Lu-PSMA-I&T (30%-35% injected activity per gram at 24 h after injection). [161Tb]Tb-SibuDAB inhibited tumor growth more effectively than [161Tb]Tb-PSMA-I&T, as can be ascribed to its 4-fold increased absorbed tumor dose. At any of the applied activities, the 161Tb-based radioligands were therapeutically more effective than their 177Lu-labeled counterparts, as agreed with the approximately 40% increased tumor dose of 161Tb compared with that of 177Lu. Under the given experimental conditions, no obvious adverse events were observed. Conclusion: The data of this study indicate the promising potential of 161Tb in combination with SibuDAB for RLT of prostate cancer. Future clinical studies using 161Tb-based RLT will shed light on a potential clinical benefit of 161Tb over 177Lu.


Subject(s)
Prostatic Neoplasms , Radioisotopes , Male , Humans , Animals , Mice , Tissue Distribution , Cell Line, Tumor , Radioisotopes/therapeutic use , Radioisotopes/chemistry , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/drug therapy , Albumins/chemistry , Lutetium/therapeutic use , Lutetium/chemistry , Heterocyclic Compounds, 1-Ring/therapeutic use , Radiopharmaceuticals/chemistry , Dipeptides/therapeutic use , Prostate-Specific Antigen/metabolism
9.
J Nucl Med ; 64(7): 1138-1144, 2023 07.
Article in English | MEDLINE | ID: mdl-37201956

ABSTRACT

161Tb is an interesting radionuclide for application in the treatment of neuroendocrine neoplasms' small metastases and single cancer cells because of its conversion and Auger-electron emission. Tb has coordination chemistry similar to that of Lu; therefore, like 177Lu, it can stably radiolabel DOTATOC, one of the leading peptides used for the treatment of neuroendocrine neoplasms. However, 161Tb is a recently developed radionuclide that has not yet been specified for clinical use. Therefore, the aim of the current work was to characterize and specify 161Tb and to develop a protocol for the synthesis and quality control of 161Tb-DOTATOC with a fully automated process conforming to good-manufacturing-practice guidelines, in view of its clinical use. Methods: 161Tb, produced by neutron irradiation of 160Gd in high-flux reactors followed by radiochemical separation from its target material, was characterized regarding its radionuclidic purity, chemical purity, endotoxin level, and radiochemical purity (RCP) in analogy to what is described in the European Pharmacopoeia for no-carrier-added 177Lu. In addition, 161Tb was introduced into a fully automated cassette-module synthesis to produce 161Tb-DOTATOC, as used for 177Lu-DOTATOC. The quality and stability of the produced radiopharmaceutical in terms of identity, RCP, and ethanol and endotoxin content were assessed by means of high-performance liquid chromatography, gas chromatography, and an endotoxin test, respectively. Results: 161Tb produced under the described conditions showed, as the no-carrier-added 177Lu, a pH of 1-2, radionuclidic purity and RCP of more than 99.9%, and an endotoxin level below the permitted range (175 IU/mL), indicating its appropriate quality for clinical use. In addition, an efficient and robust procedure for the automated production and quality control of 161Tb-DOTATOC with clinically applicable specifications and activity levels, that is, 1.0-7.4 GBq in 20 mL, was developed. The radiopharmaceutical's quality control was also developed using chromatographic methods, which confirmed the product's stability (RCP ≥ 95%) over 24 h. Conclusion: The current study demonstrated that 161Tb has appropriate features for clinical use. The developed synthesis protocol guarantees high yields and safe preparation of injectable 161Tb-DOTATOC. The investigated approach could be translated to other DOTA-derivatized peptides; thus, 161Tb could be successfully applied in clinical practice for radionuclide therapy.


Subject(s)
Neoplasms , Radiopharmaceuticals , Humans , Radiopharmaceuticals/chemistry , Isotope Labeling/methods , Radioisotopes/chemistry , Octreotide , Neoplasms/drug therapy
10.
EJNMMI Res ; 13(1): 32, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37074529

ABSTRACT

PURPOSE: The angiotensin converting enzyme-2 (ACE2)-entry receptor of SARS-CoV-2-and its homologue, the angiotensin-converting enzyme (ACE), play a pivotal role in maintaining cardiovascular homeostasis. Potential changes in ACE2 expression levels and dynamics after SARS-CoV-2 infection have been barely investigated. The aim of this study was to develop an ACE2-targeting imaging agent as a noninvasive imaging tool to determine ACE2 regulation. METHODS: DOTA-DX600, NODAGA-DX600 and HBED-CC-DX600 were obtained through custom synthesis and labeled with gallium-67 (T1/2 = 3.26 d) as a surrogate radioisotope for gallium-68 (T1/2 = 68 min). ACE2- and ACE-transfected HEK cells were used for the in vitro evaluation of these radiopeptides. The in vivo tissue distribution profiles of the radiopeptides were assessed in HEK-ACE2 and HEK-ACE xenografted mice and imaging studies were performed using SPECT/CT. RESULTS: The highest molar activity was obtained for [67Ga]Ga-HBED-CC-DX600 (60 MBq/nmol), whereas the labeling efficiency of the other peptides was considerably lower (20 MBq/nmol). The radiopeptides were stable over 24 h in saline (> 99% intact peptide). All radiopeptides showed uptake in HEK-ACE2 cells (36-43%) with moderate ACE2-binding affinity (KD value: 83-113 nM), but no uptake in HEK-ACE cells (< 0.1%) was observed. Accumulation of the radiopeptides was observed in HEK-ACE2 xenografts (11-16% IA/g) at 3 h after injection, but only background signals were seen in HEK-ACE xenografts (< 0.5% IA/g). Renal retention was still high 3 h after injection of [67Ga]Ga-DOTA-DX600 and [67Ga]Ga-NODAGA-DX600 (~ 24% IA/g), but much lower for [67Ga]Ga-HBED-CC-DX600 (7.2 ± 2.2% IA/g). SPECT/CT imaging studies confirmed the most favorable target-to-nontarget ratio for [67Ga]Ga-HBED-CC-DX600. CONCLUSIONS: This study demonstrated ACE2 selectivity for all radiopeptides. [67Ga]Ga-HBED-CC-DX600 was revealed as the most promising candidate due to its favorable tissue distribution profile. Importantly, the HBED-CC chelator enabled 67Ga-labeling at high molar activity, which would be essential to obtain images with high signal-to-background contrast to detect (patho)physiological ACE2 expression levels in patients.

11.
Molecules ; 28(3)2023 Jan 31.
Article in English | MEDLINE | ID: mdl-36771012

ABSTRACT

44Sc is a promising radionuclide for positron emission tomography (PET) in nuclear medicine. As a part of the implementation of a production site for 44Sc, precise knowledge of the activity of the product is necessary. At the Paul Scherrer Institute (PSI) and the University of Bern (UniBE), 44Sc is produced by enriched 44CaO-target irradiation with a cyclotron. The two sites use different techniques for activity measurement, namely a dose calibrator at the PSI and a gamma-ray spectrometry system at UniBE and PSI. In this work, the 44Sc was produced at the PSI, and samples of the product were prepared in dedicated containers for onsite measurements at PSI, UniBE, and the Institute of Radiation Physics (IRA) in Lausanne for precise activity measurement using primary techniques and for the calibration of the reference ionization chambers. An accuracy of 1% was obtained for the activity measurement, allowing for a precise calibration of the dose calibrator and gamma-ray spectrometry of the two production sites. Each production site now has the capability of measuring 44Sc activity with an accuracy of 2%.

12.
Appl Radiat Isot ; 190: 110507, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36228535

ABSTRACT

The half-lives of 44Sc and 44mSc were measured by following their decay rate using several measurement systems: two ionization chambers and three γ-spectrometry detectors with digital and/or analogue electronics. For 44Sc, the result was the combination of seven half-life values giving a result of 4.042(7) h, which agrees with the last reported value of 4.042(3) h and confirms the near to 2% deviation from the recommended half-life of 3.97(4) h. Scandium-44 is present as an impurity in the production of 44Sc by cyclotron proton irradiation. Its half-life was determined by measurements performed a few days after End of Bomardment (EoB), so that the 44Sc decayed down to a negligible level. Seven measurements were combined to obtain an average of 58.7(3) h, which is in agreement with the recommended value of 58.6(1) h.


Subject(s)
Cyclotrons , Scandium , Half-Life , Scandium/chemistry
13.
EJNMMI Phys ; 9(1): 65, 2022 Sep 24.
Article in English | MEDLINE | ID: mdl-36153386

ABSTRACT

BACKGROUND: Based on theoretical and preclinical results, terbium-161 may be a valid alternative to lutetium-177 and yttrium-90 in radionuclide therapies. The large low-energy electron emission from terbium-161 is a favorable feature in the treatment of disseminated disease, but its impact on the radiosensitive bone marrow needs to be evaluated. Using voxel-based skeletal dosimetry models in which active bone marrow is defined as regions containing stem cells and progenitor cells of the hematopoietic lineage, we generated S-values (absorbed dose per decay) for terbium-161 and evaluated its distribution-dependence in bone marrow cavities. METHODS: S-values in the active bone marrow were calculated for terbium-161, lutetium-177, and yttrium-90 irradiation using two (male/female) image-based bone marrow dosimetry models. The radionuclides were distributed to one of the three structures that define the spongiosa bone region in the skeletal models: (i) active bone marrow, (ii) inactive bone marrow, or (iii) surface or whole volume of the trabecular bone. Decay data from ICRP 107 were combined with specific absorbed fractions to calculate S-values for 13 skeletal sites. To increase the utility, the skeletal site-specific S-values were averaged to produce whole-body average S-values and spongiosa average S-values. RESULTS: For yttrium-90, the high-energy ß particles irradiate the active marrow regardless of the source compartment, consistently generating the highest S-values (65-90% higher). Between terbium-161 and lutetium-177, the largest differences in S-values were with an active marrow source (50%), such as self-irradiation, due to the contribution of the short-ranged conversion and Auger electrons from terbium-161. Their influence decreased as the source moved to inactive marrow or the surface or volume of the trabecular bone, reducing the S-values and the differences between terbium-161 and lutetium-177 (15-35%). CONCLUSION: The S-values of terbium-161 for active bone marrow and, consequently, the bone marrow toxicity profile were more dependent on the radionuclide distribution within the bone marrow cavity than the S-values of lutetium-177 and yttrium-90. This effect was attributed to the considerable low-energy electron emission of terbium-161. Therefore, it will be critical to investigate the bone marrow distribution of a particular radiopharmaceutical for accurate estimation of the active bone marrow dose.

14.
Molecules ; 27(13)2022 Jun 28.
Article in English | MEDLINE | ID: mdl-35807404

ABSTRACT

Copper radioisotopes are generally employed for cancer imaging and therapy when firmly coordinated via a chelating agent coupled to a tumor-seeking vector. However, the biologically triggered Cu2+-Cu+ redox switching may constrain the in vivo integrity of the resulting complex, leading to demetallation processes. This unsought pathway is expected to be hindered by chelators bearing N, O, and S donors which appropriately complements the borderline-hard and soft nature of Cu2+ and Cu+. In this work, the labelling performances of a series of S-rich polyazamacrocyclic chelators with [64Cu]Cu2+ and the stability of the [64Cu]Cu-complexes thereof were evaluated. Among the chelators considered, the best results were obtained with 1,7-bis [2-(methylsulfanyl)ethyl]-4,10,diacetic acid-1,4,7,10-tetraazacyclododecane (DO2A2S). DO2A2S was labelled at high molar activities in mild reaction conditions, and its [64Cu]Cu2+ complex showed excellent integrity in human serum over 24 h. Biodistribution studies in BALB/c nude mice performed with [64Cu][Cu(DO2A2S)] revealed a behavior similar to other [64Cu]Cu-labelled cyclen derivatives characterized by high liver and kidney uptake, which could either be ascribed to transchelation phenomena or metabolic processing of the intact complex.


Subject(s)
Copper Radioisotopes , Precision Medicine , Animals , Chelating Agents , Mice , Mice, Nude , Positron-Emission Tomography/methods , Radiopharmaceuticals/metabolism , Tissue Distribution
15.
Appl Radiat Isot ; 184: 110175, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35344829

ABSTRACT

155Tb [t1/2 = 5.32 d, Eγ = 87 keV (32%); 105 keV (25%) (IAEA, 2021)] is a novel promising radionuclide for theranostic applications in nuclear medicine. Its physical properties make it suitable for single photon emission computed tomography (SPECT) imaging, while its chemistry allows it to be used as a diagnostic partner for therapeutic radiolanthanides or pseudo-radiolanthanides, such as 177Lu and 90Y. Moreover, 155Tb could be used as a precise diagnostic match for the ß--emitter 161Tb, opening doors for the true theranostics concept. The availability of 155Tb in quantity and quality suitable for medical applications is an open issue and its production with medical cyclotrons via the 155Gd(p,n)155Tb and 156Gd(p,2n)155Tb nuclear reactions represents a possible but challenging solution. For this purpose, an accurate knowledge of the production cross sections is mandatory. In this paper, we report on the measurement of the production cross sections of 155Tb and other terbium radionuclides formed by proton irradiation of natGd2O3, 155Gd2O3 and 156Gd2O3 enriched targets, performed at the Bern University Hospital cyclotron laboratory. On the basis of the obtained results, the production yield and purity were calculated to assess the optimal irradiation conditions. The results of several production tests are also presented.


Subject(s)
Cyclotrons , Terbium , Humans , Positron-Emission Tomography/methods , Radioisotopes/chemistry , Terbium/chemistry , Tomography, Emission-Computed, Single-Photon/methods
16.
EJNMMI Phys ; 9(1): 19, 2022 Mar 14.
Article in English | MEDLINE | ID: mdl-35286498

ABSTRACT

BACKGROUND: 161Tb draws an increasing interest in nuclear medicine for therapeutic applications. More than 99% of the emitted gamma and X-rays of 161Tb have an energy below 100 keV. Consequently, precise activity measurement of 161Tb becomes inaccurate with radionuclide dose calibrators when using inappropriate containers or calibration factors to account for the attenuation of this low energy radiation. To evaluate the ionization chamber response, the sample activity must be well known. This can be performed using standards traceable to the Système International de Référence, which is briefly described as well as the method to standardize the radionuclides. METHODS: In this study, the response of an ionization chamber using different container types and volumes was assessed using 161Tb. The containers were filled with a standardized activity solution of 161Tb and measured with a dedicated ionization chamber, providing an accurate response. The results were compared with standardized solutions of high-energy gamma-emitting radionuclides such as 137Cs, 60Co, 133Ba and 57Co. RESULTS: For the glass vial type with an irregular glass thickness, the 161Tb measurements gave a deviation of 4.5% between two vials of the same type. The other glass vial types have a much more regular thickness and no discrepancy was observed in the response of the ionization chamber for these type of vials. Measurements with a plastic Eppendorf tube showed stable response, with greater sensitivity than the glass vials. CONCLUSION: Ionization chamber measurements for low-energy gamma emitters (< 100 keV), show deviation depending on the container type used. Therefore, a careful selection of the container type must be done for activity assessment of 161Tb using radionuclide dose calibrators. In conclusion, it was highlighted that appropriate calibration factors must be used for each container geometry when measuring 161Tb and, more generally, for low-energy gamma emitters.

17.
Eur J Nucl Med Mol Imaging ; 49(4): 1113-1126, 2022 03.
Article in English | MEDLINE | ID: mdl-34625828

ABSTRACT

PURPOSE: The ߯-emitting terbium-161 also emits conversion and Auger electrons, which are believed to be effective in killing single cancer cells. Terbium-161 was applied with somatostatin receptor (SSTR) agonists that localize in the cytoplasm (DOTATOC) and cellular nucleus (DOTATOC-NLS) or with a SSTR antagonist that localizes at the cell membrane (DOTA-LM3). The aim was to identify the most favorable peptide/terbium-161 combination for the treatment of neuroendocrine neoplasms (NENs). METHODS: The capability of the 161Tb- and 177Lu-labeled somatostatin (SST) analogues to reduce viability and survival of SSTR-positive AR42J tumor cells was investigated in vitro. The radiopeptides' tissue distribution profiles were assessed in tumor-bearing mice. The efficacy of terbium-161 compared to lutetium-177 was investigated in therapy studies in mice using DOTATOC or DOTA-LM3, respectively. RESULTS: In vitro, [161Tb]Tb-DOTA-LM3 was 102-fold more potent than [177Lu]Lu-DOTA-LM3; however, 161Tb-labeled DOTATOC and DOTATOC-NLS were only 4- to fivefold more effective inhibiting tumor cell viability than their 177Lu-labeled counterparts. This result was confirmed in vivo and demonstrated that [161Tb]Tb-DOTA-LM3 was significantly more effective in delaying tumor growth than [177Lu]Lu-DOTA-LM3, thereby, prolonging survival of the mice. A therapeutic advantage of terbium-161 over lutetium-177 was also manifest when applied with DOTATOC. Since the nuclear localizing sequence (NLS) compromised the in vivo tissue distribution of DOTATOC-NLS, it was not used for therapy. CONCLUSION: The use of membrane-localizing DOTA-LM3 was beneficial and profited from the short-ranged electrons emitted by terbium-161. Based on these preclinical data, [161Tb]Tb-DOTA-LM3 may outperform the clinically employed [177Lu]Lu-DOTATOC for the treatment of patients with NENs.


Subject(s)
Neuroendocrine Tumors , Receptors, Somatostatin , Animals , Humans , Mice , Neuroendocrine Tumors/pathology , Octreotide , Radioisotopes , Receptors, Somatostatin/metabolism , Terbium/therapeutic use , Tissue Distribution
18.
Cancers (Basel) ; 13(24)2021 Dec 08.
Article in English | MEDLINE | ID: mdl-34944803

ABSTRACT

Developments throughout the history of nuclear medicine have involved improvements in both instrumentation and radionuclides, which have been intertwined. Instrumentation developments always occurred during the search to improving devices' sensitivity and included advances in detector technology (with the introduction of cadmium zinc telluride and digital Positron Emission Tomography-PET-devices with silicon photomultipliers), design (total body PET) and configuration (ring-shaped, Single-Photon Emission Computed Tomography (SPECT), Compton camera). In the field of radionuclide development, we observed the continual changing of clinically used radionuclides, which is sometimes influenced by instrumentation technology but also driven by availability, patient safety and clinical questions. Some areas, such as tumour imaging, have faced challenges when changing radionuclides based on availability, when this produced undesirable clinical findings with the introduction of unclear focal uptakes and unspecific uptakes. On the other end of spectrum, further developments of PET technology have seen a resurgence in its use in nuclear cardiology, with rubidium-82 from strontium-82/rubidium-82 generators being the radionuclide of choice, moving away from SPECT nuclides thallium-201 and technetium-99m. These continuing improvements in both instrumentation and radionuclide development have helped the growth of nuclear medicine and its importance in the ever-evolving range of patient care options.

19.
Diagnostics (Basel) ; 11(10)2021 Oct 03.
Article in English | MEDLINE | ID: mdl-34679525

ABSTRACT

Scandium-44 has been proposed as a valuable radionuclide for Positron Emission Tomography (PET). Recently, scandium-43 was introduced as a more favorable option, as it does not emit high-energy γ-radiation; however, its currently employed production method results in a mixture of scandium-43 and scandium-44. The interest in new radionuclides for diagnostic nuclear medicine critically depends on the option for image-based quantification. We aimed to evaluate and compare the quantitative capabilities of scandium-43/scandium-44 in a commercial PET/CT device with respect to more conventional clinical radionuclides (fluorine-18 and gallium-68). With this purpose, we characterized and compared quantitative PET data from a mixture of scandium-43/scandium-44 (~68% scandium-43), scandium-44, fluorine-18 and gallium-68, respectively. A NEMA image-quality phantom was filled with the different radionuclides using clinical-relevant lesion-to-background activity concentration ratios; images were acquired in a Siemens Biograph Vision PET/CT. Quantitative accuracy with scandium-43/scandium-44 in the phantom's background was within 9%, which is in agreement with fluorine-18-based PET standards. Coefficient of variance (COV) was 6.32% and signal recovery in the lesions provided RCmax (recovery coefficient) values of 0.66, 0.90, 1.03, 1.04, 1.12 and 1.11 for lesions of 10-, 13-, 17-, 22-, 28- and 37-mm diameter, respectively. These results are in agreement with EARL reference values for fluorine-18 PET. The results in this work showed that accurate quantitative scandium-43/44 PET/CT is achievable in commercial devices. This may promote the future introduction of scandium-43/44-labelled radiopharmaceuticals into clinical use.

20.
Front Med (Lausanne) ; 8: 712374, 2021.
Article in English | MEDLINE | ID: mdl-34712674

ABSTRACT

Thulium-167 is a promising radionuclide for nuclear medicine applications with potential use for both diagnosis and therapy ("theragnostics") in disseminated tumor cells and small metastases, due to suitable gamma-line as well as conversion/Auger electron energies. However, adequate delivery methods are yet to be developed and accompanying radiobiological effects to be investigated, demanding the availability of 167Tm in appropriate activities and quality. We report herein on the production of radionuclidically pure 167Tm from proton-irradiated natural erbium oxide targets at a cyclotron and subsequent ion beam mass separation at the CERN-MEDICIS facility, with a particular focus on the process efficiency. Development of the mass separation process with studies on stable 169Tm yielded 65 and 60% for pure and erbium-excess samples. An enhancement factor of thulium ion beam over that of erbium of up to several 104 was shown by utilizing laser resonance ionization and exploiting differences in their vapor pressures. Three 167Tm samples produced at the IP2 irradiation station, receiving 22.8 MeV protons from Injector II at Paul Scherrer Institute (PSI), were mass separated with collected radionuclide efficiencies between 11 and 20%. Ion beam sputtering from the collection foils was identified as a limiting factor. In-situ gamma-measurements showed that up to 45% separation efficiency could be fully collected if these limits are overcome. Comparative analyses show possible neighboring mass suppression factors of more than 1,000, and overall 167Tm/Er purity increase in the same range. Both the actual achieved collection and separation efficiencies present the highest values for the mass separation of external radionuclide sources at MEDICIS to date.

SELECTION OF CITATIONS
SEARCH DETAIL
...