Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
World J Urol ; 42(1): 467, 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39093491

ABSTRACT

PURPOSE: The solid-state Thulium laser (Tm: YAG) is a novel alternative to the widely used Holmium laser for endoscopic enucleation of the prostate (EEP) due to its relatively high peak power. The aim of this study was to examine the efficacy and safety of a new pulsed Tm: YAG laser in its first application in humans. METHODS: Data were retrospectively collected for the first 103 patients who underwent EEP with a new pulsed solid-state Tm: YAG laser (Thulio®, Dornier MedTech Systems GmbH, Weßling, Germany). Peri- and postoperative data were assessed. Procedure-specific complications were graded using Clavien-Dindo Classifications (CDC). Patients were interviewed 15 months after the surgery to evaluate functional and long-term outcomes. Statistical analysis was performed with Statistical Package for the Social Sciences (SPSS®). RESULTS: The mean preoperative prostate volume was 105.6 ± 55.0 ml. Median enucleation speed was 4.1 g per minute (range 1.1-9.7). Short-term postoperative complications occurred in 21 patients (20.4%), but no high-grade complications (CDC ≥ IV) were observed. Five patients suffered gross haematuria and required reintervention (CDC IIIb; 4.9%). After 15 months, 76 patients (73.8%) participated in the follow-up interview, where seven patients (9.2%) reported complications, including two reinterventions for urethral strictures (CDC IIIb; 2.6%). Most patients reported an improvement in continence (54.0%) and urine stream (93.4%), but no difference in erectile function (81.6%). No persistent dysuria was reported. Patient satisfaction with the surgery results was very high (96.1%). CONCLUSION: Endoscopic enucleation of the prostate with the new pulsed solid-state Tm: YAG laser is a safe and effective option for surgical BPH treatment. TRIAL REGISTRATION: German Clinical Trials Register number: DRKS00031676. Registration date: 10 May 2023, retrospectively registered.


Subject(s)
Lasers, Solid-State , Prostatic Hyperplasia , Thulium , Humans , Male , Lasers, Solid-State/therapeutic use , Aged , Retrospective Studies , Prostatic Hyperplasia/surgery , Middle Aged , Thulium/therapeutic use , Prostatectomy/methods , Aged, 80 and over , Treatment Outcome , Endoscopy/methods , Postoperative Complications/epidemiology , Laser Therapy/methods
2.
BMC Med Inform Decis Mak ; 24(1): 136, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38802886

ABSTRACT

BACKGROUND: The selection of data elements is a decisive task within the development of a health registry. Having the right metadata is crucial for answering the particular research questions. Furthermore, the set of data elements determines the registries' readiness of interoperability and data reusability to a major extent. Six health registries shared and published their metadata within a German funding initiative. As one step in the direction of a common set of data elements, a selection of those metadata was evaluated with regard to their appropriateness for a broader usage. METHODS: Each registry was asked to contribute a 10%-selection of their data elements to an evaluation sample. The survey was set up with the online survey tool "LimeSurvey Cloud". The registries and an accompanying project participated in the survey with one vote for each project. The data elements were offered in content groups along with the question of whether the data element is appropriate for health registries on a broader scale. The question could be answered using a Likert scale with five options. Furthermore, "no answer" was allowed. The level of agreement was assessed using weighted Cohen's kappa and Kendall's coefficient of concordance. RESULTS: The evaluation sample consisted of 269 data elements. With a grade of "perhaps recommendable" or higher in the mean, 169 data elements were selected. These data elements belong preferably to groups' demography, education/occupation, medication, and nutrition. Half of the registries lost significance compared with their percentage of data elements in the evaluation sample, one remained stable. The level of concordance was adequate. CONCLUSIONS: The survey revealed a set of 169 data elements recommended for health registries. When developing a registry, this set could be valuable help in selecting the metadata appropriate to answer the registry's research questions. However, due to the high specificity of research questions, data elements beyond this set will be needed to cover the whole range of interests of a register. A broader discussion and subsequent surveys are needed to establish a common set of data elements on an international scale.


Subject(s)
Registries , Registries/standards , Germany , Humans , Surveys and Questionnaires , Metadata
3.
World J Urol ; 41(12): 3853-3865, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38010538

ABSTRACT

OBJECTIVE: Technological advancements in the field of urology have led to a paradigm shift in the management of urolithiasis towards minimally invasive endourological interventions, namely ureteroscopy and percutaneous nephrolithotomy. However, concerns regarding the potential for thermal injury during laser lithotripsy have arisen, as studies have indicated that the threshold for cellular thermal injury (43 °C) can be exceeded, even with conventional low-power laser settings. This review aims to identify the factors that contribute to temperature increments during laser treatment using current laser systems and evaluate their impact on patient outcomes. MATERIALS AND METHODS: To select studies for inclusion, a search was performed on online databases including PubMed and Google Scholar. Keywords such as 'temperature' or 'heat' were combined with 'lithotripsy', 'nephrolithotomy', 'ureteroscopy', or 'retrograde intrarenal surgery', both individually and in various combinations. RESULTS: Various strategies have been proposed to mitigate temperature rise, such as reducing laser energy or frequency, shortening the duration of laser activation, increasing the irrigation fluid flow rate, and using room temperature or chilled water for irrigation. It is important to note that higher irrigation fluid flow rates should be approached cautiously due to potential increases in intrarenal pressure and associated infectious complications. The utilization of a ureteral access sheath (UAS) may offer benefits by facilitating irrigation fluid outflow, thereby reducing intrapelvic pressure and intrarenal fluid temperature. CONCLUSION: Achieving a balance between laser power, duration of laser activation, and irrigation fluid rate and temperature appears to be crucial for urologists to minimize excessive temperature rise.


Subject(s)
Kidney Calculi , Lasers, Solid-State , Lithotripsy, Laser , Ureter , Humans , Hot Temperature , Temperature , Lasers, Solid-State/therapeutic use , Kidney Calculi/surgery , Ureteroscopy/adverse effects , Lithotripsy, Laser/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL