Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Heart J ; 18(6): 931-40, 1997 Jun.
Article in English | MEDLINE | ID: mdl-9183584

ABSTRACT

AIMS: The selection of ECG leads used for ST monitoring may influence detection and quantitation of ischaemia. METHODS: We compared on-line continuous 48-h 12-lead against 3-lead ST monitoring in 130 unstable angina patients (Mortara. ELI-100). Onset and offset of ST episodes were defined by the lead with the first > or = 100 microV ST change relative to baseline and the lead with the latest return to baseline ST level, respectively. ST episodes were calculated for 12 leads and 3 leads (V2, V5, III) separately. RESULTS: ST episodes were detected in 88 patients (77%) by 12-lead and in 71 patients (62%) by 3-lead ST monitoring (P < 0.02). The median number (25.75%) of episodes/patient was 1 (0.3) for 3-lead and 2 (1.6) for 12-lead (P < 0.0001). The total duration of ischaemia detected during 12-lead far exceeded 3-lead monitoring: 12.3 (1, 58.2) and 1.7 (0, 23.3) min respectively (P < 0.0001). The probability of recurrent ischaemia declined most during the first 24 h of monitoring. After a period without ST changes of 1, 12, 24 and 36 h, the probabilities of recurrent ischaemia were 63, 31, 14 and 9%, respectively. CONCLUSIONS: Continuous 12-lead ST monitoring increases detection rate and duration of ST episodes compared to 3-lead ST monitoring. The use of continuous 12-lead ECG monitoring devices on emergency wards and coronary care units is recommended.


Subject(s)
Angina, Unstable/complications , Diagnosis, Computer-Assisted , Electrocardiography/instrumentation , Myocardial Ischemia/diagnosis , Chi-Square Distribution , Electrocardiography/methods , Female , Humans , Male , Monitoring, Physiologic/methods , Myocardial Ischemia/etiology , Myocardial Ischemia/physiopathology , Sensitivity and Specificity
2.
Int J Card Imaging ; 12(1): 21-30, 1996 Mar.
Article in English | MEDLINE | ID: mdl-8847451

ABSTRACT

The ABC classification of the American College of Cardiology and the American Heart Association is a commonly used categorization to estimate the risk and success of intracoronary intervention, as well as the probability of restenosis. To evaluate the reliability of qualitative angiogram readings, we randomly selected 200 films from single lesion angioplasty procedures. A repeated visual assessment (> or = 2 months interval) by two independent observers resulted in kappa values of inter and intra-observer variability for the ABC lesion classification and for all separate items that compile it. Variability in assessment is expressed in percentage of total agreement, and in kappa value, which is a parameter of the agreement between two or more observations in excess of the chance agreement. Percentage of total agreement and kappa value was 67.8% and 0.33 respectively for the ABC classification, indicating a poor agreement. Probably this is due to the deficiency of strict definitions. Further investigation has to demonstrate whether improvement can be achieved using complete and detailed definitions without ambiguity, and consensus after panel assessment.


Subject(s)
Coronary Angiography/statistics & numerical data , Coronary Disease/diagnostic imaging , Coronary Disease/epidemiology , Humans , Observer Variation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...