Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters











Publication year range
1.
Vascular ; 31(3): 447-454, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35100906

ABSTRACT

OBJECTIVES: The aim of this study is to summarize a single-center experience of hybrid debranching endovascular repair of the aortic arch and proximal descending thoracic aorta (DTA) with regard to the mid-term outcomes with highlighting the difference between the landing zones 0-2. METHODS: A retrospective review of data from a prospectively collected registry (Gangnam Severance Endovascular Aortic Registry) was performed. From among 332 patients whose aortic pathology was managed with TEVAR, 112 patients who underwent hybrid arch repair during the study period between 2012 and 2016 were identified. The patients were grouped into three cohorts according to the proximal landing zones (0, 1, and 2) of Ishimaru. The early outcome (30-days) in terms of mortality, morbidity, supra-aortic vessels patency, and presence of endoleak were analyzed. The survival, freedom from re-intervention, and major complications during follow-up were demonstrated. RESULTS: During the study period. 112 patients (mean age 65±7, 79% males) were included. The patients were distributed in three cohorts: 8 (7%) patients with proximal landing zone 0, 20 (18%) with zone 1, and 80 (75%) with zone 2 hybrid aortic arch repair. Technical success was achieved in 7 (88%), 19 (90%), and 79 (94%) patients for zones 0, 1, and 2, respectively. The mean intensive care unit (ICU) stay was shorter in zone 2 (p = .005). The mean total hospital stay was shorter in zone 2 (p = .03). The overall in-hospital mortality rate was 5% (4/112). There was no spinal cord ischemia or early surgical conversion. Renal function deterioration was seen more but not significantly in zone 0 patients (p = .08). Respiratory failure was seen significantly in zone 0 patients (p = .01). Stroke occurred in 6/44 (14%) patients with degenerative aneurysm versus 1/60 (2%) patients with aortic dissection (p =.06). Early CTA showed 100% patency of the supra-aortic vessels. The early endoleak rate was significant in zone 0 patients (p = .008). The mean follow-up period was (32±19 months). The survival rates and freedom from re-intervention were not statistically significant among the three zones. However, the survival rate and freedom from intervention tend to be higher in zone 2 versus zone 0 (p = .07 and .09), respectively. CONCLUSION: Hybrid debranching endovascular aortic arch repair is feasible and relatively safe with acceptable mid-term outcomes. Zone 0 patients has worse early and late outcomes in comparison to other zones. Careful patient selection and improved endovascular technology may be the key to improve the outcomes.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , Middle Aged , Aged , Female , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Endoleak/etiology , Endoleak/surgery , Blood Vessel Prosthesis/adverse effects , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Blood Vessel Prosthesis Implantation/adverse effects , Risk Factors , Endovascular Procedures/adverse effects , Retrospective Studies , Treatment Outcome
2.
Int J Angiol ; 31(1): 56-60, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35221854

ABSTRACT

Aortic arch pathology in a high-risk patient in whom the resternotomy approach is unfeasible due to treated mediastinitis after ascending aortic replacement presents a unique challenge for hybrid arch repair (HAR) because of the need for supra-aortic debranching from unusual inflow sites other than the ascending aorta. This report describes a "reversed sequence" extra-anatomical supra-aortic debranching procedure as a salvage technique performed to enable HAR. An 83-year-old woman with a history of ascending aortic replacement for type A aortic dissection, mediastinitis complicated by sternal osteomyelitis, and a chest wall reconstructed with a rectus abdominis myocutaneous flap presented with chest pain because of a contained dissecting arch aneurysm rupture. The patient underwent supra-aortic debranching from the bilateral common femoral arteries and thoracic endovascular aortic repair to the ascending aorta under cerebral near-infrared spectroscopy (NIRS) monitoring. Completion imaging by angiography demonstrated successful exclusion of the ruptured aneurysm. The regional cerebral oxygen saturation level, monitored by NIRS, did not change markedly during surgery. The patient was neurologically intact with adequate cerebral blood flow assessed postoperatively by 123 I-IMP single photon emission computed tomography. Total debranching of the supra-aortic vessels from the common femoral artery for inflow is feasible and provides adequate cerebral perfusion. This procedure may offer an alternative treatment option in patients with complex conditions involving aortic arch pathology.

3.
Cardiovasc Drugs Ther ; 36(2): 285-294, 2022 04.
Article in English | MEDLINE | ID: mdl-33528720

ABSTRACT

PURPOSE: Hybrid aortic arch repair in patients with chronic residual aortic dissection (RAD) is a less invasive alternative to conventional surgical treatment. The aim of this study was to describe the short-term and long-term results of hybrid treatment for RAD after type A repair. METHODS: In this retrospective single-center cohort study, all patients treated for chronic RAD with hybrid aortic arch repair were included. Indications for treatment were rapid aortic growth, aortic diameter > 55 mm, or aortic rupture. RESULTS: Between 2009 and 2020, we performed 29 hybrid treatments for chronic RAD. Twenty-four patients were treated for complete supra-aortic debranching in zones 0 and 5 with left subclavian artery debranching alone in zone 2. There was 1 perioperative death (3.4%): The patient was treated for an aortic rupture. There was no spinal cord ischemia and 1 minor stroke (3.4%). After a median follow-up of 25.4 months (range 3-97 months), the long-term mortality was 10.3% (3/29) with no late aortic-related deaths. Twenty-seven patients (93.1%) developed FL thrombosis of the descending thoracic aorta; the rate of aneurysmal progression on thoraco-abdominal aorta was 41.4% (12/29), and the rate of aortic reintervention was 34.5% (10/29). CONCLUSION: In a high-volume aortic center, hybrid repair of RAD is associated with good anatomical results and a low risk of perioperative morbidity and mortality, including that of patients treated in zone 0. A redo replacement of the ascending aortic segment is sometimes necessary to provide a safer proximal landing zone and reduce the risk of type 1 endoleak after TEVAR.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Aortic Rupture , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Rupture/diagnostic imaging , Aortic Rupture/etiology , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Cohort Studies , Endovascular Procedures/adverse effects , Humans , Retrospective Studies , Risk Factors , Stents , Time Factors , Treatment Outcome
4.
J Vasc Surg Cases Innov Tech ; 7(3): 374-377, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34278061

ABSTRACT

We report a case of a hybrid aortic debranching procedure for repair of a paravisceral inflammatory aortic aneurysm. Vein grafts were chosen over prosthetics because of concern for infection as a possible etiology. The gonadal vein was successfully used as a vein graft between the right common iliac artery and the right renal artery before aortic endograft placement.

5.
Innovations (Phila) ; 15(4): 386-388, 2020.
Article in English | MEDLINE | ID: mdl-32757965

ABSTRACT

We report a successful treatment of type A acute aortic syndrome (AAS)-associated aortic arch aneurysm in a 71-year-old man with major comorbidities. The ascending aorta was wrapped with artificial graft, and supra-aortic debranching was constructed. Then, Zone 0 thoracic endovascular aneurysm repair (TEVAR) with plug occlusion of the left subclavian artery was successfully performed. The patient was discharged in good physical condition without any complications. To our knowledge, this is the first reported case in the literature of successful Zone 0 TEVAR after ascending aorta wrapping and supra-aortic debranching with type A AAS associated with aortic arch aneurysm.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Endovascular Procedures/methods , Acute Disease , Aged , Aortic Dissection/surgery , Aorta/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Humans , Male , Tomography, X-Ray Computed
6.
Ann Cardiothorac Surg ; 7(3): 357-365, 2018 May.
Article in English | MEDLINE | ID: mdl-30155414

ABSTRACT

BACKGROUND: Mega-aortic syndrome (MAS) is a rare disease carrying a poor prognosis if treated conservatively. Open repairs of these aneurysms are invasive, while totally endovascular repairs are associated with higher rates of late reintervention due to endoleaks, compromising long-term prognosis. We describe the 10-year results of a hybrid three-stage approach to MAS using the Lupiae technique. METHODS: Between 2006 and 2016, 27 patients with MAS extending from the ascending aorta to the iliac arteries (MAS type III) underwent: (I) a surgical aortic arch debranching, using the Vascutek Lupiae™ multibranched graft to create a proximal Dacron landing zone; (II) an abdominal aorta debranching to create a distal Dacron landing zone and (III) the implantation of multiple endovascular stents to exclude any residual aneurysm between the two landing zones. RESULTS: One patient died following the first stage, and another following the second stage of the repair (overall mortality 7.4%). The interval between the first and the second stage was 58.3±16.1 days. The interval between the second and the third stage was 47.7±13.1 days. Four-year survival was 88.6%±6.2% while 10-year survival was 51.7%±17.9%. One patient had a type III endoleak after the third stage that self-resolved within 6 months without intervention. No patient had type I or II endoleaks and none underwent redo procedures. Mean follow-up was 5.9±3.6 years and completeness was 100%. CONCLUSIONS: Three-stage hybrid repairs using the Lupiae technique can be safely performed in MAS type III patients. Short intervals between the stages should mitigate the risk of rupture during the waiting periods and may enhance patient compliance, but to achieve this, the burden and the complexity of the first stage must be carefully weighted. Our strategy improves the long-term survival of these patients compared to their natural history and is less invasive than an open repair. The adoption of Dacron landing zones appears to be associated with very low rates of reintervention due to endoleaks.

7.
EJVES Short Rep ; 38: 20-22, 2018.
Article in English | MEDLINE | ID: mdl-29780895

ABSTRACT

INTRODUCTION: Hybrid aortic arch repair for the treatment of aorto-bronchial fistulas has been suggested as a safe alternative to open repair. However, surgical morbidity and mortality are still significant and re-intervention is sometimes inevitable. REPORT: Successful rescue by a hybrid approach is reported in a 76 year old woman who was transferred from another centre with recurrent episodes of left hemiplegia shortly after debranching of the supra-aortic vessels and thoracic aortic stent grafting for an aorto-bronchial fistula associated with a true aneurysm at the level of origin of the left subclavian artery. Investigation revealed partial coverage of the ostium of the brachiocephalic artery and Type Ib and II endoleaks. In the first stage a chimney graft was put into the brachiocephalic trunk, and in the second stage the left subclavian artery was plugged and the thoracic stent graft was extended distally. Completion angiography showed restoration of the supra-aortic blood flow and no residual endoleaks. After 1 year follow up the patient was doing well with no recurrent neurological events and no signs of infection. DISCUSSION: Procedure related problems should be suspected first when early post-operative complications occur after a hybrid aortic arch repair. The chimney graft technique is a valuable option for unintentional covering of a critical supra-aortic branch. Nevertheless, the importance of precise positioning during initial thoracic stent graft placement should be emphasised.

9.
Vasc Endovascular Surg ; 50(3): 160-3, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26993592

ABSTRACT

The treatment of thoracoabdominal aneurysms and juxtarenal aortic aneurysms remains technically challenging, with outcomes primarily dictated by aortic cross-clamp and end-organ ischemia during branch reconstruction. This has remained a challenge for the surgeon regardless of an elective setting or an emergent operation. Here we describe the application of a novel hybrid graft technique for aortic branch reconstruction using rapid, endoluminal anastomoses during open aortic reconstruction.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Plastic Surgery Procedures/instrumentation , Aged , Aged, 80 and over , Anastomosis, Surgical , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Computed Tomography Angiography , Female , Humans , Male , Middle Aged , Prosthesis Design , Treatment Outcome
10.
Eur J Cardiothorac Surg ; 47(1): 126-33; discussion 133, 2015 Jan.
Article in English | MEDLINE | ID: mdl-24674908

ABSTRACT

OBJECTIVES: Several techniques have been described for the treatment of thoraco-abdominal aneurysms in patients with mega-aortic syndrome (MAS), but the incidence of stroke, spinal cord injury and endoleaks remains significant. We present the mid-term results of a new hybrid, multistep technique to treat patients with MAS. METHODS: From November 2005 to November 2012, 118 patients with MAS underwent surgical repair of thoracic and thoraco-abdominal aneurysms with the Lupiae technique. Fifty-five patients presented chronic aneurysms and 63 patients Type A acute dissections. Eighty-three patients underwent ascending aorta and arch replacement with a multibranched Dacron graft and epiaortic vessels rerouting (thoracic Lupiae procedure). Twenty patients had the thoracic Lupiae procedure plus partial visceral debranching (coeliac trunk and superior mesenteric artery [SMA]) through an upper mini-laparotomy. Fifteen patients had the thoracic Lupiae procedure plus a complete visceral debranching (coeliac trunk, SMA and renal arteries) using a second multibranched Dacron graft to replace the infrarenal aorta. All the patients with chronic aneurysms and 34 of 63 patients with Type A dissections underwent implant of endovascular stent grafts. RESULTS: In-hospital mortality was 8.4%. No patients had stroke or spinal cord injury. The incidence of temporary renal failure was 5.2%. No patients presented endoleaks immediately and at follow-up CT scans. No death or reoperation occurred during the follow-up. CONCLUSIONS: These results evidence that the Lupiae technique is a safe and effective option for the treatment of patients with MAS, achieving the complete exclusion of thoraco-abdominal aneurysms and of the residual false lumen in patients with acute aortic dissections.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/mortality , Blood Vessel Prosthesis Implantation/methods , Aged , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Female , Humans , Male , Middle Aged , Polyethylene Terephthalates , Retrospective Studies , Stents
12.
Rev Port Cardiol ; 32(6): 535-9, 2013 Jun.
Article in English, Portuguese | MEDLINE | ID: mdl-23561832

ABSTRACT

The authors describe the case of a 59-year-old man, a former smoker, with hypertension, chronic renal failure undergoing hemodialysis, and a history of stent grafting for repair of an abdominal aortic aneurysm and miliary tuberculosis, who was diagnosed with constrictive pericarditis and a thoracic aortic aneurysm. In a patient with such a complex medical history, there were several etiologies to consider. The treatment consisted of pericardiectomy and a hybrid technique of supra-aortic debranching and subsequent endovascular stent-graft repair.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Pericarditis, Constrictive/surgery , Aortic Aneurysm, Thoracic/complications , Combined Modality Therapy , Humans , Male , Middle Aged , Pericarditis, Constrictive/complications
SELECTION OF CITATIONS
SEARCH DETAIL