Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.609
Filter
1.
Jpn Dent Sci Rev ; 60: 190-197, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38974884

ABSTRACT

Most reports on duplicate dentures are introduction to fabrication methods or clinical case reports. Only a few studies have verified their clinical effectiveness; hence, evidence to construct useful clinical guidelines for duplicate denture use is lacking. This review aimed to comprehensively investigate reports on duplicate dentures to accumulate evidences that will contribute to the formulation of clinical practice guidelines. Duplicate dentures are effectively used for impression making and bite registration when fabricating new dentures, thereby reducing the number of clinic visits and treatment time. Duplicate denture can also be used as temporary or new dentures. Older people in whom various adaptive abilities have declined, may find it difficult to adjust to new dentures and experience stress, even if the shape is appropriate. Duplicate dentures, which reproduces the shape of old dentures that they are used to, have the advantage of being more familiar to older people and less stressful. When manufacturing duplicate dentures, digital methods such as milling and three-dimensional printing are superior to conventional methods regarding working time and cost. A notable advantage of the digital method is that the denture shape can be saved as digital data, and the denture can be easily duplicated if lost.

2.
Eur J Dent Educ ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39014875

ABSTRACT

INTRODUCTION: The use of digital dentistry is rapidly increasing in prosthodontics. However, most dental students are not familiar with applying digital technologies in dental clinics. Thus, the aim of the current study was to assess the perception of dental students at different educational years towards digital impressions in comparison to conventional impressions. MATERIALS AND METHODS: A cross-sectional questionnaire-based study was conducted on various educational years of dental students in the College of Dentistry, Imam Abdulrahman Bin Faisal University, between February and April 2023. The students had performed at least one intraoral scan (Trios 3shape) and another conventional polyether impression for phantom casts/patients. The questionnaire assessed students' perceptions of digital impressions using a 5-point scale ranging from strongly agree to strongly disagree. Mann-Whitney U and Kruskal-Wallis tests were used to compare students' perceptions of digital impressions according to gender and educational year, respectively. RESULTS: The study included 122 students. About 55% were females with a mean (SD) age = 22.51 (3.36). Most students thought that digital impressions are faster and more user-friendly compared to conventional impressions. Significantly more female students thought that the handpiece was too big for intraoral use (p = 0.04) and that the process of the software was time-consuming and complicated. In general, higher educational year students were more satisfied with the digital impressions than lower educational year students. CONCLUSIONS: Digital impressions were perceived by most students as being faster and easier than conventional ones. However, male students and those with higher educational years showed better perception of digital impression.

3.
J Prosthodont ; 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39023016

ABSTRACT

PURPOSE: The present study evaluated the effects of the root portion design, segment (middle vs. apical), and part (die vs. cast) on the trueness of three-dimensional (3D)-printed removable die-cast complex. MATERIAL AND METHODS: The trueness of apical and middle segments of the root portion of 45 3D-printed removable dies and casts with three different root portion designs (n = 15) was assessed using a metrology-grade computer program. The three removable dies and cast designs (root form [RF], conical [CON], and cylindric [CYL]) were created using professional computer-aided manufacturing computer programs (DentalCAD 3.1 Rijeka, and InLab CAD 22.0), and manufactured using stereolithographic 3D printer (Form3; FormLabs, Somerville, MA). Subsequently, the 3D-printed removable dies and casts were scanned by a single operator with an intraoral scanner (PrimeScan; Dentsply Sirona, Charlotte, NC), and their respective standard tessellation language files were aligned and compared to master reference files in a metrology-grade computer program (Geomagic Control X; 3D systems, Rock Hill, NC). The root mean square (RMS) values of the middle and apical segments for each removable die and cast were calculated and analyzed using a mixed model including a repeated measure 3-way analysis of variance (ANOVA) and post-hoc stepdown Bonferroni-corrected pairwise comparisons (α = 0.05). RESULTS: A statistically significant 3-way interaction between factors was detected, suggesting that the part (removable die or alveolar cast) and their design affected the RMS values of their apical and middle root portion segment. (p = 0.045). The post-hoc analysis identified significant differences between RMS values of the apical segments of the CON and CYL removable dies (p = 0.005). Significant differences were observed between the middle and apical segments of the CON (p < 0.001) and RF removable die designs (p = 0.004). No statistically significant differences were noticed between the RMS of the different alveolar cast designs (p > 0.05). Significant differences were detected between the apical and middle segments of the same alveolar cast design (p < 0.05). CONCLUSIONS: For the manufacturing trinomial and 3D printing strategy used in the present study, the interaction of the part, design, and segment affected the trueness of removable dies and alveolar casts. The trueness was higher on the middle segment on removable dies and alveolar casts in all designs used, except for CYL removable dies, where the trueness difference between segments was small. Higher trueness values may be achieved with designs with simple apical segment geometries.

4.
Int J Implant Dent ; 10(1): 36, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39012381

ABSTRACT

PURPOSE: This study aims to evaluate the amount of distortion using computer-guided implant surgery with 3D printed surgical guides in limited edentulous spaces. MATERIALS AND METHODS: 25 bone level self-tapping implants (Straumann® BL and BLT) were randomly inserted in either distal or intercalary posterior mandibular edentulism using a fully digital protocol and 3D printed surgical guides. Amount of inaccuracy was evaluated after superimposing the 3 coordinates of virtually planned and final implant images, which were obtained using intra-oral scans and scan bodies. Four evaluation parameters were considered: origo-displacement, error depth, apical displacement and angle between the planned and the placed implant. RESULTS: The average of distortion was 0.71 mm for the origo-displacement, 0.36 mm for the error depth, 0.52 mm for the horizontal displacement and 3.34º for the error angle. CONCLUSION: The major reason of exclusion was CBCT artifacts. Results of this study were aligned with the results of previous studies concerning partially edentulous spaces. CAD/CAM manufacturing process did not result in significant distortion whilst the biggest part of distortions originated from the surgical process. The learning curve in computer-guided implant surgery presented an important source of inaccuracy.


Subject(s)
Jaw, Edentulous, Partially , Surgery, Computer-Assisted , Humans , Surgery, Computer-Assisted/methods , Prospective Studies , Jaw, Edentulous, Partially/surgery , Jaw, Edentulous, Partially/diagnostic imaging , Dental Implantation, Endosseous/methods , Dental Implantation, Endosseous/instrumentation , Female , Male , Middle Aged , Printing, Three-Dimensional , Dental Implants , Cone-Beam Computed Tomography
6.
Saudi Dent J ; 36(7): 1019-1024, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39035562

ABSTRACT

Background: Translucency and optical characteristics significantly affect the aesthetics of ceramic restorations. The introduction of new virgilite crystals to novel ceramic advanced lithium disilicate through a matrix firing process enhances the material's strength and aesthetic quality according to the manufacturer. Materials and Methods: Four types of CAD/CAM ceramics; lithium disilicate (LD), leucite reinforced (LR), advanced lithium disilicate (ALD), and zirconia-reinforced lithium silicate (ZLS) exposed to different staining solutions (tea, cola, coffee, and distilled water). Each ceramic type had 120 specimens, divided into subgroups based on thickness (0.5 mm, 1 mm, and 1.5 mm). Color changes (ΔE00) and translucency parameters (TP00) were measured after thermocycling, and spectrophotometry was employed to evaluate ΔE00 and TP00 after 1, 7, and 30 days of exposure to the staining solutions. Results: ZLS exhibited the lowest color stability, while lithium LD and ALD displayed the highest. Thickness significantly affected color stability, with 0.5 mm thickness showing the least change. The duration of exposure also impacted color changes, with 30 days causing the most significant shift. LD demonstrated the highest translucency. Coffee and tea induced more pronounced reductions in translucency and color stability compared to the control group. Conclusions: Material structure, thickness, staining solution, and exposure duration significantly influenced the color stability and translucency of CAD/CAM ceramics, with LD and ALD demonstrating superior color stability and LD exhibiting the highest translucency.

7.
Cureus ; 16(7): e64941, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39035587

ABSTRACT

The advent of digital workflows has revolutionized oral rehabilitation, offering excellent prosthesis and restoration adaptation while reducing work time. This case report aims to describe a full-arch rehabilitation protocol using mucosa-supported prostheses through a digital workflow. The technique begins with scanning the upper jaw and taking an impression of the lower jaw, followed by scanning to create a digital cast. Next, border molding and the final impression of both arches are performed using a closed-mouth technique, during which the patient is guided to perform lateral and protrusive movements. Subsequently, intraoral scanning of the occlusion and both impressions is conducted, leading to the design of the final dentures with the established occlusion. Finally, the dentures are printed in Formlabs resin specifically designed for dentures. The digital workflow facilitates the manufacturing of mucosa-supported full-arch prostheses effectively. This method allows for the adjustment of the vertical dimension of occlusion, ensures excellent adaptation of the prosthesis to the soft tissues, and provides aesthetic satisfaction for the patient. Additionally, it reduces the number of sessions required to install the definitive prosthesis.

8.
J Esthet Restor Dent ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38979970

ABSTRACT

OBJECTIVE: In oral rehabilitation, a full mouth minimal invasive treatment can represent a major challenge for the patient and the dentist. The purpose of this article is to present a new technique to restore eroded teeth and recover the vertical dimension with a simple and predictable technique. CLINICAL CONSIDERATIONS: Occlusal tabletop restorations are a suitable conservative option to restore anatomy and vertical dimension augmentation but highly sensitive. The cementation of those restorations without stable landmarks, the cement excess removal, the insertion path, or the time needed are some of the difficulties can be faced. Now a days with the new CAD-CAM techniques is possible to develop a new occlusal tabletop manufacturing alternative utilizing 3D-printed technology by unifying the restorations with a customized connector that allows us to print several onlays at same time, as a single object, also being cemented at once. CONCLUSIONS: This protocol reduces the technique sensitivity of a vertical dimension oral rehabilitation process, reduce the chair time, enhancing the patient-comfort and delivers a unique way to restore dental lost anatomy as a definitive or temporary way with printing materials. CLINICAL SIGNIFICANCE: With the advent of new CAD-CAM 3D printing materials, which are increasingly versatile and gaining favor among clinicians, it is now possible to address complex clinical situations with greater predictability. This technology enables the development of treatment solutions that are both effective and efficient, consequently reducing clinical time for the patient.

9.
Clin Oral Investig ; 28(7): 413, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38965139

ABSTRACT

OBJECTIVES: This study compares the biofilm inhibition effects of denture cleaning tablets, carvacrol, and their combined use against Candida albicans on denture bases produced with different techniques. Additionally, the surface roughness and contact angles of these denture bases were evaluated. MATERIALS AND METHODS: Test samples were prepared from four different denture base materials (cold-polymerized, heat-polymerized, CAD/CAM milling, and 3D-printed). The surface roughness and contact angles of the test samples were measured using a profilometer and goniometer, respectively. For the evaluation of biofilm inhibition, samples were divided into 5 subgroups: Corega and carvacrol, separately and combined treatments, positive (inoculated with C. albicans) and negative control (non-inoculated with C. albicans, only medium). Biofilm mass was determined using the crystal violet method. An additional prepared test sample for each subgroup was examined under scanning electron microscopy (SEM). RESULTS: The surface roughness values of the 3D-printed test samples were found to be statistically higher than the other groups (P < .001). The water contact angle of all test materials was not statistically different from each other (P > .001). Corega and carvacrol, separately and combined, significantly decreased the amount of biofilm on all surfaces (P < .0001). Treatment of corega alone and in combination with carvacrol to the 3D-printed material caused less C. albicans inhibition than the other groups (P < .001; P < .05). CONCLUSIONS: The surface roughness values of all test groups were within the clinically acceptable threshold. Although Corega and carvacrol inhibited C. albicans biofilms, their combined use did not show a synergistic effect. CLINICAL RELEVANCE: Carvacrol may be used as one of the disinfectant agents for denture cleaning due to its biofilm inhibition property.


Subject(s)
Biofilms , Candida albicans , Cymenes , Denture Bases , Denture Cleansers , Materials Testing , Microscopy, Electron, Scanning , Surface Properties , Biofilms/drug effects , Candida albicans/drug effects , Denture Bases/microbiology , Cymenes/pharmacology , Denture Cleansers/pharmacology , Printing, Three-Dimensional , Tablets
10.
Cureus ; 16(6): e62021, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38989363

ABSTRACT

Maintenance of biological width serves as a primary factor in periodontal-restorative relationships. Crown lengthening (CL) is a technique to prevent violation of biological width, with the laser method offering the advantage of surgical and patient-related outcomes. Laser CL with retraction helps with the excision of tissues, increasing the CL, maintaining the gingival contour with adequate exposure to the finish line to record the tooth preparation features. This helps to achieve the functional and esthetic outcomes essential for restorative dentistry. The marginal fit, contour, and adaptation of the crown can be further enhanced by computer-aided design and computer-aided manufacturing (CAD/CAM) technology improving patient and clinical outcomes. Hence, this case report aims to indulge the laser-assisted procedures and CAD/CAM technology to fabricate and deliver a zirconia crown maintaining the periodontal-restorative factors.

11.
Korean J Orthod ; 54(4): 257-263, 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39048921

ABSTRACT

Objective: Lingual fixed retainers, made from 0.0175-inch 3-strand twisted stainless steel wire (TW) and 0.016 × 0.022-inch straight rectangular wire (RW), are generally used in clinical practice. This study aimed to calculate their accuracy by comparing the discrepancy between computer-aided customized retainers made from these two types of wires. Methods: Eleven orthodontic patients were selected, resulting in 22 maxillary and mandibular three-dimensional printing dental models. Two types of lingual fixed retainers were bonded from canine to canine. To determine the accuracy, five points were chosen for each model, resulting in 110 selected points. The absolute values of the distances on the x-, y-, and z-axes were measured to compare the accuracy of the two types of computer-aided retainers. Results: The accuracy of the two types of retainers did not differ significantly in the x- and z-axes, but only in the y-axis (P < 0.01), where RW-fixed retainers exhibited a slightly but significantly increased distance compared to the TW. Conclusions: Both types of retainers showed high accuracy; however, RW had a slight but statistically significant difference along the y-axis compared with TW. This type of computer-aided design/computer-aided manufacturing bending machine is limited to two dimensions, and the dental arch is curved. Therefore, RW may require slight manual adjustment by the practitioner after manufacturing.

12.
J Prosthodont Res ; 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39034113

ABSTRACT

PURPOSE: This study aimed to analyze how the wall thickness of 3D-printed hollow zirconia teeth affects shape accuracy. METHODS: Datasets with measurement points were created for different artificial teeth resembling the mandibular right first molar (Geomagic Design X, 3D Systems). Reference distances were 9.8 mm for mesio-distal direction (M-D), 10.9 mm for bucco-lingual direction (B-L), 7.0 mm for MB-BB and DB-BB, and 4.5 mm for ML-LB and DL-LB. The outer geometry was identical for all artificial teeth with wall thicknesses of 0.30, 0.50, 0.75, and 1.00 mm. Twenty zirconia teeth were fabricated using a 3D printer (CeraFab 7500 Dental, Lithoz) for each group and sintered before support removal. After performing analog distance measurements using a micrometer screw, the digital distance measurements and angular deviations between measurement points on 3D scans were analyzed. Possible effects were investigated using nonparametric ANOVA, followed by Tukey's honest significant difference (HSD) test for multiple comparisons. RESULTS: The shape accuracy was acceptable for artificial teeth with wall thicknesses of ≥0.5 mm. The largest distance deviation was observed for a wall thickness of 0.3 mm. In particular, DB-BB showed a median deviation of >56.2 µm, which is significantly larger than that for other test groups, ranging from 7.4-9.5 µm (P < 0.05). In most cases, angular deviations were the largest for teeth with 0.3-mm wall thickness (11.6°) and remained below 5.0° for the other test groups. CONCLUSIONS: Acceptable accuracy was obtained for artificial teeth with wall thicknesses of at least 0.5 mm.

13.
Dent J (Basel) ; 12(7)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-39056986

ABSTRACT

BACKGROUND: Due to rapid changes in dental practice, digital technologies have become prominent in undergraduate dental education at German universities in recent years. This shift has prompted a re-evaluation of content as well as teaching methods, particularly in courses where students are prepared for patient treatment. Traditional training on standardized models with resin teeth cannot cover the complexity of individual dental arch configuration encountered in patient situations. This study explores the use of 3D printing technology to create individualized models for prosthetic treatment simulations, aiming to evaluate students' feedback towards their experience with this training setting. METHODS: First, the study describes the design and fabrication of individualized models with exchangeable teeth based on intraoral scans, mounted on connected plates with distance holders that can be fixed to standard phantom heads. Second, students provided feedback through a questionnaire, assessing various aspects such as the effectiveness of the 3D-printed models compared to traditional frasaco models for preparation exercises. RESULTS: The results indicated that the design of the realized models was feasible for preparation training (question no. 4: 93% positive rating) and showed positive perceptions of the 3D-printed models, with students finding them effective for preparation exercises and beneficial in bridging the gap between simulation and real patient situations (question no. 6: 69% positive rating). CONCLUSIONS: The study suggests that 3D printing technology offers a valuable tool in dental education, providing realistic and patient-specific scenarios for students to enhance their skills and readiness for clinical practice. Further improvements in material properties in hand with cost-effective approaches are essential for widespread implementation.

14.
Dent J (Basel) ; 12(7)2024 Jun 29.
Article in English | MEDLINE | ID: mdl-39056989

ABSTRACT

Purpose: To evaluate, in vitro, the efficiency of a novel apparatus to test the adherence and penetration of bacteria on different membranes for guided regeneration. Methodology: To create the 3D device, Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) systems were used. Three types of biomaterials were tested (n = 6): (DT) a collagen membrane; (DS) a polymer membrane; and (LP) a dense polytetrafluoroethylene barrier. The biomaterials were adapted to the apparatuses and challenged with two different monospecies bacterial culture of A. actinomycetemcomitans b and S. mutans. After 2 h, bacterial adherence and penetration were quantified by counting the number of colony-forming units (CFUs). Two specimens from each group were used for image analysis using Confocal Laser Scanning Microscopy. Statistical analysis was performed. Findings: The DS group had a higher adherence of S. mutans compared to A. actinomycetemcomitans b (p = 0.05). There was less adherence of A. actinomycetemcomitans b in the DS group, compared to the LP (p = 0.011) and DT (p < 0.001) groups. Only the membranes allowed penetration, which was blocked by barriers. The DT group allowed a greater penetration of S. mutans to occur compared to A. actinomycetemcomitans b (p = 0.009), which showed a higher penetration into the DS membranes compared to S. mutans (p = 0.016). The penetration of A. actinomycetemcomitans b through DS was higher compared to its penetration through DT and LP (p < 0.01 for both). DT and DS allowed a greater penetration of S. mutans to occur compared to LP, which prevented both bacterial species from penetrating. Conclusion: The apparatus allowed for the settlement and complete sealing of the biomaterials, enabling standardization.

15.
J Funct Biomater ; 15(7)2024 Jun 22.
Article in English | MEDLINE | ID: mdl-39057293

ABSTRACT

Fracture resistance is an important parameter used to predict the performance of indirect dental restorations. The purpose of this in vitro study was to assess the fracture load of posterior milled nanoceramic crowns, in comparison with the lithium disilicate crowns, after fatigue loading, for two different restoration occlusal thicknesses. Forty test metal dies were fabricated by duplicating a master metal model consisting of an anatomic abutment preparation of the maxillary first premolar for a single crown. The dies were divided into two groups of 20 each for the fabrication of nanoceramic (Lava Ultimate) and lithium disilicate (IPS e.max CAD) single crowns. Each material group was further divided into two sub-groups of 10 dies each, based on crown occlusal thickness, of 0.5-mm and 0.75-mm (n = 10). Dental Type V stone dies poured from polyvinyl siloxane impressions of the test metal dies were laboratory scanned in order to design and mill 40 ceramic crowns. The crowns were cemented on to the test metal dies with a self-adhesive resin luting cement. All crowns were thermocycled (2500 cycles) and mechanically loaded (250,000 cycles) in a chewing simulator followed by static loading until failure, and the values noted. The data were statistically analyzed by 2-way ANOVA and Tukey HSD post-hoc multiple comparison tests (α = 0.05). The mean fracture loads ranged from 1022 to 1322 N for nanoceramic crowns and from 1145 to 1441 N for the lithium disilicate crowns. Two-way ANOVA revealed insignificant differences between the nanoceramic and lithium disilicate crowns (p > 0.05) in terms of fracture load. Significant differences were noted in the fracture resistance of crowns based on occlusal thickness (303 N; p = 0.013) regardless of the material used. Multiple comparisons by Tukey HSD post-hoc test showed insignificant differences between the four material-occlusal thickness groups (p > 0.05). The nanoceramic crowns were found to be comparable with lithium disilicate crowns in terms of fracture load. The mean fracture loads of all of the tested crowns were within the normal physiological masticatory load limits. Based on the fracture-resistance results, nanoceramic crowns seem to be suitable for clinical use for the tested occlusal thicknesses.

16.
Clin Oral Investig ; 28(8): 417, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38972945

ABSTRACT

OBJECTIVES: The treatment of fractures prioritizes the restoration of functionality through the realignment of fractured segments. Conventional methods, such as titanium plates, have been employed for this purpose; however, certain limitations have been observed, leading to the development of patient-specific plates. Furthermore, recent advancements in digital technology in dentistry enable the creation of virtual models and simulations of surgical procedures. The aim was to assess the clinical effectiveness of patient-specific plates utilizing digital technology in treating mandibular fractures compared to conventional titanium plates. MATERIALS AND METHODS: Twenty patients diagnosed with mandibular fractures were included and randomly assigned to either the study or control groups. The surgical procedure comprised reduction and internal fixation utilizing patient-specific plates generated through virtual surgery planning with digital models for the study group, while the control group underwent the same procedure with conventional titanium plates. Assessment criteria included the presence of malunion, infection, sensory disturbance, subjective occlusal disturbance and occlusal force in functional maximum intercuspation (MICP). Statistical analysis involved using the Chi-square test and one-way repeated measures analysis of variance. RESULTS: All parameters showed no statistically significant differences between the study and control groups, except for the enhancement in occlusal force in functional MICP, where a statistically significant difference was observed (p = 0.000). CONCLUSION: Using patient-specific plates using digital technology has demonstrated clinical effectiveness in treating mandibular fractures, offering advantages of time efficiency and benefits for less experienced surgeons. CLINICAL RELEVANCE: Patient-specific plates combined with digital technology can be clinically effective in mandibular fracture treatment.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Fractures , Titanium , Humans , Mandibular Fractures/surgery , Titanium/chemistry , Male , Female , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Adult , Treatment Outcome , Middle Aged , Computer-Aided Design , Surgery, Computer-Assisted/methods
17.
Microsc Res Tech ; 2024 Jul 14.
Article in English | MEDLINE | ID: mdl-39003769

ABSTRACT

To assess the fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ultratranslucent multilayered zirconia (5Y-YZP) veneers with varying facial thickness. Sixty translucent zirconia veneers were designed and milled using a chairside CAD/CAM system for maxillary central incisors. The butt joint incisal veneer tooth preparations consisted of 1.00 mm incisal reduction, 0.40 mm chamfer margin, and three different facial reductions; 0.50, 0.75, and 1 mm, respectively. The ceramic veneers were cemented to printed resin dies and subjected to thermal cycling. Subsequently, the restorations were loaded with compressive loading force, and fracture occurrences were recorded. Scanning electron microscope (SEM) images of the fractured specimens were captured. The fracture resistance varied among the veneers with different facial thicknesses. Ultratranslucent zirconia veneers with a facial thickness of 1.00 mm exhibited the highest fracture resistance values (742.15 N), followed by those with 0.75 mm facial thickness (673 N). Minimally invasive veneers with 0.50 mm thickness displayed similar fracture resistance as thicker veneers with 0.75 mm. However, veneers with 1.00 mm thickness displayed the highest values. SEM fracture patterns for 0.50 and 0.75 mm display similar and fewer crack lines than 1.00 mm veneers. RESEARCH HIGHLIGHTS: Minimally invasive zirconia veneers exhibit similar fracture resistance to thicker veneers.

18.
J Prosthodont ; 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39008343

ABSTRACT

PURPOSE: To explore the clinical application of one-piece polyetheretherketone (PEEK) removable partial dentures (RPDs) fabricated using a novel digital workflow and to evaluate their weights and fits in vivo and patient satisfaction. MATERIALS AND METHODS: Fifteen cases with posterior partially edentulous situations were selected, and each patient received two types of RPDs, including a novel digital workflow (test group) and a conventional workflow (control group). For the test group, one-piece RPDs were designed through three-dimensional (3D) methods by scanning stone casts and fabricated by milling PEEK discs. Each RPD was weighed. The gaps between the oral tissue and RPDs in each group were duplicated using a polyvinylsiloxane (PVS) replica and measured by 3D analysis. A visual analog scale (VAS) was used to evaluate the patient's satisfaction. Paired t-tests were used to compare the differences in the weight, the gaps of each RPD, and VAS values between the two groups. One-way analysis of variance tests was used to compare the differences in the gap among different components in each group. RESULTS: The RPD in the test group weighed less than that in the control group (p < 0.01). No statistically significant differences in the gaps of denture bases and rests (p > 0.05) were found between the two groups, but the gaps of major connectors in the test group were significantly smaller than in the control group (p < 0.05). The VAS scores for comfortableness and masticatory efficiency were not significantly different between the two groups (p > 0.05) but the scores for the aesthetic appearance of the clasps in the test group were significantly higher than that in the control group (p < 0.05). CONCLUSIONS: One-piece PEEK RPDs manufactured using a novel digital workflow weighed less than conventional RPDs and exhibited a clinically acceptable internal fit. Although the aesthetic appearance of the PEEK clasps was superior to the control, there is still room for improvement.

19.
Materials (Basel) ; 17(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38998221

ABSTRACT

A common challenge encountered with both traditional and digitally produced dentures involves the extraction of artificial teeth from the denture base. This narrative review seeks to present an updated perspective on the adherence of synthetic teeth for denture base materials, employing diverse methods. Dental technicians often employ chemical approaches and mechanical techniques (including abrasion, laser treatment, and abrasive blasting) to augment the retention of denture teeth. However, the efficacy of these treatments remains uncertain. In certain instances, specific combinations of Denture Base Resin (DBR) materials and artificial teeth exhibit improved performance in conventional heat-cured dentures following these treatments. The primary reasons for failure are attributed to material incompatibility and inadequate copolymerization. As new denture fabrication techniques and materials continue to emerge, further research is imperative to identify optimal tooth-DBR combinations. Notably, 3D-printed tooth-DBR combinations have demonstrated reduced bond strength and less favorable failure patterns, while utilizing milled and traditional combinations appears to be a more prudent choice until advancements in additive manufacturing enhance the reliability of 3D-printing methods.

20.
Materials (Basel) ; 17(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38998243

ABSTRACT

Dental technology has developed materials for prosthetics that are very similar to natural teeth and offer a good balance between durability and esthetics; however, some of these materials are not very color-stable under the influence of external factors. Therefore, the aim of this study is to determine and compare the color change (∆E00) of different esthetic monolithic monochromatic CAD/CAM materials after they have been thermocycled and treated with staining solutions. The color parameters were determined using a spectrophotometer on a white and black background. Five CAD/CAM materials were used for this study-CAD/CAM nanoceramic (GC Cerasmart270), CAD/CAM lithium disilicate ceramic (IPS e.max CAD), CAD/CAM polymer (Telio CAD), CAD/CAM composite (Tetric CAD) and CAD/CAM polymer-infiltrated ceramic (Vita Enamic). The test specimens produced were divided into groups and were thermocycled in distilled water. They were then stored for four weeks at 37 °C in either distilled water as a control liquid, black tea, instant coffee or red wine. The aim is also to evaluate the color changes as a function of the exposure time of the staining solutions. The results obtained were analyzed statistically. All CAD/CAM materials tend to discolor to varying degrees. Among the factors contributing to discoloration, red wine proved to be the most significant influencing factor. The conclusion from the results is that the color change is influenced by the type of material, the staining solution, the sample thickness, the color background and the aging time.

SELECTION OF CITATIONS
SEARCH DETAIL