Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
J Vasc Surg ; 79(2): 198-206.e15, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37967588

ABSTRACT

OBJECTIVE: We assessed the suitability of two triple branch arch devices (aBranch) (Terumo aortic and Cook Medical) and a balloon-expandable covered stent (VBX, W. L. Gore & Associates, Johnson & Johnson) to incorporate the brachiocephalic trunk (BCT) in a cohort previously treated with hybrid thoracic endovascular repair (TEVAR). METHODS: This is a single-center, retrospective, all-comers, preclinical suitability study. We conducted an analysis of preoperative computed tomography scans in surgical patients between 1999 and 2022 in a single vascular surgery unit. The primary outcome was the aortic suitability of aBranch devices and VBX as mating stent for BCT in previous hybrid TEVAR. Hybrid repair of the aortic arch included TEVAR, fenestrated or branched TEVAR associated with any surgical debranching of the supra-aortic trunks and chimney TEVAR with proximal landing in zones 0 to 2. Secondary outcomes included (i) suitability assessment when excluding minor instruction for use (IFU) criteria, (ii) a comparison of suitable and nonsuitable patients, (iii) risk factors analysis for nonsuitability, and (iv) a description of the exclusion causes. RESULTS: During the study period, 120 patients were treated. Among elective patients (n = 73), the suitability of any aBranch was 82.2% (60/73) and VBX was suitable in 64.4% of BCTs (47/73). The aBranch suitable patients had a significantly longer sinotubular-BCT length (P = .017) and smaller distal ascending aorta (P = .043) as compared with nonsuitable ones. The suitability of Terumo Aortic and Cook Medical devices was 52.1% (38/73) and 46.6% (34/73), respectively. When minor IFU criteria were ignored, suitability increased to 82.2% (60/73) and 63.0% (46/73), respectively. Left common carotid artery diameter and sinotubular-BCT length were significant nonsuitability risk factors for Terumo Aortic aBranch in multivariable analysis. No associations were found for Cook Medical device. The outcomes were tested in the entire cohort demonstrating a global suitability of 82.9%, increasing to 86.3% when ignoring minor IFUs. VBX was anatomically suitable to use in BCT in 73.2% of patient BCTs. CONCLUSIONS: aBranch devices are anatomically suitable in a vast majority of patients (86%) undergoing hybrid TEVAR. The innominate artery seems eligible for incorporation with VBX in almost two-thirds of patients. This mating stent may help to overcome some minor IFU restrictions.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Endovascular Aneurysm Repair , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Retrospective Studies , Endovascular Procedures/adverse effects , Prosthesis Design , Stents , Treatment Outcome
2.
Cureus ; 15(11): e48910, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38106796

ABSTRACT

A 46-year-old male developed a Stanford type B aortic dissection. At age 48, he underwent left open thoracic descending aorta replacement because of the enlargement of the descending thoracic aorta. At 51 years old, he underwent abdominal aorta replacement because of ischemia in the right lower extremity and the enlargement of an abdominal aortic aneurysm. The septum between the true and false lumens was submitted to histopathological examination, which revealed bilateral intimal tissue with the tunica media lying in between.

3.
Cardiovasc Intervent Radiol ; 46(2): 249-254, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36319711

ABSTRACT

OBJECTIVE: To describe the feasibility and outcomes of endovascular repair of distal aortic arch aneurysms using a patient-specific stent graft with a pre-loaded single retrograde left subclavian artery (LSA) branch stent graft. METHODS: We reviewed the clinical data and outcomes of consecutive patients enrolled in an ongoing prospective, non-randomized physician-sponsored investigational device exemption study to evaluate the outcomes of endovascular aortic arch repair using patient-specific arch branch stent grafts (William Cook Europe, Bjaeverskov, Denmark) between 2019 and 2022. All patients received a design with triple-wide scallop and a single retrograde LSA branch with a pre-loaded catheter. RESULTS: There were five male patients with median age of 77 years old (72-80) treated using the single LSA branch stent graft. Technical success was achieved in all patients. Median operating time, fluoroscopy time, and total radiation dose area product were 103 (78-134) minutes, 26 (19-39) minutes, and 123 (71-270) mGy.cm2, respectively. There were no 30-day or in-hospital mortality, neurological or other major adverse events (MAEs). During median follow-up of 21 (20-27) months, all patients were alive with patent LSA branches, except for one who died of COVID-19 complications. There was no branch instability or secondary interventions. CONCLUSION: This early feasibility study demonstrates successful endovascular repair of distal aortic arch aneurysms using a patient-specific stent graft with single retrograde LSA branch without technical failures, mortality or neurological events. Larger clinical experience and longer follow-up are needed to determined effectiveness of this approach in patients who need endovascular repair with proximal extension into Zone 2.


Subject(s)
Aneurysm, Aortic Arch , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , COVID-19 , Endovascular Procedures , Aged , Humans , Male , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Feasibility Studies , Prospective Studies , Prosthesis Design , Stents/adverse effects , Subclavian Artery/diagnostic imaging , Subclavian Artery/surgery , Time Factors , Treatment Outcome
4.
J Card Surg ; 37(7): 2152-2154, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35451125

ABSTRACT

A patient who underwent candy-plug insertion in the year 2016 developed type 1B endoleak with rapid enlargement of distal descending thoracic aortic aneurysm in the year 2021 despite the initial successful false lumen occlusion and thrombosis. Open conversion with Crawford extent 3 thoracoabdominal aortic replacement was performed successfully and the patient was discharged home without any major complications.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Humans , Prosthesis Design , Stents , Treatment Outcome
5.
J Vasc Surg Cases Innov Tech ; 7(2): 344-349, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34041426

ABSTRACT

We report the case of a physician-modified four-fenestration endograft for the emergent treatment of a 65-year-old patient with postdissection thoracoabdominal aneurysm deemed unfit for open surgery. The patient, after elective thoracic endovascular aneurysm repair as the first stage of a preplanned two-stage total thoracoabdominal endovascular repair, presented acute onset of dyspnea and thoracic pain. Computed tomography angiography (CTA) showed signs of contained rupture. The Valiant Navion thoracic endograft was used for the creation of a physician-modified four-fenestration stent graft. A diameter-reducing wire technique was used to constrain posteriorly the prosthetic graft and to allow intraprocedural partial deployment. The modified stent graft was finally folded into its original sheath and implanted; four balloon-expandable stent grafts were used as bridging components. Postoperative CTA showed a residual type IIIc endoleak that was treated with a relining procedure 4 months later. At the 20-month follow-up, the patient is alive and well and CTA shows complete seal of the thoracic aneurysm with persisting small type IIIc endoleak in the abdominal aneurysm. A physician-modified endograft can be considered a valuable option in case of urgent treatment of TAAA in patients deemed unfit for open surgery when off-the-shelf devices are not available or contraindicated.

6.
J Vasc Surg ; 74(4): 1055-1065.e4, 2021 10.
Article in English | MEDLINE | ID: mdl-33865950

ABSTRACT

OBJECTIVE: We evaluated the outcomes of total endovascular aortic arch repair using three-vessel inner branch stent-grafts for aneurysms and chronic dissections. METHODS: We reviewed the clinical data and outcomes of consecutive patients treated by total endovascular aortic arch repair at eight academic centers using three-vessel inner branch stent-grafts (William Cook Europe, Bjaeverskov, Denmark) from 2016 to 2019. All patients received three-vessel designs with two antegrade and one retrograde inner branch, which was used to incorporate the innominate, left common carotid, and left subclavian arteries. The antegrade inner branches were accessed via a carotid or an upper extremity approach. A preloaded catheter was used for access to the retrograde left subclavian artery branch via a transfemoral approach. The endpoints were technical success, mortality, major adverse events, any stroke (minor or major) or transient ischemia attack, secondary interventions, target vessel patency, target vessel instability, aneurysm-related mortality, and patient survival. RESULTS: A total of 39 patients (31 men [79%]; mean age, 70 ± 7 years) had undergone treatment of 14 degenerative (36%) and 25 chronic (64%) postdissection arch aneurysms. The clinical characteristics included American Society of Anesthesiologists class ≥III in 28 patients (95%) and previous median sternotomy for ascending aortic repair in 28 patients (72%). The technical success rate was 100%. Two patients had died in-hospital or within 30 days (5%), and two patients had experienced a stroke (one minor). The combined mortality and any stroke rate was 8% (n = 3). Major adverse events occurred in 10 patients (26%), including respiratory failure in 4 (10%) and estimated blood loss >1 L, myocardial infarction, and acute kidney injury in 2 patients each (5%). The median follow-up was 3.2 months (interquartile range, 1-14 months). Of the 39 patients, 12 (31%) required secondary interventions to treat vascular access complications in 5, endoleak in 6 (three type II, one type Ic, one type Ia/Ib, one type IIIa), and target vessel stenosis in 1 patient. At 1 year, the primary and secondary patency rates and freedom from target vessel instability were 95% ± 5%, 100%, and 91% ± 5%, respectively. Freedom from aortic-related mortality and patient survival was 94% ± 4% and 90% ± 6%, respectively. CONCLUSIONS: The findings from the present multicenter global experience have demonstrated the technical feasibility and safety of total endovascular aortic arch repair for aneurysms and chronic dissections using three-vessel inner branch stent-grafts. The mortality and stroke rates compare favorably with those after open surgical repair in a higher risk group of patients. However, the rate of secondary interventions was high (31%), emphasizing need for greater experience and longer follow-up.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Chronic Disease , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Feasibility Studies , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
7.
Postgrad Med ; 133(2): 217-222, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32940109

ABSTRACT

INTRODUCTION: The conservative management of a Stanford type B aortic dissection (TBD) is optimal blood pressure management, cardiac rehabilitation, and progressive return to activities of daily living (ADL) while preventing advancing dissection and aortic dilation. Recent case reports indicate higher levels of activity may be safe; however, the exercise parameters for chronic TBD conditions span a broad range and the research is limited. CASE PRESENTATION: The clinical presentation and outpatient cardiac and physical rehabilitation program for a 61-year-old male with a chronic TBD from his subclavian artery to common iliac arteries is presented. The exercise protocol was developed and based on the available literature for the management of chronic aortic diseases. Eighteen months after the patient's acute TBD event, he began an exercise protocol designed to address the sport specific functional deficits related to his recreational activities. The program incorporated a variety of exercises from resistance training to cardiovascular exercise and high interval training. The therapeutic goals included restoration of cardiac fitness and improvement of core stability and appendicular strength, ultimately aiming toward a potential to return to recreational sport involving short duration, high intensity activity. CONCLUSION: In conjunction with the appropriate anti-hypertensive medication treatment, understanding the concepts of aortic hemodynamics as they relate to exercise can serve as a guideline for clinicians in developing an individualized exercise program for their TBD patients. Moreover, these physical training programs may include particular exercise guidelines beyond general recommendations of light to moderate cardiovascular activities.


Subject(s)
Aortic Dissection , Cardiac Rehabilitation/methods , High-Intensity Interval Training/methods , Hypoglycemic Agents/administration & dosage , Patient Care Planning , Activities of Daily Living , Aortic Dissection/diagnosis , Aortic Dissection/drug therapy , Aortic Dissection/physiopathology , Aortic Dissection/rehabilitation , Aortic Aneurysm/diagnosis , Aortic Aneurysm/drug therapy , Aortic Aneurysm/physiopathology , Aortic Aneurysm/rehabilitation , Cardiorespiratory Fitness/physiology , Chronic Disease , Exercise Therapy/methods , Humans , Male , Middle Aged , Treatment Outcome
8.
J Thorac Cardiovasc Surg ; 162(5): 1467-1473, 2021 Nov.
Article in English | MEDLINE | ID: mdl-32199664

ABSTRACT

BACKGROUND: The treatment of complicated chronic aortic dissection remains controversial. We previously reported encouraging early results with the stent-assisted balloon-induced intimal disruption and relamination of aortic dissection (STABILISE) technique for treating complicated acute aortic dissections. However, to date there have been no specific reports on the treatment of complicated chronic aortic dissections with this technique. The aim of this study was to assess the results of the STABILISE technique to treat complicated chronic aortic dissection. METHODS: A single-center prospectively maintained database enrolled all patients hospitalized for aortic dissection at our institution. Inclusion criteria for the STABILISE procedure at the chronic stage of dissection (>3 months) were postdissection aneurysm with a diameter >55 mm or rapid aortic diameter growth >5 mm/6 months. We reviewed all patients treated for complicated chronic aortic dissection with the STABILISE technique. Patients were monitored at 3, 6, and 12 months and annually thereafter with clinical, imaging, and laboratory studies. Outcome analyses included survival, rupture, spinal cord ischemia, endoleak, morbidity (cardiac, renal, or pulmonary), reinterventions, false lumen patency, and aneurysm growth. RESULTS: Between September 2015 and December 2018, 17 patients underwent a STABILISE procedure for complicated chronic aortic dissection of the descending aorta. Fifteen patients were treated for remaining chronic distal thoracoabdominal aortic dissection after acute DeBakey type I aortic dissection repair, and 2 patients were treated for chronic type B aortic dissection. The median patient age was 61 years (range, 46-67 years). The median interval between the onset of acute symptoms and the procedure was 9 months (range, 3-67 months). Indications for the STABILISE procedure were a rapidly growing dissected aortic diameter >5 mm/6 months in 13 patients and aneurysmal evolution of the descending thoracic aorta >55 mm in 4 patients. There were no cases of in-hospital death, stroke, spinal cord ischemia, ischemic colitis, or renal failure necessitating dialysis. The median duration of follow-up was 17 months (range, 5-28.5 months). At the last computed tomography scan, 15 patients (88%) had complete false lumen thrombosis of the treated thoracoabdominal aorta down to the renal arteries. None of the patients had aortic growth at treated thoracoabdominal aorta level. One patient developed a proximal type 1 endoleak and required reintervention. Regarding the untreated aortoiliac level below the renal arteries, 11 patients had persistent false lumen patency, and 1 patient developed a common iliac artery aneurysm. All the other patients had stable infrarenal aortoiliac diameters. No late deaths were reported during follow-up. CONCLUSIONS: The STABILISE technique is a safe and effective means of performing immediate, complete aortic remodeling of the thoracoabdominal aorta in patients with complicated chronic aortic dissection, stabilizing the diameter of the dissected aorta.


Subject(s)
Angioplasty, Balloon/instrumentation , Aortic Aneurysm, Thoracic/therapy , Aortic Dissection/therapy , Stents , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Angioplasty, Balloon/adverse effects , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Chronic Disease , Databases, Factual , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome , Vascular Remodeling
9.
J Vasc Surg ; 73(5): 1573-1582.e1, 2021 05.
Article in English | MEDLINE | ID: mdl-33068767

ABSTRACT

OBJECTIVE: Chronic aortic dissection with aneurysm development that includes the aortic arch and/or thoracoabdominal aorta (TAAA) is traditionally treated with open or hybrid surgery. Total endovascular treatment with fenestrated and branched aortic repair (F/B-EVAR) has recently been introduced as a less invasive alternative. The aim was to report the short- and midterm outcomes from a single tertiary vascular center. METHODS: All patients with chronic aortic dissection treated with F/B-EVAR from 2010 to 2019 at Uppsala University Hospital were identified. Perioperative and postoperative parameters were analyzed, with focus on short- (<30 days) and midterm survival, complication, and reintervention rates. RESULTS: F/B-EVAR was performed on 26 patients (median age, 63 years; range, 33-87 years; 18 men; median aortic diameter, 70 mm; range, 50-98 mm); with a median follow-up of 23 months (range, 0.5-118.0 months). One patient underwent both arch and TAAA repair. Overall, 13 arch repairs (arch group) after type A (n = 8) and type B (n = 5) dissection (all elective) were performed, and 14 TAAA repairs (TAAA group) after type A (n = 5) and type B (n = 9) dissection (one rupture). A total of 72 aortic branches were targeted (22 arch, 50 TAAA). Short-term technical success was achieved in 24 of 27 procedures (89%). Failures were related to one intraoperative retrograde type A dissection (RTAD) requiring open conversion (arch group), one persistent type IC endoleak on completion angiography (arch group), and one persistent type III endoleak (TAAA group). Mortality was 4% (n = 1) at 30 days and related to a second RTAD that occurred after discharge and was found on autopsy. Both RTADs occurred in patients with chronic type B dissection undergoing fenestrated arch repair. Paraplegia occurred in three cases (two arch, one TAAA) (11%), none permanent, and stroke in three cases (one arch, one TAAA) (11%); one was permanent. In the midterm, endoleaks were detected in 12 patients (44%); persistent false lumen flow (n = 3), type IB (n = 1), type IC (n = 3), type II (n = 7), and type IIIC (n = 2). The 3-year survival (Kaplan-Meier) of the arch repair was 75% and for the TAAA, 93%. Freedom from reintervention at 3 years were 100% for arch repairs and 48% for TAAA. In patients with a follow-up of more than 6 months (n = 23), all had stable or decreased aortic diameters and complete false lumen thrombosis at the level of stent graft was present in 65% (n = 15). CONCLUSIONS: Endovascular treatment of postdissection aneurysms is feasible, with acceptable short-term and midterm outcomes. RTAD after fenestrated and branched endovascular arch repair warrants caution when performed on patients with native ascending aortas, and reinterventions are frequent in TAAA repair.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Adult , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Chronic Disease , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Postoperative Complications/mortality , Postoperative Complications/surgery , Prosthesis Design , Reoperation , Retrospective Studies , Risk Factors , Sweden , Time Factors , Treatment Outcome
10.
J Vasc Surg ; 73(3): 797-804, 2021 03.
Article in English | MEDLINE | ID: mdl-32682068

ABSTRACT

OBJECTIVE: Open repair of thoracoabdominal aortic aneurysms (TAAAs) that have developed secondary to chronic dissection (CD) is often more complex than repair of degenerative aneurysms (DAs). However, the literature is conflicted regarding the effect of CD on perioperative and long-term outcomes after open TAAA repair. The goal of this study was to determine whether CD predicts negative outcomes after TAAA repair. METHODS: All open type I to type III TAAA repairs performed from 1987 to 2015 were evaluated using a single institutional database. End points included in-hospital death, spinal cord ischemia (SCI), major adverse events (MAEs), and long-term survival. Repairs performed for rupture or acute dissection were excluded. Univariate analysis was conducted using the Fisher's exact test for categorical variables and the Wilcoxon rank sum test for continuous variables. Logistic multivariable regression was used for the in-hospital end points, and survival analyses were performed with Cox proportional hazards modeling and Kaplan-Meier techniques. RESULTS: During the study period, 453 patients underwent an intact open type I to type III TAAA repair. Ninety (20%) were performed for patients with CD. Those with CD were more likely to be younger (59 years vs 72 years; P < .001), to have an extent II lesion (30% vs 16%; P < .001), and to have Marfan syndrome (18% vs 0.6%; P < .001) and less likely to have coronary artery disease (28% vs 25%; P = .01) or chronic obstructive pulmonary disease (12% vs 27%; P = .004) compared with patients with DA. Twelve percent of patients with CD died perioperatively compared with 6% of those with DA (P = .03). Eighteen percent of CD patients suffered from SCI compared with 12% of DA patients (P = .2). Fifty-nine CD patients suffered a MAE compared with 42% of those with DA (P = .006). Multivariable analysis revealed CD to be an independent predictor of perioperative death (adjusted odds ratio [AOR], 3.1; 95% confidence interval [CI], 1.2-8.0; P = .02) with adjustment for age and Crawford extent. CD was also found to be independently predictive of any MAE (AOR, 2.5; 95% CI, 1.4-4.6; P = .002). CD was not associated with increased risk of SCI (AOR, 1.4; 95% CI, 0.6-3.2; P = .4). There was a long-term survival advantage in the CD cohort in the unadjusted analysis (log-rank, P = .009) but not in the adjusted analysis (CD adjusted hazard ratio, 0.9; 95% CI, 0.6-1.4; P = .7). CONCLUSIONS: When analysis is limited to type I to type III TAAAs, open repair of patients with CD leads to increased perioperative mortality and morbidity compared with patients with DA. However, age-adjusted long-term survival is no different between the two cohorts.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Chronic Disease , Databases, Factual , Female , Humans , Male , Middle Aged , Postoperative Complications/mortality , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
11.
J Biomech ; 110: 109978, 2020 09 18.
Article in English | MEDLINE | ID: mdl-32827785

ABSTRACT

Aortic dissection is one of the most lethal cardiovascular diseases. A chronic Type A (Stanford) dissected aorta was retrieved for research from a 73-year-old male donor without diagnosed genetic disease. The aorta presented a dissection over the full length, and it reached a diameter of 7.7 cm in its ascending portion. The descending thoracic aorta underwent layer-specific quasi-static and dynamic mechanical characterizations after layer separation. Mechanical tests showed a physiological (healthy) behavior of the intima and some mechanical anomalies of the media and the adventitia. In particular, the static stiffness of both these layers at smaller strains was three times smaller than any one measured for twelve healthy aortas. When the viscoelastic properties were tested, adventitia presented a larger relative increase of the dynamic stiffness at 3 Hz with respect to most of the healthy aortas. The loss factor of the adventitia, which is associated with dissipation, was at the lower limit of those measured for healthy aortas. It seems reasonable to attribute these anomalies of the mechanical properties exhibited by the media and the adventitia to the severe remodeling secondary to the chronic nature of the dissection. However, it cannot be excluded that some of the mechanical anomalies were present before remodeling.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Adventitia , Aged , Aorta , Aorta, Thoracic , Biomechanical Phenomena , Humans , Male , Stress, Mechanical
12.
Cardiovasc Intervent Radiol ; 43(10): 1440-1448, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32556604

ABSTRACT

PURPOSE: To report early and mid-term results of post-aortic dissection thoracoabdominal aneurysms (pD-TAAA) treated by complex endografting in three tertiary referral hospitals. MATERIALS AND METHODS: A review of all patients with pD-TAAA unfit for open surgery treated with complex endovascular repair from 2012 to 2018 was performed. Simple thoracic endografts (TEVAR) were excluded. Staged procedures in case of extensive aortic coverage were always planned. RESULTS: In total, 21 patients (16 males, mean age 63 ± 10 years) with pD-TAAA underwent aortic repair by fenestrated or branched thoracoabdominal endografts for visceral vessels. Mean TAAA diameter was 61 ± 6.2 mm. Spinal cord drainage was performed in all patients. A staged approach was used in 12 (57%) cases. Technical success was achieved in 18 (86%) patients. No in-hospital deaths occurred. Two patients experienced transient post-procedural spinal cord ischemia. At 30 days, six type II endoleaks (29%), two type Ic endoleak (9.5%) and one type IIIc endoleak (5%) were reported. At a mean follow-up of 23 ± 13 months, no late aortic-related deaths occurred. Three patients underwent reintervention for type Ic and IIIc endoleaks. No visceral vessel occlusion was observed. Estimated freedom from reintervention at 12 and 24 months was 85.7 ± 0.7%. In 13 cases, TAAA diameter decreased at least 5 mm, while increased > 5 mm in only one case. Complete false lumen thrombosis was achieved in 18 patients (86%). CONCLUSION: Complex endografting for pD-TAAA showed favorable mid-term results. Staged and carefully planned endovascular procedures may represent a safe and effective therapeutic option in patients deemed at high risk of open repair.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis , Endovascular Procedures/methods , Aged , Aged, 80 and over , Aortic Dissection/complications , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/etiology , Aortography , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Female , Humans , Male , Middle Aged , Postoperative Complications/therapy , Prosthesis Design , Reoperation , Retrospective Studies , Risk Factors , Tomography, X-Ray Computed , Treatment Outcome
13.
J Cardiothorac Surg ; 15(1): 87, 2020 May 12.
Article in English | MEDLINE | ID: mdl-32398043

ABSTRACT

BACKGROUND: Pulmonary artery aneurysm (PAA), usually associated with congenital heart disease (CHD), is a very rare clinical condition. Pulmonary artery dissection (PAD) is considered the most life-threatening complication of PAA, and patients can progress from being asymptomatic to sudden death. We report the following case of PAA associated with complicated congenital heart disease and simultaneous chronic PAD. To our knowledge, few such complicated cases have ever been reported. CASE PRESENTATION: A 36-year-old male presented to our hospital with a 10-year history of heart fatigue after activities and aggravated for 2 years. Computed tomography angiography (CTA) and echocardiogram showed a giant main pulmonary artery aneurysm (14 cm) with complicated congenital heart disease (a small patent ductus arteriosus, ventricular septal defects, aortic coarctation). Chronic PAD, which was mistaken for a pulmonary valve before operation, was detected during surgery. CONCLUSIONS: PAA associated with complicated CHD and simultaneous PAD is very rare, and its clinical symptoms are varied. Radiologists and surgeons should pay attention to determining whether this patient simultaneously had PAD when PAA was detected on preoperative CTA imaging.


Subject(s)
Aortic Dissection/complications , Heart Defects, Congenital/complications , Pulmonary Artery/surgery , Adult , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Chronic Disease , Computed Tomography Angiography , Echocardiography , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Humans , Male , Pulmonary Artery/diagnostic imaging
14.
J Endovasc Ther ; 27(3): 421-427, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32193990

ABSTRACT

Purpose: To report the outcomes from the observational SURPASS registry, which was created to assess the performance of the Conformable TAG (CTAG) stent-graft with the Active Control System (ACS) in patients undergoing thoracic endovascular aortic repair (TEVAR) in a real-world setting. Materials and Methods: The SURPASS registry (ClinicalTrials.gov; identifier NCT03286400) was an observational, prospective, single-arm, post-market, international study that enrolled patients undergoing TEVAR using the CTAG with ACS for both acute and chronic thoracic aortic disease between October 2017 and July 2018. The CTAG with ACS features 2-stage deployment of the stent-graft and an optional angulation mechanism that modifies only the proximal end of the stent-graft. During the observation period, 127 patients (mean age 67.1±12.1 years, range 27-86; 92 men) were enrolled and treated for an array of aortic pathologies, including chronic and acute lesions and 4 ruptured descending thoracic aneurysms. The primary outcome of this study was technical success; secondary outcomes were clinical success and major adverse events at 30 days and 12 months. The numbers of 2-stage device deployments and applications of the angulation mechanism were recorded, along with the reasons for use. Results: Technical success of the TEVAR was 97.6% owing to unintentional partial coverage of supra-aortic branches in 3 cases (the vessels were patent on imaging). The stent-graft was repositioned at its intermediate diameter in 79 patients (62.2%), and the angulation feature was applied in 64 cases (50.4%), mainly to improve proximal wall apposition and orthogonality in the aorta. The desired effect was achieved in 60 cases (93.8%). There was no device compression, bird-beak configuration, fracture, or graft occlusion. The 30-day and 12-month clinical success rates were 97.6% and 92.9%, respectively. There were 3 aorta-related deaths at 30 days and a further 3 at 12 months. Fatalities were due to a retrograde type A dissection (0.8%), paraplegia, bowel ischemia, sepsis in the setting of a mycotic aneurysm, aneurysm rupture post aortoesophageal fistula, and multiorgan dysfunction syndrome. Three endoleaks (2 type Ia and 1 type III) required reintervention. Conclusion: In the SURPASS registry, the use of the CTAG device with ACS showed promising outcomes despite the challenging pathologies. The new delivery system enables a controlled staged delivery with in situ adjustments during positioning, facilitating the treatment of complex aortic disease.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Adult , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Aortic Diseases/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Product Surveillance, Postmarketing , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
15.
Eur J Cardiothorac Surg ; 58(1): 199-201, 2020 07 01.
Article in English | MEDLINE | ID: mdl-31958114

ABSTRACT

The Djumbodis™ dissection system was introduced as an alternative to aortic arch replacement in acute type A aortic dissection involving the arch. In our own experience, some patients with Djumbodis implantation developed distal aortic arch and descending aortic aneurysm during subsequent follow-up and required additional interventions. However, as there is a high incidence of fracture associated with the Djumbodis system, further endovascular interventions are not feasible. We report a case of successful open descending aortic replacement in a patient with a fractured Djumbodis stent system.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Dissection , Humans , Stents , Treatment Outcome
16.
J Invasive Cardiol ; 31(7): E233, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31257223

ABSTRACT

Coronary angiography in a 44-year-old woman shows chronic dissection of the left sinus of Valsalva, totally obscuring the LMCA, with good collaterals supplying the left coronary system from the right coronary artery.


Subject(s)
Aortic Aneurysm/complications , Aortic Dissection/complications , Coronary Occlusion/etiology , Coronary Vessels/diagnostic imaging , Sinus of Valsalva , Adult , Aortic Dissection/diagnosis , Aortic Aneurysm/diagnosis , Chronic Disease , Computed Tomography Angiography , Coronary Angiography , Coronary Occlusion/diagnosis , Female , Humans
17.
Vasc Endovascular Surg ; 53(3): 199-205, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30558509

ABSTRACT

OBJECTIVES:: Patients with chronic aortic dissection often require repeat interventions due to enlargement of the pressurized false lumen or disseminated intravascular coagulation even after additional thoracic endovascular aortic repair (TEVAR) to occlude the entry tear. Residual false lumen flow can persist even after performing the candy-plug technique or branched stent-graft placement in some cases. We have devised a new method for false lumen closure. METHODS:: From December 2010 to May 2017, 5 patients (mean age: 57 [13] years, range: 43-77 years) with chronic dissection at the aortic arch and descending aorta, who underwent initial TEVAR, required additional treatment. Using an open surgical approach, the endograft was fixed with an outer felt under cardiopulmonary bypass after the endograft with stent was expanded by fenestration. The false lumen was closed using this procedure, and the aortotomy was repaired by direct closure in 2 cases and by graft replacement in 3 cases. RESULTS:: No major operative complications occurred, such as respiratory failure or paraplegia. Postoperative enhanced computed tomography (CT) images showed that the false lumen flow disappeared in all cases. All patients were discharged under normal conditions. They were all followed up and their CT did not indicate any complications for a mean of 33.6 (20.3) months. CONCLUSIONS:: Our combined procedure was effective and provided a higher success rate compared with endovascular therapy alone. This staged treatment approach, using a combination of TEVAR and false lumen closure, is less invasive compared with open surgery alone and may represent a valid treatment option for chronic type B dissection.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Adult , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Dissection/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Chronic Disease , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Regional Blood Flow , Retrospective Studies , Risk Factors , Stents , Time Factors , Treatment Outcome
18.
J Vasc Surg ; 69(1): 249-252, 2019 01.
Article in English | MEDLINE | ID: mdl-30177409

ABSTRACT

Chronic type B aortic dissection with aneurysmal degeneration requiring intervention presents significant therapeutic challenges. Thoracic endovascular aortic repair with a fenestrated endograft is a feasible option, but false lumen branches without an adjacent re-entry or perforation in the septum can pose a significant challenge. We present two cases of fenestrated endovascular aneurysm repair for chronic type B aortic dissection in which a renal artery from the false lumen was cannulated by creating a "neofenestration" through the dissection flap using a radiofrequency PowerWire (Baylis Medical Inc, Montreal, Quebec, Canada) technique (Toronto PowerWire fenestration technique).


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Aged , Aortic Dissection/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Chronic Disease , Computed Tomography Angiography , Endovascular Procedures/instrumentation , Female , Humans , Male , Radiography, Interventional , Stents , Treatment Outcome , Vascular Access Devices
19.
Eur J Vasc Endovasc Surg ; 57(1): 102-109, 2019 01.
Article in English | MEDLINE | ID: mdl-30181064

ABSTRACT

OBJECTIVES: Patients surviving acute aortic dissection are at risk of developing a post-dissection thoraco-abdominal aortic aneurysm (PD-TAAA) during follow up, regardless of the type of treatment in the acute setting. Fenestrated and branched stent grafting (F/B-TEVAR) has been used with success to treat PD-TAAA, albeit reported only with short-term results. The aim of this study was to report mid-term results in a cohort of 71 patients. METHODS: This was a retrospective analysis of a prospectively maintained database including all patients with PD-TAAAs who underwent F/B-TEVAR within the period January 2010 - April 2017 at two vascular institutions experienced in endovascular techniques. RESULTS: A total of 71 consecutive patients (56 male, mean age 63.8 ± 10.6 years) were treated. Technical success was achieved in 68/71 (95.8%) patients. In hospital mortality was four (5.6%) patients. Peri-operative morbidity was 19.6%. Three (4.2%) patients developed severe spinal cord ischaemia, one of these patients 12 months post-operatively. Mean follow up was 25.3 months (1-77 months). Cumulative survival rates at 12, 24, and 36 months were 84.7 ± 4.5%, 80.7 ± 5.1%, and 70.0 ± 6.7%, respectively. Estimated freedom from re-intervention at 12, 24, and 36 months was 80.7 ± 5.3%, 63.0 ± 6.9%, and 52.6 ± 8.0%, respectively. The main reasons for re-intervention were endoleak from visceral/renal arteries and iliac endoleak requiring extension. Target vessel occlusion occurred in 8/261 (3.1%) vessels (renal artery n = 4; superior mesenteric artery n = 2; coeliac artery n = 2). Mean aneurysm sac regression during follow up was 9.2 ± 8.8 mm, with a false lumen thrombosis rate of 85.4% for patients with a follow up longer than 12 months. No ruptures occurred during follow up. CONCLUSION: F/B-TEVAR for post-dissection TAAA is feasible and associated with low peri-operative mortality and peri-operative morbidity. Mid-term results demonstrate a high rate of aneurysm sac regression. Rigorous follow up is required because of the significant re-intervention rate. Longer bridging covered stents for target vessels are advised.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/complications , Blood Vessel Prosthesis Implantation , Stents , Aged , Aortic Aneurysm, Thoracic/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/surgery , Female , Follow-Up Studies , Hospital Mortality , Humans , Male , Middle Aged , Postoperative Complications/surgery , Reoperation , Retrospective Studies , Risk Factors , Survival Analysis , Vascular Patency
20.
Article in Russian | MEDLINE | ID: mdl-30132450

ABSTRACT

AIM: To evaluate the prognostic significance of oxygen supply to the brain in the risk of neurological complications in the early post operative period of surgical treatment of the ascending aorta and aortic arch. MATERIAL AND METHODS: The level of oxygenation (rSO2) in the right and left hemispheres was measured in 68 patients with ascending aorta and aortic arch chronic dissection. Before and in the nearest period after surgery, the patients underwent a clinical/instrumental neurological study. RESULTS: The incidence of ischemic stroke in the early post operative period was 5.9%, cognitive impairment was recorded in 22% of patients. Among the parameters of oxygen supply to the brain, the dynamics of rSO2 during circulatory arrest had a significant impact on the post operative neurological status. The risk of cognitive impairment, besides the association with the oxygen status of the brain, increased with the age of patients and comorbid pathology. CONCLUSION: The decrease in rSO2 by ≥30% during surgical treatment of ascending aorta and aortic arch dissection increases the risk of ischemic stroke and cognitive impairment in the early post operative period.


Subject(s)
Aortic Dissection , Nervous System Diseases , Aorta , Aorta, Thoracic , Humans , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL