Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.329
Filter
1.
BMC Oral Health ; 24(1): 737, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38937760

ABSTRACT

BACKGROUND: The desirable properties of silver diamine fluoride (SDF) make it an effective agent for managing dental caries and tooth hypersensitivity. There are several clinical instances that SDF application might precede the placement of direct tooth-colored restorations. On the other hand, SDF stains demineralized/carious dental tissues black, which might affect the esthetic outcomes of such restorations. Color is a key parameter of esthetics in dentistry. Therefore, this study aims to systematically review dental literature on color/color change of tooth-colored restorations placed following the application of SDF on dentine. METHODS: Comprehensive search of PubMed, Embase, Scopus and ISI Web of Science databases (until August 2023) as well as reference lists of retrieved studies was performed. In vitro studies reported color or color change of tooth-colored restorative materials applied on SDF-treated dentine were included. Methodological quality assessment was performed using RoBDEMAT tool. Pooled weighted mean difference (WMD) and 95% confidence interval (95% CI) was calculated. RESULTS: Eleven studies/reports with a total of 394 tooth-colored restorations placed following a) no SDF (control) or b) SDF with/without potassium iodide (KI)/glutathione dentine pre-treatments were included. Color change was quantified using ∆E formulas in most reports. The pooled findings for the comparison of resin-based composite (RBC) restorations with and without prior 38% SDF + KI application revealed no statistically significant differences in ∆E values at short- and long-term evaluations (~ 14 days: WMD: -0.56, 95% CI: -2.09 to 0.96; I2: 89.6%, and ~ 60 days: WMD: 0.11; 95% CI: -1.51 to 1.72; I2: 76.9%). No studies provided sufficient information for all the items in the risk of bias tool (moderate to low quality). CONCLUSIONS: The limited evidence suggested comparable color changes of RBC restorations with and without 38% SDF + KI pre-treatment up to 60 days. The included studies lacked uniformity in methodology and reported outcomes. Further studies are imperative to draw more definite conclusions. PROTOCOL REGISTRATION: The protocol of this systematic review was registered in PROSPERO database under number CRD42023485083.


Subject(s)
Color , Dental Restoration, Permanent , Dentin , Fluorides, Topical , Quaternary Ammonium Compounds , Silver Compounds , Humans , Quaternary Ammonium Compounds/pharmacology , Quaternary Ammonium Compounds/therapeutic use , Fluorides, Topical/therapeutic use , Dentin/drug effects , Dental Restoration, Permanent/methods
2.
Dent Mater ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38926014

ABSTRACT

PURPOSE: This study aimed to reproduce and translate clinical presentations in an in vitro set-up and evaluate laboratory outcomes of mechanical properties (flexural strength, fatigue resistance, wear resistance) and link them to the clinical outcomes of the employed materials in the Radboud Tooth Wear Project (RTWP). MATERIALS AND METHODS: Four dental resin composites were selected. 30 discs (Ø12.0 mm, 1.2 mm thick) were fabricated for each of Clearfil TM AP-X (AP), Filtek TM Supreme XTE (FS), Estenia TM C&B (ES), and Lava Ultimate (LU). Cyclic loading (200 N, 2 Hz frequency) was applied concentrically to 15 specimens per group with a spherical steatite indenter (r = 3.18 mm) in water in a contact-load-slide-liftoff motion (105 cycles). The wear scar was analysed using profilometry and the volume loss was digitally computed. Finally, all specimens were loaded (fatigued specimens with their worn surface loaded in tension) until fracture in a biaxial flexure apparatus. The differences in volume loss and flexural strength were determined using regression analysis. RESULTS: Compared to AP and FS, ES and LU showed a significantly lower volume loss (p < 0.05). Non-fatigued ES specimens had a similar flexural strength compared to nonfatigued AP, while non-fatigued FS and LU specimens had a lower flexural strength (p < 0.001; 95 %CI: -80.0 - 51.8). The fatigue test resulted in a significant decrease of the flexural strength of ES specimens, only (p < 0.001; 95 %CI: -96.1 - -54.6). CLINICAL RELEVANCE: These outcomes concur with the outcomes of clinical studies on the longevity of these composites in patients with tooth wear. Therefore, the employed laboratory test seems to have the potential to test materials in a clinically relevant way.

4.
BMC Oral Health ; 24(1): 651, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831398

ABSTRACT

BACKGROUND: Carious/Non-carious cervical lesions with gingival recessions may require both dental and periodontal reconstructive therapy, where flaps/grafts may be placed in contact with a dental filling material. Human Gingival Fibroblasts (HGF-1) response during the early phase of healing could vary according to the procedures employed to cure the dental composite. Moreover, oxygen diffusion into dental composite inhibits the polymerization reaction, creating an oxygen-inhibited layer (OIL) that presents residual unreacted monomers. The aim of this study was to assess the effect of different polishing techniques and OIL on HGF-1. METHODS: Composite discs polished with different techniques (diamond rubber, abrasive discs and tungsten carbide burr) were used. An additional not polished smooth group obtained with and without OIL was used as control. Samples were physically characterized through the analysis of their hydrophilicity and surface topography through contact angle measurement and SEM, respectively; afterwards the biologic response of HGF-1 when cultured on the different substrates was analyzed in terms of cytotoxicity and gene expression. RESULTS: The finishing systems caused alterations to the wettability, even if without a proportional relation towards the results of the proliferation essay, from which emerges a greater proliferation on surfaces polished with one-step diamond rubber and with abrasive discs as well as a direct effect of the glycerin layer, confirming that surface roughness can heavily influence the biological response of HGF-1. CONCLUSIONS: Surfaces wettability as well as cellular behavior seem to be affected by the selection of the finishing system used to lastly shape the restoration. Especially, the presence of OIL act as a negative factor in the regards of human gingival fibroblasts. The present study may provide the first clinical instruction regarding the best polishing system of composite material when the restoration is placed directly in contact with soft tissue cells. Understanding HGF-1 behavior can help identifying the polishing treatment for direct restoration of carious/non-carious cervical lesions associated with gingival recessions.


Subject(s)
Composite Resins , Dental Polishing , Fibroblasts , Gingiva , Surface Properties , Humans , Gingiva/cytology , Dental Polishing/methods , Microscopy, Electron, Scanning , Cell Proliferation , Wettability , Dental Restoration, Permanent/methods , Tungsten Compounds/pharmacology , Cells, Cultured
5.
Gen Dent ; 72(4): 54-57, 2024.
Article in English | MEDLINE | ID: mdl-38905606

ABSTRACT

The purpose of this study was to determine the most effective method for bonding composite resin to artificially aged amalgam. A spherical amalgam alloy was triturated and condensed by hand into cylindrical plastic molds (6 mm in diameter and 4 mm in height) to create 90 specimens, which were then aged for 2 weeks in closed plastic containers at 23°C. The amalgam surfaces underwent 1 of 3 surface treatments (n = 30 per treatment): (1) air particle abrasion (APA) with 50-µm aluminum oxide particles applied with a force of 45 psi from a 10-mm distance, followed by rinsing with deionized water for 60 seconds; (2) APA following the same protocol with subsequent application of a metal primer (Alloy Primer); or (3) coating with 30-µm silica (CoJet) at a force of 45 psi from a 10-mm distance until the surface turned black. Specimens were then treated with 1 of 3 adhesives (n = 10 per adhesive per surface treatment): (1) 2-step total-etch adhesive (OptiBond Solo Plus), (2) 1-step self-etching adhesive (Scotchbond Universal), or (3) dual-cured resin cement (Panavia F 2.0). Each adhesive was applied to the treated amalgam surfaces following its manufacturer's instructions. The specimens were placed in a bonding clamp, and nanocomposite resin columns, 2.38 mm in diameter and 2.00 mm in height, were photocured (40 seconds, 500 mW/cm2) against the treated amalgam surfaces. The specimens were stored for 24 hours in 37°C deionized water and underwent shear bond strength testing at a crosshead speed of 0.5 mm/min. Data were analyzed using 2-way analysis of variance and post hoc analysis with the Tukey test at 95% confidence. The mean (SD) shear bond strength values ranged from 12.3 (1.2) MPa for aluminum oxide-treated surfaces bonded with OptiBond Solo Plus to 25.9 (4.6) MPa for silicoated surfaces bonded with Panavia F 2.0. All bonding agents produced the highest shear bond strength when the amalgam surface was silicoated. These results indicate that composite can be effectively bonded to amalgam via silicoating.


Subject(s)
Composite Resins , Dental Amalgam , Dental Bonding , Dental Amalgam/therapeutic use , Composite Resins/therapeutic use , Dental Bonding/methods , Surface Properties , Dental Restoration Repair/methods , Humans , Resin Cements/therapeutic use , Resin Cements/chemistry , Materials Testing , Shear Strength , Methacrylates , Thiones
6.
Gen Dent ; 72(4): 23-29, 2024.
Article in English | MEDLINE | ID: mdl-38905601

ABSTRACT

This study evaluated the fracture resistance of endodontically treated maxillary premolars restored with a new self-adhesive composite hybrid material (Surefil one [SO]) using different protocols. A total of 72 maxillary premolars were divided into 6 groups (n = 12). The control group included intact teeth, and the other 5 groups included teeth in which disto-occlusal cavities were prepared and endodontic treatment was performed. The prepared cavities were assigned to groups that were based on the restorative procedures: bulk-fill group, universal adhesive plus conventional bulk-fill composite resin plus a layer of conventional composite resin; SO-SC group, self-cured SO; SO-LC group, light-cured SO; SO-UA group, universal adhesive plus SO; or SO-core group, a 4.0-mm layer of SO covered by a layer of conventional composite resin. Specimens in each group underwent thermocycling and load cycling to test the fracture strength and fracture mode. The results were analyzed using analysis of variance and the Tukey test (α = 0.05). The SO-core group showed the highest mean (SD) fracture resistance, 959.9 (171.8) N, among the restored groups. The SO-core group did not differ significantly from the control group (P > 0.05) but did show significantly higher strength than all other test groups (P < 0.05) except SO-SC (P = 0.364). No significant differences were found between the bulk-fill, SO-SC, SO-LC, and SO-UA groups (P > 0.05). The SO-core group showed the highest number of unrestorable fractures, while the main fracture mode for the other groups was restorable fracture. Although the use of SO as a core material restored the fracture strength of endodontically treated premolars to the level of intact teeth, it also resulted in a higher incidence of unrestorable fractures. The SO-SC group demonstrated a high fracture resistance comparable to that of the SO-core group and had a greater tendency to experience restorable fractures.


Subject(s)
Bicuspid , Composite Resins , Dental Stress Analysis , Tooth Fractures , Tooth, Nonvital , Humans , Composite Resins/therapeutic use , Dental Restoration, Permanent/methods , Dental Restoration Failure , Materials Testing , Maxilla
7.
Odontology ; 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38837034

ABSTRACT

This 72-month study compared the clinical effectiveness of a resin-based composite (RBC) (Spectrum TPH3, Dentsply Sirona) with a resin-modified glass ionomer cement (RMGIC) (Riva Light Cure, SDI) in restoring cervical caries lesions (CCLs). Thirty-three patients, each with at least two CCLs, were enrolled. After caries removal, the dimensions of the cavities were recorded. In a split-mouth study design, a total of 110 restorations were randomly placed. Fifty-five restorations were placed with RBC using an etch-and-rinse adhesive system (Prime&Bond NT, Dentsply Sirona), while the remaining 55 were restored with RMGIC. The restorations were assessed at baseline, 6, 12, 18, 24, 36, 60, and 72 months according to modified USPHS criteria. Statistical analysis included Pearson Chi-square, Friedman tests, Kaplan Meier, and Logistic Regression analysis (p < 0.05). After 72 months, 47 restorations in 19 patients were evaluated (55% follow-up rate). Seventy-five percent of the RBC (n = 26) and 74% (n = 21) of the RMGIC restorations were fully retained. There were no significant differences between materials regarding retention and marginal adaptation (p > 0.05). Cavity dimensions, caries activity, and retention exhibited no correlation (p > 0.05). The increase in marginal staining in both groups over time was significant (p < 0.001). RMGIC restorations exhibited higher discoloration than RBC restorations (p = 0.014). At 72 months, three secondary caries lesions were detected in both restoration groups: two RMGIC and one RBC. There were no reports of sensitivity. After 72 months, both RBC and RMGIC restorations were clinically successful, with similar retention and marginal adaptation scores. However, it is noteworthy that RMGIC restorations tend to discoloration over time compared to RBC. The trial is registered in the database of "Clinical Trials". The registration number is NCT0372-2758, October 29, 2018.

8.
Int J Periodontics Restorative Dent ; 0(0): 1-17, 2024 05 31.
Article in English | MEDLINE | ID: mdl-38820272

ABSTRACT

The objective of this work is to report a restorative approach with composite resin applied in reverse in the aesthetic resolution of darkened anterior teeth. A 27-year-old female patient presented with the main complaint of dissatisfaction with the aesthetics of her smile due to dental darkening, a result of childhood trauma, without painful symptoms, pathological clinical signs or change in care. In the intraoral examination, a darkening of teeth 11 and 21 was observed, which radiographically showed thickening of the periodontal ligament, with disharmonious configuration of the marginal gingiva. From the clinical and radiographic characteristics, we opted for periodontal intervention for recovery and gingival levelling, followed by endodontic intervention and aesthetic restorative restoration. The restorative step was carried out sequentially by internal tooth bleaching, removal of dentin still pigmented after bleaching and enamel preservation. Soon after, it was restored in an alternative way and layered using a technique called reverse, using strips of polyethylene fiber over the dentin resin. The technique preserved the remaining enamel with the maintenance of the original remaining guides, proving to be a viable conservative alternative since of the diagnosis to the restorative conclusion in view of the longitudinal confirmation of the restorative efficacy after 1 year.

9.
J Mech Behav Biomed Mater ; 155: 106568, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38714003

ABSTRACT

PURPOSE: The strength of temporary restorations plays a vital role in full-mouth reconstruction, and it can be impacted by the aging process. The aim of this in vitro study was to evaluate the biaxial flexural strength and fractographic features of different resin-based materials submitted to thermal aging. MATERIAL AND METHODS: One hundred and ninety-two resin disc-shaped specimens (6.5 mm in diameter and 0.5 mm in thickness) were fabricated and divided into six experimental groups according to the resin-based materials (Filtek Bulk-Fill flowable resin; J-Temp temporary resin; and Fuji Lining glass ionomer cement) and aging process (before and after thermal cycling). Biaxial flexural strength test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min before and after thermal cycling (5 °C and 55 °C, 5760 cycles, 30 s). The mechanical properties were assessed using Weibull parameters (characteristic strength and Weibull modulus) (n = 30). Fractured specimens were examined under a polarized light stereomicroscope to identify crack origin and propagation direction. The surface microstructure of the resin-based materials was assessed by scanning electron microscopy (n = 2). The Weibull modulus (m), characteristic strength, and reliability properties were calculated, and a contour plot was used to detect differences among groups (95% confidence interval). RESULTS: The Weibull modulus (m), characteristic strength, and reliability of the resin-based compounds were influenced by material type and thermal aging (p < 0.05). Weibull modulus (m) revealed no differences when comparing the materials and aging process (p > 0.05), except for the preceding aging period where Filtek Bulk-Fill exhibited higher values compared to J-Temp (p < 0.05). Filtek Bulk-Fill demonstrated superior characteristic strength and reliability compared to J-Temp and Fuji Lining before and after thermal cycling (p < 0.05). Fractography of the resin-based materials showed fractures originating from surface defects exposed to tensile side and their propagation toward the compressive side. Generally, no differences in surface microstructure were observed on micrographs before and after thermal aging for Filtek Bulk-Fill and Fuji Lining. However, the aging process developed flaws in J-Temp. CONCLUSION: Resin-based material composition resulted in different flexural strength performance, impacting the Weibull modulus (m), characteristic strength, and reliability of the resin-based restorations.


Subject(s)
Composite Resins , Flexural Strength , Materials Testing , Composite Resins/chemistry , Resins, Synthetic/chemistry , Temperature , Time Factors , Water/chemistry , Stress, Mechanical
10.
J Contemp Dent Pract ; 25(3): 221-225, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690693

ABSTRACT

AIM: This study aimed to assess the color stability of bioactive restorative materials vs nanohybrid resin composites after 3 months of immersion in three frequently consumed beverages. MATERIALS AND METHODS: Thirty disk-shaped specimens of Giomer dental restorative material (Shofu, Japan) and nanohybrid resin composite (Tokuyama, Japan) were performed using a Teflon mold. Super-Snap system (Shofu, Japan) was utilized to finish and polish the specimens to be preserved for 24 hours in distilled water at 37°C. The samples had been divided into three subgroups (Coffee, tea, Pepsi) (n = 5). The initially displayed color measurements of the samples were performed using a spectrophotometer (VITA Easyshade® V). After 7 days, 30 days, and 90 days, color measurements were repeated, and the E of each sample was estimated. E of each sample was calculated. RESULTS: The Giomer group showed statistically significant higher E values than the nanohybrid resin composite where the p-value was ≤0.0001. Tea subgroup showed the highest statistically significant E values in both groups where the p-value was ≤ 0.0001. The highest statistically significant color change was recorded at 3 months. CONCLUSION: The color of bioactive restorative material is less stable if compared with nanohybrid resin composite. CLINICAL SIGNIFICANCE: As tea and coffee are popular beverages, particularly in Middle Eastern nations, dentists must advise patients about the color change of resin restorations. Patients are advised to brush their teeth immediately after consuming these beverages. How to cite this article: Saber EH, Abielhassan MH, Abed YA, et al. Color Stability of Bioactive Restorative Material vs Nanohybrid Resin Composite: An In Vitro Study. J Contemp Dent Pract 2024;25(3):221-225.


Subject(s)
Color , Composite Resins , Materials Testing , Tea , Composite Resins/chemistry , In Vitro Techniques , Coffee , Spectrophotometry , Dental Restoration, Permanent , Nanocomposites/chemistry , Dental Materials/chemistry , Humans , Beverages
11.
Heliyon ; 10(10): e30794, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38770309

ABSTRACT

Background: By increasing fluidity and conversion, pre-heated composites enhance adaptability and strength, while soft-start polymerization decreases internal stresses. Aim: Over a period of a year, this split-mouth design, randomized controlled clinical trial (RCT) compared pre-heated composites with soft-start polymerization to conventional composites in class-I lesions, with the goal of improving restoration outcomes. Methods: and Findings: Immediately following ethical approval and registration with CTRI, 37 patients with in-formed permission who met specified inclusion and exclusion criteria for class-I lesions were chosen for enrollment. Using a 1:1 ratio, teeth were randomly assigned to Group-A (pre-heated composite with soft-start polymerization) or Group-B (traditional composite restoration). At three-time intervals, the evaluation was blinded and calibrated using Modified United States Public Health Service (USPHS) criteria: baseline, six-month, and one-year marks. Statistical analysis was performed using SPSS 21.0 and the Mann-Whitney U test for inter-group comparisons and the Friedman test for intra-group comparisons. Interpretation: Pre-heated composites with soft-start polymerization performed better in terms of marginal adaptation with a statistically significant difference (p = 0.019) and in terms of color match they performed better clinically (p = 0.062) at 12 months. Other variables like marginal discolouration, sec-ondary caries, anatomic form, post-operative sensitivity, surface texture and retention showed no statistically significant difference (p < 0.05). Pre-heated composites with soft-start mode performed marginally better than nanofilled composites. However, both techniques can be used to successfully restore simple class-I carious lesions.

12.
Support Care Cancer ; 32(5): 327, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702458

ABSTRACT

PURPOSE: This study is to conduct a comprehensive scoping review to map scientific evidence and clarify concepts regarding the commonly recommended preventive and restorative dental treatments for patients diagnosed with head and neck cancer (HNC) and subjected to radiotherapy. MATERIAL AND METHODS: This systematic scoping review was performed under the PRISMA-ScR guidelines. The study's experimental design was registered in the Open Science Framework. In vitro studies that evaluated preventive and restorative dental treatment over 50 Gy radiation doses were included. The search was conducted in November 2023 in five electronic databases (PubMed, Scopus, Web of Science, Cochrane Library, and Embase) without language or date restriction. A search strategy was applied based on keywords, MeSh terms, or synonyms. A descriptive analysis was conducted. RESULTS: A total of 49 studies, out of 3679 original articles identified, were included and reviewed. Of the included studies, three evaluated saliva stimulants and 35 evaluated fluoride-based preventive materials: gel (n = 18) toothpaste (n = 11) mouth rinse (n = 8) and varnish (n = 5) while 14 evaluated restorative materials: resin composite (n = 12) glass ionomer cement (n = 6) and amalgam (n = 1) Of those studies, 36 were clinical trials and 13 were in vitro studies. CONCLUSION: Fluoride gel was the most frequently recommended preventive material for preventing radiation caries with supportive clinical evidence. Resin composite and glass ionomer were the most frequently used restorative materials, respectively. However, there is not yet clinical evidence to support the use of resin composite in irradiated teeth.


Subject(s)
Dental Caries , Head and Neck Neoplasms , Humans , Dental Caries/prevention & control , Head and Neck Neoplasms/radiotherapy , Dental Restoration, Permanent/methods
13.
J Pak Med Assoc ; 74(5): 976-979, 2024 May.
Article in English | MEDLINE | ID: mdl-38783450

ABSTRACT

Bisphenol A (BPA) is commonly used in resin-based dental materials and is categorised as an endocrine-disrupting compound. This study aimed to evaluate the knowledge, attitudes, and practice toward the use of BPA among faculty members and postgraduate students. In this descriptive study, a validated self-administered questionnaire was used, and 204 dentists were included, with a response rate of 56.2%. The findings revealed that faculty members had significantly better knowledge (p=0.024) and practice (p=0.036) and more positive attitudes (p=0.024) toward BPA exposure. Regression analysis showed a significantly positive effect of attending a workshop/lecture or reading an article about BPA on the participants' total mean knowledge (p<0.001) and practice scores (p<0.001). Furthermore, faculty members showed a significantly more positive attitude (p<0.001) toward BPA exposure. These results emphasise the importance of increased awareness and education concerning BPA exposure to ensure optimal dental care.


Subject(s)
Benzhydryl Compounds , Health Knowledge, Attitudes, Practice , Phenols , Humans , Female , Male , Adult , Attitude of Health Personnel , Surveys and Questionnaires , Faculty, Dental , Endocrine Disruptors , Dentists , Middle Aged , Occupational Exposure/prevention & control , Dental Care
14.
Clin Oral Investig ; 28(5): 253, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630376

ABSTRACT

OBJECTIVES: To evaluate the longevity of resin composite restorations placed in posterior teeth by dental students, using data from electronic records from 2008 to 2019. MATERIALS AND METHODS: Demographic (gender and age) and clinical variables (dental group, position in dental arch, and the number of restored surfaces) were evaluated. The 5-year follow-up was assessed according to the day the restoration was placed. Kaplan-Meier curves were generated to calculate the annual failure rate. Data were analyzed by Chi-Square, Kruskal-Wallis, and Mann-Whitney tests (α = 0.05). RESULTS: In total, 3.883 records relative to return periodicity were analyzed. The final sample consisted of 900 restorations from 479 patients. The majority were females, aged between 31 and 60. In total, 256 failures were reported (success rate = 78%), showing an annual failure rate of 2.05%. The main reasons for failures were restoration replacement (55.5%), endodontics (21.9%), prosthetics (14.5%) and extraction (8.2%). There was a higher risk of failure in restorations involving three or more surfaces (p = 0.000) and in patients over 60 years (p < 0.001). In females (p = 0.030), molars (p = 0.044), and maxillary teeth (p = 0.038) failed in a shorter time. CONCLUSIONS: Resin composite restorations placed in permanent posterior teeth by dental students had high survival rates. The main reason for failure was the replacement of restorations. The age group and the number of restored surfaces significantly affected the success of the restorations. CLINICAL RELEVANCE: The electronic health records over 12 years showed that 78% of the resin restorations in posterior teeth placed by dental students were successful for a minimum of five years.


Subject(s)
Molar , Students, Dental , Female , Humans , Adult , Middle Aged , Male , Retrospective Studies , Composite Resins , Dental Care
15.
J Dent Educ ; 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38634400

ABSTRACT

INTRODUCTION: The acquisition of skills and manual dexterity in aesthetic dentistry in undergraduate teaching requires preclinical practices with simulation that should approximate real clinical situations. OBJECTIVE: We will present a digital procedure for the creation of three-dimensional (3D) resin models adapted to the practices of the Aesthetic Dentistry course. MATERIAL AND METHOD: Stereolithography or Standard Tesellation Language (STL) files of a real patient were previously obtained with a 3-shape intraoral scanner. Using the Exocad computer programme for dental prosthesis design, various modifications were made, such as incisor rotation, surface alterations imitating dysplasias or erosions, the creation of diastemas, or even changes in tooth size. The virtual model was printed in resin for use by students. Once the practices were finished, the students and the teachers evaluated the use of the 3D printed models. RESULTS: The result is the typodont model, in which seven laboratory sessions took place: 1-Restoration of conoid tooth morphology, 2-Cervical abrasion/ erosion restoration, 3-Direct Composite Veneer, 4-Aesthetic correction in a tooth with rotation, 5-Diastem closure, 6-Occlusal abrasions/ erosion, and 7-Maryland bridge. 90.48% of the students evaluated the designed 3D model as the best method for laboratory practice compared to other methods, obtaining a general assessment of 8.3 out of 10. CONCLUSION: The method used has provided a reproducible standard analog model for direct aesthetic dental restoration practice, with a good assessment by students and teachers.

16.
Acta Stomatol Croat ; 58(1): 30-38, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38562217

ABSTRACT

Objective: The aim of this study was to compare the light transmission of monowave and polywave-curing devices by a bulk-fill composite containing only camphorquinone as a photoinitiator. Materials and methods: Three light-curing devices were used to cure bulk-fill composite QuiXfil: one monowave (Translux® Wave) and two polywave (VALO Cordless and Bluephase® PowerCure. The NIST-calibrated spectrometer (MARC Resin Calibrator, BlueLight Analytics Inc.) was used to measure the incident and transmitted light through a 2-mm composite specimen over 20 s. Light transmittance was calculated from the ratio of the amount of transmitted and incident light. For data analysis (ANOVA, α = 0.05), total irradiation of the entire spectrum, irradiation with wavelengths of 360-420 nm for the violet spectrum, and 420-540 nm for the blue spectrum were selected. Results: Monowave curing unit Translux® Wave had the lowest light transmission (13.78 ± 0.5%), similar to the violet light transmission of polywave devices (12.02 ± 0.94% and 13.81 ± 1.72% for Valo Cordless and Bluephase PowerCure, respectively). Blue light transmittance (32.15-23.70%) was more than twofold higher than for the wavelengths in the violet region of the spectrum (13.81-12.02%) for the two polywave devices. VALO Cordless showed the highest total and blue light transmission (p<0.001). There was no significant difference in the transmission of the violet part of the spectrum between VALO Cordless and Bluephase® PowerCure (p = 0.465). Conclusion: Within the limitations of this study, we could conclude that polywave curing devices can be used for the polymerization of the bulk-fill composite with camphorquinone as the sole photoinitiator.

17.
Acta Stomatol Croat ; 58(1): 18-29, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38562221

ABSTRACT

Objectives: To compare three different orthodontic adhesives (Transbond XT Light Cure Adhesive, Heliosit Orthodontic, Fuji Ortho LC) bonded to two types of orthodontic brackets: ceramic brackets (Fascination Roth 0.22) and metallic brackets (Topic Roth 0.22, Dentaurum). Materials and methods: The study was performed on 18 human teeth (6 for each adhesive). The prepared teeth were divided into three groups according to the examination time. Subsequently, they were observed after 1, 2 and 3 weeks following bonding. After the experimental procedure, the teeth samples were cut in half along the longitudinal axis in the vestibulo-oral direction, fixed with conductive carbon cement, placed in a high-vacuum evaporator and then coated with carbon. One half of each sample was observed under a Field-emission gun scanning electron microscope (FEG-SEM Hitachi SU 8030, Japan), while on the second half of the samples qualitative (X-ray line-scans) and semi-quantitative point X-ray energy dispersive analyses (EDX) were performed with Thermo Noran (USA) NSS System 7, equipped with Ultra Dry detector (30 mm2 window). Results: Transbond XT had an ideal bond with the enamel and the bracket base, with rare presence of microgaps and cracks in the enamel. Heliosit Orthodontic demonstrated a better bond relationship with the bracket base than the enamel, whereas in the latter the presence of microgaps in the bond was observed. The microphotographs of Fuji Ortho LC demonstrated many cracks inside the adhesive, and some of them continued to move forward into the enamel surface. Therefore, an impression of a very solid bond relationship with the enamel exists, with cracks being present in the enamel surface and never at the enamel-adhesive interface. Microgaps also appeared at the bracket-adhesive interface. Conclusion: Transbond XT is a highly filled composite resin and is an ideal orthodontic adhesive in each aspect examined, with an ideal enamel-adhesive and bracket-adhesive interface. Heliosit Orthodontic provides better bracket-adhesive interface compared to the enamel. Fuji Ortho LC as a solid resin-modified GIC provides a better enamel-adhesive interface, compared to the bracket base.

18.
J Clin Med ; 13(5)2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38592699

ABSTRACT

Background: Performing an appropriate Class II direct restoration is a great challenge. The correct selection of the matrix system and the elements used for its stabilization will have a great impact on the result. The aim of this study is to show a new digital method for a predictable selection of the wedge and compare it with the conventional method. Methods: Sixty patients were randomly divided into two groups. In Group 0, the wedge was selected intraoperatively by visual examination, while in Group 1 the wedge was selected preoperatively through the measurement of the cervical embrasure on the bite-wing radiography. The number of wedges used, modifications to them, and tissue damage were registered, along with the quality of the proximal contact and the marginal adaptation. Results: Student's t-test revealed a statistical difference between the number of wedges used, which was higher in Group 0 (p < 0.05). Pearson Chi-square test showed that tissue damage was statistically higher in Group 0 (p < 0.05), while there was no statistically significant difference between groups in wedge modifications (p > 0.05). Group 1 revealed a higher frequency of satisfactory proximal contact and marginal adaptation (p < 0.05). Conclusions: This new technique reduces wedges waste and tissue damage and provides an adequate interproximal anatomy.

19.
J Pharm Bioallied Sci ; 16(Suppl 1): S690-S694, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38595355

ABSTRACT

Aim: This study intends to evaluate the frequency and causes of replacement for failed amalgam and composite dental restorations. Methodology: A cross-sectional study comprising female patients with failed permanent composite and amalgam restorations aged 15-60 years old was carried out at the dental clinics of Qassim University. Using a self-structured proforma, demographic data and causes for restoration failure were recorded. The effectiveness of the restorations was assessed by using the Ryge criteria after performing clinical and radiographic examinations. The Statistical Package for Social Science was used for the statistical analysis. Results: It is found that 84.6% of the 299 unsuccessful restorations examined were composite, and 15.4% were amalgam. The main reason for dental failure for both amalgam (95.6%) and composite (93.28%) restorations was secondary caries. Failure of amalgam restoration was largely caused by poor marginal adaptation. With varied incidences between amalgam and composite restorations, typical complaints included discomfort, sensitivity, pain, and food impaction with soreness. The main justification for replacement in amalgam restorations was sensitivity. Repair and replacement rates were similar for amalgam, composite, and mandibular/maxillary restorations. Moreover, 21.1% of individuals overall reported no symptoms, with 8.7% in the amalgam group and 23.3% in the composite group with significant differences (χ2 = 34.28, P = 0.001). Conclusion: According to the current study, secondary caries was found to be the main reason for both amalgam and composite restoration failure. The main problems reported were sensitivity, discomfort, and pain with amalgam showing more sensitivity-related failures.

20.
Dent Res J (Isfahan) ; 21: 18, 2024.
Article in English | MEDLINE | ID: mdl-38476712

ABSTRACT

Background: This study aimed to assess the effect of polishing versus glazing of computer-aided design-computer-aided manufacturing (CAD-CAM) ceramics on depth of wear and surface roughness of opposing composite resin. Materials and Methods: This in vitro study was conducted on 40 Z250 composite and 40 CAD-CAM ceramic specimens including Celtra Duo, Vita Mark II, e.max CAD, and Vita Suprinity ceramics. All ceramic specimens were roughened by a fine-grit bur after primary glazing to simulate an adjusted surface in the clinical setting. They were then randomly assigned to two subgroups and underwent reglazing or polishing. All composite and ceramic specimens underwent profilometry after surface treatment and prior to the wear test, and the results were recorded quantitatively. Composite specimens were then subjected to 120,000 wear cycles against ceramic specimens in a chewing simulator, and the depth of wear was measured by a scanner. Data were statistically analyzed by repeated measures two-way analysis of variance (ANOVA) and one-way ANOVA (α = 0.05). Results: Comparison of the surface roughness of composite specimens before and after the wear test revealed significant differences in both glazed Suprinity (P = 0.048) and Vita Mark II (P = 0.026) ceramics groups. The change in surface roughness after the wear test (compared with baseline) was significant in glazed (P = 0.000) and polished (P = 0.013) Vita Mark II and polished Suprinity (P = 0.037) ceramics, but this change was not significant in other ceramics (P > 0.05). The depth of wear after the wear test was not significantly different among the ceramic and composite subgroups (P > 0.05). Conclusion: Assessment of depth of wear and surface roughness of composite specimens showed that the polishing kits of CAD-CAM ceramics can serve as a suitable alternative to reglazing.

SELECTION OF CITATIONS
SEARCH DETAIL
...