Results 1 - 20 de 219
Filter
1.
Nano Lett ; 24(39): 12299-12306, 2024 Oct 02.
Article in English | MEDLINE | ID: mdl-39288099

ABSTRACT

An enduring question in science has been why sliding plays a major role in the triboelectric generation of static electricity-the "tribo" in triboelectricity. We provide here a general explanation which is rooted in established science. When sliding is taking place, there is symmetry breaking due to elastic shear, so the front of the sliding body experiences different elastic strains from the back. Consequently the polarization and associated charges at the front and back are not the same, and the difference between the two leads to current flow similar to the difference in air pressure above and below a plane's wing leading to lift. Specific calculations are provided which show good agreement with prior experimental measurements of size and shape dependencies, and reasonable quantitative agreement with experimental current measurements.

2.
Article in English | MEDLINE | ID: mdl-39285787

ABSTRACT

PURPOSE: The aim of this study was to investigate the influence of medial meniscus posterior root avulsion (MMPRA) before and after surgical treatment on the biomechanics of the knee joint, including suture repair forces during daily and crutch-assisted gait movements. METHODS: MMPRA were investigated in eight human cadaver knee joint specimens by a dynamic knee joint simulator with daily (normal gait, gait with additional rotational movement, standing up, sitting down) and rehabilitation-associated movements (crutch-assisted gait with limited flexion range of motion [30°] and 30% [toe-touch weight-bearing, TTWB] and 50% of body weight [partial weight-bearing, PWB]) with simulated physiologic muscle forces. Each specimen was tested in intact, torn and repaired (transtibial suture) state. The biomechanical parameters were: medial mean contact pressure and area, knee joint kinematics, medial displacement of the posterior meniscus horn and loading on the anchoring suture. RESULTS: Significant reduction of the contact area due to the avulsion was observed in all movements except for PWB and sitting down. MMPRA repair significantly increased the contact areas during all movements, bringing them to levels statistically indistinguishable from the initial state. MMPRA resulted in a medial displacement up to 12.8 mm (sitting down) and could be reattached with a residual displacement ranging from 0.7 mm (PWB) to 5.7 mm (standing up), all significantly (p < 0.001) reduced compared to the torn state. The mean peak anchoring suture load increased from TTWB (77 N), PWB (91 N) to normal gait (194 N), gait rotation (207 N), sitting (201 N; p < 0.01) and to standing up (232 N; p = 0.03). CONCLUSION: Surgical treatment of MMPRA allows restoration of physiological knee joint biomechanics. Crutch-assisted movements reduce the loading of the repair suture, thus likewise the risk for failure. From a biomechanical point of view, crutch-assisted movements are recommended for the early rehabilitation phase after MMPRA repair. LEVEL OF EVIDENCE: Level V.

3.
Sci Rep ; 14(1): 18267, 2024 08 06.
Article in English | MEDLINE | ID: mdl-39107360

ABSTRACT

In many insects the surface of the eye is nanostructured by arrays of protuberances termed ommatidial gratings which provide the cuticle with anti-reflective, anti-wetting and self-cleaning properties. The hypothesised anti-contamination role of the gratings against dust and pollen results from theoretical predictions on grating geometry and experiments on synthetic replicas of ommatidia surfaces but has not yet been proven in an animal. Whiteflies are biological test beds for anti-contamination surfaces because they deliberately distribute wax particles extruded from abdominal plates over their entire bodies. The numerous particles protect the animal against water evaporation and radiation, but may severely impair vision. Using scanning electron microscopy (SEM) and CryoSEM, we here show that the cornea of whiteflies exhibits ~ 220 nm wide mesh-like structures forming hexagonal gratings with thin ~ 40 nm connecting walls. Quantitative measurements of wax particles on the eye show that the nanostructures reduce particle contamination by more than ~ 96% compared to other areas of the cuticle. Altogether, our study is the first description of a predicted optimized grating geometry for anti-contamination in an arthropod. The findings serve as evidence of the high effectiveness of nanostructured surfaces for reducing contact area and thus adhesion forces between biological surfaces and contaminating particles.


Subject(s)
Hemiptera , Nanostructures , Animals , Nanostructures/chemistry , Hemiptera/physiology , Eye , Microscopy, Electron, Scanning , Surface Properties , Waxes/chemistry
4.
Philos Trans A Math Phys Eng Sci ; 382(2278): 20230356, 2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39069762

ABSTRACT

Predicting failure initiation in nonlinear composite materials, often referred to as metamaterials, is a fundamental challenge in nonlinear solid mechanics. Microstructural failure mechanisms encompass fracture, decohesion, cavitation, compression-induced contact and instabilities, affecting their unconventional static and dynamic performances. To fully take advantage of these materials, especially in extreme applications, it is imperative to predict their nonlinear behaviour using reliable, accurate and computationally efficient numerical methodologies. This study presents an innovative nonlinear homogenization-based theoretical framework for characterizing the failure behaviour of periodic reinforced hyperelastic composites induced by reinforcement/matrix decohesion and interaction between contact mechanisms and microscopic instabilities. Debonding and unilateral contact between different phases are incorporated by employing an enhanced cohesive/contact model, which features a special nonlinear interface constitutive law and an accurate contact formulation within the context of finite strain continuum mechanics. The theoretical formulation is demonstrated using periodically layered composites subjected to macroscopic compressive loading conditions along the lamination direction. Numerical results illustrate the ways in which debonding phenomena, in conjunction with fibre microbuckling, may influence the critical loads of the examined composite solid. The sensitivity of the results obtained through the proposed contact-cohesive model at finite strain with respect to its implementation is also explored. This article is part of the theme issue 'Current developments in elastic and acoustic metamaterials science (Part 1)'.

5.
Philos Trans A Math Phys Eng Sci ; 382(2276): 20230420, 2024 Aug 09.
Article in English | MEDLINE | ID: mdl-38945160

ABSTRACT

Hydraulic stimulation is a critical process for increasing the permeability of fractured geothermal reservoirs. This technique relies on coupled hydromechanical processes induced through pressurized fluid injection into the rock formation. The injection of fluids causes poromechanical stress changes that can lead to fracture slip and shear dilation, as well as tensile fracture opening and propagation, so-called mixed-mechanism stimulation. The effective permeability of the rock is particularly enhanced when new fractures connect with pre-existing fractures. While hydraulic stimulation can significantly improve the productivity of fractured geothermal reservoirs, the process is also related to induced seismicity. Hence, understanding the coupled physics is central, for both reservoir engineering and seismic risk mitigation. This article presents a modelling approach for simulating the deformation, propagation and coalescence of fractures in porous media under the influence of anisotropic stress and fluid injection. It uses a coupled hydromechanical model for poroelastic, fractured media. Fractures are governed by contact mechanics and a fracture propagation model. For numerical solutions, we employ a two-level approach, combining a finite volume method for poroelasticity with a finite element method for fracture propagation. The study investigates the impact of injection rate, matrix permeability and stress anisotropy on stimulation outcomes.This article is part of the theme issue 'Induced seismicity in coupled subsurface systems'.

6.
Biomech Model Mechanobiol ; 23(5): 1607-1616, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38763978

ABSTRACT

Haemarthrosis is an inherent clinical feature of haemophilia, a disease characterised by an absence or reduction in clotting proteins. Patients with severe haemophilia experience joint bleeding leading to blood-induced ankle arthropathy (haemarthropathy). Altered biomechanics of the ankle have been reported in people with haemophilia; however, the consequence of this on joint health is little understood. The aim of this study was to assess the changes in joint contact due to haemophilia disease-specific gait features using patient-specific modelling, to better understand the link between biomechanics and joint outcomes. Four, image-based, finite element models of haemophilic ankles were simulated through consecutive events in the stance phase of gait, using both patient-specific and healthy control group (n = 36) biomechanical inputs. One healthy control FE model was simulated through the healthy control stance phase of the gait cycle for a point of comparison. The method developed allowed cartilage contact mechanics to be assessed throughout the loading phase of the gait cycle. This showed areas of increased contact pressure in the medial and lateral regions of the talar dome, which may be linked to collapse in these regions. This method may allow the relationship between structure and function in the tibiotalar joint to be better understood.


Subject(s)
Ankle Joint , Finite Element Analysis , Gait , Hemophilia A , Humans , Hemophilia A/physiopathology , Hemophilia A/complications , Gait/physiology , Ankle Joint/physiopathology , Biomechanical Phenomena , Adult , Male , Patient-Specific Modeling , Case-Control Studies , Young Adult , Pressure , Models, Biological , Middle Aged
7.
J Orthop ; 55: 118-123, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38665988

ABSTRACT

Objective: This investigation aimed to assess the impact of obesity on the load-transfer mechanism, longevity, and contact mechanics of cemented acetabular cups. Methods: Three obesity scenarios were considered: obese case-I (100-110 kg), obese case-II (120-130 kg), and obese case-III (140-150 kg). Utilising six finite element models, the effects of different bodyweights on load transfer, contact mechanics, and cup longevity during normal walking conditions were assessed. Muscle forces and hip joint reaction forces were adjusted and linearly calibrated based on obesity cases. Results: Elevated stresses in cortical and cancellous bones, as well as the cement mantle, were observed in obese cases, suggesting a heightened risk of loosening and failure of the cemented fixation of the acetabular cup. Additionally, increased contact pressure and micromotion between articulating surfaces were noted in obese individuals, with a gradual escalation from obese case-I to obese case-III. Conclusions: These findings highlight the significant negative impact of obesity on the performance of cemented acetabular cups, emphasizing the importance of considering bodyweight variations in the design and assessment of orthopaedic implants for optimal functionality and durability.

8.
Biomech Model Mechanobiol ; 23(3): 1055-1065, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38349433

ABSTRACT

Finite element studies of the tibiofemoral joint have increased use in research, with attention often placed on the material models. Few studies assess the effect of meniscus modelling assumptions in image-based models on contact mechanics outcomes. This work aimed to assess the effect of modelling assumptions of the meniscus on knee contact mechanics and meniscus kinematics. A sensitivity analysis was performed using three specimen-specific tibiofemoral models and one generic knee model. The assumptions in representing the meniscus attachment on the tibia (shape of the roots and position of the attachment), the material properties of the meniscus, the shape of the meniscus and the alignment of the joint were evaluated, creating 40 model instances. The values of material parameters for the meniscus and the position of the root attachment had a small influence on the total contact area but not on the meniscus displacement or the force balance between condyles. Using 3D shapes to represent the roots instead of springs had a large influence in meniscus displacement but not in knee contact area. Changes in meniscus shape and in knee alignment had a significantly larger influence on all outcomes of interest, with differences two to six times larger than those due to material properties. The sensitivity study demonstrated the importance of meniscus shape and knee alignment on meniscus kinematics and knee contact mechanics, both being more important than the material properties or the position of the roots. It also showed that differences between knees were large, suggesting that clinical interpretations of modelling studies using single geometries should be avoided.


Subject(s)
Femur , Finite Element Analysis , Menisci, Tibial , Models, Biological , Tibia , Humans , Femur/physiology , Femur/anatomy & histology , Biomechanical Phenomena , Tibia/physiology , Tibia/anatomy & histology , Menisci, Tibial/physiology , Menisci, Tibial/anatomy & histology , Meniscus/physiology , Meniscus/anatomy & histology , Knee Joint/physiology , Knee Joint/anatomy & histology
9.
ACS Appl Mater Interfaces ; 16(8): 9614-9625, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38378485

ABSTRACT

Bacteria are mechanically resistant biological structures that can sustain physical stress. Experimental data, however, have shown that high-aspect-ratio nanopillars deform bacterial cells upon contact. If the deformation is sufficiently large, it lyses the bacterial cell wall, ultimately leading to cell death. This has prompted a novel strategy, known as mechano-bactericide technology, to fabricate antibacterial surfaces. Although adhesion forces were originally proposed as the driving force for mechano-bactericidal action, it has been recently shown that external forces, such as capillary forces arising from an air-water interface at bacterial surfaces, produce sufficient loads to rapidly kill bacteria on nanopillars. This discovery highlights the need to theoretically examine how bacteria respond to external loads and to ascertain the key factors. In this study, we developed a finite element model approximating bacteria as elastic shells filled with cytoplasmic fluid brought into contact with an individual nanopillar or nanopillar array. This model elucidates that bacterial killing caused by external forces on nanopillars is influenced by surface topography and cell biomechanical variables, including the density and arrangement of nanopillars, in addition to the cell wall thickness and elastic modulus. Considering that surface topography is an important design parameter, we performed experiments using nanopillar arrays with precisely controlled nanopillar diameters and spacing. Consistent with model predictions, these demonstrate that nanopillars with a larger spacing increase bacterial susceptibility to mechanical puncture. The results provide salient insights into mechano-bactericidal activity and identify key design parameters for implementing this technology.


Subject(s)
Nanostructures , Nanostructures/chemistry , Biomechanical Phenomena , Bacteria , Cell Wall
10.
Proc Inst Mech Eng H ; 238(2): 237-249, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38229467

ABSTRACT

Computational models of the hip often omit patient-specific functional orientation when placing imaging-derived bony geometry into anatomic landmark-based coordinate systems for application of joint loading schemes. The purpose of this study was to determine if this omission meaningfully alters computed contact mechanics. Discrete element analysis models were created from non-weightbearing (NWB) clinical CT scans of 10 hip dysplasia patients (11 hips) and oriented in the International Society of Biomechanics (ISB) coordinate system (NWB-ISB). Three additional models were generated for each hip by adding patient-specific stance information obtained via weightbearing CT (WBCT) to each ISB-oriented model: (1) patient-specific sagittal tilt added (WBCT-sagittal), (2) coronal and axial rotation from optical motion capture added to (1; WBCT-combo), and (3) WBCT-derived axial, sagittal, and coronal rotation added to (1; WBCT-original). Identical gait cycle loading was applied to all models for a given hip, and computed contact stress and contact area were compared between model initialization techniques. Addition of sagittal tilt did not significantly change whole-joint peak (p = 0.922) or mean (p = 0.871) contact stress or contact area (p = 0.638). Inclusion of motion-captured coronal and axial rotation (WBCT-combo) decreased peak contact stress (p = 0.014) and slightly increased average contact area (p = 0.071) from WBCT-sagittal models. Including all WBCT-derived rotations (WBCT-original) further reduced computed peak contact stress (p = 0.001) and significantly increased contact area (p = 0.001). Variably significant differences (p = 0.001-1.0) in patient-specific acetabular subregion mechanics indicate the importance of functional orientation incorporation for modeling applications in which local contact mechanics are of interest.


Subject(s)
Hip Dislocation , Humans , Hip Dislocation/surgery , Acetabulum/diagnostic imaging , Acetabulum/surgery , Tomography, X-Ray Computed/methods , Osteotomy/methods , Weight-Bearing , Hip Joint/diagnostic imaging , Hip Joint/surgery
11.
J Orthop Res ; 42(5): 1134-1144, 2024 May.
Article in English | MEDLINE | ID: mdl-37986646

ABSTRACT

Meniscal tearing can increase the contact pressure between the tibia and femur by causing gapping of torn meniscus tissue. The aim of this study was to quantify gapping behavior of radial and longitudinal tears and their impact on peak contact pressure and mean contact area. Twelve porcine knee joints underwent unicondylar, convertible osteotomy for exact tear application and consecutive suturing. Six tantalum marker beads were positioned along meniscus tears. The joints were preloaded with sinusoidal loading cycles ranging between 0 N and 350 N. Peak load was held constant and two synchronized Roentgen stereophotogrammetric analysis x-ray images were obtained to evaluate gapping, peak contact pressure and mean contact area in the native, torn and repaired states. There was no change in gapping or peak contact pressure in longitudinal tear. By contrast, the radial tear led to a significant gapping when compared to the native state, while the inside-out suture was able to restore gapping in parts of the meniscus. An increase in contact pressure after radial tear was detected, which was again normalized after suturing. The most important finding of the study is that longitudinal tears did not gap under pure axial loading, whereas radial tears tended to separate the tear interfaces.


Subject(s)
Meniscus , Tibial Meniscus Injuries , Animals , Swine , Menisci, Tibial/diagnostic imaging , Menisci, Tibial/surgery , Tibial Meniscus Injuries/surgery , Biomechanical Phenomena , Knee Joint/surgery , Rupture
12.
Ultrason Sonochem ; 101: 106713, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38056086

ABSTRACT

Ultrasonic technology is widely applied in the engineering ceramic polishing processes without the limitation of material properties and ideally integrated into computer numerical control system. Ultrasonic-induced cavitation and mechanical vibration effect could accelerate the motion of solid abrasives. The individual behaviors of microjet/shockwave of ultrasonic cavitation in gases and liquids, and micro-abrasives with simple harmonic vibrations in solids and liquids has been extensively studied. To conduct a systematic and integrated study of abrasives behavior in the polishing contact region involving abrasive, surround-workpiece wall, ultrasonic physical vibration, and ultrasonic cavitation impact, a novel model integrating the free abrasive motion velocity and fixed abrasive indentation depth under multi-scale contact was proposed according to Hertzian contact theory, Greenwood-Williamson model, indentation deformation theory, the basic equations of cavitation bubble dynamics, cavitation impact control equations, and Newton's law of motion equation. The effects of ultrasonic amplitude, ultrasonic frequency, preloading force and particle size on the proposed model were investigated by theoretical analysis and numerical simulations. Ultrasonic physical vibration mainly influences the dynamic gap and further influence the number of different abrasives. Furthermore, the indentation depth of fixed abrasive depends mainly on the abrasive geometry. As the contact gap and abrasive size decrease, the indentation depth gradually decreases. Under the synergistic effect of cavitation-induced shock wave and microjet, the velocity of free abrasive in this paper is generally 0-150 m/s, and the kinetic energy of free abrasive increases roughly linearly with increasing frequency and approximately as a quadratic function with increasing particle size. Increasing the preloading force leads to a reduction in the abrasive kinetic energy. Besides, the kinetic energy induced by the shock wave has a cliff-like increment at an amplitude of 0.7-0.8 µm. It is revealed that the abrasive kinetic energy is suppressed by the cavitation bubble expansion and collapse at smaller ultrasonic pressure amplitude and surround-wall distance. This research provides a theoretical reference for the modeling of potential defects and material removal on the workpiece surface caused by abrasive motion during polishing, and reduces the trial cost for parameter optimization in actual polishing processing.

13.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(6): 1192-1199, 2023 Dec 25.
Article in Chinese | MEDLINE | ID: mdl-38151943

ABSTRACT

The clinical performance and failure issues are significantly influenced by prosthetic malposition in unicompartmental knee arthroplasty (UKA). Uncertainty exists about the impact of the prosthetic joint line height in UKA on tibial insert wear. In this study, we combined the UKA musculoskeletal multibody dynamics model, finite element model and wear model to investigate the effects of seven joint line height cases of fixed UKA implant on postoperative insert contact mechanics, cumulative sliding distance, linear wear depth and volumetric wear. As the elevation of the joint line height in UKA, the medial contact force and the joint anterior-posterior translation during swing phase were increased, and further the maximum von Mises stress, contact stress, linear wear depth, cumulative sliding distance, and the volumetric wear also were increased. Furthermore, the wear area of the insert gradually shifted from the middle region to the rear. Compared to 0 mm joint line height, the maximum linear wear depth and volumetric wear were decreased by 7.9% and 6.8% at -2 mm joint line height, and by 23.7% and 20.6% at -6 mm joint line height, the maximum linear wear depth and volumetric wear increased by 10.7% and 5.9% at +2 mm joint line height, and by 24.1% and 35.7% at +6 mm joint line height, respectively. UKA prosthetic joint line installation errors can significantly affect the wear life of the polyethylene inserted articular surfaces. Therefore, it is conservatively recommended that clinicians limit intraoperative UKA joint line height errors to -2-+2 mm.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Knee Joint , Mechanical Phenomena , Polyethylene , Osteoarthritis, Knee/surgery , Tibia/surgery , Biomechanical Phenomena
14.
Materials (Basel) ; 16(19)2023 Sep 29.
Article in English | MEDLINE | ID: mdl-37834628

ABSTRACT

Structured surfaces, which are the basis of the lotus blossom effect, have great potential to serve/operate as functionalised surfaces, i.e., surfaces with specific and/or adjustable properties. In the present study, the aim is to use micro-structured elastomeric surfaces to specifically influence the friction and deformation behaviours on the basis of the shape and arrangement of the structures. Thiol-acrylate-based photopolymers patterned via nanoimprint lithography were investigated by using an in situ tribological measurement set-up. A clear influence of the different structures on the surface's friction behaviour could be shown, and, furthermore, this could be brought into relation with the real area of contact. This finding provides an important contribution to further development steps, namely, to give the structures switchable properties in order to enable the control of friction properties in a targeted manner.

15.
Acta Biomater ; 170: 519-531, 2023 Oct 15.
Article in English | MEDLINE | ID: mdl-37659729

ABSTRACT

Understanding the principles underlying the self-organization of stem cells into tissues is fundamental for deciphering human embryo development. Here, we report that, without three-dimensional (3D) extracellular matrix (ECM) overlay, human pluripotent stem cells (hPSCs) cultured on two-dimensional soft elastic substrates can self-organize into 3D cysts resembling the human epiblast sac in a stiffness-dependent manner. Our theoretical modeling predicts that this cyst organization is facilitated and guided by the spontaneous nesting of the soft substrate, which results from the adhesion-dependent mechanical interaction between cells and substrate. Such substrate nesting is sufficient for the 3D assembly and polarization of hPSCs required for cyst organization, even without 3D ECM overlay. Furthermore, we identify that the reversible substrate nesting and cyst morphogenesis also require appropriate activation of ROCK-Myosin II pathway. This indicates a unique set of tissue morphomechanical signaling mechanisms that clearly differ from the canonical cystogenic mechanism previously reported in 3D ECM. Our findings highlight an unanticipated synergy between mechanical microenvironment and mechanotransduction in controlling tissue morphogenesis and suggest a mechanics-based strategy for generation of hPSCs-derived models for early human embryogenesis. STATEMENT OF SIGNIFICANCE: Soft substrates can induce the self-organization of human pluripotent stem cells (hPSCs) into cysts without three-dimensional (3D) extracellular matrix (ECM) overlay. However, the underlying mechanisms by which soft substrate guides cystogenesis are largely unknown. This study shows that substrate nesting, resulting from cell-substrate interaction, plays an important role in cyst organization, including 3D assembly and apical-basal polarization. Additionally, actomyosin contractility mediated by the ROCK-Myosin II pathway also contributes to the substrate deformation and cyst morphology. These findings demonstrate the interplay between the mechanical microenvironment and cells in tissue morphogenesis, suggesting a mechanics-based strategy in building hPSC-derived models for early human embryo development.

16.
J Clin Med ; 12(15)2023 Jul 26.
Article in English | MEDLINE | ID: mdl-37568320

ABSTRACT

BACKGROUND: Elliptical humeral head implants have been proposed to result in more anatomic kinematics following total shoulder arthroplasty (aTSA). The purpose of this study was to compare glenohumeral contact mechanics during axial rotation using spherical and elliptical humeral head implants in the setting of aTSA. METHODS: Seven fresh-frozen cadaveric shoulders were utilized for biomechanical testing in neutral (NR), internal (IR), and external (ER) rotation at various levels of abduction (0°, 15°, 30°, 45°, 60°) with lines of pull along each of the rotator cuff muscles. Each specimen underwent the following three conditions: (1) native, and TSA using (2) an elliptical and (3) spherical humeral head implant. Glenohumeral contact mechanics, including contact pressure (CP; kPa), peak contact pressure (PCP; kPa), and contact area (CA; mm2), were measured in neutral rotation as well as external and internal rotation using a pressure mapping sensor. RESULTS: Elliptical head implants showed a significantly lower PCP in ER compared to spherical implants at 0° (Δ-712.0 kPa; p = 0.034), 15° (Δ-894.9 kPa; p = 0.004), 30° (Δ-897.7 kPa; p = 0.004), and 45° (Δ-796.9 kPa; p = 0.010) of abduction, while no significant difference was observed in ER at 60° of abduction or at all angles in NR and IR. Both implant designs had similar CA in NR, ER, and IR at all tested angles of abduction (p > 0.05, respectively). CONCLUSIONS: In the setting of aTSA, elliptical heads showed significantly lower PCP during ER at 0° to 45° of abduction, when compared to spherical head implants. However, in NR and IR, PCP was similar between implant designs. Both designs showed similar CA during NR, ER, and IR at all abduction angles. LEVEL OF EVIDENCE: basic science; controlled laboratory study.

17.
J Appl Biomech ; 39(6): 388-394, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37633654

ABSTRACT

It is not currently possible to directly and noninvasively measure in vivo patellofemoral joint contact force during dynamic movement; therefore, indirect methods are required. Simple models may be inaccurate because patellofemoral contact forces vary for the same knee flexion angle, and the patellofemoral joint has substantial out-of-plane motion. More sophisticated models use 3-dimensional kinematics and kinetics coupled to a subject-specific anatomical model to predict contact forces; however, these models are time consuming and expensive. We applied a principal component analysis prediction and regression method to predict patellofemoral joint contact forces derived from a robust musculoskeletal model using exclusively optical motion capture kinematics (external approach), and with both patellofemoral and optical motion capture kinematics (internal approach). We tested this on a heterogeneous population of asymptomatic subjects (n = 8) during ground-level walking (n = 12). We developed equations that successfully capture subject-specific gait characteristics with the internal approach outperforming the external. These approaches were compared with a knee-flexion based model in literature (Brechter model). Both outperformed the Brechter model in interquartile range, limits of agreement, and the coefficient of determination. The equations generated by these approaches are less computationally demanding than a musculoskeletal model and may act as an effective tool in future rapid gait analysis and biofeedback applications.


Subject(s)
Patellofemoral Joint , Humans , Knee Joint/surgery , Gait , Walking , Biomechanical Phenomena
18.
ACS Appl Mater Interfaces ; 15(31): 37401-37409, 2023 Aug 09.
Article in English | MEDLINE | ID: mdl-37490287

ABSTRACT

All-solid-state batteries (ASSB) can potentially achieve high gravimetric and volumetric energy densities (900 Wh/L) if paired with a lithium metal anode and solid electrolyte. However, there is a lack in critical understanding about how to operate lithium metal cells at high capacities and minimize unwanted degradation mechanisms such as dendrites and voids. Herein, we investigate how pressure and temperature influence the formation and annihilation of unrecoverable voids in lithium metal upon stripping. Stack pressure and temperature are effective means to initiate creep-induced void filling and decrease charge transfer resistances. Applying stack pressure enables lithium to deform and creep below the yield stress during stripping at high current densities. Lithium creep is not sufficient to prevent cell shorting during plating. Three-electrode experiments were employed to probe the kinetic and morphological limitations that occur at the anode-solid electrolyte during high-capacity stripping (5 mAh/cm2). The role of cathode-LLZO interface, which dictates cyclability and capacity retention in full cells, was also studied. This work elucidates the important role that temperature (external or in situ generated) has on reversible operation of solid-state batteries.

19.
HardwareX ; 14: e00437, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37346967

ABSTRACT

A new hardware is described to quantify the particle surface energy by assuming that the Johnson Kendall and Roberts theory of elastic-adhesive contacts is applicable. The setup is used in the active section of the measurement, where newly designed elements provide the sharp impact needed to detach the particles under the action of their own kinetic energy. It employs a selection of sensors to provide the necessary measurements in a streamlined procedure, which lets the user complete one test in less than one minute. The temporal resolution is 1µs for the contact time measurement and the velocity has a repeatability of 1%. The surface energy is a significant parameter for the characterisation of particulate materials and is widely used in Discrete Element simulations of the bulk behaviour.

20.
Article in English | MEDLINE | ID: mdl-37128680

ABSTRACT

Despite availability of in vivo knee loads and kinematics data, conventional load- and displacement-controlled configurations still can't accurately predict tibiofemoral loads from kinematics or vice versa. We propose a combined load- and displacement-control method for joint-level simulations of the knee to reliably reproduce in vivo contact mechanics. Prediction errors of the new approach were compared to those of conventional purely load- or displacement-controlled models using in vivo implant loads and kinematics for multiple subjects and activities (CAMS-Knee dataset). Our method reproduced both loads and kinematics more closely than conventional models and thus demonstrates clear advantages for investigating tibiofemoral contact or wear.