Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 124
Filter
1.
Adv Sci (Weinh) ; : e2309170, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38952062

ABSTRACT

The long-term durability of triboelectric nanogenerators (TENGs) remains a main challenge for practical applications because of inevitable material abrasion and wear, especially for sliding TENGs. Herein, an inorganic triboelectric pair composed of diamond-like carbon (DLC) and glass with excellent durability and triboelectric output for sliding-mode TENGs is proposed. This triboelectric pair possesses a low coefficient of friction and little abrasion and accordingly excellent durability (>500 000 cycles). Moreover, compared with the traditional copper-polytetrafluoroethylene (Cu-PTFE) TENG with maximum transferred charges of 50 nC, those of the DLC-glass TENG reaches 141 nC. Due to the low-friction and high hardness of the triboelectric pair, the output quickly recovers after simply cleaning wear debris. The DLC-glass TENG demonstrates an output power density of 530 mW m-2 and a fourfold faster capacitor charging speed than the Cu-PTFE TENG. Compared to the reported durable TENGs via structure optimization and interface lubrication, the DLC-glass TENG shows higher outputs and simpler structure. This DLC-glass pair structure is also introduced into a spherical TENG for blue energy harvesting with excellent durability. The inorganic triboelectric pair with excellent mechanical durability and electrical performance proposed in this work shows huge prospects for practical applications of TENGs.

2.
ACS Appl Mater Interfaces ; 16(22): 29314-29323, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38770841

ABSTRACT

Dopants and alloying elements are commonly introduced in amorphous carbon (a-C) materials to tailor their mechanical and tribological properties. While most published studies have focused on doping and alloying a-C coatings with metals or metalloids, doping a-C films with rare-earth elements has only recently been explored. Notably, our understanding of the shear-induced structural changes occurring in rare-earth-element-containing a-C films is still elusive, even in the absence of any liquid lubricants. Here, the friction response of Eu- and Gd-containing a-C films with low hydrogen content deposited by HiPIMS on silicon was evaluated in open air and at room temperature. The load-dependent friction measurements indicated that the introduction of Gd ((2.3 ± 0.1) at.%) and Eu ((2.4 ± 0.1) at.%) into the a-C matrix results in a significant reduction of the shear strength of the sliding interfaces ((41 ± 2) MPa for a-C, (16 ± 1) MPa for a-C:Gd2.3 at.%, and (11 ± 2) MPa for a-C:Eu2.4 at.%). NEXAFS spectromicroscopy experiments provided evidence that no stress-assisted sp3-to-sp2 rehybridization of carbon atoms was induced by the sliding process in the near-surface region of undoped a-C, while the amount of sp2-bonded carbon progressively increased in a-C:Gd2.3 at.% and a-C:Eu2.4 at.% upon increasing the applied normal load in tribological tests. The formation of an sp2-bonded carbon-rich surface layer in a-C:Gd2.3 at.% and a-C:Eu2.4 at.% films was not only proposed to be the origin for the reduced duration of the running-in period in tribological test, but was also postulated to induce shear localization within the sp2-carbon-rich layer and transfer film formation on the countersurface, thus decreasing the interfacial shear strength. These findings open the path for the use of Gd- and Eu-containing a-C even under critical conditions for nearly hydrogen-free a-C films (i.e., humid air).

3.
Materials (Basel) ; 17(10)2024 May 17.
Article in English | MEDLINE | ID: mdl-38793487

ABSTRACT

The wall friction angle is an important parameter in powder flow. In a recent study for various powders, a reduction in the wall friction angle for steel was demonstrated by the application of an a-C:H:Si film on the steel surface. This work presents the results of a study of this effect in more detail regarding the influence of the powder material, the wall normal stress and the particle size of the powder for mass median diameters from 4 µm to approximately 150 µm. The wall friction angles were measured using a Schulze ring shear tester for three different powder materials: aluminum oxide, calcium carbonate and silicon carbide. The results showed little difference with respect to powder chemistry. For the coarser powders, the reduction in the wall friction angle due to the a-C:H:Si coating was highest (10° to 12°) and rather stress-independent, while for the fine and medium-size powders the reduction was lower and stress-dependent. With increasing wall normal stress, the reduction in the wall friction angle increased. These results can be explained by the friction reduction mechanism of a-C:H:Si, which requires a certain contact pressure for superficial graphitization.

4.
Nanomicro Lett ; 16(1): 186, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38687411

ABSTRACT

Post-traumatic peritendinous adhesion presents a significant challenge in clinical medicine. This study proposes the use of diamond-like carbon (DLC) deposited on polylactic acid (PLA) membranes as a biophysical mechanism for anti-adhesion barrier to encase ruptured tendons in tendon-injured rats. The results indicate that PLA/DLC composite membrane exhibits more efficient anti-adhesion effect than PLA membrane, with histological score decreasing from 3.12 ± 0.27 to 2.20 ± 0.22 and anti-adhesion effectiveness increasing from 21.61% to 44.72%. Mechanistically, the abundant C=O bond functional groups on the surface of DLC can reduce reactive oxygen species level effectively; thus, the phosphorylation of NF-κB and M1 polarization of macrophages are inhibited. Consequently, excessive inflammatory response augmented by M1 macrophage-originated cytokines including interleukin-6 (IL-6), interleukin-1ß (IL-1ß), and tumor necrosis factor-α (TNF-α) is largely reduced. For biocompatibility evaluation, PLA/DLC membrane is slowly absorbed within tissue and displays prolonged barrier effects compared to traditional PLA membranes. Further studies show the DLC depositing decelerates the release of degradation product lactic acid and its induction of macrophage M2 polarization by interfering esterase and PLA ester bonds, which further delays the fibrosis process. It was found that the PLA/DLC membrane possess an efficient biophysical mechanism for treatment of peritendinous adhesion.

5.
Int J Mol Sci ; 25(5)2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38474083

ABSTRACT

Diamond-like carbon (DLC) layers are known for their high corrosion and wear resistance, low friction, and high biocompatibility. However, it is often necessary to dope DLC layers with additional chemical elements to strengthen their adhesion to the substrate. Ti-DLC layers (doped with 0.4, 2.1, 3.7, 6.6, and 12.8 at.% of Ti) were prepared by dual pulsed laser deposition, and pure DLC, glass, and polystyrene (PS) were used as controls. In vitro cell-material interactions were investigated with an emphasis on cell adhesion, proliferation, and osteogenic differentiation. We observed slightly increasing roughness and contact angle and decreasing surface free energy on Ti-DLC layers with increasing Ti content. Three-week biological experiments were performed using adipose tissue-derived stem cells (ADSCs) and bone marrow mesenchymal stem cells (bmMSCs) in vitro. The cell proliferation activity was similar or slightly higher on the Ti-doped materials than on glass and PS. Osteogenic cell differentiation on all materials was proved by collagen and osteocalcin production, ALP activity, and Ca deposition. The bmMSCs exhibited greater initial proliferation potential and an earlier onset of osteogenic differentiation than the ADSCs. The ADSCs showed a slightly higher formation of focal adhesions, higher metabolic activity, and Ca deposition with increasing Ti content.


Subject(s)
Arthroplasty, Replacement , Mesenchymal Stem Cells , Titanium/chemistry , Surface Properties , Carbon/chemistry , Osteogenesis , Cell Differentiation , Mesenchymal Stem Cells/metabolism
6.
Small ; : e2400513, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38545999

ABSTRACT

Hydrogenated diamond-like carbon (HDLC) is a promising solid lubricant for its superlubricity which can benefit various industrial applications. While HDLC exhibits notable friction reduction in macroscale tests in inert or reducing environmental conditions, ultralow friction is rarely observed at the nanoscale. This study investigates this rather peculiar dependence of HDLC superlubricity on the contact scale. To attain superlubricity, HDLC requires i) removal of ≈2 nm-thick air-oxidized surface layer and ii) shear-induced transformation of amorphous carbon to highly graphitic and hydrogenated structure. The nanoscale wear depth exceeds the typical thickness of the air-oxidized layer, ruling out the possibility of incomplete removal of the air-oxidized layer. Raman analysis of transfer films indicates that shear-induced graphitization readily occurs at shear stresses lower than or comparable to those in the nanoscale test. Thus, the same is expected to occur at the nanoscale test. However, the graphitic transfer films are not detected in ex-situ analyses after nanoscale friction tests, indicating that the graphitic transfer films are pushed out of the nanoscale contact area due to the instability of transfer films within a small contact area. Combining all these observations, this study concludes the retention of highly graphitic transfer films is crucial to achieving HDLC superlubricity.

7.
ACS Appl Mater Interfaces ; 16(14): 18090-18098, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38533722

ABSTRACT

Multilayer coatings offer significant advantages in protecting materials' surfaces by shielding the underlying materials hierarchically from damage and wear. The layering morphology and structure of multilayer coatings directly affect their wear resistance capacity. Using a systematic set of experiments and molecular dynamics (MD) simulations, we studied the effect of layering thickness on the macroscale wear response of DLC/WC multinanolayer coatings. Our study revealed the existence of a critical bilayer thickness where maximum scratch hardness and wear resistance can be achieved. Our large-scale MD simulations showed that reducing the WC layer thickness to a certain limit increases the scratch hardness due to the confinement of dislocation motion. However, when the thickness of the WC layers falls below 2 nm, the deformation mechanism transitions from the interface-induced dislocation confinement to the interface-mediated amorphization of WC layers, reducing the scratch hardness of the coating. This finding offers a procedure for optimizing the macroscale wear performance of multinanolayer coatings.

8.
ACS Appl Mater Interfaces ; 16(14): 18112-18123, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38547870

ABSTRACT

Boron doping of diamond-like carbon coatings has multiple effects on their tribological properties. While boron typically reduces wear in cutting applications, some B-doped coatings show poor tribological performance compared with undoped films. This is the case of the tribological tests presented in this work in which an alumina ball is placed in frictional contact with different undoped and B-doped amorphous carbon coatings in humid air. With B-doped coatings, a higher friction coefficient at a steady state with respect to their undoped counterparts was observed. Estimates of the average contact shear stress based on experimental friction coefficients, surface topographies, and Persson's contact theory suggest that the increased friction is compatible with the formation of a sparse network of interfacial ether bonds leading to a mild cold-welding friction regime, as documented in the literature. Tight binding and density functional theory simulations were performed to investigate the chemical effect of B-doping on the interfacial properties of the carbon coatings. The results reveal that OH groups that normally passivate carbon surfaces in humid environments can be activated by boron and form B-O dative bonds across the tribological interfaces, leading to a mild cold-welding friction regime. Simulations performed on different tribological pairs suggest that this mechanism could be valid for B-doped carbon surfaces in contact with a variety of materials. In general, this study highlights the impact that subtle modifications in surface and interface chemistry caused by the presence of impurities can have on macroscopic properties, such as friction and wear.

9.
J Mol Model ; 30(2): 28, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38194121

ABSTRACT

CONTEXT: Diamond-like carbon (DLC) films are amorphous solids in which carbon atoms are linked by hybridized sp3, sp2, and sp bonds. The mechanical and tribological properties of DLC films can be adjusted by tuning the sp2/sp3 bond ratio. These films are typically used as protective coatings for components such as dies, automotive engines, mechanical seals, hard disk drives, biological engineering devices, and micro/nano-electromechanical systems. Further exploration of the mechanical and tribological behavior of DLC films is important for enhancing functional design for the above applications. The simulation results show that single-layer DLC with a higher sp3 ratio has better resistance to indentation. Single-layer DLC with a lower initial sp3 ratio has lower friction and a shorter repeated cycle in the friction force curve due to an increase in the graphitization of the friction interface. Single-layer DLC with a higher sp3 ratio has a higher coefficient of friction because compared with the normal force, the friction force is much more sensitive to an increase in the sp3 ratio. METHODS: Molecular dynamics simulations based on the Tersoff potential were performed using the open-source code LAMMPS (Large-scale Atomic/Molecular Massively Parallel Simulator).

10.
ACS Appl Mater Interfaces ; 16(6): 8032-8044, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38291784

ABSTRACT

Tribological interfaces between silicon-based ceramics, such as Si3N4 or SiC, are characterized by high friction and wear in unlubricated conditions. A solution to this problem is to use them in combination with a hydrogenated amorphous carbon (a-C:H) countersurface from which a passivating carbon film is transferred onto the ceramic surface. However, the mechanisms underlying a stable film transfer process and the conditions that favor it remain elusive. Here, we present friction experiments in ultrahigh vacuum in which friction coefficients lower than 0.01 are achieved by sliding Si3N4 against a-C:H with 36 at. % hydrogen but not against a-C:H with 20 at. % hydrogen. Chemical surface analyses confirm that the superlubric interface forms via the transfer of a hydrocarbon nanofilm onto the Si3N4 surface. Quantum-mechanical simulations reveal that a stable passivating a-C:H film can only be transferred if, after initial cold welding of the tribological interface, the plastic shear deformation is localized within the a-C:H coating. This occurs if the yield shear stress for plastic flow of a-C:H is lower than that of the ceramic and of the shear strength of the a-C:H-ceramic interface, i.e., if the a-C:H hydrogen content ranges between ∼30 and ∼50 at. %. While the importance of a relatively high hydrogen content to achieve an efficient passivation of a-C:H surfaces in a vacuum is well-documented, this work reveals how the hydrogen content is also crucial for obtaining a stable a-C:H transfer film. These results can be extended to glass, SiC, and steel, supporting the generality of the proposed mechanism.

11.
Micromachines (Basel) ; 14(9)2023 Aug 26.
Article in English | MEDLINE | ID: mdl-37763829

ABSTRACT

The eXTP (enhanced X-ray Timing and Polarization) satellite is a prominent X-ray astronomy satellite designed primarily for conducting deep space X-ray astronomical observations. The satellite's scientific payload consists of X-ray focusing mirrors. In order to fulfill the requirements of weight reduction and enhanced effective area, the thickness of mirrors is reduced to the sub-millimeter range and a multi-layer nested structure is employed. Manufacturing mirrors poses a significant challenge to both their quality and efficiency. The present research investigates the optimal replication process for mandrel ultraprecision machining, polishing, coating, electroforming nickel, and demolding. It analyzes the factors contributing to the challenging separation and the inability to release the mirror shells. Additionally, an automatic demolding device is developed, and the X-ray performance of the replication mirrors is verified. The fabrication process flow of the mirrors was initially introduced. To ensure the easy release of the mirror shells from the mandrels, a layer of diamond-like carbon (DLC) was applied as a release layer between the Au and NiP alloy. The adhesion strength of Au-C was found to be significantly lower than that of Au-NiP, as demonstrated by both molecular dynamic simulation and tensile testing. The development of an automatic demolding device with force feedback has been successfully completed. The reduction in the half-power diameter (HPD) of the mirror from 48 inches to 25 inches is an improvement that surpasses the production target.

12.
Materials (Basel) ; 16(14)2023 Jul 11.
Article in English | MEDLINE | ID: mdl-37512219

ABSTRACT

Ionic liquid (IL) combined with graphene additives have garnered extensive attention in the field of high-performance lubricating materials. However, the ambiguous mechanism of graphene influencing the load-carrying and anti-wear capacity of ILs needs further study. In this work, friction simulation shows that adding graphene causes friction coefficient to reduce by up to 88% compared with pure ILs, but lubrication performance is lost due to the destruction of graphene under high stress. Meanwhile, multilayer graphene has better friction-reducing performance and friction durability as compared to the monolayer structure, which is attributed to the easy-shear property and the reduction in the percentage of high tensile stress sites in multilayer graphene structure. In addition, it was found that excessively thick ILs film would form a three-body abrasive wear structure with graphene, which accelerated the structural destruction of graphene and caused a decline in its tribological properties. It is believed these findings can be valuable for designing of high-performance lubricating oil for practical engineering.

13.
Nanotechnology ; 34(38)2023 Jul 06.
Article in English | MEDLINE | ID: mdl-37410425

ABSTRACT

Diamond-like carbon (DLC) films have broad application potential due to their high hardness, high wear resistance, and self-lubricating properties. However, considering that DLC films are micron-scale, neither finite element methods nor macroscopic experiments can reveal their deformation and failure mechanisms. Here we propose a coarse-grained molecular dynamics (CGMD) approach which expands the capabilities of molecular dynamics simulations to uniaxial tensile behavior of DLC films at a higher scale. The Tersoff potential is modified by high-throughput screening calculations for CGMD. Given this circumstance, machine learning (ML) models are employed to reduce the high-throughput computational cost by 86%, greatly improving the efficiency of parameter optimization in second- and fourth-order CGMD. The final obtained coarse-grained tensile curves fit well with that of the all-atom curves, showing that the ML-based CGMD method can investigate DLC films at higher scales while saving a large number of computational resources, which is important for promoting the research and production of high-performance DLC films.


Subject(s)
Carbon , Coated Materials, Biocompatible , Surface Properties , Materials Testing , Hardness
14.
Acta Biomater ; 167: 54-68, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37392935

ABSTRACT

Diamond-like carbon (DLC) coatings doped with bioactive elements of silver (Ag) and copper (Cu) have been receiving increasing attention in the last decade, particularly in the last 5 years, due to their potential to offer a combination of enhanced antimicrobial and mechanical performance. These multi-functional bioactive DLC coatings offer great potential to impart the next generation of load-bearing medical implants with improved wear resistance and strong potency against microbial infections. This review begins with an overview of the status and issues with current total joint implant materials and the state-of-the art in DLC coatings and their application to medical implants. A detailed discussion of recent advances in wear resistant bioactive DLC coatings is then presented with a focus on doping the DLC matrix with controlled quantities of Ag and Cu elements. It is shown that both Ag and Cu doping can impart strong antimicrobial potency against a range of Gram-positive and Gram-negative bacteria, but this is always accompanied so far by a reduction in mechanical performance of the DLC coating matrix. The article concludes with discussion of potential synthesis methods to accurately control bioactive element doping without jeopardising mechanical properties and gives an outlook to the potential long-term impact of developing a superior multifunctional bioactive DLC coating on implant device performance and patient health and wellbeing. STATEMENT OF SIGNIFICANCE: Multi-functional diamond-like carbon (DLC) coatings doped with bioactive elements of silver (Ag) and copper (Cu) offer great potential to impart the next generation of load-bearing medical implants with improved wear resistance and strong potency against microbial infections. This article provides a critical review of the state-of-the-art in Ag and Cu doped DLC coatings, beginning with an overview of the current applications of DLC coatings in implant technology followed by a detailed discussion of Ag/Cu doped DLC coatings with particular focus on the relationship between their mechanical and antimicrobial performance. Finally, it ends with a discussion on the potential long-term impact of developing a truly multifunctional ultra-hard wearing bioactive DLC coating to extend the lifetime of total joint implants.


Subject(s)
Copper , Joint Prosthesis , Humans , Copper/pharmacology , Silver/pharmacology , Carbon , Anti-Bacterial Agents/pharmacology , Gram-Negative Bacteria , Gram-Positive Bacteria
15.
ACS Appl Mater Interfaces ; 15(31): 37997-38007, 2023 Aug 09.
Article in English | MEDLINE | ID: mdl-37306622

ABSTRACT

The lubricity of hydrogenated diamond-like carbon (HDLC) films is highly sensitive to the hydrogen (H) content in the film and the oxidizing gas in the environment. The tribochemical knowledge of HDLC films with two different H-contents (mildly hydrogenated vs highly hydrogenated) was deduced from the analysis of the transfer layers formed on the counter-surface during friction tests in O2 and H2O using Raman spectroscopic imaging and X-ray photoelectron spectroscopy (XPS). The results showed that, regardless of H-content in the film, shear-induced graphitization and oxidation take place readily. By analyzing the O2 and H2O partial pressure dependence of friction of HDLC with a Langmuir-type reaction kinetics model, the oxidation probability of the HDLC surface exposed by friction as well as the removal probability of the oxidized species by friction were determined. The HDLC film with more H-content exhibited a lower oxidation probability than the film with less H-content. The atomistic origin of this H-content dependence was investigated using reactive molecular dynamics simulations, which showed that the fraction of undercoordinated carbon species decreased as the H-content in the film increased, corroborating the lower oxidation probability of the highly-hydrogenated film. The H-content in the HDLC film influenced the probabilities of oxidation and material removal, both of which vary with the environmental condition.

16.
Nanomaterials (Basel) ; 13(11)2023 May 31.
Article in English | MEDLINE | ID: mdl-37299675

ABSTRACT

It is important to understand the mechanical properties of diamond-like carbon (DLC) for use not only in frictionand wear-resistant coatings, but also in vibration reduction and damping increase at the layer interfaces. However, the mechanical properties of DLC are influenced by the working temperature and its density, and the applications of DLC as coatings are limited. In this work, we systematically studied the deformation behaviors of DLC under different temperatures and densities using compression and tensile testing of DLC by molecular dynamics (MD) methods. In our simulation results, the values of tensile stress and compressive stress decreased and tensile strain and compressive strain increased as the temperature increased from 300 K to 900 K during both tensile and compressive processes, indicating that the tensile stress and tensile strain depend on the temperature. During the tensile simulation, Young's modulus of DLC models with different densities had a different sensitivity to the increase in temperature, and the DLC model with a high density was more sensitive than that with a low density, which was not seen in the compression process. We conclude that the Csp3-Csp2 transition leads to tensile deformation, while the Csp2-Csp3 transition and relative slip dominate compressive deformation.

17.
J Artif Organs ; 2023 May 25.
Article in English | MEDLINE | ID: mdl-37227545

ABSTRACT

Staphylococcus aureus is one of the main causative bacteria for polyurethane catheter and artificial graft infection. Recently, we developed a unique technique for coating diamond-like carbon (DLC) inside the luminal resin structure of polyurethane tubes. This study aimed to elucidate the infection-preventing effects of diamond-like carbon (DLC) coating on a polyurethane surface against S. aureus. We applied DLC to polyurethane tubes and rolled polyurethane sheets with our newly developed DLC coating technique for resin tubes. The DLC-coated and uncoated polyurethane surfaces were tested in smoothness, hydrophilicity, zeta-potential, and anti-bacterial properties against S. aureus (biofilm formation and bacterial attachment) by contact with bacterial fluids under static and flow conditions. The DLC-coated polyurethane surface was significantly smoother, more hydrophilic, and had a more negative zeta-potential than did the uncoated polyurethane surface. Upon exposure to bacterial fluid under both static and flow conditions, DLC-coated polyurethane exhibited significantly less biofilm formation than uncoated polyurethane, based on absorbance measurements. In addition, the adherence of S. aureus was significantly lower for DLC-coated polyurethane than for uncoated polyurethane under both conditions, based on scanning electron microscopy. These results show that applying DLC coating to the luminal resin of polyurethane tubes may impart antimicrobial effects against S. aureus to implantable medical polyurethane devices, such as vascular grafts and central venous catheters.

18.
Materials (Basel) ; 16(9)2023 Apr 23.
Article in English | MEDLINE | ID: mdl-37176195

ABSTRACT

This study characterizes the mechanical performance of the AlSi10Mg alloy produced by powder bed fusion-laser beam (PBF-LB) subjected to two combined cycles consisting of multilayer coating deposition (electroless nickel (Ni-P) + diamond-like carbon (DLC)) and heat treatment. In particular, the DLC deposition phase replaces the artificial aging step in the T5 and T6 heat treatments, obtaining the following post-production cycles: (i) Ni-P + DLC deposition and (ii) rapid solution (SHTR) (10 min at 510 °C) before Ni-P + DLC deposition. Microstructural characterization shows no appreciable modifications in the morphology and dimensions of the hard Si-rich phase of the eutectic network and secondary spheroidal Si phase. However, overaging phenomena induced by DLC coating deposition and differences in elastic-plastic properties between the multilayer coating and the PBF-LB AlSi10Mg substrate lead to a reduction in tensile strength by up to 31% and a significant decrease in ductility by up to 58%. In contrast, higher resistance to crack opening thanks to improved surface hardness and residual compressive stresses of the coating and reduced defect sensitivity of the substrate increase the fatigue resistance by 54% in T5-coated alloy and 24% in T6R-coated alloy. Moreover, the coating remains well adherent to the substrate during fatigue testing, not becoming a source of fatigue cracks.

19.
Materials (Basel) ; 16(9)2023 Apr 27.
Article in English | MEDLINE | ID: mdl-37176304

ABSTRACT

Diamond-like carbon (DLC) films are generally used in biomedical applications, mainly because of their tribological and chemical properties that prevent the release of substrate ions, extend the life cycle of the material, and promote cell growth. The unique properties of the coating depend on the ratio of the sp3/sp2 phases, where the sp2 phase provides coatings with a low coefficient of friction and good electrical conductivity, while the share of the sp3 phase determines the chemical inertness, high hardness, and resistance to tribological wear. DLC coatings are characterized by high hardness, low coefficient of friction, high corrosion resistance, and biocompatibility. These properties make them attractive as potential wear-resistant coatings in many compelling applications, including optical, mechanical, microelectronic, and biomedical applications. Another great advantage of DLC coatings is that they can be deposited at low temperatures on a variety of substrates and can thus be used to coat heat-sensitive materials, such as polymers. Coating deposition techniques are constantly being improved; techniques based on vacuum environment reactions are mainly used, such as physical vapor deposition (PVD) and chemical vapor deposition (CVD). This review summarizes the current knowledge and research regarding diamond-like carbon coatings.

20.
ACS Appl Mater Interfaces ; 15(15): 19715-19729, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37029740

ABSTRACT

The anti-friction of diamond-like carbon (DLC) is achieved by a well-developed carbonaceous transfer layer, and Ti-doped DLC is developed into a robustly built-up carbonaceous transfer layer. The friction performance of DLC depends on the operating environment, e.g., ambient gas, humidity, temperature, lubricants, and mating material. In this study, we aimed to reveal the environmental sensitivities of Ti-DLC on friction characteristics. To this end, a Ti-DLC was rubbed against a steel ball, and friction behaviors were evaluated with different gas compositions, humidity, and temperature. Finally, we identified that fractional coverage of water on surfaces affected the anti-graphitization on Ti-DLC, leading to avoiding friction reduction.

SELECTION OF CITATIONS
SEARCH DETAIL