Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Publication year range
1.
Neurologia (Engl Ed) ; 37(5): 334-345, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35672120

ABSTRACT

OBJECTIVE: Stereoelectroencephalography (SEEG) is a technique for preoperative evaluation of patients with difficult-to-localise refractory focal epilepsy (DLRFE), enabling the study of deep cortical structures. The procedure, which is increasingly used in international epilepsy centres, has not been fully developed in Spain. We describe our experience with SEEG in the preoperative evaluation of DLRFE. MATERIAL AND METHODS: In the last 8 years, 71 patients with DLRFE were evaluated with SEEG in our epilepsy centre. We prospectively analysed our results in terms of localisation of the epileptogenic zone (EZ), surgical outcomes, and complications associated with the procedure. RESULTS: The median age of the sample was 30 years (range, 4-59 years); 27 patients (38%) were women. Forty-five patients (63.4%) showed no abnormalities on brain MR images. A total of 627 electrodes were implanted (median, 9 electrodes per patient; range, 1-17), and 50% of implantations were multilobar. The EZ was identified in 64 patients (90.1%), and was extratemporal or temporal plus in 66% of the cases. Follow-up was over one year in 55 of the 61 patients undergoing surgery: in the last year of follow-up, 58.2% were seizure-free (Engel Epilepsy Surgery Outcome Scale class I) and 76.4% had good outcomes (Engel I-II). Three patients (4.2%) presented brain haemorrhages. CONCLUSION: SEEG enables localisation of the EZ in patients in whom this was previously impossible, offering better surgical outcomes than other invasive techniques while having a relatively low rate of complications.


Subject(s)
Drug Resistant Epilepsy , Epilepsies, Partial , Epilepsy , Adolescent , Adult , Child , Child, Preschool , Drug Resistant Epilepsy/surgery , Electrodes, Implanted , Electroencephalography/methods , Epilepsies, Partial/surgery , Female , Humans , Male , Middle Aged , Stereotaxic Techniques , Young Adult
2.
Neurología (Barc., Ed. impr.) ; 37(5): 334-345, Jun. 2022. ilus, tab
Article in English, Spanish | IBECS | ID: ibc-205983

ABSTRACT

Objetivo: La estereoelectroencefalografía (E-EEG) es una técnica de evaluación prequirúrgica en pacientes con epilepsia focal refractaria de difícil localización (EFRDL) que permite explorar con electrodos profundos regiones cerebrales de difícil acceso y la profundidad de la corteza. Esta técnica, en auge en centros internacionales, apenas se ha desarrollado en España. Describimos nuestra experiencia con la E-EEG en la evaluación de pacientes con EFRDL. Material y métodos: En los últimos 8 años, 71 pacientes con EFRDL fueron evaluados con E-EEG en nuestro centro. Analizamos prospectivamente los resultados obtenidos en la localización, los resultados quirúrgicos y las complicaciones asociadas a la técnica. Resultados: La mediana de edad fue de 30 años (rango 4-59 años), 27 pacientes eran mujeres (38%). La RM cerebral fue negativa en 45 pacientes (63,4%). Se implantaron 627 electrodos (mediana de 9 electrodos por paciente, rango 1-17), con un 50% de implantaciones multilobares. En 64 (90,1%) pacientes se localizó la zona epileptógena (ZE), siendo extratemporal o temporal plus en el 66% de los casos. En 55 pacientes de los 61 intervenidos el seguimiento fue superior al año: en el último año de seguimiento 32/55 pacientes (58,2%) estaban libres de crisis (Engel I) siendo los resultados favorables (Engel I-II) en el 76,4% de las intervenciones. Tres pacientes (4,2%) presentaron una hemorragia cerebral. Conclusión: La E-EEG permite localizar la ZE en pacientes en quienes anteriormente no era posible, ofreciendo unos resultados quirúrgicos superiores a otras técnicas invasivas y una tasa de complicaciones relativamente baja. (AU)


Objective: Stereoelectroencephalography (SEEG) is a technique for preoperative evaluation of patients with difficult-to-localise refractory focal epilepsy (DLRFE), enabling the study of deep cortical structures. The procedure, which is increasingly used in international epilepsy centres, has not been fully developed in Spain. We describe our experience with SEEG in the preoperative evaluation of DLRFE. Material and methods: In the last 8 years, 71 patients with DLRFE were evaluated with SEEG in our epilepsy centre. We prospectively analysed our results in terms of localisation of the epileptogenic zone (EZ), surgical outcomes, and complications associated with the procedure. Results: The median age of the sample was 30 years (range, 4-59 years); 27 patients (38%) were women. Forty-five patients (63.4%) showed no abnormalities on brain MR images. A total of 627 electrodes were implanted (median, 9 electrodes per patient; range, 1-17), and 50% of implantations were multilobar. The EZ was identified in 64 patients (90.1%), and was extratemporal or temporal plus in 66% of the cases. Follow-up was over one year in 55 of the 61 patients undergoing surgery: in the last year of follow-up, 58.2% were seizure-free (Engel Epilepsy Surgery Outcome Scale class I) and 76.4% had good outcomes (Engel I-II). Three patients (4.2%) presented brain haemorrhages. Conclusion: SEEG enables localisation of the EZ in patients in whom this was previously impossible, offering better surgical outcomes than other invasive techniques while having a relatively low rate of complications. (AU)


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Young Adult , Adult , Middle Aged , Drug Resistant Epilepsy/surgery , Epilepsies, Partial/surgery , Epilepsy , Electrodes, Implanted , Electroencephalography/methods , Stereotaxic Techniques
3.
Neurologia (Engl Ed) ; 2019 Jul 20.
Article in English, Spanish | MEDLINE | ID: mdl-31337558

ABSTRACT

OBJECTIVE: Stereoelectroencephalography (SEEG) is a technique for preoperative evaluation of patients with difficult-to-localise refractory focal epilepsy (DLRFE), enabling the study of deep cortical structures. The procedure, which is increasingly used in international epilepsy centres, has not been fully developed in Spain. We describe our experience with SEEG in the preoperative evaluation of DLRFE. MATERIAL AND METHODS: In the last 8 years, 71 patients with DLRFE were evaluated with SEEG in our epilepsy centre. We prospectively analysed our results in terms of localisation of the epileptogenic zone (EZ), surgical outcomes, and complications associated with the procedure. RESULTS: The median age of the sample was 30 years (range, 4-59 years); 27 patients (38%) were women. Forty-five patients (63.4%) showed no abnormalities on brain MR images. A total of 627 electrodes were implanted (median, 9 electrodes per patient; range, 1-17), and 50% of implantations were multilobar. The EZ was identified in 64 patients (90.1%), and was extratemporal or temporal plus in 66% of the cases. Follow-up was over one year in 55 of the 61 patients undergoing surgery: in the last year of follow-up, 58.2% were seizure-free (Engel Epilepsy Surgery Outcome Scale class I) and 76.4% had good outcomes (Engel I-II). Three patients (4.2%) presented brain haemorrhages. CONCLUSION: SEEG enables localisation of the EZ in patients in whom this was previously impossible, offering better surgical outcomes than other invasive techniques while having a relatively low rate of complications.

4.
Neurocirugia (Astur) ; 27(6): 277-284, 2016.
Article in Spanish | MEDLINE | ID: mdl-27345416

ABSTRACT

OBJECTIVE: To report a novel, accurate, and safe technique for deep brain electrode implantation to register brain electrical activity or SEEG, using frameless stereotaxy, neuronavigation assisted, and intraoperative CT-guided O-Arm® and the Vertek® articulated passive arm. MATERIAL AND METHODS: All patients implanted by this technique in Barcelona Hospital Clinic were included. A prospective evaluation was made of the accuracy of the technique, as well as complications, surgical time, length of stay, and short-term outcomes. RESULTS: The study included 10 patients that underwent this procedure. The mean age was 38 years, and 60% were women. A mean of 6.9 (3-10) electrodes/patient, with a total of 69 electrodes, were implanted. The mean time for implantation was 34.7minutes per electrode. The mean distance between the planned target and the final target was 1.39 millimetres (0.95-1.7). There were no surgically derived complications. The epileptogenic zone was determined in 6 cases (60%). Surgical resection was performed in 5 cases (50%), with thermocoagulation in 3 (30%) cases, and in 2 cases (20%) there was no treatment. At a six-month follow-up of the 8 treated cases, 37.5% were ELAI I, 12.5% ELAI III, 25% ELAI IV, and 25% ELAI V. CONCLUSIONS: The implantation of deep brain electrodes for SEEG by using intraoperative CT O-Arm® and the Vertek® articulated passive arm is a safe and effective technique with adequate accuracy.


Subject(s)
Epilepsy/surgery , Neuronavigation , Stereotaxic Techniques , Surgery, Computer-Assisted , Adult , Electrodes, Implanted , Electroencephalography , Female , Humans , Imaging, Three-Dimensional , Male , Prospective Studies , Referral and Consultation , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL